• Title/Summary/Keyword: capacitance measurement

Search Result 395, Processing Time 0.031 seconds

Direct Measurement of the VLSI Interconnection Line Capacitances Using a Grounded Shield Plate (접지된 Shield Plate를 이용한 집적회로의 배선용량 측정)

  • 강래구;전성오;신윤승
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.3
    • /
    • pp.302-307
    • /
    • 1988
  • A noble interconnection line capacitance measurement method to be able to remove the measurement errors from the probe pad to substrate stray capacitance has been proposed and verified. The measurement errors in the capacitance measurement, which usually be involved from the probe pad to substrate stray capacitance, can easily be removed by isolating the metal probe pad from the substrate with a grounded shield plate between the probe pad the substrate. The measurement results by using this improved capacitance measurement method were compared with the calculations by two-dimensional computer simulations.

  • PDF

A New Measurement Method of Dielectric Constants Applied the Principles of Cross Capacitance (Cross Capacitance 원리를 작용한 새로운 유전상수 측정방법 제안)

  • Kim, Han-Jun;Lee, Rae-Duk;Kang, Jeon-Hong;Yu, Kwang-Min;Han, Sang-Ok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.1084-1087
    • /
    • 2002
  • The guard-ring type 3-terminal parallel plate electrodes proposed by ASTM D 150-81 and IEC 250 have been widely used for measurement of dielectric constants of solid dielectrics. However the method using this electrodes causes many uncertainty associated with the measurement errors of the diameter of the guarded electrode. the gap between guarded and guard-ring electrode. the distance of two active electrodes(the thickness of specimen), the roughness and contamination of surface of electrode and specimen. close adherence grade of electrode and specimen. In this paper. a new electrode system of cross capacitance type based on Thompson-Lampard theorem is designed and is employed for the measurement of dielectric constant. The results of simulation of guard-ring electrode and cross capacitance electrode using FEM program show that distance measurement between two electrodes in guard-ring electrode produces large uncertainty. on the other hand this effect in cross capacitance electrode is negligible. Furthermore. the air gap effects in the cross capacitance electrode is 5.6 times less sensitive than that in guard-ring electrode by assuming air gap of $50{\mu}m$.

  • PDF

Ratio-type Capacitance Measurement Circuit for femto-Farad Resolution (펨토 패럿 측정을 위한 비율형 커패시턴스 측정 회로)

  • Chung, Jae-Woong;Chung, In-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.5
    • /
    • pp.989-998
    • /
    • 2012
  • A ratio type of capacitance measurement circuit is proposed to measure an extremely small value of the fF capacitance on this paper. This measurement circuit is formed with a switched-capacitor integrator, a comparator, and logic circuit blocks to control the switches. It converts the measured ratio value between the known value of on-chip capacitor and the unknown value of capacitor to the digital signal. The fF capacitance with minimized error can be obtained by calculating this ratio. This proposed circuit is designed with standard CMOS $0.18{\mu}m$ process, and various HSpice simulations prove that this capacitance measurement circuit is able to measure the capacitance under 5fF with less than ${\pm}0.3%$ error rate.

Precise Measurement of Dielectric Constant Using Cross Capacitance Measurement Method (Cross Capacitance 측정법을 이용한 유전상수 정밀측정)

  • Kim, Han-Jun;Kang, Jeon-Hong;Yu, Kwang-Min;Lee, Sei-Hyun;Koo, Kyung-Wan;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1287-1288
    • /
    • 2007
  • The cross capacitor electrode system applied Thompson-Lampard theorem for precise and accurate measurement of dielectric constants is studied in this study. The capacitance derived from cross capacitor is calculated by the equation of ($C=\frac{{\epsilon}ln2}{\pi}{\cdot}$ effectivelength of electrode) which is very different from the equation of capacitance derived from parallel plate capacitor. From above mentioned reason, the capacitance measurement uncertainty of cross capacitor can be reduced then that of the parallel plate capacitor. the measurement dielectric constant measured by cross capacitor electrode method is one order more accurate and precise than that of 3-electrode method.

  • PDF

A Study for Implementation of Density Measurement Equipment for Asphalt Pavement based on the electromagnetic capacitance

  • Park, Young-Ho;Kim, Gun-Kyun;Nor, Jeong-Keun;Ha, Jae-Kwon
    • International Journal of Contents
    • /
    • v.6 no.4
    • /
    • pp.39-42
    • /
    • 2010
  • In this paper we developed density measurement equipment for Asphalt Pavement based on the electromagnetic capacitance. This kind of Non-Nuclear Density Gauges technology and products is used or studied in USA, Finland, Sweden as standardization of authorized method for pavement density measurement. Effective permitivity of pavement asphalt is characterized in electromagnetic capacitance by the asphalt material, mixed ratio, and harden grade of pavement asphalt. We can get a density value of asphalt by replacing value of electromagnetic capacitance with standard density value and characteristic transformation curve. We are conformed that measurement data according to temperature, humidity, and real field asphalt of our density measurement equipment can be a precise value.

