가정용 보일러의 불완전연소가스 누출확산 메커니즘 해석 (Analysis of Mechanism for Diffusion of Incomplete Combustion Gas Released from Domestic Gas Boiler)

  • 강승규;최경석;윤준용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2868-2873
    • /
    • 2008
  • Carbon Monoxide(CO) poisoning accident is higher than any other gas accident in the rate of deaths/incidents. In the last five years, 36 people died and 104 were wounded because of carbon monoxide poisoning accident. Most of these CO poisoning accidents were caused by defective exhaust tube in the old gas boiler and multi-use facility. In this study, the spread of incomplete combustion gas(CO) released from leakage hole of exhaust tube was analyzed by computational flow modeling and concentration measuring test. CO gas leaked form exhaust tube in a building was highest concentrated near the ceiling and formed the circular currents along the walls. Through these experiments and simulation, the reasonable installation location of carbon monoxide alarm was made certain and suggested.

  • PDF

가스보일러 배기통 이탈에 의한 CO가스 누출확산 실험 및 수치해석 (EXPERIMENTAL AND COMPUTATIONAL PREDICTION OF CONCENTRATION OF CARBON MONOXIDE GAS RELEASED FROM EXHAUST TUBE OF GAS BOILER)

  • 강승규;최경석;윤준용
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.172-175
    • /
    • 2008
  • In the last five years, 45 people died and 104 were wounded because of carbon monoxide poisoning accident. CO poisoning accident is higher than any other gas accident in the rate of deaths/incidents. Most of these CO poisoning accidents were caused by defective exhaust tube in the old gas boiler and multi-use facility. In this study, the spread of CO gas released from leakage hole of exhaust tube was analyzed by computational flow modeling and concentration measuring test. CO gas leaked form exhaust tube in a building was highest concentrated near the ceiling and formed the circular currents along the walls. Through these experiments and simulation, the reasonable installation location of CO alarm was made certain and suggested.

  • PDF

건축물내 일산화탄소 경보기 설치기준에 관한 연구 (A Study on the Standard for Installation of Carbon Monoxide Detector in a Building)

  • 강승규;최경석
    • 한국가스학회지
    • /
    • 제12권4호
    • /
    • pp.1-7
    • /
    • 2008
  • 최근 5년간 국내 가스사고 중 CO중독사고는 사망 36명, 부상 79명이 발생하였으며, 전체 가스 사고에 비해 인명피해율이 8배나 높게 나타나고 있다. 이러한 CO중독사고의 대부분이 노후 가스보일러 및 다중 가스 사용시설의 배기통 불량에 의한 가스누출사고로 조사되고 있다. 본 연구에서는 실험을 통해 건축물 내 보일러실의 배기통 불량에 의한 CO가스의 누출확산 메커니즘을 해석하였다. 배기통에서 누출된 CO 가스는 건축물 내부의 천정부근에서 가장 높은 농도분포를 보인다. 또한 CO경보기 설치 실험을 통해서 천정부근의 CO경보기가 가장먼저 작동하고, $30{\sim}40$분 경과한 후에 바닥 및 중간에 설치된 경보기가 작동하는 것을 확인하였다. 본 연구를 통해 CO경보기의 적정 설치위치를 확인하였으며, 이 결과를 토대로 건출물내 CO경보기 설치위치를 제안하였다.

  • PDF

화재 예방을 위한 태양광 접속반의 지능형 진단 시스템 (Intelligent Diagnostic System of Photovoltaic Connection Module for Fire Prevention)

  • 안재현;양오
    • 반도체디스플레이기술학회지
    • /
    • 제20권3호
    • /
    • pp.161-166
    • /
    • 2021
  • To prevent accidents caused by changes in the surrounding environment or other factors, various protection facilities are installed at the photovoltaic connection module. The main causes of fire are sparks due to foreign substances inside the photovoltaic connection module through high temperature rise and dew condensation in the photovoltaic connection module, and fire due to heat from the power diode. The proposed method can predict the fire by measuring flame, carbon dioxide, carbon monoxide, temperature, humidity, input voltage, and current on the photovoltaic connection module, and when the fire conditions are reached, fire alarm and power off can be sent to managers and users in real time to prevent fire in advance.

