• Title/Summary/Keyword: cam

Search Result 2,827, Processing Time 0.034 seconds

Color stability of 3D-printed denture resins: effect of aging, mechanical brushing and immersion in staining medium

  • Alfouzan, Afnan Fouzan;Alotiabi, Hadeel Minife;Labban, Nawaf;Al-Otaibi, Hanan Nejer;Taweel, Sara Mohammad Al;AlShehri, Huda Ahmed
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.3
    • /
    • pp.160-171
    • /
    • 2021
  • Purpose. This in-vitro study evaluated and compared the color stability of 3D-printed and conventional heat-polymerized acrylic resins following aging, mechanical brushing, and immersion in staining medium. Materials and methods. Forty disc-shaped specimens (10 mm in diameter and 3 mm thick) were prepared from two 3D-printed [DentaBASE (DB) and Denture 3D+ (D3D)] and one conventional polymethylmethacrylate (PMMA) denture materials. The specimens were thermo-cycled, subjected to mechanical brushing, and were immersed in either coffee, lemon juice, coke, or artificial saliva (AS) to simulate one and two years of oral use. Color measurements of the specimens were recorded by a spectrophotometer at baseline (T0), and after one (T1) and two years (T2) of simulation. The color changes (ΔE) were determined and also quantified according to the National Bureau of Standards (NBS) units. Descriptive statistics, followed by factorial ANOVA and Bonferroni post-hoc test (α=.05), were applied for data analysis. Results. The independent factors, namely material, staining medium, and immersion time, and interaction among these factors significantly influenced ΔE (P<.009). Irrespective of the materials, treatments, and time, the highest and the lowest mean ΔEs were observed for PMMA in lemon juice (4.58 ± 1.30) and DB in AS (0.41 ± 0.18), respectively. Regarding the material type, PMMA demonstrated the highest mean ΔE (2.31 ± 1.37), followed by D3D (1.67 ± 0.66), and DB (0.85 ± 0.52), and the difference in ΔE between the materials were statistically significant (P<.001). All the specimens demonstrated a decreased color changes at T2 compared to T1, and this difference in mean ΔE was statistically significant (P<.001). Conclusion. The color changes of 3D-printed denture resins were low compared to conventional heat polymerized PMMA. All the tested materials, irrespective of the staining medium used, demonstrated a significant decrease in ΔE values over time.

A Maryblyt Study to Apply Integrated Control of Fire Blight of Pears in Korea (배 화상병 종합적 방제를 위한 Maryblyt 활용 방안 연구)

  • Kyung-Bong, Namkung;Sung-Chul, Yun
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.24 no.4
    • /
    • pp.305-317
    • /
    • 2022
  • To investigate the blossom infection risk of fire blight on pears, the program Maryblyt has been executed from 2018 to 2022 based on meteorological data from central-Korean cities where fire blight has occurred as well as from southern Korean cities where the disease has not yet occurred. In the past five years, years with the highest risk of pear blossom blight were 2022 and 2019. To identify the optimal time for spraying, we studied the spray mode according to the Maryblyt model and recommend spraying streptomycin on the day after a "High" warning and then one day before forecasted precipitation during the blossom period. Maryblyt also recommends to initiate surgical controls from mid-May for canker blight symptoms on pear trees owing to over-wintering canker in Korea. Web-cam pictures from pear orchards at Cheonan, Icheon, Sangju, and Naju during the flowering period of pear trees were used for comparing real data and constructing a phenological model. The actual starting dates of flowering at southern cities such as Sangju and Naju were consistently earlier than those calculated by the model. It is thus necessary to improve the forecasting model to include field risks by recording the actual flowering period and the first day of the fire blight symptoms, according to the farmers, as well as mist or dew-fall, which are not easily identifiable from meteorological records.

