• Title/Summary/Keyword: building dynamic characteristics

Search Result 372, Processing Time 0.029 seconds

Measurements on the Characteristics of Dynamic and Vertical Vibration Transfer according to floors of Building Structures using Accelerometer and Dynamic signal analyzer (가속도계와 동적신호분석기를 이용한 건축물 바닥슬래브 동특성 및 수직진동 전달특성 측정)

  • Chun Ho-Min
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.29-34
    • /
    • 2006
  • In general, the vertical vibration problems for .strength of members and serviceability of building structures are not considered in structural design process, but the prediction of the vertical vibration is very important and essential to structural design process. This study aims to investigate the characteristics of vertical vibration in terms of the transfer of horizontal directions on the rahmen building structures. In order to examine the characteristics of vertical vibration, the modal test and the impact (heel-drop and hammer) excitation experiments were conducted several times on three building structures. The results from the experiments are analyzed and compared. with the results. The results of this study suggest that the characteristics of vertical vibration transfer in horizontal way are effected from the fundamental frequency of the slabs and excitation forces.

  • PDF

Seismic and vibration tests for assessing the effectiveness of GFRP for retrofitting masonry structures

  • Michelis, Paul;Papadimitriou, Costas;Karaiskos, Grigoris K.;Papadioti, Dimitra-Christina;Fuggini, Clemente
    • Smart Structures and Systems
    • /
    • v.9 no.3
    • /
    • pp.207-230
    • /
    • 2012
  • Full-scale shake table seismic experiments and low-amplitude vibration tests on a masonry building are carried out to assess its seismic performance as well as study the effectiveness of a new multifunctional textile material for retrofitting masonry structures against earthquakes. The un-reinforced and the retrofitted with glass fiber reinforced polymer (GFRP) strips masonry building was subjected to a series of earthquake excitations of increasing magnitude in order to progressively induce various small, moderate and severe levels of damage to the masonry walls. The performance of the original and retrofitted building states is evaluated. Changes in the dynamic characteristics (lowest four modal frequencies and damping ratios) of the building are used to assess and quantify the damage states of the masonry walls. For this, the dynamic modal characteristics of the structure states after each earthquake event were estimated by performing low-amplitude impulse hammer and sine-sweep forced vibration tests. Comparisons between the modal results calculated using traditional accelerometers and those using Fiber Bragg Grating (FBG) sensors embedded in the reinforcing textile were carried on to investigate the reliability and accuracy of FBG sensors in tracking the dynamic behaviour of the building. The retrofitting actions restored the stiffness characteristics of the reinforced masonry structure to the levels of the original undamaged un-reinforced structure. The results show that despite a similar dynamic behavior identified, corresponding to reduction of the modal frequencies, the un-reinforced masonry building was severely damaged, while the reinforced masonry building was able to withstand, without visual damage, the induced strong seismic excitations. The applied GFRP reinforcement architecture for one storey buildings was experimentally proven reliable for the most severe earthquake accelerations. It was easily placed in a short time and it is a cost effective solution (covering only 20% of the external wall surfaces) when compared to the cost for full wall coverage by GFRPs.

Dynamic Characteristics of Full-Scale Viscoelastic Dampers (실물크기 점탄성 감쇠기의 동적 특성)

  • 민경원
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.10a
    • /
    • pp.367-374
    • /
    • 1999
  • this paper focuses on the dynamic characteristics of full-scale viscoelastic dampers through the experimental study. Viscoelastic dampers which dissipate the response energy of a building under earthquake excitation make a role of increasing damping capacity of the building. Therefore it is important to recognize the damping behavior of viscoelastic dampers. Full-scale viscoelastic dampers are made of three types of rubbers for experimental test. The hysteretic behavior is obtained through the load-deformation experiment over the various loading frequencies and damper strains The experimental results show the good performance of viscoelastic dampers under earthquake excitations,

  • PDF

Vibration Characteristics of a Three-Story Reinforced Concrete Building Before and After Damage (3층 철근콘크리트조 건물의 손상전후의 진동특성)

  • Yoon, Sung-Won;Park, Yong;Ji, Jung-Hwan;Lim, Jae-Hwi;Jang, Dong-Wo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.9 no.3
    • /
    • pp.59-66
    • /
    • 2009
  • Dynamic characteristics such as frequency and damping ratio in the ambient state of building has been progressed in domestic and foreign. However, there has not been any deep research of dynamic characteristics of full-scale structure using vibration measurement of the building damaged up to failure. Dynamic characteristics of three-story reinforced concrete building was evaluated before and after it was damaged by using a actuator. Dynamic characteristics is reviewed and compared with previous study. Ambient vibration and human excitation test were applied. After 120mm horizontal displacement by actuator, frequency of long and short direction is reduced to 34.3%, 33.7% and damping ratio is reduced to 36.5%, 19.5% respectively.

