• 제목/요약/키워드: capillary limit

검색결과 76건 처리시간 0.023초

Capillary Zone Electrophoresis를 이용한 음이온 동시분석에 관한 연구 (Analysis of Inorganic Acids by Capillary Zone Electrophoresis)

  • 박성우;진광호;유재훈;김동환;서배석;김영상
    • 분석과학
    • /
    • 제11권3호
    • /
    • pp.213-221
    • /
    • 1998
  • Bromide, chloride, fluoride, nitrite, nitrate, sulfite, sulfate, perchlorate, chlorate 및 chlorite가 포함된 시료를 capillary zone electrophoresis(CZE)와 indirect UV detection 방법으로 분리하였다. 음이온류의 분리는 running buffer로 5 mM ammonium dichromate, 10 mM ammonium acetate, 20 mM diethylenetriamine, 10% methanol(pH 9.3)을 사용하였으며 전압은 cathode에 15 kV를 공급하였다. 또한 최초로 CZE에서 음이온의 정량이 가능하도록 각 이온들에 대한 regression과 detection limit를 결정하였고, 이 분석방법은 톨루엔을 흡입한 사람의 뇨, 부검 혈액, 폐수 및 폭약 등 시료에 적용하였으며, 음이온의 함량을 ion chromatograph(IC)와 비교 검토하였다.

  • PDF

Determination of Co(II) Ion as a 4-(2-Thiazolylazo)resorcinol or 5-Methyl-4-(2-thiazolylazo)resorcinol Chelate by Reversed-Phase Capillary High-Performance Liquid Chromatography

  • Chung, Yong-Soon;Chung, Won-Seog
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권12호
    • /
    • pp.1781-1784
    • /
    • 2003
  • Determination of Co(II) ion as a 4-(2-thiazolylazo)resorcinol(TAR) or 5-methyl-4-(2-thiazolylazo)resorcinol(5MTAR) chelate was accomplished by reversed-phase capillary high-performance liquid chromatography (RP-Capillary-HPLC) using a Vydac $C_4$ column and MeCN-water mixture as mobile phase. The effect of change in pH and MeCN percentage of the mobile phase on the retention factor, k and peak intensity were evaluated. It was found that 30% MeCN (v/v) of pH 5.60 or 7.20 was adequate as mobile phase when TAR or 5MTAR is used. Detection limit (D.L., S/N=3) in each case was $2.0\;{\times}\;10^{-7}$M (11.8 ppb) and $3.0\;{\times}\;10^{-7}$ M (17.7 ppb). The Co(II) ion in mineral and waste water was determined with the optimum column and mobile phase.

Syringe Infusion-based Contactless Atmospheric Pressure Ionization Mass Spectrometry for Small and Large Biomolecules

  • Lo, Ta-Ju;Chang, Chia-Hsien;Chen, Yu-Chie
    • Mass Spectrometry Letters
    • /
    • 제3권4호
    • /
    • pp.87-92
    • /
    • 2012
  • In this study, we explored a new approach for generating ions of organics and biomolecules using contactless atmospheric pressure ionization (C-API). That is, a tapered capillary (~20 cm) was connected to a syringe, which was coupled to a syringe pump for providing a given flow rate to introduce sample solution to the proximity of a mass spectrometer. The gas phase ions derived from analytes were readily formed in the capillary outlet, which was very close to the mass spectrometer (~1 mm). No external electric connection was applied on the capillary emitter. This setup is very simple, but it can function as an ion source. This approach can be readily used for the analysis of small molecules such as amino acids and large molecules such as peptides and proteins. The limit of the detection of this approach was estimated to be ~10 pM when using bradykinin as the sample. Thus, we believe that this approach should be very useful for being used as an alternative ion source because of its low cost, high sensitivity, simplicity, and ease of operation.

Determination of Terbutaline Enantiomers in Human Urine by Capillary Electrophoresis Using $Hydroxypropyl-{\beta}-cyclodextrin$ as a Chiral Selector

  • Kim, Kyeong-Ho;Seo, Sang-Hun;Kim, Hyun-Ju;Jeun, Eun-Young;Kang, Jong-Seong;Mar, Woong-Chon;Youm, Jeong-Rok
    • Archives of Pharmacal Research
    • /
    • 제26권2호
    • /
    • pp.120-123
    • /
    • 2003
  • A method for the determination of terbutaline enantiomers in human urine by capillary elctrophoresis has been developed. Optimum resolution was achieved using 50 mM phosphate buffer, pH 2.5, containing 15 mM of hydroxypropyl-$\beta$-cyclodextrin as a chiral selector. Urine samples were prepared by solid-phase extraction with Sep-pak silica, followed by CE. The assay was linear between 2-250 ng/mL (R = 0.9998 for (S)-(+)-terbutaline and R = 0.9999 for (R)-(-)-terbutaline) and detection limit was 0.8 ng/mL. The intra-day variation ranged between 6.3 and 14.5% in relation to the measured concentration and the inter-day variation was 8.2-20.1%. It has been applied to the determination of (S)-(+)-terbutaline and (R)-(-)-terbutaline in urine from healthy volunteer dosed with racemic terbutaline sulfate.

