• 제목/요약/키워드: cable failure

검색결과 181건 처리시간 0.025초

Structural behavior of cable-stayed bridges after cable failure

  • Kim, Seungjun;Kang, Young Jong
    • Structural Engineering and Mechanics
    • /
    • 제59권6호
    • /
    • pp.1095-1120
    • /
    • 2016
  • This paper investigates the change of structural characteristics of steel cable-stayed bridges after cable failure. Cables, considered as the intermediate supports of cable-stayed bridges, can break or fail for several reasons, such as fire, direct vehicle clash accident, extreme weather conditions, and fatigue of cable or anchorage. Also, the replacement of cables can cause temporary disconnection. Because of the structural characteristics with various geometric nonlinearities of cable-stayed bridges, cable failure may cause significant change to the structural state and ultimate behavior. Until now, the characteristics of structural behavior after cable failure have rarely been studied. In this study, rational cable failure analysis is suggested to trace the new equilibrium with structural configuration after the cable failure. Also, the sequence of ultimate analysis for the structure that suffers cable failure is suggested, to study the change of ultimate behavior and load carrying capacity under specific live load conditions. Using these analysis methods, the statical behavior after individual cable failure is studied based on the change of structural configuration, and distribution of internal forces. Also, the change of the ultimate behavior and load carrying capacity under specific live load conditions is investigated, using the proposed analysis method. According to the study, significant change of the statical behavior and ultimate capacity occurs although just one cable fails.

A Multidiscipline 35 kV Cable Failure Investigation

  • Orton Harry;Furst Gabor;Batho Joe;Rao Avaral;Salvida Candelario de;Morante Moises Gomes
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권2호
    • /
    • pp.67-71
    • /
    • 2005
  • Cable failure investigations must evaluate all facets of cable technology to reach a complete understanding of why and how an underground power cable failed. This paper presents the salient points of a recent investigation into an in-service failure after only several weeks of operation.

케이블 단선 후 강사장교의 구조 및 극한 거동 변화 (Change of Statical Behavior and Ultimate Capacity of Steel Cable-stayed Bridges after Cable Failure)

  • 김승준;최준호;원덕희;한택희;강영종
    • 한국강구조학회 논문집
    • /
    • 제23권6호
    • /
    • pp.747-761
    • /
    • 2011
  • 본 논문에서는 강사장교의 케이블이 단선된 후 정역학적인 구조 거동 및 극한 거동 변화에 대해 기술한다. 사장교의 케이블은 화재, 차량의 충돌, 케이블 본선 및 정착구의 피로에 의해 단선이 가능하다. 이에 더하여 필요시 케이블의 교체 작업 시 일시적인 단선이 나타날 수 있다. 케이블이 구조물 본체에서 단락되면 결과적으로 케이블이 분담해야할 힘을 지지하지 못하여 이 힘은 다른 구조체로 전달되고 결과적으로 구조 상태의 변화가 발생한다. 그리고 케이블의 단선은 결국 구조물의 지지력의 손실을 의미하므로 케이블 단선 후 구조물의 내하력이 저하될 것이다. 본 연구에서는 엄밀한 비선형 유한요소해석 이론을 근간으로 하여 케이블 단선 후 구조물의 새로운 평형상태를 찾는 단선 해석기법을 제시한다. 그리고 케이블이 단선된 후 활하중에 대한 구조물의 극한거동을 해석할 수 있는 극한 해석 기법 역시 제시한다. 보다 합리적인 해석 연구를 위해 본 연구에서는 초기형상해석, 케이블 단선해석, 활하중에 대한 비선형해석을 순차적으로 수행하는 총 세단계의 해석 절차를 거친다. 본 해석기법을 이용하여 각 케이블의 단선이 사장교의 구조 상태 및 극한 거동의 변화에 미치는 영향을 분석하였다.

Dynamic response of cable-stayed bridges subjected to sudden failure of stays - the 2D problem

  • Raftoyiannis, I.G.;Konstantakopoulos, T.G.;Michaltsos, G.T.
    • Coupled systems mechanics
    • /
    • 제3권4호
    • /
    • pp.345-365
    • /
    • 2014
  • A significant problem met in engineering practice when designing cable-stayed bridges is the failure of cables. Many different factors can lead to sudden failure of cables, such as corrosion, continuous friction or abrasion, progressive and extended crevice created by fatigue and finally an explosion caused by sabotage or accident, are some of the causes that can lead to the sudden failure of one or more cables. This paper deals with the sudden failure of cables in a special form of cable-stayed bridges with a single line of cables anchored at the central axis of the deck's cross-section. The analysis is carried out by the modal superposition technique where an analytical method developed by the authors in a previous work has been employed.

