• Title/Summary/Keyword: building of stairs

Search Result 78, Processing Time 0.032 seconds

Study on 3D Numerical Analysis of Stack Effect Reduction in Stairwell of Building (건축물 계단에서의 연돌효과 저감방안에 대한 3차원 수치해석 연구)

  • Kim, Jung-Yup;Kim, Ji-Seok
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.3
    • /
    • pp.152-157
    • /
    • 2015
  • Stack effect on high-rise building have negative effect on living environment, energy and life-safety aspect. Thus, it's necessary to find the measure to reduce the stack effect. As a result of field test on a 31-story building, a circulating type stack effect reduction technology was developed, which supplies air in the low stairs and discharges air in the high stairs. To evaluate the performance of this circulating type stack effect reduction technology on building stairs, a 3D numerical analysis was carried out by using Momentum Loss Model for analyzing leakage flow between compartments in a building. Consequently, numerical analysis proved that the stack effect on building stairs was reduced by a circulating type stack effect reduction technology.

A Study on the Characteristics of Architectural Publicity for Stairs in the Office Buildings (업무공간계단의 공공적 특성에 관한 연구)

  • Lee, Kyung-Eun
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.12
    • /
    • pp.682-689
    • /
    • 2011
  • The purpose of this study is to investigate the importance of stairs and to provide information on exploring desirable directions for stairs' designs by analyzing the architectural publicity characteristics for stairs in the office buildings. The research method was as follows: 1) Preparatory study and literature reviews to extract the elements of architectural publicity 2) Based on the elements of architectural publicity, each stairs in the office building was evaluated. The results of the case study show that the stairs of office building built since 2000 were characterized by improved architectural publicity. It was concluded that the stairs in an office building should accommodate and provide architectural publicity characteristics such as approachability, openness and amenity for enhancing the interactive atmosphere within the people in the office building.

A Study on the Efficiency of Evacuation Exterior Stairs in High-rise Buildings (고층빌딩에서 옥외피난계단의 효용성에 관한 연구)

  • Choi, Kyu-Chool
    • Fire Science and Engineering
    • /
    • v.23 no.1
    • /
    • pp.63-69
    • /
    • 2009
  • Article 36 of the Building Code Enforcement Ordinance requires that an exterior evacuation stairs be installed for the buildings of three stories and over with cultural facilities or gathering places which have over $1,000\;m^2$ floor area of public performance halls or recreational facilities. The concentration of population together with the increase of high-rise buildings in cities call for various precautionary measures to be taken against human disasters. For the past ten years high-rise buildings showed 85% of increase, marking a steep rise. This increase of high-rise buildings may lead to human disasters in urban areas and, in case of fire breakout, may cause great loss of human lives and property damages. The most difficult fire-fighting activities in high-rise building fires are those of evacuation. Because smoke spreads through the upper floors, the securement of evacuation route in high-rise buildings may be the only way to minimize loss of lives. In high-rise buildings exterior escape stairs are necessary because it is difficult to secure evacuation route with only direct stairs or interior stairs. The Building Code now in force provides insignificant coverage on the exterior evacuation route installment and therefore becomes an inadequate means for evacuation route securement in high-rise building fires. To compensate for this inadequacy the Building Code should be revised to include a mandatory clause that an exterior evacuation stairs be established for the buildings of ten stories and over which can be categorized into high-rise building group.

A Study on the Variation of Evacuation Time according to the Width of Corridor and the Emergency Exit in Gosiwon's Fire State (고시원 화재시 복도 및 비상구 폭에 따른 피난소요시간 변화에 관한 연구)

  • Kim, Jin-Ho;Yang, Jeong-Hoon;Seok, Ho-Tae
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.133-138
    • /
    • 2009
  • The purpose of this study is to present an alternative plan in order to reduce the required time to flee from the inside of the gosiwon in danger. The data were derived from changing the width of corridors and emergency exits and the number of stairs in the building EXODUS, which is computer simulation program, The analyzed conclusions from the data are following as below (1) Increasing the exits and the number of stairs are efficient to reduce the accumulated time for standing by. (2) Increasing the number of stairs is efficient to decrease the distance to get out of the building to exit. (3) Increasing the number of stairs is efficient to reduce the time to get out of the building to exit.

  • PDF

A Study on the Evacuation Time According to the Width of Corridor, Stair and Density of Evacuee in University Education Facilities (대학교육시설(大學敎育施設)의 복도(複道).계단(階段) 폭(幅)과 보행자(步行者) 밀도(密度)가 피난시간(避難時間)에 미치는 영향(影響)에 관한 연구)

  • Lee, Jeong-Soo;Mun, Jae-Ho
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.17 no.1
    • /
    • pp.13-20
    • /
    • 2010
  • The aims of this study are to verify the relationships of evacuee speed and affections to the evacuation time according to the width of corridor and stairs in university education facilities. To achieve these purposes, the present conditions of university education facilities were analyzed, and the evacuation experiments were executed in relation to the width of corridor and stairs. The results of this study are as follows ; (1) The deviations of numbers of residents per stair is very high, and the number and width of stairs, corridors are only depend on the minimum guidelines of building code, not considering the residents' evacuation. (2) The width of corridor and stairs are affects on the evacuation speed and time. The rate of decreasing speed is large in stairs, and also the possibility of danger is increasing depend on the speed and density.

