• 제목/요약/키워드: building of stairs

검색결과 78건 처리시간 0.021초

건축물 계단에서의 연돌효과 저감방안에 대한 3차원 수치해석 연구 (Study on 3D Numerical Analysis of Stack Effect Reduction in Stairwell of Building)

  • 김정엽;김지석
    • 설비공학논문집
    • /
    • 제27권3호
    • /
    • pp.152-157
    • /
    • 2015
  • Stack effect on high-rise building have negative effect on living environment, energy and life-safety aspect. Thus, it's necessary to find the measure to reduce the stack effect. As a result of field test on a 31-story building, a circulating type stack effect reduction technology was developed, which supplies air in the low stairs and discharges air in the high stairs. To evaluate the performance of this circulating type stack effect reduction technology on building stairs, a 3D numerical analysis was carried out by using Momentum Loss Model for analyzing leakage flow between compartments in a building. Consequently, numerical analysis proved that the stack effect on building stairs was reduced by a circulating type stack effect reduction technology.

업무공간계단의 공공적 특성에 관한 연구 (A Study on the Characteristics of Architectural Publicity for Stairs in the Office Buildings)

  • 이경은
    • 한국콘텐츠학회논문지
    • /
    • 제11권12호
    • /
    • pp.682-689
    • /
    • 2011
  • 본 연구의 목적은 업무공간 건축물에서 수직적 이동개념의 요소로서 계단이 공간에서 갖는 공공적 특성을 고찰하고 분석함으로써 공용공간으로서의 계단의 중요성을 부각하고 이의 활성화 방안을 모색하는데 있다. 선행 연구 및 문헌고찰, 사례조사 및 현장조사를 통해 건축적 공공성 분석을 통해 업무공간계단의 공공성 분석항목을 도출하고, 도출된 공공성요소를 토대로 사례별 업무공간 건축물 계단의 공공적 특성을 분석 하였다. 연구결과 2000년 이후에 건축된 사례연구 건축물들은 공공의 성격을 활성화하기 위하여 전반적으로 공공적 특성을 지닌 것으로 나타났다. 공간과 공간간의 매개적 요소, 인간행위의 촉매요소, 지각 인식요소로서의 역할을 하는 업무공간의 계단은 접근성, 개방성, 쾌적성의 공공적 특성요소를 강조하여 활성화되어지는 공공성이 더욱 중요시 인식되어야하며 향후 많은 연구가 필요하다고 판단된다.

고층빌딩에서 옥외피난계단의 효용성에 관한 연구 (A Study on the Efficiency of Evacuation Exterior Stairs in High-rise Buildings)

  • 최규출
    • 한국화재소방학회논문지
    • /
    • 제23권1호
    • /
    • pp.63-69
    • /
    • 2009
  • 건축법 시행령 제36조에는 3층 이상의 건축물로 문화 및 집회시설 중 공연장이나 위락시설로 바닥면적이 1천 $m^2$ 이상인 건축물은 옥외피난계단을 설치하도록 하고 있다. 도시의 인구집중화와 함께 고층빌딩의 증가는 인적재난에 대한 다양한 대비책을 요구하고 있다. 최근 10년 동안 고층빌딩 증가율은 85%로 급등하였다. 이러한 고층빌딩의 증가는 도시지역의 인적재난으로 이어져 화재발생 시 많은 인명피해와 재산피해를 동반한다. 고층빌딩에서 화재가 발생하였을 때 가장 어려운 소방활동이 피난활동이다. 상층으로 확산되는 연기 때문에 고층빌딩에서의 피난로 확보는 인명피해를 최소화 시키는 유일한 방법이다. 고층빌딩에서 직통계단이나 옥내계단으로는 피난로 확보가 어려워 고층빌딩 일수록 옥외피난계단이 필요하다. 옥외피난계단 설치에 관한 현행 법규는 너무 미미(微微)하여 고층빌딩의 피난로 확보대책으로는 적당치 못하다. 고층빌딩의 피난로 확보를 위하여 고층빌딩군(群)의 분류에 해당되는 10층 이상의 건축물에는 옥외피난계단 설치를 의무화하도록 관련법을 개정토록 하여야 한다.