Test Set Construction for Quality Evaluation of NAK Portal's Search Service and the Status Analysis (국가기록포털 검색서비스 품질 점검을 위한 평가셋 구축 및 현황 분석)

  • Jeong Ho, Na;Hyeon-Gi, So;Gyung Rok, Yeom;Jung-Ok, Lee;Hyo-Jung, Oh
    • Journal of Korean Society of Archives and Records Management
    • /
    • v.22 no.4
    • /
    • pp.25-43
    • /
    • 2022
  • The ultimate record management's purpose is preservation and utilization. However, the National Archives of Korea (NAK)s Portal has problems such as search system aging and search tools dualization. As a result, the users' search satisfaction is not satisfied, and the improvement demand increases. This study aimed to evaluate the NAK's search quality as a preliminary study for NAK search system advancement. To this end, we analyzed the current status of CAMS and NAK's Portal. Then, we established the test sets and evaluated the NAK's Portal quality from the user's point of view. Evaluation results were analyzed using Precision, Recall, F-score, and MRR. The analysis results showed that the overall search performance was low, particularly in the "advanced subject search," which showed low performance in Precision, Recall, and MRR. Thus, improvement is urgently needed. The test sets established for this study are expected to be used as a basis for objectively measuring the improvement of the search performance after the NAK search system advancement.

Implant surgery and prosthodontic treatment of Temporomandibular disorder patient combined SERAFIN clear aligner system : Clinical case report (세라핀 투명교정 시스템을 활용한 교합 장애 및 치아 결손 증례의 치료)

  • Won-Gun, Chang
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.31 no.1
    • /
    • pp.11-18
    • /
    • 2022
  • Adult patients who need implant and prosthodontic treatment often need treatment to improve the existing occlusion through orthodontic treatment for long-term stable treatment results. However, due to non-aesthetic and uncomfortable orthodontic treatment with orthodontic brackets and wires, many adult patients give up treatment even though they know the need for it. Recently, as digital dentistry has affected all areas of dentistry, clear aligner orthodontic systems have begun to be widely used, and their use is increasing in adults and old-aged people due to the esthetic advantage and convenient oral care. SERAFIN clear aligner system developed in Korea has been developed with the aim of implementing a functional occlusion harmony and is used not only for partial orthodontic treatment but also comprehensive orthodontic treatment. This patient presentation is shown the treatment using SERAFIN clear aligner system for the treatment of patient with TMD, severe extrusion of maxillary second molars, and extracted teeth.

Digital technique in diagnosis and restoration of maxillary anterior implant: a case report (디지털 기법을 활용한 상악 전치부의 진단 및 수복 증례)

  • Haemin, Bang;Woohyung, Jang;Chan, Park;Kwi-Dug, Yun;Hyun-Pil, Lim;Sangwon, Park
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.4
    • /
    • pp.249-256
    • /
    • 2022
  • The implant prosthesis of anterior maxilla requires careful consideration in planning. In order to satisfy both esthetic and functional needs of a patient, fusion of intra-oral scan in Cone-beam computed tomography (CBCT) and facial scan can be considered. Bony structures and soft tissues captured in CBCT and occlusal surfaces of intra oral scan were incorporated into personal characteristics from facial scan. The patient had insufficient buccal bone on maxillary anterior area. The maxillary implants could not be placed on the most ideal position. However, the "top down" approach completed by computer-generated arranging of teeth in implant planning and surgery with surgical guide resulted in esthetically and functionally satisfying result regardless of the limitation. Careful diagnosis with digital technique and the usage of surgical guide resulted in successful surgery and esthetic restoration. The temporary fixed prostheses were designed, restored and evaluated. The patient was not satisfied with the first design of temporary prosthesis, which showed uneven space distribution between teeth due to the position of maxillary implant. The design was modified by changing proximal emergence contours and line angle to alter the perceived since of incisors. The patient was satisfied with the new design of provisional restoration. A digital occlusion analyzer (Arcus Digma II, KaVo, Leutkirch, Germany) was used to measure inherent condylar guidance and anterior guidance of a patient to provide a definitive prosthesis.