A Study on the Characteristics of Campidoglio Hill Plan by Michelangelo (미켈란젤로의 캄피돌리오 언덕계획의 특성에 관한 연구)

  • Kim, Seok-Man
    • Journal of architectural history
    • /
    • v.18 no.6
    • /
    • pp.85-101
    • /
    • 2009
  • The Purpose of this paper is a study on the characteristics of Campidoglio hill plan by Michelangelo. 1. The plan of the Campidoglio hill is composed of the harmonized and united space, in spite of the existing conditions of a steep flight of land, a irregular site shape, a building of each other different dimension and form. And it is newly changed by site left through the modification of existing building elevation, utilization of existing building for new planning, connection with existing building and newly planned building from plaza composition of trapezoid form. 2. The concept of planning of the Campidoglio hill is planned by compromising for requirements of Baroque after Renaissance which urban planning characteristics of Baroque is as the relation with urban street through a inclined stairs and process such as street-approach stairs-plaza-symbol of inside plaza-building. 3. The section plan of the Campidoglio hill is planned by which can be easily approached to the plaza through the inclined stairs of gentle angle from street at the center east-west direction of main axis such as main axis, utilizing the existing site shape, and it is composed of the convex shape ascending gently at the center central part of the plaza. 4. The plan of the Campidoglio hill is composed of the elation with the axis of existing Senatorio palace, building planning of perfect balance, plaza composition of reversed trapezoid form bybuilding planning, central concentrated planning of buildings surrounding plaza. 5. The three palace of the plan of the Campidoglio hill is composed of the concept as theater which the stage background forms the front elevation of Senatorio palace higher two palace and the wings of either side of stage form the front elevation of Conservatori palace and Nuovo palace, surrounding three palace elevation around plaza of trapezoid form.

  • PDF

A Study on the Character and Walking Velocity of Crowd Going up Stairs (계단에서 올라가는 군집보행의 속도에 관한 조사 및 특성에 관한 연구)

  • Park, Jae-Sung
    • Fire Science and Engineering
    • /
    • v.25 no.1
    • /
    • pp.72-77
    • /
    • 2011
  • The effort of transferring some parts of urban functions to the underground space is growing trend among modem cities because of the limit of horizontal land use, the rise of land value, the diversification of human desire, etc. Thus, the basement of building and the subway station have deepened. It calls our attention to safety about evacuation from the underground space to the ground. Until now, the study about crowding walk in stairs has been progressed, focusing on the crowding walk that is going down the stairs, and there is no study about crowding walk that is going up the stairs. This study measured walking pace by crowd density that is going up the stairs in the subway station stairs making one-way movement of crowd. The actual survey showed that the mathematical relation 'V=0.638-0.0949p' determines going up walking velocity at a gradient of $23^{\circ}$, and the mathematical relation will be 'V=0.597-0.1067p' at a gradient of $30^{\circ}$, when it is converted, based on the average walking velocity of crowd by the slope of the stairs which is recommended by Architectural Institute of Japan.

The Study of Radon Concentration According to Building of Stars (건물 층별에 따른 라돈농도에 관한 연구)

  • Kim, Young-Sik
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.1
    • /
    • pp.94-98
    • /
    • 2005
  • This study was carried out to provide radon concentration and exposure in building. The average radon concentrations of building was measured 1.37 pCi/L in basement, 0.95 pCi/L in 1st layer, 0.74 pCi/L in 2nd layer, 0.56 pCi/L in 3rd layer, and 0.4 pCi/L in 4th layer, respectively. The average radon concentration of basement was measured the higher than any other stairs. Daily average distribution of radon concentrations in building shown that radon concentrations measured in morning at 8hr was the highest value. Monthly average distribution of radon concentrations shown 0.28 ${\pm}$ 0.17 pCi/L in April and 0.82 pCi/L in December that was the highest value. The average concentrations of radon was measured 0.38pCi/L in spring. 0.44 pCi/L in summer, 0.53 pCi/L in autumn, and 0.67 pCi/L in winter, respectively. This result shown that the average concentrations of radon in winter was the higher than any other seasons. That reasons was supposed that effect of number of exchanges and using air conditions was the higher in summer than winter.

A Study on Safety at Stairs Flow using the Real-scale Hydraulic Model Experiment (실규모 수리모형실험을 이용한 계단 흐름에서의 안전성에 관한 연구)

  • Kim, Myounghwan;Lee, Du Han
    • Ecology and Resilient Infrastructure
    • /
    • v.5 no.4
    • /
    • pp.210-218
    • /
    • 2018
  • In this study, a real-scale stairway model was constructed to analyze the evacuation safety of human life due to the change of flooded stair flow. In the experiment, the water depth and flow velocity at each stage of the stairs were measured and the specific force per unit width was calculated. Using the calculated the specific force per unit width, the evacuation safety of each steps of stairs according to the change of the flooded stair flow was presented. Finally, the depth of water measured by the experiment and the evacuation safety graph of "Ishigaki" by the specific force per unit width were combined to analyze the evacuation safety by depth. As a result, it has been found that evacuation of adult man is difficult without help at the flow depth of 0.20 m or more. And it has been found that evacuation of adult women and elderly men are difficult without help at the flow depth of 0.15 m or more. Finally, it has been found that evacuation of elderly women is difficult without help at depth of 0.13 m or more.

Simulation Analysis of Safety Evacuation in University Experiment Building

  • Tao Zhang;Ha-Sung Kong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.16 no.2
    • /
    • pp.218-226
    • /
    • 2024
  • According to the actual situation of a university, the emergency evacuation simulation is modeled based on the physical sign, evacuation speed and personnel ratio using the pathfinder software.The experimental construction export utilization rate is compared with the preliminary simulation scenario. The simulation results show that the utilization rate of evacuation stairs and evacuation exits is significantly improved.The optimized solution can provide the most effective evacuation passage, and the research results can provide the basis for the rational planning and management of evacuation passage in university experiment building.