• 제목/요약/키워드: building energy demand

검색결과 339건 처리시간 0.023초

건물에너지 분석 방법론 비교 - Steady-state simulation에서부터 Data-driven 방법론의 비교 분석 - (Comparing Methodology of Building Energy Analysis - Comparative Analysis from steady-state simulation to data-driven Analysis -)

  • 조수연;이승복
    • KIEAE Journal
    • /
    • 제17권5호
    • /
    • pp.77-86
    • /
    • 2017
  • Purpose: Because of the growing concern over fossil fuel use and increasing demand for greenhouse gas emission reduction since the 1990s, the building energy analysis field has produced various types of methods, which are being applied more often and broadly than ever. A lot of research products have been actively proposed in the area of the building energy simulation for over 50 years around the world. However, in the last 20 years, there have been only a few research cases where the trend of building energy analysis is examined, estimated or compared. This research aims to investigate a trend of the building energy analysis by focusing on methodology and characteristics of each method. Method: The research papers addressing the building energy analysis are classified into two types of method: engineering analysis and algorithm estimation. Especially, EPG(Energy Performance Gap), which is the limit both for the existing engineering method and the single algorithm-based estimation method, results from comparing data of two different levels- in other words, real time data and simulation data. Result: When one or more ensemble algorithms are used, more accurate estimations of energy consumption and performance are produced, and thereby improving the problem of energy performance gap.

건물 에너지 상세 해석을 통한 소형 열병합 발전 및 히트펌프 복합 시스템의 경제성 분석 (Energy and Economic Analysis of Heat Recovery Cogeneration Loop Integrated with Heat Pump System by Detailed Building Energy Simulation)

  • 서동현;고재윤;박률
    • 설비공학논문집
    • /
    • 제21권2호
    • /
    • pp.71-78
    • /
    • 2009
  • Up until recently, the energy and the economic analysis of a cogeneration system have been implemented by a manual calculation that is based on monthly thermal loads of buildings. In this study, a cogeneration system modeling validation with a detail building energy simulation, eQUEST, for a building energy and cost prediction has been implemented. By analyzing the hourly building electricity and thermal loads, it enables users to decide proper cogeneration system capacity and to estimate more accurate building energy consumption. eQUEST also verified the energy analysis when the heat pump system is integrated with the cogeneration system. The mechanical system configuration benefits from the high efficiency heat pump system while avoiding the building electricity demand increase. Economic analysis such as LCC (Life Cycle Cost) method is carried out to verify economical benefits of the system by applying actual utility rates of KEPCO(Korea Electricity Power COmpany) and KOGAS(KOrea GAS company).

STPV의 건물 에너지 성능에 대한 파라메트릭 분석 (Parametric Analysis of Building Energy Impact of Semi-transparent PV)

  • 곽인규;문선혜;허정호
    • 대한건축학회논문집:구조계
    • /
    • 제34권7호
    • /
    • pp.35-42
    • /
    • 2018
  • Semi-transparent Photovoltaics (STPV) works as an exterior material replacing windows as well as functioning as a electricity generator. As a result, it also affects the building's heating, cooling and lighting loads. In this study, we used the concept of Net Electricity Benefit(NEB) to conduct a parametric analysis of building energy impact of STPV. The NEB of STPV is from $-1kWh/m^2$ to $6kWh/m^2$. Since NEB represents the amount of energy increase or decrease when STPV is applied compared to the standard window, a value of 0 or less means that the demand for building energy can be increased rather than applying a general window having high thermal performance and high visible light transmittance value. Therefore, it is necessary to perform a comprehensive performance evaluation considering both the performance evaluation based on the existing power generation performance and the influence on the building energy.

의료시설 에너지절약 운영방법 도출을 위한 사례분석을 통한 에너지 영향요소 분석 (Case Study for Energy Conservation Measures of Hospital Buildings Using the Analysis of Energy Consumption Structure)

  • 이상문;조진균
    • 한국태양에너지학회 논문집
    • /
    • 제39권2호
    • /
    • pp.57-69
    • /
    • 2019
  • Because the hospital building operates 24 hours a day, 365 days a year for treatment and restoration of patients, it has a different pattern of energy use than that of ordinary buildings. Hospitals contribute to energy consumption and have a negative environmental impact. This study aims to find how meaningful energy performance, reflecting good energy management and ECMs, can be operated for hospital buildings, a category encompassing complex buildings with different systems and large differences between them. In this study, we proposed the energy diagnosis & evaluation method and energy management process to verify energy saving through operation data based on system & facility characteristics, operation pattern and energy consumption characteristics of hospital building. Energy consumption structures were surveyed throughout 4 reference hospital in Seoul, Korea. Findings confirm that different hospital departments have hugely different energy-demand profiles. Energy efficiency and energy saving potentials are presented. The energy performance analysis can be applied to a wide range of problems in energy-system operation.

건물 단지에 대한 에너지 수요 예측 프로그램 개발 (Development of a Building Energy Demand Estimator)

  • 정모;박화춘;임용훈
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.127-132
    • /
    • 2009
  • A Microsoft Access application program is developed to calculate energy demands for a Community Energy System (CES) composed of various types of buildings. The field-measured heating, hot water, cooling, and electricity energy consumptions for 14 types of building are systematically organized in forms of database and hourly loads for a span of year (8760 hours) are generated through an automated statistical procedure. User-friendly standard windows interfaces are provided to assist non-expert end users.