지중 배전용케이블 고장통계 분석 및 고장률 활용 진단대상 우선순위 선정방법 (MV Cable Failure Statistics Analysis and Failure Rate Utilization Method of Prioritization of Diagnosis Targets)

  • 조종은;이온유;김상봉;김강식
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제7권2호
    • /
    • pp.263-268
    • /
    • 2021
  • This paper statistically analyzes the time required for each failure cause and describes a diagnostic method for 159 reports of failure analysis of MV cables that occurred in the distribution system of KEPCO over the past 18 years. In addition, the manufacturer's failure rate compared to 100C-km was calculated using 381 cases of MV cable deterioration failure between 2008 and 2020. It is hoped that this paper will help those in charge of maintaining underground facilities at the business office to use the failure rate to prioritize facility diagnosis.

원전 노출 화재시 케이블 기능상실 온도에 관한 연구 (A Study on Cable Functional Failure Temperature by Exposed Fire in Nuclear Power Plants)

  • 김두현;임혁순
    • 한국안전학회지
    • /
    • 제26권5호
    • /
    • pp.41-45
    • /
    • 2011
  • The fire event occurred in fire proof zone often causes serious electrical problems such as shorts, ground faults, or open circuits in nuclear power plants. These would be directed to the loss of safe shutdown capabilities performed by safety related systems and equipments The fire event can treat the basic design principle that safety systems should keep their functions with redundancy and independency. In case of a cable fire, operators can not perform their mission properly and can misjudge the situation because of spurious operation, wrong indication or instrument. These would deteriorate the plant capabilities of safety shutdown and make disastrous conditions. In this paper, the cables of the representative nuclear power plant in korea is selected and the cable functional failure temperature by exposed fire using Cable Response to Live Fire(CAROLFIRE) is studied. It is expected that the results are very useful to know the cable failure temperature by exposed fire. We confirmed the safety and integrity of the cable by exposed fire and those results will use the based data of cable exposed fire characteristics.

혼합 배전계통에서 피뢰기적용과 접지시스템 변경을 고려한 서지 해석에 관한 연구 (A Study on the Surge Analysis considering Surge Arrester and Grounding System in the Combined Distribution System)

  • 윤창섭;이종범;김병숙
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.204-205
    • /
    • 2006
  • This paper describes the protective ability of lightning arrestor in combined distribution system with power cable. To evaluate the protective ability, change of arrestor and grounding location are considered. On the other hand, arrestor developed by Cooper Power Systems for underground power cable system, is considered to evaluate surge protective ability as in underground system, when arrestor occurs failure has overhead line. The result shows that lightning arrestor in combined distribution system with power cable protect effectively when failure at arrestor in overhead line. On the other hand, arrestor developed by Cooper Power Systems for underground power cable system, is considered to evaluate surge protective ability in underground distribution system, when arrestor of overhead line has failure. The result shows that lightning arrestor installed in underground cable can effectively protected cables from surge when arrestor of overhead line has failure. And also even though grounding locations are decreased, it is revealed that protective ability is nearly similar.

  • PDF

전력케이블 시스템의 진단기술 지도 (Technical Map of Diagnosis for Power Cable Systems)

  • 김정태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.4-6
    • /
    • 2005
  • This paper deals with the technical map of diagnosis for power cable systems. For this purpose, failure status, failure and degradation causes, and newly suggested diagnostic techniques were investigated and analyzed. From the analysis, the technical map of diagnosis for power cable systems was proposed.

  • PDF

Effect of pre-stressed cable on pre-stressed mega-braced steel frame

  • Tang, Baijian;Zhang, Fuxing;Wang, Yi;Wang, Fei
    • Structural Engineering and Mechanics
    • /
    • 제59권2호
    • /
    • pp.327-341
    • /
    • 2016
  • This study addresses the effect of pre-stressed cables on a pre-stressed mega-braced steel frame through employing static analysis and pushover analysis. The performances of a pre-stressed mega-braced steel frame and a pure steel frame without mega-braces are compared in terms of base shear, ductility, and failure mode. The influence of the cable parameters is also analyzed. Numerical results show that cable braces can effectively improve the lateral stiffness of a pure frame. However, it reduces structural ductility and degenerates structural pre-failure lateral stiffness greatly. Furthermore, it is found that 20% fluctuation in the cable pretension has little effect on structural ultimate bearing capacity and lateral stiffness. As comparison, 20% fluctuation in the cable diameter has much greater impact.

154KV 가스중 종단접속의 사고유형과 방지대책 (FAILURE ANALYSIS OF 154KV TERMINATION IN GAS INSULATED SWITCHGEAR)

  • 이천구;이민규;김병수;허근도
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.594-597
    • /
    • 1993
  • With the increase of electric power demand in the downtown area. many problems, such as the difficulty in security of substation site and interference of the electromagnetic wave or damage to person due to outdoor type substation facilities has been occured. Therefore, the compaction of substation facilities is required and the gas insulated switchgear(GIS) has been adopted accordingly. However, much care should be taken of the interface problem between cable and GIS. This paper describes the failure analysis and a countmeasure for prevent ion from failure in the interface.

  • PDF