• Title/Summary/Keyword: calibration equation

Search Result 312, Processing Time 0.022 seconds

Reliability Based Stability Analysis and Design Criteria for Reinforced Concrete Retaining Wall (신뢰성(信賴性) 이론(理論)에 의한 R.C.옹벽(擁壁)의 안정해석(安定解析) 및 설계규준(設計規準))

  • Cho, Tae Song;Cho, Hyo Nam;Chun, Chai Myung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.3 no.3
    • /
    • pp.71-86
    • /
    • 1983
  • Current R.C. retaining wall design is bared on WSD, but the reliability based design method is more rational than the WSD. For this reason, this study proposes a reliability based design criteria for the cantilever retaining wall, which is most common type of retaining wall, and also proposes the theoretical bases of nominal safety factors of stability analysis by introducing the reliability theory. The limit state equations of stability analysis and design of each part of cantilever retaining wall are derived and the uncertainty measuring algorithms of each equation are also derived by MFOSM using Coulomb's coefficient of the active earth pressure and Hansen's bearing capacity formula. The levels of uncertainties corresponding to these algorithms are proposed appropriate values considering our actuality. The target reliability indices (overturning: ${\beta}_0$=4.0, sliding: ${\beta}_0$=3.5, bearing capacity: [${\beta}_0$=3.0, design for flexure: [${\beta}_0$=3.0, design for shear: ${\beta}_0$=3.2) are selected as optimal values considering our practice based on the calibration with the current R.C. retaining wall design safety provisions. Load and resistance factors are measured by using the proposed uncertainties and the selected target reliability indices. Furthermore, a set of nominal safety factors, allowable stresses, and allowable shear stresses are proposed for the current WSD design provisions. It may be asserted that the proposed LRFD reliability based design criteria for the R.C. retaining wall may have to be incorporated into the current R.C. design codes as a design provision corresponding to the USD provisions of the current R.C. design code.

  • PDF

Evaluation of SWAT Applicability to Simulation of Sediment Behaviois at the Imha-Dam Watershed (임하댐 유역의 유사 거동 모의를 위한 SWAT 모델의 적용성 평가)

  • Park, Younshik;Kim, Jonggun;Park, Joonho;Jeon, Ji-Hong;Choi, Dong Hyuk;Kim, Taedong;Choi, Joongdae;Ahn, Jaehun;Kim, Ki-sung;Lim, Kyoung Jae
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.4
    • /
    • pp.467-473
    • /
    • 2007
  • Although the dominant land use at the Imha-dam watershed is forest areas, soil erosion has been increasing because of intensive agricultural activities performed at the fields located along the stream for easy-access to water supply and relatively favorable topography. In addition, steep topography at the Imha-dam watershed is also contributing increased soil erosion and sediment loads. At the Imha-dam watershed, outflow has increased sharply by the typhoons Rusa and Maemi in 2002, 2003 respectively. In this study, the Soil and Water Assessment Tool (SWAT) model was evaluated for simulation of flow and sediment behaviors with long-term temporal and spatial conditions. The precipitation data from eight precipitation observatories, located at Ilwol, Subi and etc., were used. There was no significant difference in monthly rainfall for 8 locations. However, there was slight differences in rainfall amounts and patterns in 2003 and 2004. The topographical map at 1:5000 scale from the National Geographic Information Institute was used to define watershed boundaries, the detailed soil map at 1:25,000 scale from the National Institute of Highland Agriculture and the land cover data from the Korea Institute of Water and Environment were used to simulate the hydrologic response and soil erosion and sediment behaviors. To evaluate hydrologic component of the SWAT model, calibration was performed for the period from Jan. 2002 to Dec. 2003, and validation for Jan. 2004 to Apr. 2005. The $R^2$ value and El value were 0.93 and 0.90 respectively for calibration period, and the $R^2$ value and El value for validation were 0.73 and 0.68 respectively. The $R^2$ value and El value of sediment yield data with the calibrated parameters was 0.89 and 0.84 respectively. The comparisons with the measured data showed that the SWAT model is applicable to simulate hydrology and sediment behaviors at Imha dam watershed. With proper representation of the Best Management Practices (BM Ps) in the SWAT model, the SWAT can be used for pre-evaluation of the cost-effective and sustainable soil erosion BMPs to solve sediment issues at the Imha-dam watershed. In Korea, the Universal Soil Loss Equation (USLE) has been used to estimate the soil loss for over 30 years. However, there are limitations in the field scale mdel, USLE when applied for watershed. Also, the soil loss changes temporarily and spatially, for example, the Imha-dam watershed. Thus, the SW AT model, capable of simulating hydrologic and soil erosion/sediment behaviors temporarily and spatially at watershed scale, should be used to solve the muddy water issues at the Imha-dam watershed to establish more effective muddy water reduction countermeasure.

