파이프 프루버의 측정불확도에 관한 연구 (A Study on the Measurement Uncertainty of Pipe Prover)

  • 임기원
    • 대한기계학회논문집B
    • /
    • 제24권10호
    • /
    • pp.1388-1398
    • /
    • 2000
  • A pipe prover is a flowmeter calibrator used in flow measurement field. Gravimetric and volumetric methods were applied to determine the basic volume of the pipe prover. Uncertainty of its basic volume measurement was evaluated in accordance with the procedure recommended by International Organization for Standardization. The combined standard uncertainty of determining the basic volume was estimated from the sensitivity coefficient and the standard uncertainty of independent variables. It was found that the uncertainties of the weighing and volume measurements have dominant influence on that of the basic volume determination. With the quantitative analysis of the sensitivity coefficient, the contribution of the each variable uncertainty to the combined standard uncertainty of the basic volume is shown clearly.

KOMPSAT-3와 Landsat-8의 시계열 융합활용을 위한 교차검보정 (Radiometric Cross Calibration of KOMPSAT-3 and Lnadsat-8 for Time-Series Harmonization)

  • 안호용;나상일;박찬원;홍석영;소규호;이경도
    • 대한원격탐사학회지
    • /
    • 제36권6_2호
    • /
    • pp.1523-1535
    • /
    • 2020
  • 원격탐사를 이용한 작황정보 생산은 작물의 생물계절을 이용하여 작물 분류, 생육 모니터링, 생산량 추정 분석이 선행되어야 한다. 생물계절에 추정을 위한 시계열 영상 자료가 필요하지만 KOMPSAT(Korea Multi-Purpose Satellite)만으로 획득하는 것은 물리적 제한이 있으므로 타 지구관측위성과의 융합 활용이 필요하다. 위성자료의 융합 활용을 위해서는 각 위성이 가지는 고유의 방사학적 센서 특성 차이를 극복해야 한다. 본 연구는 위성자료의 융·복합 활용을 위한 첫 단계로서 KOMPSAT-3와 Landsat-8 위성의 교차검보정을 수행하였다. Libya-4 PICS(Pseudo Invariant Calibration Sites)에서 2년간 수집된 위성자료에 대해 초분광위성을 이용하여 산정된 SBAF(Spectral Band Adjustment Factor)를 적용하여 대기상단 반사도를 비교하였다. 교차검보정 결과 KOMPSAT-3와 Landsat-8 위성은 Blue, Green, Red 밴드에서 약 4%, NIR밴드에서 6%의 반사율 차이를 보였다. 온보드 켈리브레이터가 없는 KOMPSAT-3는 Ladnsat-8에 비해 Radiometric Stability가 낮은 것으로 나타났다. 향후 교차검보정의 정확도를 높이기 위해 BRDF(Bidirectional reflectance distribution function) 보정 및 지형보정을 통하여 정규화 된 반사율 자료를 생산하기 위한 노력이 필요하다.

Optical Multi-Channel Intensity Interferometry - or: How To Resolve O-Stars in the Magellanic Clouds

  • Trippe, Sascha;Kim, Jae-Young;Lee, Bangwon;Choi, Changsu;Oh, Junghwan;Lee, Taeseok;Yoon, Sung-Chul;Im, Myungshin;Park, Yong-Sun
    • 천문학회보
    • /
    • 제39권2호
    • /
    • pp.111-111
    • /
    • 2014
  • Intensity interferometry, based on the Hanbury Brown--Twiss effect, is a simple and inexpensive method for optical interferometry at microarcsecond angular resolutions. Motivated by recent technical developments, we argue that the sensitivity of large modern intensity interferometers can be improved by factors up to approximately 25,000, corresponding to 11 photometric magnitudes, compared to the pioneering Narrabri Stellar Interferometer of the 1970s when resolving. Our approach, based on spectrally resolved light, permits the construction of large optical interferometers at the cost of (very) long-baseline radio interferometers. Realistic intensity interferometers are able to spatially resolve main-sequence O-type stars in the Magellanic Clouds. Multi-channel intensity interferometers can address a wide variety of science cases: (i) linear radii, effective temperatures, and luminosities of stars; (ii) mass-radius relationships of compact stellar remnants; (iii) stellar rotation; (iv) stellar convection and the interaction of stellar photospheres and magnetic fields; (v) the structure and evolution of multiple stars; (vi) direct measurements of interstellar distances; (vii) the physics of gas accretion onto supermassive black holes; and (viii) calibration of amplitude interferometers by providing a sample of calibrator stars.

