• Title/Summary/Keyword: calibration coefficients

Search Result 328, Processing Time 0.026 seconds

Variation on Estimated Values of Radioactivity Concentration According to the Change of the Acquisition Time of SPECT/CT (SPECT/CT의 획득시간 증감에 따른 방사능농도 추정치의 변화)

  • Kim, Ji-Hyeon;Lee, Jooyoung;Son, Hyeon-Soo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.15-24
    • /
    • 2021
  • Purpose SPECT/CT was noted for its excellent correction method and qualitative functions based on fusion images in the early stages of dissemination, and interest in and utilization of quantitative functions has been increasing with the recent introduction of companion diagnostic therapy(Theranostics). Unlike PET/CT, various conditions like the type of collimator and detector rotation are a challenging factor for image acquisition and reconstruction methods at absolute quantification of SPECT/CT. Therefore, in this study, We want to find out the effect on the radioactivity concentration estimate by the increase or decrease of the total acquisition time according to the number of projections and the acquisition time per projection among SPECT/CT imaging conditions. Materials and Methods After filling the 9,293 ml cylindrical phantom with sterile water and diluting 99mTc 91.76 MBq, the standard image was taken with a total acquisition time of 600 sec (10 sec/frame × 120 frames, matrix size 128 × 128) and also volume sensitivity and the calibration factor was verified. Based on the standard image, the comparative images were obtained by increasing or decreasing the total acquisition time. namely 60 (-90%), 150 (-75%), 300 (-50%), 450 (-25%), 900 (+50%), and 1200 (+100%) sec. For each image detail, the acquisition time(sec/frame) per projection was set to 1.0, 2.5, 5.0, 7.5, 15.0 and 20.0 sec (fixed number of projections: 120 frame) and the number of projection images was set to 12, 30, 60, 90, 180 and 240 frames(fixed time per projection:10 sec). Based on the coefficients measured through the volume of interest in each acquired image, the percentage of variation about the contrast to noise ratio (CNR) was determined as a qualitative assessment, and the quantitative assessment was conducted through the percentage of variation of the radioactivity concentration estimate. At this time, the relationship between the radioactivity concentration estimate (cps/ml) and the actual radioactivity concentration (Bq/ml) was compared and analyzed using the recovery coefficient (RC_Recovery Coefficients) as an indicator. Results The results [CNR, radioactivity Concentration, RC] by the change in the number of projections for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.5%, +3.90%, 1.04] at -90%, [-77.9%, +2.71%, 1.03] at -75%, [-55.6%, +1.85%, 1.02] at -50%, [-33.6%, +1.37%, 1.01] at -25%, [-33.7%, +0.71%, 1.01] at +50%, [+93.2%, +0.32%, 1.00] at +100%. and also The results [CNR, radioactivity Concentration, RC] by the acquisition time change for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.3%, -3.55%, 0.96] at - 90%, [-73.4%, -0.17%, 1.00] at -75%, [-49.6%, -0.34%, 1.00] at -50%, [-24.9%, 0.03%, 1.00] at -25%, [+49.3%, -0.04%, 1.00] at +50%, [+99.0%, +0.11%, 1.00] at +100%. Conclusion In SPECT/CT, the total coefficient obtained according to the increase or decrease of the total acquisition time and the resulting image quality (CNR) showed a pattern that changed proportionally. On the other hand, quantitative evaluations through absolute quantification showed a change of less than 5% (-3.55 to +3.90%) under all experimental conditions, maintaining quantitative accuracy (RC 0.96 to 1.04). Considering the reduction of the total acquisition time rather than the increasing of the image acquiring time, The reduction in total acquisition time is applicable to quantitative analysis without significant loss and is judged to be clinically effective. This study shows that when increasing or decreasing of total acquisition time, changes in acquisition time per projection have fewer fluctuations that occur in qualitative and quantitative condition changes than the change in the number of projections under the same scanning time conditions.

