• Title/Summary/Keyword: calibration system

Search Result 2,067, Processing Time 0.033 seconds

A Comparative Study of Branching Ratio of 167Yb Radioactive Isotope from Gamma-ray Spectrum Produced by 169Tm(p,3n)167Yb Reaction with 100-MeV Proton Beam (100-MeV 양성자 빔을 이용하여 169Tm(p,3n)167Yb 반응에 의해 생성된 167Yb 방사성동위원소에서 방출되는 감마선 스펙트럼 비교 연구)

  • Sam-Yol, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.953-960
    • /
    • 2022
  • The measurement of branching ratio of 167Yb radioactive isotopes from gamma-ray spectrum of 169Tm(p,3n)167Yb reaction were performed by using a 100-MeV proton linear accelerator of the Korea Multi-purpose Accelerator Complex (KOMAC). The 167Yb isotope has a half-life of 17.5 minutes and decays to 169Tm. The gamma rays generated from the 167Yb isotope were measured using an HPGe detector gamma ray spectroscopy system. The energy calibration of the detector and the efficiency measurement of the detector were determined using a standard source. The gamma rays of known main energy (62.9, 106.2, 113.3, 143.5 and 176.3 keV) were measured. On the other hand, information about the intensity of the generated gamma rays is very inaccurate. Therefore, in this study, the decay strength of the main gamma rays was accurately measured. Overall, it was different from the previously known results, and in particular, it was found that the intensity of the main decay gamma ray, such as the 113.3 and 106.2 keV gamma ray, was overestimated, and it was found that the gamma ray, such as 62.9, 116.7 and 143.5 keV was underestimated. The present results are considered to be important information in the fields of nuclear fusion, astrophysics and nuclear physics in the future.

Use of Near Infrared Reflectance Spectroscopy for Determination of Grain Components in Barley (보리종실 성분분석을 위한 근적외선분광광도계의 이용방법)

  • Kim, Byung-Joo;Park, Eui-Ho;Suh, Hyung-Soo
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.40 no.6
    • /
    • pp.716-722
    • /
    • 1995
  • Near Infrared Reflectance Spectroscopy (NIRS) has been used as a tool for the rapid, accurate and nondestructive assay of small grain and forage quality analysis. The objective of this study was to establish the rapid, easy and accurate analysis method for major components of covered barley using NIRS system. NIRS used in this study was filter type instrument, Neotec 102. To obtain a useful calibration equation, standard regression between the data was analyzed by chemical analysis and by NIRS method. Standard errors of prediction (SEP) and simple correlations for unknown samples were calculated using obtained equation. SEPs for starch, $\beta$-glucan, protein and ash contents were 2.75%, 0.64%, 0.26% and 0.19%, respectively. The simple correlations for starch, $\beta$-glucan, protein and ash contents were 0.932, 0.588, 0.984 and 0.867, respectively. It was concluded that the NIRS method would be applicabl for the rapid determination of starch, protein and ash contents in barley grains.

  • PDF

Determination of trace arsenic in seawater by flow injection-hydride generation inductively coupled plasma mass spectrometry (연속흐름주입-수소화물생성-유도결합플라스마 질량분석장치를 이용한 바닷물표준시료중의 극미량 비소분석방법의 확립)

  • Suh, Jung-Ki
    • Analytical Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.316-325
    • /
    • 2008
  • An inductively coupled plasma mass spectrometry (ICP-MS) instrument equipped with flow injection-hydride generation system was used for the determination of trace arsenic in seawater sample. The accuracy in this method was verified by the analysis of certified reference materials (CRM) of seawater (CASS-4, NASS-5). The analytical results agreed with certified value within the range of uncertainty. The expanded uncertainties for CASS-4 and NASS-5 in this experiment were ranged from 6.2% to 6.8% obtained from repeated analyses of the CRMs (n=5). The detection limit of $As^+$ (m/z=74.9216) in this method was confirmed about 0.01 ug/kg. Linearity obtained from calibration curve of arsenic was excellent ($R^2=1$). The detection at $As^+$ (m/z=74.9216) and $AsO^+$ (m/z=90.9165) by using oxygen reaction gas in DRC mode was compared. Sensitivity at $AsO^+$ (m/z=90.9165) was decreased about 25-fold, but the analytical results are the same that at $As^+$ (m/z=74.9216).