  • PDF

소형 코리올리 질량 유량계의 개발 (Development of Small Size Coriolis Mass Flowmeter)

  • 임기원;지정근
    • 대한기계학회논문집B
    • /
    • 제30권6호
    • /
    • pp.497-504
    • /
    • 2006
  • A Coriolis mass flowmeter(CMF), which has U-Shaped unique measurins tube was developed fo. direct mass flow measurement. In order to convert the time difference between two measuring tubes motion into mass flowrate and flow quantity, a signal processing circuit, as a part of CMF, was also developed. The CMF was designed as the 15 mm nominal diameter of pipe connection and the 8 mm stainless steel(sus 316) pipe was used for measuring tube. To maximize the flow signal(time difference) from the measuring tubes, the natural frequency of measuring tube was adjusted as 220 Hz, which is same as the frequency of exciter. The maximum displacement at the end of the measuring tube was measured as 0.05 mm and the maximum time difference between two measuring tubes was observed as $20{\mu}s$, which was proper for discrimination and measuring range of CMF. The developed CMF was tested against the gravimetric flowmeter calibrator in the range of 3 kg/min and 30 kg/min. The results showed that the CMF has good linearity and repeatability in the tested flow range. Large size of CMF base on the current study experience will be developed.

Search for Very Fast Variability in AGN Radio Light Curves

  • 이태석;;손봉원;이상성;변도영;오정환
    • 천문학회보
    • /
    • 제38권1호
    • /
    • pp.43.1-43.1
    • /
    • 2013
  • We present here the preliminary results of the fast variability of AGN radio light curves. The shortest time scale of minute in AGN light curves is needed to probe the AGN activity for a few reasons; First, to check if there is any kind of shortest time scale activity. Secondly, to find out what high frequency end of AGN spectra look like. For the last, to see the time delay at several wavelength bands and the change of the spectral index with time. The observation was conducted with three KVN(Korea VLBI Network) antennas with single dish cross scan mode. In order not to lose the target at any given time, whenever one station needs to observe the calibrator, the other station is on the target. Though the detailed data reduction is still going on, there might exist varying feature in the radio light curve. The more fine calibration will be done in near future and another good data set is ready for the reduction.

  • PDF

머신러닝 기반 고용량 I-131의 용량 예측 모델에 관한 연구 (A Study on Predictive Modeling of I-131 Radioactivity Based on Machine Learning)

  • 유연욱;이충운;김정수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권2호
    • /
    • pp.131-139
    • /
    • 2023
  • High-dose I-131 used for the treatment of thyroid cancer causes localized exposure among radiology technologists handling it. There is a delay between the calibration date and when the dose of I-131 is administered to a patient. Therefore, it is necessary to directly measure the radioactivity of the administered dose using a dose calibrator. In this study, we attempted to apply machine learning modeling to measured external dose rates from shielded I-131 in order to predict their radioactivity. External dose rates were measured at 1 m, 0.3 m, and 0.1 m distances from a shielded container with the I-131, with a total of 868 sets of measurements taken. For the modeling process, we utilized the hold-out method to partition the data with a 7:3 ratio (609 for the training set:259 for the test set). For the machine learning algorithms, we chose linear regression, decision tree, random forest and XGBoost. To evaluate the models, we calculated root mean square error (RMSE), mean square error (MSE), and mean absolute error (MAE) to evaluate accuracy and R2 to evaluate explanatory power. Evaluation results are as follows. Linear regression (RMSE 268.15, MSE 71901.87, MAE 231.68, R2 0.92), decision tree (RMSE 108.89, MSE 11856.92, MAE 19.24, R2 0.99), random forest (RMSE 8.89, MSE 79.10, MAE 6.55, R2 0.99), XGBoost (RMSE 10.21, MSE 104.22, MAE 7.68, R2 0.99). The random forest model achieved the highest predictive ability. Improving the model's performance in the future is expected to contribute to lowering exposure among radiology technologists.