Analytical study on seepage behavior of a small-scale capillary barrier system under lateral no-flow condition

  • Byeong-Su Kim
    • Geomechanics and Engineering
    • /
    • 제35권1호
    • /
    • pp.13-27
    • /
    • 2023
  • The model production for large-scale (lateral length ≥ 2.0 m) capillary barrier (CB) model tests is time and cost-intensive. To address these limitations, the framework of a small-scale CB (SSCB) model test under the lateral no-flow condition has been established. In this study, to validate the experimental methodology of the SSCB model test, a series of seepage analyses on the SSCB model test and engineered slopes in the same and additional test conditions was performed. First, the seepage behavior and diversion length (LD) of the CB system were investigated under three rainfall conditions. In the seepage analysis for the engineered slopes with different slope angles and sand layer thicknesses, the LD increased with the increase in the slope angle and sand layer thickness, although the increase rate of the LD with the sand layer thickness exhibited an upper limit. The LD values from the seepage analysis agreed well with the results estimated from the laboratory SSCB mode test. Therefore, it can be concluded that the experimental methodology of the SSCB model test is one of the promising alternatives to efficiently evaluate the water-shielding performance of the CB system for an engineered slope.

액체 필름 끝단에서의 유동특성에 관한 수치연구 (Blob and Wave Formation at the Free Edge of an Initially Stationary fluid Sheet)

  • 송무석;안자일
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.307-310
    • /
    • 2002
  • A two-dimensional numerical method for inviscid two-fluid flows with evolution of density interface is developed, and an initially stationary two-dimensional fluid sheet surrounded by another fluid is studied. The Interface between two fluids is modeled as a vertex sheet, and the flow field u÷th the evolution of interface is solved by using vortex-in-cell/front-tracking method. The edge of the sheet Is pulled back into the sheet due to surface tension and a blob is formed at the edge. This blob and fluid sheet are connected by a thin neck. In the inviscid limit, such process of the blob and neck formation is examined in detail and their kinematic characteristics are summarized with dimensionless parameters. The edge recedes at $V=1.06({\sigma}/{\rho}h)^{0.5}$ and the capillary wave Propagating into the fluid sheet must be considered for bettor understanding of the edge receding.

  • PDF

Gas Chromatograph에 의한 Arylmethy Halides의 정량 (Determination of Arylmethyl Halides by Gas Chromatograph)

  • 오도석;최호춘
    • 한국산업보건학회지
    • /
    • 제4권1호
    • /
    • pp.25-32
    • /
    • 1994
  • Arylmethyl halides(benzyl chloride, BZYC; benzal chloride, BZYA; benzotrichloride, BZTC) and related compounds(benzyl alcohol, BZYA; benzoyl chloride, BZOC) were determined by GC using capillary column. Detailed results are as follows. 1. Stability In methanol benzotrichloride slowly transferred to benzoyl chloride by hydrolysis(ca. 7.5% for 5 days), but the others were stable. Therefore, benzotrichloride solution should be prepared just before analysis. 2. GC analysis Tenax-GC was used to absorbent and desorption solvents were $CCl_4$ and MeOH. Arylmethyl halides were analyzed within 7.5min without interference with related compounds. The calibration curve(ca. 15-80 ppm in soln), repeatability(n=10) and the desorption efficiency were good. Limit of detection by NIOSH method was about 0.003 ppm for arylmethyl halide, respectively. To analyze arylmethyl halides and related compounds in working places GC using capillary column is anticipated to be used effectively.

  • PDF

Capillary Electrophoresis Detection of Hydrogen Peroxide by Using Titanium Ion and 4-(2-thiazolylazo)resorcinol

  • Vu Phuong, Dong;Yoo, Hoon
    • International Journal of Oral Biology
    • /
    • 제42권4호
    • /
    • pp.197-201
    • /
    • 2017
  • A novel method for the detection of hydrogen peroxide in aqueous solution was developed via reaction between $H_2O_2$, trivalent titanium ion ($Ti^{3+}$) and 4-(2-thiazolylazo) resorcinol (TAR), resulting in a ternary complex with a maximum UV absorbance at 530 nm. The CE detection of $H_2O_2$ was fast, sensitive and cost-effective without pretreatment procedures. $H_2O_2$ was detected within 15 min at 1 to $100{\mu}M$ range with the lowest detection limit at $1.0{\mu}M$. Under the optimized CE conditions, the concentration of $H_2O_2$ in coffee or tea extract was quantitatively determined. Our results show that CE detection of the ternary complex of $H_2O_2-Ti^{3+}$-TAR has potential applications for the detection of $H_2O_2$ in aqueous sources.

원통형 열모세관 액적 내 유동 불안정성과 회전의 영향 (Hydrodynamic Instabilities in Cylindrical Thermocapillary Liquid Bridges with Rotation)

  • 이유섭;;전중환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.39-44
    • /
    • 2001
  • The thermocapillary flow in a differentially heated cylindrical liquid bridge under steady rotation of the hot disk is considered in the limit of zero capillary number. Steady flow states and their three-dimensional stability are calculated numerically. A linear stability analysis reveals that the most dangerous perturbations are oscillatory with azimuthal wavenumber m=1 or m=2 depending on the parameters.

  • PDF

소형 소결웍 히트파이프의 제조 기술개발에 관한 연구 (A Study on the Manufacturing Technology of Heat Pipes with a Sintered Metal Wick)

  • 김성대;성병호;강환국;김철주
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2003년도 추계 학술발표회 논문집
    • /
    • pp.291-297
    • /
    • 2003
  • For the present study, three heat pipes with different thickness of sintered metal wick were manufactured, and their operational performances, such as capillary limit and thermal resistance were tested and compared with theoretical predictions. Experimental results showed good agreement with those by the theoretical model, and that seemed to present that the sintering process we had developed ;n the present study was valid.

  • PDF