Modeling of Estimating Soil Moisture, Evapotranspiration and Yield of Chinese Cabbages from Meteorological Data at Different Growth Stages (기상자료(氣象資料)에 의(依)한 배추 생육시기별(生育時期別) 토양수분(土壤水分), 증발산량(蒸發散量) 및 수량(收量)의 추정모형(推定模型))

  • Im, Jeong-Nam;Yoo, Soon-Ho
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.21 no.4
    • /
    • pp.386-408
    • /
    • 1988
  • A study was conducted to develop a model for estimating evapotranspiration and yield of Chinese cabbages from meteorological factors from 1981 to 1986 in Suweon, Korea. Lysimeters with water table maintained at 50cm depth were used to measure the potential evapotranspiration and the maximum evapotranspiration in situ. The actual evapotranspiration and the yield were measured in the field plots irrigated with different soil moisture regimes of -0.2, -0.5, and -1.0 bars, respectively. The soil water content throughout the profile was monitored by a neutron moisture depth gauge and the soil water potentials were measured using gypsum block and tensiometer. The fresh weight of Chinese cabbages at harvest was measured as yield. The data collected in situ were analyzed to obtain parameters related to modeling. The results were summarized as followings: 1. The 5-year mean of potential evapotranspiration (PET) gradually increased from 2.38 mm/day in early April to 3.98 mm/day in mid-June, and thereafter, decreased to 1.06 mm/day in mid-November. The estimated PET by Penman, Radiation or Blanney-Criddle methods were overestimated in comparison with the measured PET, while those by Pan-evaporation method were underestimated. The correlation between the estimated and the measured PET, however, showed high significance except for July and August by Blanney-Criddle method, which implied that the coefficients should be adjusted to the Korean conditions. 2. The meteorological factors which showed hgih correlation with the measured PET were temperature, vapour pressure deficit, sunshine hours, solar radiation and pan-evaporation. Several multiple regression equations using meteorological factors were formulated to estimate PET. The equation with pan-evaporation (Eo) was the simplest but highly accurate. PET = 0.712 + 0.705Eo 3. The crop coefficient of Chinese cabbages (Kc), the ratio of the maximum evapotranspiration (ETm) to PET, ranged from 0.5 to 0.7 at early growth stage and from 0.9 to 1.2 at mid and late growth stages. The regression equation with respect to the growth progress degree (G), ranging from 0.0 at transplanting day to 1.0 at the harvesting day, were: $$Kc=0.598+0.959G-0.501G^2$$ for spring cabbages $$Kc=0.402+1.887G-1.432G^2$$ for autumn cabbages 4. The soil factor (Kf), the ratio of the actual evapotranspiration to the maximum evapotranspiration, showed 1.0 when the available soil water fraction (f) was higher than a threshold value (fp) and decreased linearly with decreasing f below fp. The relationships were: Kf=1.0 for $$f{\geq}fp$$ Kf=a+bf for f$$I{\leq}Esm$$ Es = Esm for I > Esm 6. The model for estimating actual evapotranspiration (ETa) was based on the water balance neglecting capillary rise as: ETa=PET. Kc. Kf+Es 7. The model for estimating relative yield (Y/Ym) was selected among the regression equations with the measured ETa as: Y/Ym=a+bln(ETa) The coefficients and b were 0.07 and 0.73 for spring Chinese cabbages and 0.37 and 0.66 for autumn Chinese cabbages, respectively. 8. The estimated ETa and Y/Ym were compared with the measured values to verify the model established above. The estimated ETa showed disparities within 0.29mm/day for spring Chinese cabbages and 0.19mm/day for autumn Chinese cabbages. The average deviation of the estimated relative yield were 0.14 and 0.09, respectively. 9. The deviations between the estimated values by the model and the actual values obtained from three cropping field experiments after the completion of the model calibration were within reasonable confidence range. Therefore, this model was validated to be used in practical purpose.

  • PDF

Analysis of Systemic Pesticide Imidacloprid and Its Metabolites in Pepper using QuEChERS and LC-MS/MS (QuEChERS 전처리와 LC-MS/MS를 이용한 고추 중 침투성농약 Imidacloprid 및 대사물질 동시분석법)

  • Seo, Eun-Kyung;Kim, Taek-Kyum;Hong, Su-Myeong;Kwon, Hye-Yong;Kwon, Ji-Hyung;Son, Kyung-Ae;Kim, Jang-Eok;Kim, Doo-Ho
    • The Korean Journal of Pesticide Science
    • /
    • v.17 no.4
    • /
    • pp.264-270
    • /
    • 2013
  • Imidacloprid is a systemic insecticide which act as an insect neurotoxin. It used for control of pest such as aphids and other sucking insects in fruits and vegetables. Systemic pesticides move inside a crop following absorption by the plant, and these were converted into a variety of metabolites. Sometimes these metabolites make a problem about safety of agricultural products. So a simultaneous determination method of pesticide and its metabolites is needed, to monitor their presence in agricultural product and study on the fate of pesticide in a plant. This study's aim is to investigate simultaneous analysis method of imidacloprid and its metabolites, imidacloprid guanidine, imidacloprid olefin, imidacloprid urea, and 6-chloronicotinic acid in red pepper using QuEChERS method and LC-MS/MS systems. QuEChERS method was modifed beacuase $MgSO_4$ salts decreased the recoveries of 6-chloronicotinic acid in extraction procedure. Imidacloprid and its metabolites were extracted by acetonitrile with 1% glacial acetic acid and the extracts were purified through QuEChERS with primary secondary amine (PSA) and $C_{18}$ and analyzed with LC-MS/MS in ESI positive mode. Standard calibration curves were made by matrix matched standards and their correlation coefficients were higher than 0.999. Recovery studies were carried out on spiked pepper blank sample at four concentration levels (0.01, 0.04 and 0.1, 0.4 mg/kg). The average recoveries of imidacloprid and its metabolites were in the range of 70~120% with < 20% RSD. This result indicated that the method using QuEChERS and LC-MS/MS was suitable for the simultaneous determination of imidacloprid and its metabolites in red pepper.

