Chiral Separation of Aromatic Amino Acids by Capillary Electrophoresis using (+)-18-crown-6 tetracarboxylic acid and (-)-18-crown-6 tetracarboxylic acid as Chiral Selectors

  • Choi, Young-Me;La, Sook-Ie;Lee, Won-Jae;Kim, Kyoung-Rae
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.278.1-278.1
    • /
    • 2003
  • Recently, particular attention has been paid to the chiral separation of amino acid enantiomers because of their different biological activities. Hence, the high optical purity of aromatic amino acids is critical because of their important functions in the central nervous system. For the accurate chiral discrimination. we attempted to exploit the crosschecking each enantiomeric migraion orders of aromatic amino acids measured using (+)-18C6H4TA and (-)-18C6H4TA as the chiral selectors under pH 2.0, tris/citric acid buffer.

  • PDF

Therapeutic Monitoring on Urinary Nucleoside and Polyamine Levels of Cancer Patients by CE and GC under Acupuncture Treatment

  • Paik, Man-Jeong;La, Sook-Ie;Lee, Yoon-Suk;Kim, Ji-Yung;Choi, Young-Me;Kuon, Do-Won;Kim, Jung-Han;Kim, Kyoung-Rae
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.284.1-284.1
    • /
    • 2003
  • Modified nucleosides and polyamines excreted in urine are well-known as biochemical markers for cancer. The metabolomics on the urinary nucleosides and polyamines is thus gaining interest in the cancer study. In this study, the levels of nucleosides and polyamines in urine samples from cancer patients under acupuncture treatment were determined by high resolution capillary electrophoresis and gas chromatography, respectively. (omitted)

  • PDF

Metabolite Profiling of Serum from Patients with Tuberculosis

  • Park, Hee-Bin;Yoo, Min-Gyu;Choi, Sangho;Kim, Seong-Han;Chu, Hyuk
    • Microbiology and Biotechnology Letters
    • /
    • v.49 no.2
    • /
    • pp.264-268
    • /
    • 2021
  • Tuberculosis (TB) is a major infectious disease that threatens the life and health of people globally. Here, we performed a metabolomic analysis of serum samples from patients with intractable TB to identify biomarkers that might shorten the TB treatment period. Serum samples collected at the commencement of patients' treatment and healthy controls were analyzed using the capillary electrophoresis and time-of-flight mass spectrometry metabolome analysis method. The analysis identified the metabolites cystine, kynurenine, glyceric acid, and cystathionine, which might be useful markers for monitoring the TB treatment course. Furthermore, our research may provide experimental data to develop potential biomarkers in the TB treatment course.

Replacement of the in vivo Bioassay for Erythropoietin with the in vitro Bioassay (Erythropoietin in vivo 시험법의 in vitro 대체 시험법 확립)

  • 백상훈;김진만;권기성;박송용;허재욱
    • KSBB Journal
    • /
    • v.18 no.4
    • /
    • pp.255-260
    • /
    • 2003
  • In vivo bioassays for biological medicines have been considered final resort to unequivocally assess the biological activities for them because there are some cases in which the biological activities obtained from in vivo bioassay and in vitro bioassay quite differ each other. The in vivo biological activity of EPO depends on its sialic acid contents which confer microheterogeneity-isoforms to this protein. We have devise a method which consists of a in vitro bioassay using BaF3 cell line and a capillary zone electrophoresis (CZE) for the measurement of the EPO isoform distribution. The biological activity of EPO obtained using in vitro bioassay with BaF3 cell line showed good correlation (C.V.(%) 7.34, 5.85, 8,16, 8.08, 8.8) to EPO content measured either spectrophotometric assay (A280 0.1 % =0.743) or radio immunoassay. The assay validation results of in vitro bioassay with 3 lot of in house EPO showed good results to EPO content measured either in vivo assay or radio immunoassay. and also showed good results the robustness of our method in terms of precision, accuracy, repeatability. The isoform distribution for EPO-BRP (1 : 1 mixture of epoetin-${\alpha}$ and epoetin-${\beta}$, European Pharmacopoeia) by CZE method resulted in isoform 2 through isoform 8. The major peaks in electrophoregram were composed of isoform 3 through 7. Our recombinant EPO (epoetin-${\alpha}$) having equivalent in vivo biological activity showed the isoform distribution of isoform 3 through 9. The major peaks consisted of isoform 4 through 8. The peak area of isoform 4 was always smaller than that of isoform 5. The preparations of recombinant epoetin-${\alpha}$ with lower in vivo biological activity than EPO-BRP showed the isoform 2 through 8 in their electrophoregrams whose major peaks consisted of the isoform 3 through 7. The peak area of isoform 4 was larger than that of isoform 5.

