• Title/Summary/Keyword: capacitance value

Search Result 340, Processing Time 0.022 seconds

The measurement of capacitance of W/O type emulsified fuel using by capacitance sensor (정전용량센서를 이용한 W/O형 유화연료의 정전용량 측정)

  • Cho, Seong-Cheol;Oh, Yang-Hwan;Im, Seok-Yeon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.377-382
    • /
    • 2007
  • We designed capacitance sensor in order to examine characteristics of W/O type emulsified fuel, so it concluded the following conclusions. The capacitance value of emulsified fuel, using with capacitance sensor, increases as water content increases due to the coalescence. When surfactant increases, the capacitance value decreases, the condition of W/O type emulsified fuel was maintained stably. There was revealed the capacitance value difference of W/O type emulsified fuel in in according to water content. We checked the phase separation of emulsified fuel with the capacitance value difference. The surfactant(HLB=5.4) had better stable condition than surfactant(HLB=4.3). Also, we confirmed that two mixture surfactants were better than one surfactant.

Ratio-type Capacitance Measurement Circuit for femto-Farad Resolution (펨토 패럿 측정을 위한 비율형 커패시턴스 측정 회로)

  • Chung, Jae-Woong;Chung, In-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.5
    • /
    • pp.989-998
    • /
    • 2012
  • A ratio type of capacitance measurement circuit is proposed to measure an extremely small value of the fF capacitance on this paper. This measurement circuit is formed with a switched-capacitor integrator, a comparator, and logic circuit blocks to control the switches. It converts the measured ratio value between the known value of on-chip capacitor and the unknown value of capacitor to the digital signal. The fF capacitance with minimized error can be obtained by calculating this ratio. This proposed circuit is designed with standard CMOS $0.18{\mu}m$ process, and various HSpice simulations prove that this capacitance measurement circuit is able to measure the capacitance under 5fF with less than ${\pm}0.3%$ error rate.

The Design of Capacitance Variation Detector for the Obstacle Detection System (방해물 감지 장치용 캐패시턴스 변화 감지기의 설계)

  • Kim, Jae-Min;Song, Yun-Seob;Yi, Sang-Yeoul;Kim, Soo-Won
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.133-138
    • /
    • 2004
  • Today, the obstacle detection system has massive size and restrictive detection range. To solve these problems, this paper proposes the capacitance variation detector using the variated capacitance value as a result of the obstacle approaching. If obstacle approaches, the capacitance value of capacitance sensor is increased and the operating frequency of oscillator is decreased. Then this changed frequency appears to the output of the mixer that operate down conversion. The capacitance variation detector is produced by Hynix$0.35{\mu}$ CMOS process. In experiment result, the frequency of final output is 6.81 MHz at no obstacle and 31.45 MHz at approaching obstacle. In conclusion, proposed capacitance variation detector has small size, low power consumption and easiness to set up anywhere. So it is expected to substitute the obstacle detector.

A Study for Implementation of Density Measurement Equipment for Asphalt Pavement based on the electromagnetic capacitance

  • Park, Young-Ho;Kim, Gun-Kyun;Nor, Jeong-Keun;Ha, Jae-Kwon
    • International Journal of Contents
    • /
    • v.6 no.4
    • /
    • pp.39-42
    • /
    • 2010
  • In this paper we developed density measurement equipment for Asphalt Pavement based on the electromagnetic capacitance. This kind of Non-Nuclear Density Gauges technology and products is used or studied in USA, Finland, Sweden as standardization of authorized method for pavement density measurement. Effective permitivity of pavement asphalt is characterized in electromagnetic capacitance by the asphalt material, mixed ratio, and harden grade of pavement asphalt. We can get a density value of asphalt by replacing value of electromagnetic capacitance with standard density value and characteristic transformation curve. We are conformed that measurement data according to temperature, humidity, and real field asphalt of our density measurement equipment can be a precise value.

Electrical and Physical Properties of Sheath-core Type Conductive Textile Sensor with Home-Textile (Sheath-core 구조 전도사 섬유센서의 Home-Textile 적용을 위한 전기·물리학적 특성연구)

  • Cho, Kwang-Nyun;Jung, Hyun-Mi
    • Fashion & Textile Research Journal
    • /
    • v.16 no.1
    • /
    • pp.145-152
    • /
    • 2014
  • The usage of textile-based sensors has increased due to their many advantages (compared to IT sensors) when applied to body assessment and comfort. Textile-based sensors have different detecting factors such as pressure, voltage, current and capacitance to investigate the characteristics. In this study, textile-based sensor fabrics with sheath-core type conductive yarns were produced and the relationship between capacitance changes and applied load was investigated. The physical and electric properties of textile-based sensor fabrics were also investigated under various laminating conditions. A textile based pressure sensor that uses a sheath-core conductive yarn to ensure the stability of the pressure sensor in the textile-based sensor (the physical structure of the reaction characteristic of the capacitance) is important for the stability of the initial value of the initial capacitance value outside the characteristic of the textile structural environment. In addition, a textile based sensor is displaced relative to the initial value of the capacitance change according to pressure changes in the capacitance value of the sensor due to the fineness of the high risk of noise generation. Changing the physical structure of the fabric through the sensor characteristic of the pressure sensor via the noise generating element of laminating (temperature, humidity, and static electricity) to cut off the voltage output element to improve the data reliability could be secured.