  • PDF

The Indoor Environmental Quality Improving and Energy Saving Potential of Phase-Change Material Integrated Facades for High-Rise Office Buildings in Shanghai

  • Jin, Qian
    • 국제초고층학회논문집
    • /
    • 제6권2호
    • /
    • pp.197-205
    • /
    • 2017
  • The conflict between indoor environmental quality and energy consumption has become an unneglectable problem for highrise office buildings, where occupants' productivity is highly affected by their working environment. An effective Façade, therefore, should play the role of an active building skin by adapting to the ever-changing external environment and internal requirements. This paper explores the energy-saving and indoor environment-improving potential of a phase-change material (PCM) integrated Façade. Building performance simulations, combined with parametric study and sensitivity analysis, are adopted in this research. The result quantifies the potential of a PCM-integrated Façade with different configurations and PCM properties, taking as an example a south-oriented typical office room in Shanghai. It is found that a melting temperature of around $22^{\circ}C$ for the PCM layer is optimal. Compared to a conventional Façade, a PCM-integrated Façade effectively reduces total energy use, peak heating/cooling load, and operative temperature fluctuation during the periods of May-July and November-December.

3L House의 설계, 시공 및 평가 (The Technology Applied 3 Liter House, Super Energy Saving Building)

  • 박선효;박용승;원종서
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.814-819
    • /
    • 2006
  • This research is on the design and introducing of integrated thermal performance of super energy saying building, called 3 Liter house which can be sustained with 3 liter oil(kerosene) per $yr.m^2$. 3 liter houses(Passive houses) offer extended living comfort with only 15 to 20% of the space heating demand of conventional new building. To achieve this purpose, the efficiency of building components is improved, such as walls, windows or ventilation system and the construction technology is improved, such as the prevention of thermal bridge and the air tightness. The fuel cell is used as alternative energy. Energy consumption of 3L house is 2.08 [liter/$yr.m^2$] in monitoring result of $2006/2/1{\sim}2/7$ and ACH50 is 0.67 in result of Blow Door Test, therefore 3L House is well- insulated and well- airtighted house.

  • PDF

학교 건물의 신재생에너지 적용을 위한 수요/공급 분석 및 평가에 관한 연구 (Study on the Feasibility Test of Renewable Energy Systems for Schools)

  • 남현진;박은미;배민호;김재민;박효순
    • 설비공학논문집
    • /
    • 제22권4호
    • /
    • pp.197-204
    • /
    • 2010
  • Schools are one of the most suitable buildings for renewable energy systems because they have favourable demand profiles for renewable energy system (e.g. solar thermal collector, photovoltaic panels), modular-based building plan and large open spaces (e.g. play ground, gardens, roof) for the installation. This paper presents a methodology of the feasibility test for renewable energy systems to be installed at schools. The methodology is based on the analysis of the demand/supply profiles dynamic matching. a case study is also presented to test the applicability of the proposed assessment methodology.

동적 시뮬레이션을 이용한 건물 에너지 성능 비교분석 (Comparative Analysis of Energy Performance using Dynamic Simulation)

  • 배상무;이경희;여성구;김은지;양재광;전재영;이준혁;배영민;김성훈;강영모
    • 동력기계공학회지
    • /
    • 제21권6호
    • /
    • pp.62-67
    • /
    • 2017
  • In order to achieve high efficiency of energy use and environment-friendly architectural design, various loads such as cooling, heating and hot water required by the building sector must be accurately predicted. Many studies used dynamic simulation tool to evaluate and analyze building energy performance. However, there are few studies on the comparative analysis of load results by each simulation and the evaluation of simulation characteristics and functions. In this study, the cooling, heating loads and energy demand of the buildings were evaluated using three dynamic simulations for the building with the same input conditions, and the characteristics of each simulation were compared and analyzed through the results. As a result of simulation comparative analysis, cooling, heating load and energy demand was lowest in square type and north-south direction conditions.

조명제어시스템을 위한 효율적인 계측 및 검증(M&V) 기법 연구 (A Study on the Effective M&V Method for the Lighting Control System)

  • 김정욱;부창진;김정혁;오성보;김호찬
    • 에너지공학
    • /
    • 제20권3호
    • /
    • pp.216-223
    • /
    • 2011
  • 본 논문에서는 다양한 공장과 빌딩에서 조명제어시스템을 대상으로 계측 및 검증(M&V) 방법을 사용하여 효율적인 에너지 절약 방법을 제시한다. 에너지 가격을 줄이기 위해서는 전력피크시간에 제어가능한 다양한 수요자원을 고려하는 필요하지만, 일반적으로 빌딩에서 고려되는 수요자원은 피크전력이다. 본 논문에서는 M&V 방법을 사용하여 전력소비량을 줄일 수 있는 새로운 에너지절약방법을 제안하고 현장계측시스템을 구성하고 시뮬레이션 방법을 통해 제안된 방법이 효과적임을 확인한다.