Simultaneous determination of amphetamine-like drugs in human urine by SPE and GC/MS (고체상추출과 GC/MS를 이용한 소변 중 암페타민계 마약성분 동시분석법)

  • Cheong, Jae Chul;Kim, Jin Young;In, Moon Kyo;Cheong, Won Jo
    • Analytical Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.41-47
    • /
    • 2008
  • Although liquid-liquid extraction (LLE) method has been used routinely for the analysis of amphetamine-like drugs (amphetamine; AP, methamphetamine; MA, 3,4-methylenedioxyamphetamine; MDA, 3,4-methylenedioxymethamphetamine; MDMA, 3,4-methylenedioxyethylamphetamine; MDEA), a solid-phase extraction (SPE) method, which can be automated, was applied for the simultaneous determination by GC/MS in human urine. Urine samples (3 mL) and 0.1 M phosphate buffer (1 mL, pH 7.0) were extracted by an automated SPE system. The eluent was evaporated, derivatized with trifluoroacetic anhydride (TFAA), and analyzed by GC/MS. The calibration curves was linear with correlation coefficient ($r^2$) above 0.994 in the ranges of 34.0 (AP), 28.0 (MDA)~1000.0 ng/mL for AP, MDA, and 50.0~2000.0 ng/mL for MA, MDMA, and MDEA. The limits of detection ranged from 4.0 to 10.0 ng/mL, and the limits of quantitation ranged from 12.0 to 34.0 ng/mL. The relative recoveries were 93.5~107.7 %. The precisions and accuracies were 1.9~14.8 % and -8.7~14.8 %, respectively. The present method was successfully applied to identify the MA or Ecstasy (MDMA) abusers in exact as well as rapid.

An Experiment on Redundancy in Continuous Span Two-Girder Bridge - Effects of Lateral Bracing (연속 2-거더교의 여유도 평가 실험 - 수평브레이싱의 효과)

  • Park, Yong-Myung;Joe, Woom-Do-Ji;Hwang, Min-Oh;Yoon, Tae-Yang
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4A
    • /
    • pp.417-429
    • /
    • 2008
  • This paper presents an experimental result to evaluate the redundancy in continuous span two plate-girder bridges which are generally classified as a non-redundant load path structure. The experiments were performed when one of the two girders is seriously cracked. To estimate the effects of bottom lateral bracing on the redundancy, the experiment variable was considered as the bottom lateral bracing, and two 1/5-scaled bridge specimens with and without lateral bracing system were fabricated. The ultimate loading tests were conducted on the damaged specimens with an induced crack at a girder in the side span. The test results showed that the load carrying capacity of damaged specimen with bracing was about 1.2 times higher than that without bracing. To evaluate the redundancy in each specimen, numerical analysis was performed to calibrate the difference of dead load between the actual bridge and the test specimens. When the dead load calibration is considered, the results showed that a continuous span two-girder bridges have a reasonable redundancy even without lateral bracing. Especially, the level of redundancy is increased by about 1.8 times when the lateral bracing is provided.

Quality Reporting of Radiomics Analysis in Mild Cognitive Impairment and Alzheimer's Disease: A Roadmap for Moving Forward