BURR SIZE MEASUREMENT USING A CAPACITANCE SENSOR

  • Lee, Seoung-Hwan
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.4
    • /
    • pp.29-37
    • /
    • 1999
  • This paper involves the "on-line" measurement of burrs using a capacitance sensor. A non-contact capacitance gauging sensor is attached to an ultra precision milling machine which was used as a positioning system The setup is used to measure burr profiles along machined workpiece edges. Experimental procedures and results as well as the basic theoretical principles of the capacitance sensor and specifications of related equipment are presented. The proposed scheme is shown to be accurate easy to setup and with minor modifications readily applicable to automatic deburring processes.processes.

  • PDF

The thermal effect on electrical capacitance sensor for two-phase flow monitoring

  • Altabey, Wael A.
    • Structural Monitoring and Maintenance
    • /
    • v.3 no.4
    • /
    • pp.335-347
    • /
    • 2016
  • One of major errors in flow rate measurement for two-phase flow using an Electrical Capacitance Sensor (ECS) concerns sensor sensitivity under temperature raise. The thermal effect on electrical capacitance sensor (ECS) system for air-water two-phase flow monitoring include sensor sensitivity, capacitance measurements, capacitance change and node potential distribution is reported in this paper. The rules of 12-electrode sensor parameters such as capacitance, capacitance change, and change rate of capacitance and sensitivity map the basis of Air-water two-phase flow permittivity distribution and temperature raise are discussed by ANSYS and MATLAB, which are combined to simulate sensor characteristic. The cross-sectional void fraction as a function of temperature is determined from the scripting capabilities in ANSYS simulation. The results show that the temperature raise had a detrimental effect on the electrodes sensitivity and sensitive domain of electrodes. The FE results are in excellent agreement with an experimental result available in the literature, thus validating the accuracy and reliability of the proposed flow rate measurement system.

A Compact and Fast Measurement System for the Detection of Small Capacitance

  • Youngshin Woo;Sung, Man-Young
    • Transactions on Electrical and Electronic Materials
    • /
    • v.2 no.1
    • /
    • pp.16-21
    • /
    • 2001
  • A new technique to measure low level capacitance variations of a gyroscope is proposed. It is based on the improved CVC(capacitance to voltage converter) biased by a d.c. current source and the peak detector without any low pass filter. This setup of the measurement system makes it possible to provide higher speed of measurement and wide operation range. The d,c, drift of the conventional CVC and stray capacitances are automatically compensated. Key parameters that affect the performance of the measurement system are illustrated and computer simulation results are presented. The demonstrated measurement system for micromachined gyroscope applications shows a linearity of 0.99972 and a resolution of 0.67fF from 10 fF to 120 fF at 10 kHz.

  • PDF

A Study on Influencing Factors of Unit-Water Measurement method according to Electrostatic capacity (정전용량에 따른 단위수량 측정기법의 영향인자에 대한 실험적 연구)

  • We, Joon-Woo;Lee, Young-Jin;Kim, Jeong-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.232-233
    • /
    • 2013
  • The unit-water content in fresh concrete determines consistency, and play an important role in condensing the structure of concrete and enhancing the durability of concrete. The capacitance measurement method measure quickly unit-water content and is the best way to apply to construction site. In this study, the unit-water content of capacitance measurement method is estimated according to types and replacemment ratio of admixture. and the field application of capacitance measurement method is reviewed.

  • PDF

Applicability of Resistivity/Capacitance Measurement on CPT Module for Investigation of Subsurface Contamination (오염지반 조사를 위한 전기비저항/정전용량 측정콘의 적용성 평가)

  • Oh, Myoung-Hak;Kim, Yong-Sung;Yoo, Dong-Ju;Park, Jun-Boum
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.330-337
    • /
    • 2006
  • Resistivity cone penetrometer test (RCPT) can be employed at a relatively low cost for delineation of subsurface contamination in situ, and then be supplemented with a minimum confirmatory sampling and laboratory testing program. While the resistivity measurement have potential to investigate the subsurface contamination, resistivity measurements alone will lead to some degree of ambiguity in the results. In this study, capacitance measurement was incorporated into the RCPT to overcome the ambiguity inherent in electrical resistivity measurements for delineating the subsurface contamination. This study is focused on verifying the applicability of resistivity and capacitance measurements on CPT module to provide information on contaminated subsurface by heavy metal and petroleum hydrocarbon. Laboratory model tests were performed to evaluate the sensitivity of the measured resistivity and relative capacitance on the water content and different types of contaminants. Test results show that simultaneous measurement of electrical resistivity and capacitance can give more reliable information on subsurface contamination.

  • PDF