A Design for Realtime Monitoring System and Data Analysis Verification TA to Improve the Manufacturing Process Using HW-SW Integrated Framework (HW-SW 통합 프레임워크를 활용한 제조공정 개선을 위한 실시간 모니터링 시스템과 데이터 분석검증 TA설계)

  • Kim, Jae Chun;Jin, Seon A;Park, Young Hee;Noh, Seong Yeo;Lee, Hyun Dong
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.4 no.9
    • /
    • pp.357-370
    • /
    • 2015
  • Massive data occurred in a manufacturing place is able to fulfill very important roll to improve the manufacturing process. Domestic manufacturing business has been making an multilateral effort to react the change of manufacturing circumstance, but it undergoes many difficulties due to technical weakness. Coatings is a type of paint. It protect products by forming a film layer on the products and assigns various properties to those. The research of coatings is one of the fields studied actively in the polymer industry. The importance of the coatings in various industries is more increased. However, the industry still performs a mixing process in dependence on operator's experiences. In this paper, we propose a design for realtime monitoring system and data analysis verification TA to improve the manufacturing process using HW-SW integrated framework. Analysis results from the proposed framework are able to improve the coatings formulation process by collecting more quantitative reference data for work and providing it to work place. In particular, the framework may reduce the deterioration and loss cost which are caused by absence of a standard data as a accurate formulation criteria. It also may suggest a counterplan regarding errors which can be occurred in the future by deriving a standard calibration equation from the analysis using R and Design of Experiments about an error data generated in the mixing step.

Near infrared spectroscopy for classification of apples using K-mean neural network algorism

  • Muramatsu, Masahiro;Takefuji, Yoshiyasu;Kawano, Sumio
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1131-1131
    • /
    • 2001
  • To develop a nondestructive quality evaluation technique of fruits, a K-mean algorism is applied to near infrared (NIR) spectroscopy of apples. The K-mean algorism is one of neural network partition methods and the goal is to partition the set of objects O into K disjoint clusters, where K is assumed to be known a priori. The algorism introduced by Macqueen draws an initial partition of the objects at random. It then computes the cluster centroids, assigns objects to the closest of them and iterates until a local minimum is obtained. The advantage of using neural network is that the spectra at the wavelengths having absorptions against chemical bonds including C-H and O-H types can be selected directly as input data. In conventional multiple regression approaches, the first wavelength is selected manually around the absorbance wavelengths as showing a high correlation coefficient between the NIR $2^{nd}$ derivative spectrum and Brix value with a single regression. After that, the second and following wavelengths are selected statistically as the calibration equation shows a high correlation. Therefore, the second and following wavelengths are selected not in a NIR spectroscopic way but in a statistical way. In this research, the spectra at the six wavelengths including 900, 904, 914, 990, 1000 and 1016nm are selected as input data for K-mean analysis. 904nm is selected because the wavelength shows the highest correlation coefficients and is regarded as the absorbance wavelength. The others are selected because they show relatively high correlation coefficients and are revealed as the absorbance wavelengths against the chemical structures by B. G. Osborne. The experiment was performed with two phases. In first phase, a reflectance was acquired using fiber optics. The reflectance was calculated by comparing near infrared energy reflected from a Teflon sphere as a standard reference, and the $2^{nd}$ derivative spectra were used for K-mean analysis. Samples are intact 67 apples which are called Fuji and cultivated in Aomori prefecture in Japan. In second phase, the Brix values were measured with a commercially available refractometer in order to estimate the result of K-mean approach. The result shows a partition of the spectral data sets of 67 samples into eight clusters, and the apples are classified into samples having high Brix value and low Brix value. Consequently, the K-mean analysis realized the classification of apples on the basis of the Brix values.