지하상가 가스누출 사고 환자들에 대한 임상적 고찰 - 일산화탄소 중독 - (Clinical Evaluation of Patients Intoxicated by a Gas Leak at an Underground Shopping Center - Carbon Monoxide Poisoning -)

  • 안지영;고영길
    • 대한임상독성학회지
    • /
    • 제4권2호
    • /
    • pp.122-127
    • /
    • 2006
  • Purpose: It is not easy to detect carbon monoxide (CO) leakage, and CO-intoxicated patients do not show a specific set of symptoms. The aims of this study are to clinically evaluate patients with CO gas intoxication from a CO leak at an underground shopping center, and to discuss the establishment of a disaster prevention plan. Methods: A total of 51 patients intoxicated by CO gas exposure in a gas disaster at a underground shopping center in Seoul on September 8, 2006 were enrolled in this study, and the patients' medical records were retrospectively reviewed. Results: The mean patient age was $29.4{\pm}6.3$. The initial mean COHb level was $14.98{\pm}6.97%$. The number of patients with COHb greater than 25% was three, and six patients experienced a syncopal attack. Only one patient-was treated with hyperbaric oxygen therapy. However, none of the patients complained of severe neurologic or cardiovascular symptoms. Conclusion: The symptoms of CO intoxication are non-specific and difficult to define, and the detection of CO leak-age is difficult. Thus, workplaces should be equipped with leakage sensors and automatic alarm systems and should have develop disaster prevention plans.

  • PDF

건축물내 일산화탄소 경보기 설치에 관한 연구 (A Study on Installation of Carbon Monoxide Detector in a Building)

  • 강승규;최경석;오정석
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2008년도 춘계학술 발표회
    • /
    • pp.217-222
    • /
    • 2008
  • In the last five years, 45 people died and 104 were wounded because of carbon monoxide poisoning accident. CO poisoning accident is higher than any other gas accident in the rate of deaths/incidents. Most of these CO poisoning accidents were caused by defective exhaust tube in the old gas boiler and multi-use facility. In this study, the spread of CO gas released from leakage hole of exhaust tube was analyzed by concentration measuring test. CO gas leaked form exhaust tube in a building was highest concentrated near the ceiling. Through these experiments, the reasonable installation location of CO alarm was made certain and suggested.

  • PDF

가스보일러 CO중독 위험성 예측 및 근원적 예방기술 개발 (The Risk Assessment of Carbon Monoxide Poisoning by Gas Boiler Exhaust System and Development of Fundamental Preventive Technology)

  • 박찬일;류기윤
    • 한국가스학회지
    • /
    • 제25권3호
    • /
    • pp.27-38
    • /
    • 2021
  • 본 연구에서는 가스보일러 가동 중 배기통이 이탈하는 상황이 발생했을 때, 시스템적으로 인지하고 자동으로 보일러 가동을 중지하여 일산화탄소를 포함한 유해 배기가스가 실내로 유입되는 상황을 근원적으로 차단하는 방안을 제시하였다: (1) 연소에 필요한 공기량을 제어하기 위해 설치된 풍압센서(APS : Air Pressure Sensor)의 출력전압을 측정하여 배기통의 정상상태와 이탈상태를 감시하는 기능을 추가한다. (2) 배기통이 이탈하면 APS의 출력전압이 상시 운전범위에서 일시적으로 상승하게 된다. 보일러 제어부인 PCB가 이 상태를 배기통 이탈로 간주하여 보일러 가동을 멈추면서 배기통 이탈 상태를 실내온도 조절기에 표시하도록 한다. 또한 국토교통부령으로 정한 「건축물의 설비기준 등에 관한 규칙」에서 명시한 공동주택 및 다중이용시설의 환기시설 기준에 따라, 실내공기 교환횟수에 맞는 풍량을 적용하여 실내공기를 환기하는 실험을 실시하였다. 이 실험 결과 실제 일산화탄소가 실내에 누출된 최악의 상태에서, 중독사고 예방이 가능하다는 것을 확인하였다. 다만, 동 규칙에서 정의한 시간당 실내공기 교환횟수를 기존 0.7회에서 0.5회로 2013년부터 완화하여 운영하고 있는데, 실험결과 8시간 가중평균 노출기준인 TWA 30 ppm을 초과하는 농도가 측정되어 기준을 강화할 필요성이 있다. 본 연구 결과에 기초하여 가스보일러 배기압력의 기계적 인지를 통해 배기통 이탈을 감지하는 기술과 일산화탄소 경보기와 연동된 실내공기 환기시스템 기술을 도입한다면 일산화탄소 중독사고가 크게 감소될 것으로 판단된다. 제조 및 검사단계의 문제점을 보완하고, 올바른 설치 및 수리, 사용자의 배기통 이탈에 대한 관심이 더해졌을 때, 일산화탄소 중독으로 인한 인명사고를 예방하는데 효과적인 대책이 될 것으로 사료된다.