고시원 화재시 복도 및 비상구 폭에 따른 피난소요시간 변화에 관한 연구 (A Study on the Variation of Evacuation Time according to the Width of Corridor and the Emergency Exit in Gosiwon's Fire State)

  • 김진호;양정훈;석호태
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.133-138
    • /
    • 2009
  • The purpose of this study is to present an alternative plan in order to reduce the required time to flee from the inside of the gosiwon in danger. The data were derived from changing the width of corridors and emergency exits and the number of stairs in the building EXODUS, which is computer simulation program, The analyzed conclusions from the data are following as below (1) Increasing the exits and the number of stairs are efficient to reduce the accumulated time for standing by. (2) Increasing the number of stairs is efficient to decrease the distance to get out of the building to exit. (3) Increasing the number of stairs is efficient to reduce the time to get out of the building to exit.

  • PDF

대학교육시설(大學敎育施設)의 복도(複道).계단(階段) 폭(幅)과 보행자(步行者) 밀도(密度)가 피난시간(避難時間)에 미치는 영향(影響)에 관한 연구 (A Study on the Evacuation Time According to the Width of Corridor, Stair and Density of Evacuee in University Education Facilities)

  • 이정수;문재호
    • 교육시설
    • /
    • 제17권1호
    • /
    • pp.13-20
    • /
    • 2010
  • The aims of this study are to verify the relationships of evacuee speed and affections to the evacuation time according to the width of corridor and stairs in university education facilities. To achieve these purposes, the present conditions of university education facilities were analyzed, and the evacuation experiments were executed in relation to the width of corridor and stairs. The results of this study are as follows ; (1) The deviations of numbers of residents per stair is very high, and the number and width of stairs, corridors are only depend on the minimum guidelines of building code, not considering the residents' evacuation. (2) The width of corridor and stairs are affects on the evacuation speed and time. The rate of decreasing speed is large in stairs, and also the possibility of danger is increasing depend on the speed and density.

미켈란젤로의 캄피돌리오 언덕계획의 특성에 관한 연구 (A Study on the Characteristics of Campidoglio Hill Plan by Michelangelo)

  • 김석만
    • 건축역사연구
    • /
    • 제18권6호
    • /
    • pp.85-101
    • /
    • 2009
  • The Purpose of this paper is a study on the characteristics of Campidoglio hill plan by Michelangelo. 1. The plan of the Campidoglio hill is composed of the harmonized and united space, in spite of the existing conditions of a steep flight of land, a irregular site shape, a building of each other different dimension and form. And it is newly changed by site left through the modification of existing building elevation, utilization of existing building for new planning, connection with existing building and newly planned building from plaza composition of trapezoid form. 2. The concept of planning of the Campidoglio hill is planned by compromising for requirements of Baroque after Renaissance which urban planning characteristics of Baroque is as the relation with urban street through a inclined stairs and process such as street-approach stairs-plaza-symbol of inside plaza-building. 3. The section plan of the Campidoglio hill is planned by which can be easily approached to the plaza through the inclined stairs of gentle angle from street at the center east-west direction of main axis such as main axis, utilizing the existing site shape, and it is composed of the convex shape ascending gently at the center central part of the plaza. 4. The plan of the Campidoglio hill is composed of the elation with the axis of existing Senatorio palace, building planning of perfect balance, plaza composition of reversed trapezoid form bybuilding planning, central concentrated planning of buildings surrounding plaza. 5. The three palace of the plan of the Campidoglio hill is composed of the concept as theater which the stage background forms the front elevation of Senatorio palace higher two palace and the wings of either side of stage form the front elevation of Conservatori palace and Nuovo palace, surrounding three palace elevation around plaza of trapezoid form.

