• 제목/요약/키워드: bonding glass

검색결과 429건 처리시간 0.027초

Mold 법에 의해 제작된 FED용 전계에미터어레이의 특성 분석 (Fabrication & Properties of Field Emitter Arrays using the Mold Method for FED Application)

  • 류정탁;조경제;이상윤;김연보
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.347-350
    • /
    • 2001
  • A typical Mold method is to form a gate electrode, a gate oxide, and emitter tip after fabrication of mold shape using wet-etching of Si substrate. In this study, however, new Mold method using a side wall space structure is used in order to make sharper emitter tip with a gate electrode. Using LPCVD(low pressure chemical vapor deposition), a gate oxide and electrode layer are formed on a Si substrate, and then BPSG(Boro phospher silicate glass) thin film is deposited. After, the BPSG thin film is flowed into a mold as high temperature in order to form a sharp mold structure. Next TiN thin film is deposited as a emitter tip substance. The unfinished device with a glass substrate is bonded by anodic bonding techniques to transfer the emitters to a glass substrate, and Si substrate is etched using KOH-deionized water solution. Finally, we made sharp field emitter array with gate electrode on the glass substrate.

  • PDF

실리카흄과 현장기계함침을 이용한 유리섬유 복합재(CAF)의 콘크리트 구조물 보수보강공법 (Repair and Retrofit System of Concrete Structures using Fiber Glass and Epoxy Composite Sheets, Improved Through Utilization of Silica fume and Mechanical Saturator)

  • 유용하;권성준
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.785-792
    • /
    • 2000
  • Repair and retrofit system of concrete structures has been developed from conventional reinforced concrete overlaying, steel plate bonding and recently to fiber composite systems. Research and study on carbon, aramid, and glass fiber composite system has been actively carried out from all over the world Glass fiber composite is proved to be competitive technically and enconomically, among fiber composite system. CAF system is a system developed locally using all domestic materal, glass fabric and epoxy, and improved in shear bonding property by utilizing silica fume mixed with epoxy. All the tests on material properties, structural behavior, constructiveness at site and quality control procedure proved to be most appropriate system so far developed. Futher research work is and will be under progress for utilization of this system which will be applied to more adverse situation.

  • PDF

글라스아이오노머 시멘트 표면 처리에 따른 치과용 아말감의 전단 결합 강도에 관한 연구 (A STUDY ON BONDING STRENGTH OF DENTAL AMALGAM TO GLASS IONOMER CEMENT FOLLOWING SURFACE TREATMENT)

  • 신영주;최호영
    • Restorative Dentistry and Endodontics
    • /
    • 제19권1호
    • /
    • pp.217-230
    • /
    • 1994
  • The purpose of this study was to assess the 24-hour shear bond strength of amalgam to glass ionomer cement, using five different intermediaries. The intermediaries used in this study were Scotchbond 2 (light curing dentin adhesive), Panavia (resin cement), liquid' of glass ionomer cement (chemical curing & light curing), and uncured mixture of light curing glass ionomer cement. This study was operated with 48 specimens devided into 6 groups. The experimental groups are as follows: Group 1 : Bonded Amalgam to chemical curing glass ionomer cement with liquid of chemical curing glass ionomer. Group 2 : Bonded Amalgam to light curing glass ionomer cement with liquid of chemical curing glass ionomer. Group 3: Bonded Amalgam to light curing glass ionomer cement with resin cement. Group 4: Bonded Amalgam to light curing glass ionomer cement with light curing dentin adhesive. Group 5: Bonded Amdlgam to light curing glass ionomer cement with liquid of light curing glass ionomer. Group 6: Bonded Amalgam to light curing glass ionomer cement with uncured mixture of light curing glass ionomer cement. 30 minutes after amalgam condensation, all specimens were stored for 24 hours in water at $37^{\circ}C$ and tested with Instron (1122). The following results obtained: 1. The shear bond strength of group 6 was higher than those of the other groups (46.7 kgf/$cm^2$, p<0.05). 2. The shear bond strength of resin cement intermediary group was lower than that of the group using uncured mixture of light curing glass ionomer cement. 3. The results of group 1 and group 2 were different, even though the inter-me diaries used were same. 4. Intermediary of Group 5 did not show complete set in Scanning Electromicroscopic examination. 5. Light-curing dentin adhesive did not show any bonding ability to amalgam.