Optimization of Analytical Methods for Ochratoxin A and Zearalenone by UHPLC in Rice Straw Silage and Winter Forage Crops (UHPLC를 이용한 볏짚 사일리지와 동계사료작물의 오크라톡신과 제랄레논 분석법 최적화)

  • Ham, Hyeonheui;Mun, Hye Yeon;Lee, Kyung Ah;Lee, Soohyung;Hong, Sung Kee;Lee, Theresa;Ryu, Jae-Gee
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.36 no.4
    • /
    • pp.333-339
    • /
    • 2016
  • The objective of this study was to optimize analytical methods for ochratoxin A (OTA) and zearalenone (ZEA) in rice straw silage and winter forage crops using ultra-high performance liquid chromatography (UHPLC). Samples free of mycotoxins were spiked with $50{\mu}g/kg$, $250{\mu}g/kg$, or $500{\mu}g/kg$ of OTA and $300{\mu}g/kg$, $1500{\mu}g/kg$, or $3000{\mu}g/kg$ of ZEA. OTA and ZEA were extracted by acetonitrile and cleaned-up using an immunoaffinity column. They were then subjected to analysis with UHPLC equipped with a fluorescence detector. The correlation coefficients of calibration curves showed high linearity ($R^2{\geq_-}0.9999$ for OTA and $R^2{\geq_-}0.9995$ for ZEA). The limit of detection and quantification were $0.1{\mu}g/kg$ and $0.3{\mu}g/kg$, respectively, for OTA and $5{\mu}g/kg$ and $16.7{\mu}g/kg$, respectively, for ZEA. The recovery and relative standard deviation (RSD) of OTA were as follows: rice straw = 84.23~95.33%, 2.59~4.77%; Italian ryegrass = 79.02~95%, 0.86~5.83%; barley = 74.93~97%, 0.85~9.19%; rye = 77.99~96.67%, 0.33~6.26%. The recovery and RSD of ZEA were: rice straw = 109.6~114.22%, 0.67~7.15%; Italian ryegrass = 98.01~109.44%, 1.65~4.81%; barley = 98~113.53%, 0.25~5.85%; rye = 90.44~108.56%, 2.5~4.66%. They both satisfied the standards of European Commission criteria (EC 401-2006) for quantitative analysis. These results showed that the optimized methods could be used for mycotoxin analysis of forages.

Development and Validation of Analytical Method for Wogonin, Quercetin, and Quercetin-3-O-glucuronide in Extracts of Nelumbo nucifera, Morus alba L., and Raphanus sativus Mixture (연잎, 상엽, 건조 무 혼합 추출물의 지표성분 wogonin, quercetin 및 quercetin-3-O-glucuronide의 분석법 개발 및 검증)

  • Jang, Gill-Woong;Park, Eun-Young;Choi, Seung-Hyun;Choi, Sun-il;Cho, Bong-Yeon;Sim, Wan-Sup;Han, Xinggao;Cho, Hyun-Duk;Lee, Ok-Hwan
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.4
    • /
    • pp.289-295
    • /
    • 2018
  • The aim of this study was to develop and validate an analytical method for determining the presence of wogonin, quercetin, and quercetin-3-O-glucuronide in extracts of Nelumbo nucifera, Morus alba L., and Raphanus sativus mixtures. We evaluated the specificity, linearity, precision, accuracy, limit of detection (LOD), and limit of quantification (LOQ) of analytical methods for wogonin, quercetin, and quercetin-3-O-glucuronide using high performance liquid chromatography. Our result showed that the correlation coefficients of the calibration curve for wogonin, quercetin, and quercetin-3-O-glucuronide were 0.9999. The LOD for wogonin, quercetin, and quercetin-3-O-glucuronide ranged from 0.09 to 0.16 and those for the LOQ ranged from 0.26 to $0.48{\mu}g/mL$. The inter-day and intra-day precision values of wogonin, quercetin, and quercetin-3-O-glucuronide ranged from 0.74 to 1.87 and from 0.28 to 1.12%, respectively. The inter-day and intra-day accuracies were 99.96~115.88% and 99.73~114.81%, respectively. Therefore, the analytical method was validated for the detection of wogonin, quercetin, and quercetin-3-O-glucuronide in extracts of Nelumbo nucifera, Morus alba L., and Raphanus sativus mixtures.