Effect of Soft Error Rate on SRAM with Metal Plate Capacitance

  • Kim Do-Woo;Gong Myeong-Kook;Wang Jin-Suk
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.6
    • /
    • pp.242-245
    • /
    • 2005
  • We compared and analyzed ASER (Accelerated Soft Error Rate) for cell structures and metal plate capacitance in the fabricated 16M SRAM. Application of the BNW (Buried NWELL) lowered the ASER value compared to the normal well structure. By applying the metal plate capacitor with the BNW, the lowest ASER value can be obtained. The thinner oxide thickness of the metal plate capacitor provides higher capacitance and lower ASER value. The ASER is improved from 2200 FIT to 1000 FIT after sole application of the BNW. However, it is dramatically improved to 15 FIT once the metal plate capacitor is additionally applied.

Determining Method of Minimum-capacitance for Self-excited Induction Generator (자기 여자 유도 발전기의 최소 커패시턴스의 결정법)

  • Jin, Chung-Min;Jwa, Chong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.729-731
    • /
    • 2000
  • This paper presents a simple method for determining the minimum value of capacitance required for initiating self excitation in three-phase self-excited induction generator. Based on the steady-state equivalent circuit model, this paper presents simple and direct method to find the minimum capacitance requirement under R-L load. Using the loop impedance and nodal admittance. the minimum capacitance is determined by self excitation condition. These computed values can be used to predict practically the minimum value of the terminal voltage required for self-excitation. To maintain a constant terminal voltage, a method for determining the frequency, terminal capacitance, and exciting reactance is also described.

  • PDF

The Effect of Oleic Acid and Propylene Glycol on the Electrical Properties of Skin (올레인산 및 프로필렌글리콜이 피부의 전기적 성질에 미치는 영향)

  • Oh, Seaung-Youl;Guy, Richard H.
    • Journal of Pharmaceutical Investigation
    • /
    • v.24 no.4
    • /
    • pp.281-287
    • /
    • 1994
  • The effects of oleic acid, propylene glycol and 5% (w/w) oleic acid in propylene glycol on the electrical properties of hairless mouse skin were studied and the results were compared. The complex electrical impedance was measured as a function of frequency, and resistance and capacitance were determined from the Nyquist plot. Immediately after the treatment with oleic acid, resistance was 145% of the pretreatment value. However it decreased with time and, after 20 hours, it was about 25% of its pretreatment value. Capacitance increased; immediately after the treatment, it was about 125% of pretreatment value and it seemed to increase slowly with time. When the skin was treated with propylene glycol, resistance decreased about 5O% and capacitance increased about 65%. Similar results were observed when the skin was treated with 5% (w/w) oleic acid in propylene glycol, except that the magnitude of resistance drop was much larger. Oleic acid acted synergistically with propylene glycol. Together with the flux data in the literature, the results obtained in this work indicate that electrical resistance is closely related to the permeability of drug molecules through the skin. The results are discussed in terms of the mechanism of action of these penetration enhancers. Overall, this work provided further mechanistic insight into the role of SC lipids in skin resistance and capacitance.

  • PDF

Effect of Enhancers on the Electrical Properties of Skin: The Effect of Azone and Ethanol

  • Oh, Seaung-Youl;Guy, Richard H.
    • Journal of Pharmaceutical Investigation
    • /
    • v.24 no.3
    • /
    • pp.41-47
    • /
    • 1994
  • The effect of Azone and ethanol on the electrical properties of human and hairless mouse skin was studied and the results were compared. The complex electrical impedance was measured as a function of frequency, and resistance and capacitance were determined from Nyquist plot. After the treatment of human-heat separated epidermis with Azone, contrary to the expectation, resistance increased about 60% and it did not change with time. Capacitance also increased; immediately after the treatment, it was about 110% of pretreatment value and it increased further with time. On the other hand, when hairless mouse skin was treated with Azone, marked changes occured; resistance fell almost to the value of bathing medium itself and capacitance increased to about 200% of its pretreatment value. Similar result were obtained when hairless mouse skin was treated with 100% ethanol. The results suggest that there are differences in the strength of barrier properties of stratum corneum (SC) between human and hairless mouse skin. Overall, the results provide further mechanistic insight into ion conduction through the skin and into the role of SC lipids in skin capacitance.

  • PDF

The operation properties of DBD reactors in air pressure with varying the capacitance of reactors (정전 용량변화에 따른 대기압 DBD 반응기의 동작 특성 연구)

  • 박봉경;김윤환;장봉철;조정현;김곤호
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.4
    • /
    • pp.440-448
    • /
    • 2001
  • The operation properties of DBD plasma reactors were observed by using 20 kV square pulse at the cylindrical and planar type of reactors in the condition of air pressure. The optimum operation frequency $f_0$ which optimizes the efficiency of operation was found as such $f_0\proptoexp(-C)$ when the current-voltage curve and charge-voltage curve were observed. Using these properties the dissipated power was evaluated. The dissipated power at the optimum frequency of operation was varied as the value of capacitance which is dependent on the structure and the dielectric material of the reactor, and had the maximum value at the specific value of capacitance. With these value of capacitance, DBD reactors which has a high level of efficiency can be formed.

  • PDF