Anticancer activity of chloroform extract of Citrus unshiu Markovich peel against glioblastoma stem cells (교모세포종 암줄기세포에 대한 진피 소수성 추출물의 항암 활성)

  • Kim, Yu Jin;Sim, Ye Eun;Jung, Hye Jin
    • Korean Journal of Food Science and Technology
    • /
    • v.54 no.1
    • /
    • pp.28-34
    • /
    • 2022
  • Glioblastoma is the most common primary malignant brain tumor and has an extremely poor prognosis. Glioblastoma stem cells (GSCs) contribute to tumor initiation, recurrence, and resistance to therapy, and are thus a key therapeutic target. The peel of Citrus unshiu Markovich has been used in traditional medicine in East Asia to treat various diseases. In this study, we investigated the anticancer activity and molecular mechanism of the chloroform extract of this natural product (CECU) in U87MG GSCs. The results show that CECU inhibited the proliferation, tumorsphere formation, and migration of U87MG GSCs by causing cell cycle arrest at the G0/G1 phase and apoptosis. In addition, CECU downregulated key cancer stemness regulators, including CD133, Oct4, Nanog, integrin α6, ALDH1A1, and STAT3 signaling in U87MG GSCs. Furthermore, CECU significantly suppressed in vivo tumor growth of U87MG GSCs in a chorioallantoic membrane model. Therefore, CECU can be utilized as a natural medicine for the prevention and treatment of glioblastoma.

Full mouth rehabilitation with fixed implant-supported prosthesis using temporary denture and double digital scanning technique: a case report (임시 의치와 이중 디지털 스캐닝 기법을 활용한 전악 고정성 임플란트 수복 증례)

  • Seok-Hyun Shin;Chan-Ik Park;Se-Ha Kang;Ji-Eun Moon;Min-Seok Oh;Chul-Min Park;Woo-Jin Jeon;Seong-Gu Han;Sun-Jae Kim;Su-Jin Choi
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.245-256
    • /
    • 2023
  • When restoring with a dental digital system for implant-supported prosthesis, a double digital scanning technique is required: an intraoral scan of the three-dimensional implant location and intraoral scan after placement of temporary denture or provisional prosthesis. During the intraoral scan, the use of scan body as a stable landmark can improve the accuracy of digital impression and simplify laboratory process. In this case, a full-digital system was used to plan and fabricate a custom abutment, provisional prosthesis, and definitive prosthesis. After implant placement, the scan area of the intraoral scan body connected with implant and the intraoral scan body marked on the inside of temporary denture were superimposed. Out of the superimposed files, a custom abutment and provisional prosthesis were fabricated which match the vertical dimension of temporary denture, and definitive prosthesis was fabricated based on provisional prosthesis. We report this case because result has been functionally and esthetically satisfactory by using vertical dimension and central relation set during the fabrication of temporary denture to the definitive prosthesis.

Effect of artificial aging on mechanical and physical properties of CAD-CAM PMMA resins for occlusal splints

  • Julia Correa Raffaini;Eduardo Jose Soares;Rebeca Franco de Lima Oliveira;Rocio Geng Vivanco;Ayodele Alves Amorim;Ana Lucia Caetano Pereira;Fernanda Carvalho Panzeri Pires-de-Souza
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.5
    • /
    • pp.227-237
    • /
    • 2023
  • PURPOSE. This study aimed to assess and compare the color stability, flexural strength (FS), and surface roughness of occlusal splints fabricated from heat-cured acrylic resin, milled polymethyl methacrylate (PMMA)-based resin, and 3D-printed (PMMA) based-resin. MATERIALS AND METHODS. Samples of each type of resin were obtained, and baseline measurements of color and surface roughness were recorded. The specimens were divided into three groups (n = 10) and subjected to distinct aging protocols: thermomechanical cycling (TMC), simulated brushing (SB), and control (without aging). Final assessments of color and surface roughness and three-point bending test (ODM100; Odeme) were conducted, and data were statistically analyzed (2-way ANOVA, Tukey, P <.05). RESULTS. Across all resin types, the most significant increase in surface roughness (Ra) was observed after TMC (P < .05), with the 3D-printed resin exhibiting the lowest Ra (P < .05). After brushing, milled resin displayed the highest Ra (P < .05) and greater color alteration (∆E00) compared to 3D-printed resin. The most substantial ∆E00 was recorded after brushing for all resins, except for heat-cured resin subjected to TMC. Regardless of aging, milled resin exhibited the highest FS (P < .05), except when compared to 3D-printed resin subjected to TMC. Heat-cured resin exposed to TMC demonstrated the lowest FS, different (P < .05) from the control. Under control conditions, milled resin exhibited the highest FS, different (P < .05) from the brushed group. 3D-printed resin subjected to TMC displayed the highest FS (P < .05). CONCLUSION. Among the tested resins, 3D-printed resin demonstrated superior longevity, characterized by minimal surface roughness and color alterations. Aging had a negligible impact on its mechanical properties.