The Immunotyping Distribution of Serum Monoclonal Paraprotein and Environmental Impact on Multiple Myeloma (MM) and Monoclonal Gammopathy of Uncertain Significance (MGUS) in Taiwan: A Medical Center-Based Experience

  • Chang, Chih-Chun;Su, Ming-Jang;Lee, Shu-Jene;Tsai, Yu-Hui;Kuo, Lin-Yin;Lin, I-Hsin;Huang, Hui-Ling;Yen, Tzung-Hai;Chu, Fang-Yeh
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.1
    • /
    • pp.395-399
    • /
    • 2016
  • Background: Whether ambient exposure to environmental pollutants leads to hematopoietic malignancies such as multiple myeloma (MM) remains to be ascertained. Therefore, we aimed to investigate the immunotyping distribution of serum monoclonal paraprotein and the environmental influence on MM and monoclonal gammopathy of uncertain significance (MGUS) in the Taiwanese population. Materials and Methods: Serum protein electrophoresis with immunosubtraction by the capillary zone electrophoresis method was performed as primary screening for MM and MGUS. Clinical, pathological, and residence data of patients were also obtained. Results: From August, 2013 to June, 2015, a total of 327 patients underwent serum protein electrophoresis with immunosubtraction. Among these, 281 demonstrated no remarkable findings or non-malignant oligoclonal gammopathy, 23 were detected to have MGUS, 18 were identified as MM, and a further 5 were found as other malignancies. The most frequent immunotyping distribution of serum monoclonal paraprotein was IgG kappa (54.3%, n=25), followed by IgA lambda (15.2%, n=7) and IgG lambda (10.9%, n=5) in subjects with gammopathy. Additionally, it was shown that the elderly (OR: 4.61, 95% CI: 1.88-11.30, P<0.01) and males (OR: 2.04, 95% CI: 1.04-4.02, P=0.04) had significantly higher risk of developing MM and MGUS. There was no obvious impact of environmental factors on the health risk of MM and MGUS evolution (OR: 0.77, 95% CI: 0.40-1.50, P=0.49). Conclusions: The most frequent immunotyping distribution of serum monoclonal paraprotein included IgG kappa, IgA lambda and IgG lambda in MM and MGUS in the Taiwanese population. The elderly and male subjects are at significantly higher risk of MM and MGUS development, but there was no obvious impact of environmental factors on risk.

Isotachophoretically Assisted On-Line Complexation of Trace Metal Ions in a Highly Saline Matrix for Capillary Electrophoresis

  • Kim, Ji-Hye;Choi, Ki-Hwan;Cho, Sun-Young;Riaz, Asif;Chung, Doo-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.3
    • /
    • pp.790-794
    • /
    • 2012
  • Trace metal ions such as $Cd^{2+}$, $Ni^{2+}$, and $Zn^{2+}$ in a highly saline sample were subjected to on-line complexation with 4-(2-thiazolylazo) resorcinol (TAR) dissolved in a background electrolyte (BGE) under transient isotachophoresis (TITP) conditions. A long plug of the saline sample, containing the trace metal ions but devoid of TAR, was injected into a coated capillary filled with a BGE composed of 150 mM 2-(cyclohexylamino) ethanesulfonic acid (CHES) and 110 mM triethylamine (TEA) at pH 9.7. Since the electrophoretic mobility of TAR fell between the mobilities of the anionic leading electrolyte ($Cl^-$ in the sample) and the anionic terminating background electrolyte ($CHES^-$), a highly concentrated zone of TAR from the BGE was formed at the rear of the sample matrix and then the metal cations toward the cathode were swept by isotachophoretically assisted on-line complexation (IAOC) between the metal ions and the isotachophoretically stacked TAR. As a result, anionic metal-TAR complexes were formed efficiently, which satisfy the TITP conditions between $Cl^-$ and $CHES^-$. The enrichment factors of metal ions including $Cd^{2+}$ were up to 780-fold compared to a conventional CZE mode using absorbance detection. The detection limits were 17 nM, 15 nM, and 27 nM for $Ni^{2+}$, $Zn^{2+}$, and $Cd^{2+}$ in a 250 mM NaCl matrix, respectively. Our method was successfully applied to the analysis of urine samples without desalting.