Establishment of analytical methods for HPHC list of mainstream cigarette smoke (담배 주류연 중 7개 그룹의 유해성분(HPHC) 분석법 확립 및 유효성 평가)

  • Park, Hyoung-Joon;Lee, Jin-Hee;Cho, So-Hyun;Heo, Seok;Yoon, Chang-yong;Baek, Sun-Young
    • Analytical Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.385-397
    • /
    • 2015
  • Harmful and potentially harmful constituents (HPHCs) are chemical compounds in tobacco smoke that cause harm to smokers and non-smokers. This study established and validated methods for the analysis of HPHCs from mainstream cigarette smoke. The analyzed HPHCs were categorized into seven groups: aromatic amines, volatile organic compounds (VOCs), heavy metals, tobacco specific nitrosamines (TSNAs), benzo[a]pyrene (B[a]P), ammonia, and carbonyl compounds. The methods were validated by specificity, linearity, limit of detection (LOD), accuracy, precision, and recovery. These validated methods were then applied to the reference cigarettes (1R5F, 3R4F). The correlation coefficients (r2) for the calibration curves of the seven groups were over 0.995. The LODs showed values of 0.01-0.04 ng/cig cig for aromatic amines, 0.01-0.16 μg/cig for VOCs, 0.01-1.27 ng/cig for heavy metals, 0.06-0.28 ng/cig for TSNAs, 0.04 ng/cig for benzo[a]pyrene, 0.08 μg/cig for ammonia, and 0.78-1.77 μg/cig for carbonyl compounds. The precisions obtained from the intra and inter-day batches were less than 15%. The accuracy and the recovery range were less than 15% and 79.2-117.5%, respectively. The proposed methods can therefore be applied for determining HPHCs in tobacco mainstream smoke.

Evaluation of Radiation Dose for Dual Energy CBCT Using Multi-Grid Device (에너지 변조 필터를 이용한 이중 에너지 콘빔 CT의 선량 평가)

  • Ju, Eun Bin;Ahn, So Hyun;Cho, Sam Ju;Keum, Ki Chang;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.31-36
    • /
    • 2016
  • The paper discusses radiation dose of dual energy CT on which copper modulation layer, is mounted in order to improve diagnostic performance of the dual energy CT. The radiation dose is estimated using MCNPX and its results are compared with that of the conventional dual energy CT system. CT X-ray spectra of 80 and 120 kVp, which are usually used for thorax, abdominal, head, and neck CT scans, were generated by the SPEC78 code and were used for the source specification 'SDEF' card for MCNPX dose modeling. The copper modulation layer was located 20 cm away from a source covering half of the X-ray window. The radiation dose was measured as changing its thickness from 0.5 to 2.0 mm at intervals of 0.5 mm. Since the MCNPX tally provides only normalized values to a single particle, the dose conversion coefficients of F6 tally for the modulation layer-based dual energy CBCT should be calculated for matching the modeling results into the actual dose. The dose conversion coefficient is $7.2*10^4cGy/output$ that is obtained from dose calibration curve between F6 tally and experimental results in which GAFCHORMIC EBT3 films were exposed by an already known source. Consequently, the dose of the modulation layer-based dual energy cone beam CT is 33~40% less than that of the single energy CT system. On the basis of the results, it is considered that scattered dose produced by the copper modulation layer is very small. It shows that the modulation layer-based dual energy CBCT system can effectively reduce radiation dose, which is the major disadvantage of established dual energy CT.