  • PDF

Quantitative Analysis of Contents of Vegetable Oils in Sesame Oils by NIRS (근적외선분광광도법을 이용한 참기름중 이종식용유지 정량법에 관한 연구)

  • Kim, Jae-Kwan;Kim, Jong-Chan;Ko, Hoan-Uck;Lee, Jung-Bock;Kim, Young-Sug;Park, Yong-Bae;Lee, Myung-Jin;Kim, Myung-Gil;Kim, Kyung-A;Park, Eun-Mi
    • Journal of Food Hygiene and Safety
    • /
    • v.22 no.4
    • /
    • pp.257-267
    • /
    • 2007
  • The possibility of rapid non-destructive qualitative and quantitative analysis of vegetable oils such as perilla, com, soybean and rapaseed oils in sesame oils was evaluated. A calibration equation calculated by MPLS(Modified Partial Least Squares) regression technique was developed and coefficients of determination for perilla oil, com oil, soybean oil and rapaseed oil contents were 0.9992, 0.9694, 0.9795 and 0.9790 respectively. According to the data obtained from validation study, $R^2$ of contents of perilla, com, soybean, rapaseed oils were 0.997, 0.848, 0.957 and 0.968, and SEP of content of them 0.747, 5.069, 3.063 and 3.000 by MPLS respectively. The results indicate that the NIRS procedure can potentially be used as a non-destructive analysis method for the rapid and simple measurement of sesame oil mixed with other vegetable oils. The detection limits of the NIRS for perilla oil, com oil, soybean oil and rapaseed oil were presumed as 2%, $15{\sim}20%,\;15{\sim}20%$ and 10%, respectively.

A Study on the Integrated System Implementation of Close Range Digital Photogrammetry Procedures (근거리 수치사진측량 과정의 단일 통합환경 구축에 관한 연구)

  • Yeu, Bock-Mo;Lee, Suk-Kun;Choi, Song-Wook;Kim, Eui-Myoung
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.7 no.1 s.13
    • /
    • pp.53-63
    • /
    • 1999
  • For the close range digital photogrammetry, multi-step procedures should be embodied in an integrated system. However, it is hard to construct an Integrated system through conventional procedural processing. Using Object Oriented Programming(OOP), photogrammetric processings can be classified with corresponding subjects and it is easy to construct an integrated system lot digital photogrammetry as well as to add the newly developed classes. In this study, the equation of 3-dimensional mathematic model is developed to make an immediate calibration of the CCD camera, the focus distance of which varies according to the distance of the object. Classes for the input and output of images are also generated to carry out the close range digital photogrammetric procedures by OOP. Image matching, coordinate transformation, dirct linear transformation and bundle adjustment are performed by producing classes corresponding to each part of data processing. The bundle adjustment, which adds the principle coordinate and focal length term to the non-photogrammetric CCD camera, is found to increase usability of the CCD camera and the accuracy of object positioning. In conclusion, classes and their hierarchies in the digital photogrammetry are designed to manage multi-step procedures using OOP and close range digital photogrammetric process is implemented using CCD camera in an integrated System.

  • PDF

Detection and Absorbed-Dose Estimation of Irradiated Enzyme Powder Using ESR Spectroscopy (ESR Spectroscopy를 이용한 방사선 조사 효소분말의 검지와 흡수선량 예측)

  • Chung, Hyung-Wook;Jeong, Jae-Young;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.5
    • /
    • pp.1159-1163
    • /
    • 1999
  • Along with the increasing demands for food irradiation technology in the food industry, a proper detection means for controlling irradiated foods is required. Enzyme powder, which is permitted to be irradiated in Korea, was subjected to a detection trial by ESR spectroscopy. The high correlation coefficients were observed between the absorbed doses ranging from 2.5 to 15.0 kGy and the corresponding ESR signal intensity, such as $R^2$ = 0.9904 in gamma irradiation and $R^2$ = 0.9696 in electron beam. Pre-established threshold values for both non-irradiated control (1.19) and 2.5 kGy-irradiated samples (6.97 in gamma-ray; 7.36 in electron-beam) were successfully applicable to the detection of 30 coded unknown samples of enzyme powder. The calibration curves obtained from the samples irradiated at 2.5 to 15 kGy were expected to be potentially adopted to estimate absorbed doses ranging front 4 to 7 kGy with a quadratic equation.