  • So Yeon Won;Yae Won Park;Mina Park;Sung Soo Ahn;Jinna Kim;Seung-Koo Lee
    • Korean Journal of Radiology
    • /
    • v.21 no.12
    • /
    • pp.1345-1354
    • /
    • 2020
  • Objective: To evaluate radiomics analysis in studies on mild cognitive impairment (MCI) and Alzheimer's disease (AD) using a radiomics quality score (RQS) system to establish a roadmap for further improvement in clinical use. Materials and Methods: PubMed MEDLINE and EMBASE were searched using the terms 'cognitive impairment' or 'Alzheimer' or 'dementia' and 'radiomic' or 'texture' or 'radiogenomic' for articles published until March 2020. From 258 articles, 26 relevant original research articles were selected. Two neuroradiologists assessed the quality of the methodology according to the RQS. Adherence rates for the following six key domains were evaluated: image protocol and reproducibility, feature reduction and validation, biologic/clinical utility, performance index, high level of evidence, and open science. Results: The hippocampus was the most frequently analyzed (46.2%) anatomical structure. Of the 26 studies, 16 (61.5%) used an open source database (14 from Alzheimer's Disease Neuroimaging Initiative and 2 from Open Access Series of Imaging Studies). The mean RQS was 3.6 out of 36 (9.9%), and the basic adherence rate was 27.6%. Only one study (3.8%) performed external validation. The adherence rate was relatively high for reporting the imaging protocol (96.2%), multiple segmentation (76.9%), discrimination statistics (69.2%), and open science and data (65.4%) but low for conducting test-retest analysis (7.7%) and biologic correlation (3.8%). None of the studies stated potential clinical utility, conducted a phantom study, performed cut-off analysis or calibration statistics, was a prospective study, or conducted cost-effectiveness analysis, resulting in a low level of evidence. Conclusion: The quality of radiomics reporting in MCI and AD studies is suboptimal. Validation is necessary using external dataset, and improvements need to be made to feature reproducibility, feature selection, clinical utility, model performance index, and pursuits of a higher level of evidence.

The Research on Recommender for New Customers Using Collaborative Filtering and Social Network Analysis (협력필터링과 사회연결망을 이용한 신규고객 추천방법에 대한 연구)

  • Shin, Chang-Hoon;Lee, Ji-Won;Yang, Han-Na;Choi, Il Young
    • Journal of Intelligence and Information Systems
    • /
    • v.18 no.4
    • /
    • pp.19-42
    • /
    • 2012
  • Consumer consumption patterns are shifting rapidly as buyers migrate from offline markets to e-commerce routes, such as shopping channels on TV and internet shopping malls. In the offline markets consumers go shopping, see the shopping items, and choose from them. Recently consumers tend towards buying at shopping sites free from time and place. However, as e-commerce markets continue to expand, customers are complaining that it is becoming a bigger hassle to shop online. In the online shopping, shoppers have very limited information on the products. The delivered products can be different from what they have wanted. This case results to purchase cancellation. Because these things happen frequently, they are likely to refer to the consumer reviews and companies should be concerned about consumer's voice. E-commerce is a very important marketing tool for suppliers. It can recommend products to customers and connect them directly with suppliers with just a click of a button. The recommender system is being studied in various ways. Some of the more prominent ones include recommendation based on best-seller and demographics, contents filtering, and collaborative filtering. However, these systems all share two weaknesses : they cannot recommend products to consumers on a personal level, and they cannot recommend products to new consumers with no buying history. To fix these problems, we can use the information which has been collected from the questionnaires about their demographics and preference ratings. But, consumers feel these questionnaires are a burden and are unlikely to provide correct information. This study investigates combining collaborative filtering with the centrality of social network analysis. This centrality measure provides the information to infer the preference of new consumers from the shopping history of existing and previous ones. While the past researches had focused on the existing consumers with similar shopping patterns, this study tried to improve the accuracy of recommendation with all shopping information, which included not only similar shopping patterns but also dissimilar ones. Data used in this study, Movie Lens' data, was made by Group Lens research Project Team at University of Minnesota to recommend movies with a collaborative filtering technique. This data was built from the questionnaires of 943 respondents which gave the information on the preference ratings on 1,684 movies. Total data of 100,000 was organized by time, with initial data of 50,000 being existing customers and the latter 50,000 being new customers. The proposed recommender system consists of three systems : [+] group recommender system, [-] group recommender system, and integrated recommender system. [+] group recommender system looks at customers with similar buying patterns as 'neighbors', whereas [-] group recommender system looks at customers with opposite buying patterns as 'contraries'. Integrated recommender system uses both of the aforementioned recommender systems to recommend movies that both recommender systems pick. The study of three systems allows us to find the most suitable recommender system that will optimize accuracy and customer satisfaction. Our analysis showed that integrated recommender system is the best solution among the three systems studied, followed by [-] group recommended system and [+] group recommender system. This result conforms to the intuition that the accuracy of recommendation can be improved using all the relevant information. We provided contour maps and graphs to easily compare the accuracy of each recommender system. Although we saw improvement on accuracy with the integrated recommender system, we must remember that this research is based on static data with no live customers. In other words, consumers did not see the movies actually recommended from the system. Also, this recommendation system may not work well with products other than movies. Thus, it is important to note that recommendation systems need particular calibration for specific product/customer types.