OPTICAL MULTI-CHANNEL INTENSITY INTERFEROMETRY - OR: HOW TO RESOLVE O-STARS IN THE MAGELLANIC CLOUDS

  • Trippe, Sascha;Kim, Jae-Young;Lee, Bangwon;Choi, Changsu;Oh, Junghwan;Lee, Taeseok;Yoon, Sung-Chul;Im, Myungshin;Park, Yong-Sun
    • 천문학회지
    • /
    • 제47권6호
    • /
    • pp.235-253
    • /
    • 2014
  • Intensity interferometry, based on the Hanbury Brown-Twiss effect, is a simple and inexpensive method for optical interferometry at microarcsecond angular resolutions; its use in astronomy was abandoned in the 1970s because of low sensitivity. Motivated by recent technical developments, we argue that the sensitivity of large modern intensity interferometers can be improved by factors up to approximately 25 000, corresponding to 11 photometric magnitudes, compared to the pioneering Narrabri Stellar Interferometer. This is made possible by (i) using avalanche photodiodes (APD) as light detectors, (ii) distributing the light received from the source over multiple independent spectral channels, and (iii) use of arrays composed of multiple large light collectors. Our approach permits the construction of large (with baselines ranging from few kilometers to intercontinental distances) optical interferometers at the cost of (very) long-baseline radio interferometers. Realistic intensity interferometer designs are able to achieve limiting R-band magnitudes as good as $m_R{\approx}14$, sufficient for spatially resolved observations of main-sequence O-type stars in the Magellanic Clouds. Multi-channel intensity interferometers can address a wide variety of science cases: (i) linear radii, effective temperatures, and luminosities of stars, via direct measurements of stellar angular sizes; (ii) mass-radius relationships of compact stellar remnants, via direct measurements of the angular sizes of white dwarfs; (iii) stellar rotation, via observations of rotation flattening and surface gravity darkening; (iv) stellar convection and the interaction of stellar photospheres and magnetic fields, via observations of dark and bright starspots; (v) the structure and evolution of multiple stars, via mapping of the companion stars and of accretion flows in interacting binaries; (vi) direct measurements of interstellar distances, derived from angular diameters of stars or via the interferometric Baade-Wesselink method; (vii) the physics of gas accretion onto supermassive black holes, via resolved observations of the central engines of luminous active galactic nuclei; and (viii) calibration of amplitude interferometers by providing a sample of calibrator stars.

KOLAS 교정기관의 측정동등성 확립을 위한 물유량 숙련도 시험 (Proficiency Test of Water Flow Rate for Measurement Equivalence Among KOLAS Accredited Laboratories)

  • 전세종;윤병로;김수진
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제5권2호
    • /
    • pp.105-113
    • /
    • 2017
  • 한국인정기구(KOLAS)는 아시아태평양인정협의체(APLAC)에 소속되어 있으며, 측정 결과를 SI 단위로 소급하고 이를 유지시키기 위해 교정기관 인정제도를 운영하고 있다. 2016 년 6 월 현재, 22 개의 기관이 KOLAS 물유량 분야 교정기관으로 지정되어 있다. 이 중 12 개 KOLAS 교정기관들이 한국계량측정협회(KASTO)가 2015 년에 주관한 물유량 숙련도 시험(PM2015-08)에 참가했다. 이번 숙련도 시험은 KOLAS 교정기관들의 교정측정능력(CMC)을 고려하여 3 가지의 유량 범위($3.6m^3/h{\sim}12m^3/h$, $40m^3/h{\sim}80m^3/h$, $40m3/h{\sim}200m^3/h$)에서 실시되었다. 숙련도 시험의 목적은 참가기관들의 CMC 가 기준시험소(KRISS)의 CMC 와 비교하여 측정동등성이 성립하는지 여부를 판단하기 위한 것이다. 측정동등성은 측정동등성지수(number of equivalence; $E_n$)를 산출하여 평가했다. ${\mid}E_n{\mid}$ < 1 일 때, 측정동등성이 확립된다고 판단했다. 이번 시험에서 12 개 KOLAS 교정기관 모두 기준시험소와 측정동등성이 성립함을 확인했다.