  • PDF

유리섬유를 이용한 손상된 프리스트레스트 콘크리트 보의 보강공법 개발연구 (A study on Development of Methods to Rehabilitate the Damaged Prestressed Concrete beam Using Glass Fiber)

  • 강원호;한만엽;이택성;유영민
    • 콘크리트학회지
    • /
    • 제11권2호
    • /
    • pp.167-175
    • /
    • 1999
  • 현재 국내에는 지난 35년간 프리스트레스트 콘크리트보를 이용한 합성형 교량이 매우 널리 건설, 사용되어 왔으나, 교통량의 증가와 차량하중의 증가로 노후화가 점차 가속화되고 있는 형편이다. 본 연구에서는 유리섬유를 이용하여 손상된 프리스트레스트 콘크리트 교량을 보강하는 방법의 효과를 평가하기 위하여 무보강 표준시험체와 선행 하중의 재하로 균열이 발생한 8개의 시험체에 대하여 유리섬유 보강, 외부강선 보강 및 두가지 보강 방법을 병행한 보강을 실시하여 각 보강방법의 효과를 비교, 분석하였다. 실험결과, 최대하중은 외부강선 보강 시험체와 유리섬유 보강 시험체가 모두 거의 유사한 정도의 보강효과를 발휘함으로써 유리섬유 보강공법이 손상된 프리스트레스트 콘크리트 교량의 보강에 적용될 수 있는 것으로 판명되었다. 외부강선 보강공법에서의 가장 큰 문제가 단부의 정착장치인 것과 마찬가지로 유리섬유 보강 공법의 경우에도 최대하중에 도달하기 이전에 보강재의 부착이 파괴되지 않도록 적절한 방법을 선정하는 것이 매우 중요하며, 본 연구에서 검증된 두가지 방법이 단부의 정착기능을 충분히 발휘하는 것으로 판명되어, 이들 방법들이 적절히 사용될 경우에는 설계된 내하력의 증가를 기대할 수 있는 것으로 나타났다.

Resin-modified glass ionomer cements의 파절 및 저단결합강도에 관한 실험적 연구 (An Experimental Study on the Fracture and Shear Bonding Strength of Resin-modified Glass lonomer Cements)

  • 김재곤;양철희;안수현;노용관;백병주
    • 대한소아치과학회지
    • /
    • 제25권1호
    • /
    • pp.234-248
    • /
    • 1998
  • The purpose of this study was to compare the fracture and shear bonding strength of resin-modified glass ionomer cements with composite resin and conventional glass ionomer cement Three kinds of restorative materials including a composite resin (Z 100), a conventional glass ionomer cement(Fuji II), and resin- modified glass ionomer cements(Fuji II LC, Vitremer, Dyract and Compoglass) were investigated in this study. For measurement of fracture and shear bonding strength, disk samples of the materials were prepared and cylindrical samples of the materials were bonded the flat enamel and dentin surfaces according to manufactuer's instructions. All specimen were determinated by using an Instron testing machine with a crosshead speed of 1 mm/min. Then, each treated enamel and dentin surface was observed by SEM. The following results were obtained. 1. The bi-axial flexural strength of Z 100 was highest, and Fuji n LC, Vitremer, Dyract and Compoglass were significantly higher than Fuji n (P<0.05). 2. The shear bonding strength of Z 100 on the enamel and dentin surface was higher than other experimental groups except Fuji II LC(P<0.05). Fuji II LC was significantly higher than Fuji II (P<0.05), but in the case of Vitremer, Dyract and Compoglass were similar to Fuji II (P>0.05). 3. The shear bonding strength of Z 100 and Fuji II LC on the enamel surface were highly increased as compared with dentin surface (P<0.05), but in the case of Fuji II, Vitremer, Dyract and Compoglass were not different between enamel and dentin(P>0.05). 4. In the Z 100 and Fuji II LC, obvious etched enamel surface and exposed dentinal tubules according to remove of smear layer and smear plug were observed.