  • PDF

Development of a force measurement device for curling sweeping with load cells (로드셀을 이용한 컬링 스위핑 힘 측정 장치 개발)

  • Lee, Sangcheol;Kim, Taewhan;Kil, Sekee;Choi, Sanghyup
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.11
    • /
    • pp.49-56
    • /
    • 2017
  • Curling sweeping is one of important motion to control the position of the curling stone, and sweeping speed and applied force to the broom pad are major research subjects. In this study, a device was developed to measure the force applied to the curling broom pad in curling sweeping motion, and two load cells were mounted between the broom pad and pad holder. Analog signals generated from the load cells were sampled about 300 times per second using a micro controller, and then converted to 10-bit digital signals. Calibration of the load cell and set up of regression equations to convert the measured electrical signals into mass (force) was done by three M1 class weights, and the developed system was designed as wearable device to minimize increasing of total weight of the broom. Same force was applied to the developed system and a force plate that was using as a reference force measurement system in field of sports, and the difference between the measured values were showed about $0.909{\pm}1.375N$(mean and standard deviation). The developed system could be applied other kinds of study which required force measurement function similar to sweeping motion.

Measurement and Estimation for the Clearance of Radioactive Waste Contaminated with Radioisotopes for Medical Application (의료용 방사성폐기물 자체처분을 위한 방사능 측정 및 평가)

  • Kim, Changbum;Park, MinSeok;Kim, Gi-Sub;Jung, Haijo;Jang, Seongjoo
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.8-14
    • /
    • 2014
  • The amounts of radioactive wastes to be disposed in the medical institute have been increased due to development of radiation diagnosis and therapy rapidly. They are produced mostly by the very short lived radioisotopes such as $^{18}F$ used in PET/CT, $^{99m}Tc$, $^{123}I$, $^{125}I$ and $^{201}Tl$, etc. IAEA proposed a criteria for the clearance level of waste which depends on the individual ($10{\mu}Sv/y$) and collective dose (1 man-Sv/y), and concentration of each nuclide (IAEA Safety Series No 111-P-1.1, 1992 and IAEA RS-G-1.7, 2004). Radioactive wastes of $^{18}F$, $^{99m}Tc$, $^{123}I$, $^{125}I$ and $^{201}TI$ in the several types of container like Marinelli beaker, vial and plastic, were collected to measure the concentration of the waste of each nuclide in accordance with IAEA criteria. The measurement method and procedure of determining specific activity of the wastes using gamma emitters like MCA, gamma counter and beta emitters were developed. For the efficiency calibration of the detectors, CRM (certified reference material) which has the same dimension and shape was provided by Korea Research Institute of Standards and Science (KRISS). Correction factor of the radioactivity decay was calculated based on the measurement results, and the consideration of mutual relation with theoretical equation. The result of this study will be proposed as ISO standard.

Development of Rapid Prediction Model of C3G Content in Black Pigmented Rice (흑자색미의 C3G 색소함량 신속 예측모델 개발)

  • Ryu Su-Noh;Yang Jong-Jin;Park Sun-Zik
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.50 no.spc1
    • /
    • pp.1-3
    • /
    • 2005
  • It has been reported that Cyanidin 3-Glu-coside (C3G) of the black pigmented rice was as the high anti-oxidency and analyzed by high performance liquid chromatography (HPLC). However, the analysis of C3G by HPLC is needed long pre-treated steps, so development of methods with simple pre-treated steps is needed in order to breed vices with high C3G contents. The analysis of components using near infrared reflectance (NIR) was well known as non pre-treated and nondestructive. C3G contents of Bengjinjubyeo$\times$Suwon425 $F_{10}$ 385 lines were used in order to develop C3G content prediction model in pigmented rice using FT-NIR. The results of C3G content of FT-NIR compared with HPLC were showed that the equation was f(x)=0.9427x+34.0430, $R^2$, standard error of calibration was 0.943, 0.116 and those of validation was 0.928, 0.122, respectively. This prediction model will be able to be used for analyzing C3G contents in black pigmented rice.