  • PDF

Preliminary study for Vertical Dynamic Site Layout Planning of High-Rise Building Construction (고층공사 가설시설물의 동적수직배치 최적화를 위한 기초연구)

  • Pyo, Kiyoun;Lee, Dongmin;Lim, Hyunsu;Cho, Hunhee;Kang, Kyung-In
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.39-40
    • /
    • 2018
  • The goal of site layout planning(SLP) is to maximize the productivity and efficiency of the construction by reducing travel distance and material handling cost and manpower. However, SLPs are static layout schemes, which cannot be reorganized during the construction process to correspond with errors, phase transition, changing working environments on the site. To solve this problem, researches on dynamic site layout planning(DSLP) are emerging. This preliminary study clarifies characteristics of temporary facility's variables to develop the vertical DSLP algorithm of high-rise building construction.

  • PDF

System Identification of a Full Scale Five-story building for Vibration Controller design (진동제어기 설계를 위한 실물크기 5층 건물의 시스템 식별)

  • Min, Kyung-Won;Lee, Young-Cheol;Lee, Sang-Hyun;Park, Min-Kyu;Kim, Doo-Hoon;Park, Jin-Il;Jeong, Jeoung-Kyo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.676-681
    • /
    • 2002
  • System Identification is carried out for a full scale five-story builing to design a vibration controller. Dynamic characteristics such as natural frequencies, damping ratios, and modes are obtained from the input/output information by both sine-sweep method and white noise method. The active mass driver installed on the five floor is applied as external loading to move the building and each floor acceleration is measured and processed for the system identification. The identified building will be experimentally investigated again with viscoelastic dampers installed at inter-stories to obtain the response behavior. Corresponding result will be presented soon.

  • PDF

Study on Integrity Assessment of Pile Foundation Based on Seismic Observation Records

  • KASHIWA, Hisatoshi
    • International Journal of High-Rise Buildings
    • /
    • v.9 no.4
    • /
    • pp.369-376
    • /
    • 2020
  • Given the importance of quickly recovering livelihoods and economic activity after an earthquake, the seismic performance of the pile foundation is becoming more critical than before. In order to promote seismic retrofit of the pile foundations, it is necessary to develop a method for evaluating the seismic performance of the pile foundation based on the experimental data. In this paper, we focus on the building that was suffered severe damage to the pile foundation, conduct simulation analyses of the building, and report the results of evaluating the dynamic characteristics when piles are damaged using a system identification method. As a result, an analysis model that can accurately simulate the behavior of the damaged building during an earthquake was constructed, and it was shown that the system identification method could extract dynamic characteristics that may damage piles.

Evaluation of Seismic Design Force by Earthquake Response Analysis of Water Tanks Installed in RC Buildings (건축물에 설치된 물탱크의 지진응답해석을 통한 설계하중 평가)

  • Baek, Eun Rim;Oh, Ji Hyeon;Choi, Hyoung Suk;Lee, Sang Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.23 no.4
    • /
    • pp.221-229
    • /
    • 2019
  • Several water tanks installed in the building were damaged during the Gyeongju earthquake (2016) and the Pohang earthquake (2017). Since a water tank for fire protection is very important component, seismic safety should be ensured. In this study, an interaction between a water tank and a building was studied by the dynamic analysis of the RC building with the water tank. In case the water tank was installed on the roof of the RC building, it was confirmed that it did not significantly affect the response of the building. Based on the result, dynamic response characteristics of the water tank in the building were studied using two SDOF models represented dynamic behavior of the water tanks under earthquake. An earthquake time-history analysis was carried out with variables of aspect ratio of the tank, story of the building, and installed location in the building using three kinds of earthquakes.

Experimental Study on the Dynamic Characteristics of the Lead Extrusion Damper (납압출댐퍼의 동특성에 관한 실험적 연구)

  • 정민기
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.482-489
    • /
    • 2000
  • The cyclic extrusion damper, Lead Extrusion Damper, was invented by the W H Robinson in order to produce the isolated buildings and bridges the damping force. Recently, LED was applied to reduce the vibration of the tall building. In this study, to verify the dynamic characteristics of LED, the tests to find out the dependences on the velocity, displacement, repeated cycle, and temperature were performed at structural lab of Unison Industrial Co. Ltd. Through the result of the dynamic characteristics. we`ll define the design parameters and apply the appropriate parts.

  • PDF

A Dynamic Analysis and Evaluation of a Building Structure due to Tunnel Blast by using Semi-Empirica Method (준경험적 방법을 이용한 터널발파 작업시 인접구조물의 동적해석 및 진동영향성 평가)

  • Son, Sung-Wan;Ru, Kuk-Hyun;Chun, Jong-Kun;Nam, Young-Sik;Kim, Dong-Gi
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.772-775
    • /
    • 2005
  • Most engineers, related to soil and civil dynamic field, have been interested in the direct dynamic design of building transmitted from soil and rock to structure due to blasting. However it is not easy to estimate the dynamic response of structures due to blasting by using analytical method because of difficulties of soil modeling, prediction of excitation force and so on. In this paper, dynamic analysis have been performed to predict vibration level and evaluate dynamic safety of structure adjacent to tunnel blast and the semi empirical method, which is based on vibration measurement data, has been employed to consider blast vibration characteristics.

  • PDF