Modification and Validation of Analytical Method for Oxypaeoniflorin and Paeoniflorin in Moutan Cortex Radicis Extract (목단피 추출물의 Oxypaeoniflorin 및 Paeoniflorin의 분석법 개선 및 검증)

  • Choi, Seung-Hyun;Yoo, Chang-Kil;Hwang, Ji-Hyun;Lee, Gi-Bbeum;Lee, Young-Jin;Lee, Boo-Yong;Lee, Ok-Hwan
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.9
    • /
    • pp.1091-1096
    • /
    • 2017
  • The aim of this study was the validation of a modified analytical method for determination of oxypaeoniflorin and paeoniflorin in Moutan Cortex Radicis extract. For validation of the analytical method, we modified established analytical methods and validated improvement. For validation, the specificity, linearity, precision, accuracy, limit of detection (LOD), and limit of quantification of oxypaeoniflorin and paeoniflorin were measured by high performance liquid chromatography. The results show that the correlation coefficients of the calibration curve for oxypaeoniflorin and paeoniflorin were 1.0000 and 0.9998, respectively. The LOD for oxypaeoniflorin and paeoniflorin were $0.23{\mu}g/mL$ and $0.25{\mu}g/mL$, respectively. The inter-day and intra-day precision values of oxypaeoniflorin and paeoniflorin were 0.70~3.19% and 1.74~2.43%, and 0.32~0.92% and 0.62~2.28%, respectively. The inter-day and intra-day accuracies of oxypaeoniflorin and paeoniflorin were 98.33~102.11% and 97.72~118.12%, and 98.44~101.56% and 97.10~112.00%, respectively. Therefore, the analytical method was validated for the detection of oxypaeoniflorin and paeoniflorin in Moutan Cortex Radicis.

Evaluation of Feed Values for Imported Hay Using Near Infrared Reflectance Spectroscopy (근적외선분광법을 이용한 수입 건초의 사료가치 평가)

  • Park, Hyung Soo;Kim, Ji Hye;Choi, Ki Choon;Oh, Mirae;Lee, Ki-Won;Lee, Bae Hun
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.39 no.4
    • /
    • pp.258-263
    • /
    • 2019
  • Near infrared reflectance spectroscopy (NIRS) has become increasingly used as a rapid and accurate method of evaluating some chemical compositions in forages. The objective of this study was to evaluate the potential of NIRS, applied to imported forage, to estimate the moisture and chemical parameters for imported hays. A population of 392 imported hay representing a wide range in chemical parameters was used in this study. Samples of forage were scanned at 1 nm intervals over the wavelength range 680-2500nm and the optical data was recorded as log 1/Reflectance(log 1/R), which scanned in intact fresh condition. The spectral data were regressed against a range of chemical parameters using partial least squares(PLS) multivariate analysis in conjunction with spectral math treatments to reduced the effect of extraneous noise. The optimum calibrations were selected based on the highest coefficients of determination in cross validation(R2) and the lowest standard error of cross-validation(SECV). The results of this study showed that NIRS predicted the chemical parameters with very high degree of accuracy. The R2 and SECV for imported hay calibration were 0.92(SECV 0.61%) for moisture, 0.98(SECV 0.65%) for acid detergent fiber, 0.97(SECV 0.40%) for neutral detergent fiber, 0.99(SECV 0.06%) for crude protein and 0.97(SECV 3.04%) for relative feed value on a dry matter(%), respectively. Results of this experiment showed the possibility of NIRS method to predict the moisture and chemical composition of imported hay in Korea for routine analysis method to evaluate the feed value.

Determination of Carazolol and Azaperone in Livestock and Fishery Products Using Liquid Chromatography-tandem Mass Spectrometry (축수산물에서 LC-MS/MS를 이용한 카라졸롤 및 아자페론 분석)

  • Choi, Soo Yeon;Kang, Hui-Seung;Kim, Joohye;Cheon, So-Young;Jeong, Jiyoon;Cho, Byung-Hoon;Lee, Kang-Bong
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.3
    • /
    • pp.176-184
    • /
    • 2018
  • The aim of the present work was to develop simultaneous methods of quantification of carazolol, azaperone, and azaperol residues in livestock and fishery products using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Samples were extracted from beef, pork, chicken, egg, milk and shrimp using acetonitrile (ACN); while flat fish and eel were extracted using 80% ACN. For purification, ACN saturated n-hexane was used to remove fat composition. The standard calibration curves showed good linearity as correlation coefficients; $r^2$ was > 0.99. Average recoveries expressed were within the range of 67.9-105% for samples fortified at three different levels ($0.5{\times}MRL$, $1{\times}MRL$ and $2{\times}MRL$). The correlation coefficient expressed as precision was within the range of 0.55-7.93%. The limit of quantification (LOQ) was 0.0002-0.002 mg/kg. The proposed analytical method showed high accuracy and acceptable sensitivity based on Codex guideline requirements (CAC/GL71-2009). This method can be used to analyze the residue of carazolol, azaperone, and azaperol in livestock and fishery products.