• 제목/요약/키워드: cantilevers

검색결과 118건 처리시간 0.032초

Evaluation of time-dependent deflections on balanced cantilever bridges

  • Rincon, Luis F.;Viviescas, Alvaro;Osorio, Edison;Riveros-Jerez, Carlos A.;Lozano-Galant, Jose Antonio
    • Computers and Concrete
    • /
    • 제28권5호
    • /
    • pp.487-495
    • /
    • 2021
  • The use of prestressed concrete box girder bridges built by segmentally balanced cantilevers has bloomed in the last decades due to its significant structural and construction advantages in complex topographies. In Colombia, this typology is the most common solution for structures with spans ranging of 80-200 m. Despite its popularity, excessive deflections in bridges worldwide evidenced that time-dependent effects were underestimated. This problem has led to the constant updating of the creep and shrinkage models in international code standards. Differences observed between design processes of box girder bridges of the Colombian code and Eurocode, led to the need for a validation of in-service status of these structures. This study analyzes the long-term behavior of the Tablazo bridge with data scarcity. The measured leveling of this structure is compared with a finite-element model that consider the most widely used creep and shrinkage models in the literature. Finally, an adjusted model evidence excessive deflection on the bridge after six years. Monitoring of this bridge typology in Colombia and updating of the current design code is recommended.

비균열 외팔 보형 회전날개의 진동특성에 관한 연구

  • 정인성;채회창;박태원;이기형;이환성
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 추계학술대회 논문집
    • /
    • pp.96-100
    • /
    • 2001
  • A method is presented for determining the free vibration characteristics of a rotating blade having nonuniform span wise properies and cantilevers boundary condition. The equations which govern the coupled the coupled flapwise, choirwise, and torsional motion of such a blade are solved using an integrating matrix method. By expressing the equation of motion in matrix notation, utilizing the integrating matrix as an operator, and applying the boundary condition, the equations are formulated into an eigenvalues problem whose solution may be determined by conventional method. Computer results are compared with experimental data.

Development of $16{\mu}m{\times}16{\mu}m$ Digital Micromirror Array Suitable for Seamless-picture Projection Display System

  • Kim, Dae-Hyun;Jeon, Jin-Wan;Lim, Koeng-Su;Yoon, Jun-Bo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권2호
    • /
    • pp.1159-1162
    • /
    • 2007
  • We have developed $16{\mu}m{\times}16{\mu}m$ digital micromirror array suitable for seamless-picture projection display system. This structure can improve the picture quality by making seamlesspicture image when combined with high-fill-factor microlens array to focus lights onto the mirror center. The fabricated micromirror shows excellent dynamic performances including the resonant frequency of 400 kHz.

  • PDF

Silicon-no-insulatir 구조를 갖는 실리콘 압저항 가속도계 (A Silicon Piezoresistive Accelerometer with Silicon-on-insulator Structure)

  • 양의혁;양상식
    • 대한전기학회논문지
    • /
    • 제43권6호
    • /
    • pp.1036-1038
    • /
    • 1994
  • In this paper, a silicon piezoresistive accelerometer is designed and fabricated using a silicon direct bonded wafer. The accelerometer consists of a seismic mass and four cantilevers, and is fabricated mainly by the anisotropic etching method using EPW as an etchant. The measured sensitivity and the resonant frequency are 0.02 mV/V.g and 3.4 kHz, respectively. The nonlinearity is less than $\pm$0.3% of the full scale of the output.

  • PDF

마이크로 CCR구현을 위한 저전압 구동 압전 반사경 설계 (Design of Low Voltage Piezoelectric Actuated Mirror for Micro-CCR)

  • 이덕현;양창수;박재영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1454-1455
    • /
    • 2008
  • This paper present a piezoelectric actuated mirror with PZT cantilevers, torsional bars and hinges for Micro-CCR (corner cube retroreflector). The actuated mirror with low voltage and large tilting angle is designed and simulated by using FEM (Finite Element Method) simulator (CoventorWare). The tilting angle of actuated mirror is 2.93$^{\circ}$ at low voltage of 5V.

  • PDF

동특성 변화로부터 구조물의 변경질량 위치 해석 (Analysis of Mass Position Detection Using the Change of the Structural Dynamic Characteristics)

  • 이정윤
    • 한국공작기계학회논문집
    • /
    • 제13권2호
    • /
    • pp.120-126
    • /
    • 2004
  • This study proposed the analysis of mass position detection due to the change of the mass and strifeless of structure by using the original and modified dynamic characteristics. The method is applied to examples of the cantilevers beam and the 3 degrees of freedom system by modifying the mass. The predicted detection of the mass positions and magnitudes are in good agrement with the present study from the structural reanalysis using the modified mass.