PET/CT 검사에서 매개변수 입력오류에 따른 표준섭취계수 평가 (The Evaluation of SUV Variations According to the Errors of Entering Parameters in the PET-CT Examinations)

  • 김지아;홍건철;이혁;최성욱
    • 핵의학기술
    • /
    • 제18권1호
    • /
    • pp.43-48
    • /
    • 2014
  • PET/CT검사에서 표준섭취계수(standardized uptake value, SUV)는 병소의 악성 여부를 판별하는 지표로서 인체내 각 장기의 생리적인 변화에 대한 정량분석을 가능하게 한다. 따라서 그 결과에 영향을 줄 수 있는 매개변수를 올바르게 입력하는 것이 매우 중요하다. 본 연구에서는 그 매개변수 중 방사능량, 체중, 방사성 동위원소 섭취시간의 입력오류에 따른 결과의 차이를 측정하여 수용 가능한 결과의 오차범위를 평가하고자 한다. 1994 NEMA 모형 내부에 열소, 테프론, 그리고 공기 3개의 삽입물을 위치시켰다. 총 27.3 MBq의 $^{18}F$를 열소와 배후 방사능 비율이 4:1로 되도록 채우고 GE Discovery STE 16(GE Healthcare, Milwaukee, USA)로 촬영하였다. 촬영 후 입력된 방사능량, 체중, 섭취 시간의 값을 기준 값에서 ${\pm}5%$, 10%, 15%, 30%, 50% 만큼 오차를 발생시킨 후 영상을 다시 재구성하였다. 재구성된 영상에서 각 삽입물 부위에 한 개, 배후방사능 부위에 총 네 개의 관심영역을 그린 후 $SUV_{mean}$과 백분율오차를 측정하여 비교 평가하였다. 기준 영상의 열소, 테프론 그리고 공기와 배후방사능에서의 $SUV_{mean}$은 각각 4.5, 0.02, 0.1 그리고 1.0이였다. 방사능량 오차 변화에 따른 $SUV_{mean}$의 최대값과 최소값은 열소에서 9.0, 3.0, 테프론에서 0.04, 0.01, 공기에서 0.3, 0.1, 배후 방사능에서 2.0, 0.6로 변화된 값을 보였다. 이 때 백분율오차는 모두 동일하게 최대 100%에서 최소 -33%로 나타났다. 체중 오차 변화의 경우 열소에서 2.2, 6.7, 테프론에서 0.01, 0.03, 공기에서 0.09. 0.28, 배후방사능에서 0.5, 1.5로 변화된 값을 보였다. 이 때 백분율오차는 테프론의 최소 -50%, 최대 52%를 제외하고 모두 최소 -50%에서 최대 50% 로 동일하게 나타났다. 섭취시간 오차의 경우 열소에서 3.8, 5.3, 테프론에서 0.01, 0.02, 공기에서 0.1, 0.2, 배후방사능에서 0.8에서 1.2로 변화된 값을 보였다. 백분율오차는 열소와 배후방사능은 최소 -14%에서 최대 17%로 동일하게 나타났으며 테프론의 경우 최소 -11%에서 최대 21%, 공기의 경우 최소 -12%에서 최대 20%로 나타났다. 일반적으로 수용 가능한 오차의 범위를 5%로 설정할 경우, 본 실험 결과에서 방사능량과 체중의 오차가 ${\pm}5%$ 이내 일 때 $SUV_{mean}$의 오차가 5% 범위에 포함되었다. 이러한 결과들을 고려해 볼 때 검사장비에 입력되는 방사능량과 체중에 직접적인 영향을 줄 수 있는 선량검량계와 체중계의 검교정은 오차범위 5% 이내로 이루어져야 한다. 섭취 시간의 경우 삽입물의 종류에 따라 서로 다른 오차 범위를 보였으며 열소와 배후방사능에서 오차가 ${\pm}15%$ 이내일 때 $SUV_{mean}$에 5% 내의 오차가 발생하였다. 따라서 검사 시 촬영용 스캐너를 포함하여 두 개 이상의 시계를 사용할 경우 각각의 시간 오차들도 함께 고려되어야 할 것이다.

  • PDF