Influences of luting cement shade on the color of various translucent monolithic zirconia and lithium disilicate ceramics for veneer restorations

  • Ghada Alrabeah;Nawaf Alamro;Atif Alghamdi;Ahmed Almslam;Meshari Azaaqi
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.5
    • /
    • pp.238-247
    • /
    • 2023
  • PURPOSE. The purpose of this study was to assess the effect of resin cement shade on the color of different novel ultratranslucent monolithic zirconia and lithium disilicate veneer materials. MATERIALS AND METHODS. For a total of 40 specimens, flat cylindrical discs with a 9-mm diameter and 0.5-mm thickness were created using CAD/CAM technology. The specimens were divided into five groups according to their material (n = 8) (e.max, Prettau, Aidite, Shofu and Dima) using A1 shade. Resin discs with the same diameter and shade as the specimens served as tooth-colored substructures. Three shades (neutral, light and warm) of resin cement try-in pastes (Variolink Esthetic LC) were used as the luting cement material. The color of each material group was measured before and after cementation using the three cement shades, and the CIE L*a*b* coordinates were obtained with a spectrophotometer. Values for the translucency parameter (TP) and color change delta E (E) before (baseline) and after cementation of each specimen were determined. To compare differences among the material groups within each shade of cement and among various shades of cement within each material, the data were analyzed using one-way ANOVA and post hoc testing. RESULTS. Color coordinates L*, a* and b* significantly changed after the application of try-in pastes relative to baseline values, with a noticeable decrease in lightness (L*) (P < .05). A significant color change (ΔE) was observed in all tested materials after cementation, with ΔE values exceeding 3.3 (P < .05). Although TP changed after cementation for most materials tested, these changes were not statistically significant (P > .05). Shofu and Dima ceramics showed the lowest TP values, while Aidite and Prettau showed the highest TP values. For e.max, translucency decreased after cementation with neutral and warm shades, and it significantly increased after cementation with a light shade. CONCLUSION. The shade of cement significantly altered the final color of the ceramic veneer material to a level above the threshold at which the clinical perception of color change occurred (> 3.3). The TP was not influenced by the cement shade. The translucency levels of the novel ultratranslucent multilayer monolithic zirconia ceramics Aidite and Prettau were higher than that of the lithium disilicate e.max material.

'All-on-4' fixed implant supported prosthesis restoration using digital workflow: a case report (Digital workflow를 활용한 'All-on-4' 임플란트 지지 고정성 보철물 수복 증례)

  • Sungwoo Ju;Seoung-Jin Hong;Janghyun Paek;Kwantae Noh;Ahran Pae;Kung-Rock Kwon;Hyeong-Seob Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.316-327
    • /
    • 2023
  • In the case of fully edentulous patients with severe alveolar bone resorption, the consideration of 'All-on-X' implant-supported fixed prosthesis after placing four or more implants in the anterior maxilla is possible. Recent advancements in digital dentistry have enabled systematic and predictable treatment in all phases, including diagnosis, surgery, and prosthesis fabrication. By incorporating digital dentistry techniques such as digital complete denture, implant surgical guides, facial scanning into the conventional restoration process, it is possible to reduce the complexity of the prosthesis fabrication and effectively achieve the transition from provisional prosthesis to definitive prosthesis in terms of both aesthetics and function.