연기/CO 및 연기/열 복합형 IoT 멀티 화재 감지기의 화재감지실험 연구 (A Study on Fire Alarm Test of IoT Multi-Fire Detector combined Smoke/CO and Smoke/Temperature Sensors)

  • 손근식;소수현
    • 한국재난정보학회 논문집
    • /
    • 제17권2호
    • /
    • pp.236-244
    • /
    • 2021
  • 연구목적: 연기/CO/열 복합형 화재감지기와 무선 IoT통신을 결합한 IoT 멀티화재감지기를 개발하고 화재감지 실험을 통하여 연기/CO/열 복합형 IoT 멀티화재감지기의 화재감지성능을 확인하는 것을 목적으로 한다. 연구방법: 연기/CO 복합형 과 연기/열 복합형의 IoT 멀티화재감지기를 연기발생기와 면 심지 연소를 통하여 화재감지성능을 실험하였으며, 화제 신호를 발하는 기준을 확인하였다. 연구결과: 연기/CO 복합형 IoT 멀티 화재감지기는 면심지 연소 실험에서 화재를 감지하였으나 연기발생기 실험에서는 화재를 감지하지 않았다. 반면 연기/열 복합형 IoT 멀티 화재감지기는 두 실험 모두 화재를 감지하지 않았다. 결론: 연기/CO 복합형 IoT 멀티화재감지기는 CO가 포함된 연기만을 감지하였으며, 연기/열 복합형 IoT 멀티 화재감지기는 열의 부족에 의해 화재를 잠지하지 않았다. 이와 같은 결과로 개발된 IoT 멀티 화재감지기는 면심지 연소 실험과 연기발생기 실험을 통해 2가지 센서의 기준값 이상 신호를 검출하여야 화재 신호를 발한다는 것을 확인하였다.

Fabrication and characterization of a small-sized gas identification instrument for detecting LPG/LNG and CO gases

  • Lee Kyu-Chung;Hur Chang-Wu
    • Journal of information and communication convergence engineering
    • /
    • 제4권1호
    • /
    • pp.18-22
    • /
    • 2006
  • A small-sized gas identification system has been fabricated and characterized using an integrated gas sensor array and artificial neural-network. The sensor array consists of four thick-film oxide semiconductor gas sensors whose sensing layers are $In_{2}O_{3}-Sb_{2}O_{5}-Pd-doped\;SnO_2$ + Pd-coated layer, $La_{2}O_{5}-PdCl_{2}-doped\;SnO_2,\;WO_{3}-doped\;SnO_{2}$ + Pt-coated layer and $ThO_{2}-V_{2}O_{5}-PdCl_{2}\;doped\;SnO_{2}$. The small-sized gas identification instrument is composed of a GMS 81504 containing an internal ROM (4k bytes), a RAM (128 bytes) and four-channel AD converter as MPU, LEDs for displaying alarm conditions for three gases (liquefied petroleum gas: LPG, liquefied natural gas: LNG and carbon monoxide: CO) and interface circuits for them. The instrument has been used to identify alarm conditions for three gases among the real circumstances and the identification has been successfully demonstrated.

가스보일러 일산화탄소 누출사고 경감에 관한 연구 (A Study on Prevention of Accidents of Carbon Monoxide Leak from Gas Boilers)

  • 송재창;권휘웅;이영희;문일
    • Korean Chemical Engineering Research
    • /
    • 제50권2호
    • /
    • pp.277-281
    • /
    • 2012
  • 본 연구는 가스보일러 CO 누출사고 경감방안에 관한 연구로서, CO 경보기 및 콘덴싱 보일러 의무화 설치 및 지원금 방법을 제시하였다. CO 중독을 예방하기 위해 CO 경보기를 의무 설치하여야 하며 현재 국산 CO 경보기의 가격이 약 4만원이며, 기초수급생활자 및 일반가정 400만 가구 대상으로 3 년 간 1,000억원의 금액이 소요됨을 제시하였다. 기초생활수급자 20만원, 일반가정 10만원, 400만 가구를 지원해주면, 3 년 간 5,000억원의 금액이 소요되며, 재정마련은 연간 100만대 판매되는 보일러를 콘덴싱 보일러로 의무화 시 년 간 약 2,000억원의 에너지 절감이 되며, 콘덴싱 보일러의 수명이 10년으로 했을 때 총 2조원의 에너지 절감비용이 생긴다. 그 중 6,000억원의 비용은 CO 경보기 및 콘덴싱 보일러 설치 지원비로 사용하며, 10년간 국내가스사고 CO 누출사고 50% 이상의 사고를 경감할 수 있을 것으로 제시하였다.