바이몰프형 압전세라믹 캔틸레버를 이용한 수력에너지 하베스터 모듈 제작 및 발전 특성 (Fabrication and Energy Harvesting Characteristics of Water Energy Harvester Using Piezoelectric Ceramic Bimorph Cantilever)

  • 김경범;김창일;윤지선;정영훈;남중희;조정호;백종후;남산;성태현
    • 한국전기전자재료학회논문지
    • /
    • 제25권12호
    • /
    • pp.943-948
    • /
    • 2012
  • A new water energy harvester module, which is composed of piezoelectric bimorph cantilevers, harvesting circuit and a shaft with 16 impellers at a center axis, was fabricated for energy harvesting application. High energy density $Pb(Zr_{0.54}Ti_{0.46})O_3$ + 0.2 wt% $Cr_2O_3$ + 1.0 wt% $Nb_2O_5$ (PZT-CN) thick film obtained by tape casting method was used for the bimorph cantilever. The PZT-CN bimorph cantilever with a proof mass of 49 g exhibited extremely high output power of 22.5 mW (24 $mW//cm^3$) at resonance frequency of 11 Hz. In addition, the fabricated water energy harvester has a cylindrical structure with 48 bimorph cantilevers clamped at inner surface. A significantly high output power of 433 mW was obtained at a rotation speed of 120 rpm with a resistive load of $500{\Omega}$ for the water energy harvester.

기하학적. 재료적 비선형성을 갖는 중첩된 판 스프링의 특성해석에 관한 연구 (A study on the characteristic analysis of superposed leaf springs with geometric and material nonlinearities)

  • 김형구;임정식;김일곤;손동성
    • 대한기계학회논문집
    • /
    • 제14권1호
    • /
    • pp.13-22
    • /
    • 1990
  • 본 연구에서는 일반적인 셸 요소에 대해 von Mises의 항복조건에 입각한 탄소 성 구성방정식과 total Lagrangian식을 바탕으로한 비선형 해석이론에 Lagrange Mult- iplier식을 이용한 구속조건(constraints)을 도입하여, 중첩된 비선형 구조물이 갖고 있는 제반 비선형성을 고려할 수 있도록 수식화하였으며, 이를 엄밀해를 구할 수 있는 두개의 외팔보가 중첩된 경우에 적용하여 엄밀해와 비교하였으며, 또한 실제적으로 국 산 핵연료 집합체에 사용되는 각 홀드다운 스프링 집합체에 대한 특성 해석을 수행하 여 그 결과를 실험치와 비교하여 그 비교치가 근사함을 보임으로써 본 방법의 신뢰성 과 효용성을 보였다.

정밀 마찰측정을 위한 이중 캔틸레버 구조 마찰시험기의 설계에 관한 연구 (A Study on the Design of a Double Cantilever Structure Friction Tester for Precision Friction Measurement)

  • 강원빈;김현준
    • Tribology and Lubricants
    • /
    • 제34권4호
    • /
    • pp.125-131
    • /
    • 2018
  • A precision tribometer consisting of a cantilever was designed to measure frictional forces in the micro-Newton range. As frictional forces are measured based on the bending of the cantilever, vibration of the cantilever is the most significant factor affecting the quality of the friction measurement. Therefore, improved design of the tribometer with double cantilevers and a connecting plate that united the two cantilevers mechanically was suggested. For the verification of the modified design of the tribometer, numerical analysis and experiments were conducted. Examination using the finite element method revealed that the tribometer with a double cantilever and a connecting plate exhibited faster damping characteristics than the tribometer with a single cantilever. In the experiment, effectiveness of the double cantilever and connecting plate for vibration reduction was also confirmed. Vibration of the tribometer with double cantilever decreased eight times faster than that of the tribometer with a single cantilever. The faster damping of the double cantilever design is attributed to the mechanical interaction at the contacting surfaces between the cantilever and the connecting plate. Tribotesting using the tribometer with a single cantilever resulted in random fluctuation of frictional forces due to the stick-slip behavior. However, using the tribometer with a double cantilever and connecting plate for the tribotest gave relatively uniform and steady measurement of frictional forces. Increased stiffness owing to using a double cantilever and mechanical damping of the connecting plate were responsible for the stable friction signal.

실리콘 선택적 기상 성장을 이용한 마이크로 센서에 응용되는 구조물 제조법 (Application of selective Epitaxial Growth of Silicon on MEMS Structure)

  • 박정호;김종관;김상영;성영권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1025-1027
    • /
    • 1995
  • SEG(Selective Epitaxial Growth) and ELO(Epitaxial Lateral Growth) of Silicon offer new opportunities in the fabrication of MEMS(Micro Electro-Mechanical Systems) structures. SEG of silicon enables the stacking of junctions in addition to those resulting from the standard bipolar process and this properly was utilized for the fabrication of an improved-performance color sensor. When the crystalline growth takes place through the seed windows and proceeds over the dielectric, after reaching the surface, it form an ELO silicon layer and this ELO-Si can be modified into various structures for MEMS application such as cantilevers, beams, diaphragms.

  • PDF