Bioseparations in Lab-On-A-Chip (랩온어칩에서의 생물분리기술)

  • Chang Woo-Jin;Koo Yoon-Mo
    • KSBB Journal
    • /
    • v.20 no.3
    • /
    • pp.197-204
    • /
    • 2005
  • Lab-on-a-chip is a miniaturized analytical device in which all of the procedures for the analysis of molecules are carried out, such as pretreatment, reaction, separation, detection, etc. Lab-on-a-chip has increasing concern as a device not only for rapid detection of molecules but also for high throughput screening and point of care, because conventional laborious and time consuming analytical procedures can be substituted. Thus, a lot of microfabrication and analytical techniques for lab-on-a-chip have been developed with microstructures smaller than a few hundreds of micrometers. Separation of the molecules is one of the most important components of lab-on-a-chip, because effective separation method can simplify the design and can provide better sensitivity. The electrokinetic separation based on capillary electrophoresis is most widely employed technique in lab-on-a-chip for the control of fluids and the separation of molecules. In this article, bioseparation techniques and its applications realized in lab-on-a-chip are reviewed.

Action of atmospheric pressure non-thermal plasma on the biomolecules and bio-organism

  • Attri, Pankaj;Park, Ji Hoon;Kumar, Naresh;Ali, Anser;Kim, In Tae;Lee, Weontae;Choi, Eun Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.66.1-66.1
    • /
    • 2015
  • Plasma medicine is an upcoming research area that has attracted the scientists to explore more deeply the utility of plasma. So, apart from the treating biomaterials and tissues with plasma, we have studied the effect of plasma with different feeding gases on modification of biomolecules. Additionally, we have checked the action of nanosecond pulsed plasma on the biomolecules. We have checked the plasma action on proteins ((Hemoglobin (Hb) Myoglobin (Mb) and lysoenzyme), calf thymus DNA and amino acids. The structural changes or structural modification of proteins and DNA have been studied using circular dichroism (CD), dynamic light scattering (DLS), gel electrophoresis, protein oxidation test, UV-vis spectroscopy and 1D NMR, while Liquid Chromatograph/Capillary Electrophoresis-Mass Spectrometer(LC/CE-MS) based qualitative bio-analysis have been used to study the modification of amino acids. We have also shown the effect of NaCl and ionic liquid on the formation of OH radicals using electron spin resonance and fluorescence techinques.

  • PDF

A Comprehensive Identification of Synaptic Vesicle Proteins in Rat Brains by cRPLC/MS-MS and 2DE/MALDI-TOF-MS

  • Lee, Won-Kyu;Kim, Hye-Jung;Min, Hye-Ki;Kang, Un-Beom;Lee, Cheol-Ju;Lee, Sang-Won;Kim, Ick-Young;Lee, Seung-Taek;Kwon, Oh-Seung;Yu, Yeon-Gyu
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.9
    • /
    • pp.1499-1509
    • /
    • 2007
  • Proteomic analyses of synaptic vesicle fraction from rat brain have been performed for the better understanding of vesicle regulation and signal transmission. Two different approaches were applied to identify proteins in synaptic vesicle fraction. First, the isolated synaptic vesicle proteins were treated with trypsin, and the resulting peptides were analyzed using a high-pressure capillary reversed phase liquid chromatography/tandem mass spectrometry (cRPLC/MS/MS). Alternatively, proteins were separated by two-dimensional gel electrophoresis (2DE) and identified by matrix-assisted laser desorption ionization mass spectrometry (MALDI-TOF/MS). Total 18 and 52 proteins were identified from cRPLC/MS-MS and 2DE-MALDI-TOF-MS analysis, respectively. Among them only 2 proteins were identified by both methods. Of the proteins identified, 70% were soluble proteins and 30% were membrane proteins. They were categorized by their functions in vesicle trafficking and biogenesis, energy metabolism, signal transduction, transport and unknown functions. Among them, 27 proteins were not previously reported as synaptic proteins. The cellular functions of unknown proteins were estimated from the analysis of domain structure, expression profile and predicted interaction partners.

Sheathless electrospray ionization with integrated metal emitter on microfluidic device (전기 분무 이온화를 이용한 단백질 질량분석용 마이크로 유체 소자의 제작 및 실험)

  • Kim, Min-Su;Joo, Hwang-Soo;Lee, Kook-Nyung;Kim, Byung-Gee;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.2102-2104
    • /
    • 2004
  • In this study, sheathless electrospray from PDMS/glass microchips with conducting metal emitter tip is described. A chip-based capillary electrophoresis/mass spectrometry (CE/MS) system has advantages of the CE separation and on-line electrospray detection of peptide solution. We have fabricated a new electrospray ionization(ESI) device composed of the metal emitter tip and CE separation channel monolithically in a glass microchip. The separation channel and metal emitter tip are fabricated using a glass wet etching and gold electro plating process, respectively. The fabricated micro electrospray chip was tested by spraying peptide sample for mass spectrometric analysis. Singlely-charged peak and doublely-charged peak of peptide were detected and further MS/MS fragmentation was performed in each peak. Direct comparisons with conventional glass or fused silica emitters showed very similar performance with respect to signal strength and stability.

  • PDF