Comparison of using CBCT with CT Simulator for Radiation dose of Treatment Planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Kim, Dae-Young;Choi, Ji-Won;Cho, Jung-Keun
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.742-749
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

Evaluation of Radiation Dose for Dual Energy CBCT Using Multi-Grid Device (에너지 변조 필터를 이용한 이중 에너지 콘빔 CT의 선량 평가)

  • Ju, Eun Bin;Ahn, So Hyun;Cho, Sam Ju;Keum, Ki Chang;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.31-36
    • /
    • 2016
  • The paper discusses radiation dose of dual energy CT on which copper modulation layer, is mounted in order to improve diagnostic performance of the dual energy CT. The radiation dose is estimated using MCNPX and its results are compared with that of the conventional dual energy CT system. CT X-ray spectra of 80 and 120 kVp, which are usually used for thorax, abdominal, head, and neck CT scans, were generated by the SPEC78 code and were used for the source specification 'SDEF' card for MCNPX dose modeling. The copper modulation layer was located 20 cm away from a source covering half of the X-ray window. The radiation dose was measured as changing its thickness from 0.5 to 2.0 mm at intervals of 0.5 mm. Since the MCNPX tally provides only normalized values to a single particle, the dose conversion coefficients of F6 tally for the modulation layer-based dual energy CBCT should be calculated for matching the modeling results into the actual dose. The dose conversion coefficient is $7.2*10^4cGy/output$ that is obtained from dose calibration curve between F6 tally and experimental results in which GAFCHORMIC EBT3 films were exposed by an already known source. Consequently, the dose of the modulation layer-based dual energy cone beam CT is 33~40% less than that of the single energy CT system. On the basis of the results, it is considered that scattered dose produced by the copper modulation layer is very small. It shows that the modulation layer-based dual energy CBCT system can effectively reduce radiation dose, which is the major disadvantage of established dual energy CT.

The Preparation of Magnetic Chitosan Nanoparticles with GABA and Drug Adsorption-Release (GABA를 담지한 자성 키토산 나노입자 제조와 약물의흡수 및 방출 연구)

  • Yoon, Hee-Soo;Kang, Ik-Joong
    • Korean Chemical Engineering Research
    • /
    • v.58 no.4
    • /
    • pp.541-549
    • /
    • 2020
  • The Drug Delivery System (DDS) is defined as a technology for designing existing or new drug formulations and optimizing drug treatment. DDS is designed to efficiently deliver drugs for the care of diseases, minimize the side effects of drug, and maximize drug efficacy. In this study, the optimization of tripolyphosphate (TPP) concentration on the size of Chitosan nanoparticles (CNPs) produced by crosslinking with chitosan was measured. In addition, the characteristics of Fe3O4-CNPs according to the amount of iron oxide (Fe3O4) were measured, and it was confirmed that the higher the amount of Fe3O4, the better the characteristics as a magnetic drug carrier were displayed. Through the ninhydrin reaction, a calibration curve was obtained according to the concentration of γ-aminobutyric acid (GABA) of Y = 0.00373exp(179.729X)-0.0114 (R2 = 0.989) in the low concentration (0.004 to 0.02 wt%) and Y = 21.680X-0.290 (R2 = 0.999) in the high concentration (0.02 to 0.1 wt%). Absorption was constant at about 62.5% above 0.04 g of initial GABA. In addition, the amount of GABA released from GABA-Fe3O4-CNPs over time was measured to confirm that drug release was terminated after about 24 hr. Finally, GABA-Fe3O4-CNPs performed under the optimal conditions were spherical particles of about 150 nm, and it was confirmed that the properties of the particles appear well, indicating that GABA-Fe3O4-CNPs were suitable as drug carriers.