  • PDF

계단에서 올라가는 군집보행의 속도에 관한 조사 및 특성에 관한 연구 (A Study on the Character and Walking Velocity of Crowd Going up Stairs)

  • 박재성
    • 한국화재소방학회논문지
    • /
    • 제25권1호
    • /
    • pp.72-77
    • /
    • 2011
  • 현대 도시는 수평적 토지이용의 제한, 지가 상숭, 인간 요구의 다양화 등으로 인하여 도시기능의 일부를 지하공간으로 흡수하고자 하는 노력이 증가하는 추세이다. 따라서 건축물의 지하층, 지하철 역사 등이 점차 대심도화 되어 지하공간에서 지상으로 피난에 대한 안전성 여부가 부각되고 있다. 그동안 계단에서 군집보행에 관한 연구는 내려가는 군집보행을 중심으로 진행되어 왔으며, 계단에서 올라가는 군집보행에 대한 연구는 거의 전무한 상황이다. 본 연구에서는한 방향 군집유통이 형성되는 지하철 역사 숭강장 내 계단에서 올라가는 군집의 밀도에 따른 보행속도를 직접 실촉하여 조사하였다. 올라가는 보행은 실측결과 경사도 $23^{\circ}$에서 관계식 V=0.638-0.0949p에 의해 보행속도가 결정되며, 이를 일본건축학회에서 제안하는 계단 경사도에 따른 평균보행속도를 근거로 환산하면 경사도 $30^{\circ}$에서는 V=0.597-0.1067p가 되는 것으로 분석되었다.

건물 층별에 따른 라돈농도에 관한 연구 (The Study of Radon Concentration According to Building of Stars)

  • 김영식
    • 한국환경보건학회지
    • /
    • 제31권1호
    • /
    • pp.94-98
    • /
    • 2005
  • This study was carried out to provide radon concentration and exposure in building. The average radon concentrations of building was measured 1.37 pCi/L in basement, 0.95 pCi/L in 1st layer, 0.74 pCi/L in 2nd layer, 0.56 pCi/L in 3rd layer, and 0.4 pCi/L in 4th layer, respectively. The average radon concentration of basement was measured the higher than any other stairs. Daily average distribution of radon concentrations in building shown that radon concentrations measured in morning at 8hr was the highest value. Monthly average distribution of radon concentrations shown 0.28 ${\pm}$ 0.17 pCi/L in April and 0.82 pCi/L in December that was the highest value. The average concentrations of radon was measured 0.38pCi/L in spring. 0.44 pCi/L in summer, 0.53 pCi/L in autumn, and 0.67 pCi/L in winter, respectively. This result shown that the average concentrations of radon in winter was the higher than any other seasons. That reasons was supposed that effect of number of exchanges and using air conditions was the higher in summer than winter.

실규모 수리모형실험을 이용한 계단 흐름에서의 안전성에 관한 연구 (A Study on Safety at Stairs Flow using the Real-scale Hydraulic Model Experiment)

  • 김명환;이두한
    • Ecology and Resilient Infrastructure
    • /
    • 제5권4호
    • /
    • pp.210-218
    • /
    • 2018
  • 본 연구에서는 침수된 계단 흐름의 변화에 따른 인명의 대피 안전성을 분석하기 위하여 실규모의 계단 수로 모형을 제작하여 수리 실험을 수행하였다. 실험에서는 계단 각각의 단에서의 수심과 유속을 측정하였으며 이를 이용하여 단위 폭당 비력을 산출하였다. 그리고 산출된 단위 폭당 비력 값을 이용하여 침수된 계단 흐름의 변화에 따른 구간별 대피 안전성을 제시하였다. 실험을 통해 측정된 수심 값과 Ishigaki의 단위 폭당 비력에 따른 대피 안전성 그래프를 결합하여 분석한 결과 계단 흐름 수심 0.20 m 이상에서는 도움 없이 성인 남성의 대피가 어려운 것이 확인되었으며, 수심 0.15 m 이상에서는 성인 여성과 노인 남성이 도움 없이 대피가 어려운 것으로 확인되었다. 노인 여성의 경우 수심 0.13 m 이상에서 도움 없이 대피가 어려운 것으로 나타났다.

Simulation Analysis of Safety Evacuation in University Experiment Building

  • Tao Zhang;Ha-Sung Kong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제16권2호
    • /
    • pp.218-226
    • /
    • 2024
  • According to the actual situation of a university, the emergency evacuation simulation is modeled based on the physical sign, evacuation speed and personnel ratio using the pathfinder software.The experimental construction export utilization rate is compared with the preliminary simulation scenario. The simulation results show that the utilization rate of evacuation stairs and evacuation exits is significantly improved.The optimized solution can provide the most effective evacuation passage, and the research results can provide the basis for the rational planning and management of evacuation passage in university experiment building.