  • PDF

Soda-borosilicate Glass를 결합재로 한 연삭 숫돌에 관한 연구 (A Stud on the Abrasive Wheels Bonded with Soda-borosilicate Glass)

  • 이희수;박정현;권오현
    • 한국세라믹학회지
    • /
    • 제16권3호
    • /
    • pp.178-183
    • /
    • 1979
  • The carborundum abrasive specimens bonded with a soda-borosilicate glass were prepared. Samples fired at specified temperatures with various mixing ratio and forming pressure were examined in terms of the structure, bonding strength, and microscopic observations. Increasing the forming pressure up to 400kg/$\cm^2$, the structure became denser in proportion to the forming pressure. The bonding strength was generally increased with increasing the mixing ratio (Vb/Vg), but the bloating phenomena were observed when samples were fired above 95$0^{\circ}C$ with mixing ratio above 20%, consequently, the bonding strength was decreased. Samples fired at the temperature range 900~95$0^{\circ}C$ with mixing ratio 15~30% had the dense structure with various grades.

  • PDF

A New COG Technique Using Solder Bumps for Flat Panel Display

  • Lee, Min-Seok;Kang, Un-Byoung;Kim, Young-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.1005-1008
    • /
    • 2003
  • We report a new FCOG (flip chip on glass) technique using solder bumps for display packaging applications. The In and Sn solder bumps of 40 ${\mu}m$ pitches were formed on Si and glass substrate. The In and Sn bumps were bonded at 125 at the pressure of 3 mN/bump. The metallurgical bonding was confirmed using cross-sectional SEM. The contact resistance of the solder joint was 65 $m{\Omega}$ which was much lower than that of the joint made using the conventional ACF bonding technique. We demonstrate that the new COG technique using solder bump to bump direct bonding can be applied to advanced LCDs that lead to require higher quality, better resolution, and lower power consumption.

  • PDF

ACF를 이용한 COG 접합 공정에서 도전볼의 음영비와 접촉 저항과의 관계 (Relationship between Contrast Ratio of Conductive Particle and Contact Resistance on COG Bonding using ACF)

  • 진송완;정영훈;최은수;김보선;윤원수
    • 한국정밀공학회지
    • /
    • 제31권9호
    • /
    • pp.831-838
    • /
    • 2014
  • Chip on glass (COG) bonding using anisotropic conductive film (ACF) is a key technology to assemble a driver IC onto a LCD glass panel. In this paper, an experimental investigation was conducted to investigate the correlation between contact resistance and characteristics of image taken by machine vision based inspection system. The results show that the contact resistance was strongly influenced by the contrast ratio of conductive particle rather than the number of conductive particles. Also, number of conductive particles whose contrast ratio is below 0.75 is crucial for determining the quality of the assembled samples. On the other hand, in the result of high temperature high humidity storage test, the contrast ratio of samples was increased. However, in the case of open-circuit samples after temperature humidity storage test, the number of conductive particles whose contrast ratio is above 0.75 was more than that of the closed-circuit samples.

본딩 구조에 따른 광섬유 자왜변환기의 응답특성 (Magnetostrictive response characteristics of fiber-optic transducers with different bonding configurations)

  • 박무윤;김태균;이경식
    • 한국광학회지
    • /
    • 제7권1호
    • /
    • pp.72-76
    • /
    • 1996
  • Metallic glass 1605SC, 2826MB 두 재질에 대해 세 가지 본딩 구조를 가지는 광섬유 자왜변환기를 구성하여 구조에 따른 여러가지 자왜응답특성을 측정해 보았다. 측정결과 두 재질 모두에서 양끝 본딩이 경우 가장 좋은 자왜응답특성을 보였다. 2605SC의 경우 양끝 본딩구조를 가진 자왜변환기의 유효자왜상수 $C_{eff}$, saturation magnetostriction .lambda.$_{s}$ , 최소감지자계 $H_{min}$은 각각 1.2*$10^{-5}$O $e^{-2}$ , 7.4*$10^{-4}$ , 1.6*$10^{-7}$ Oe/.root.Hz로 측정되었고, 2826MB재질의 경우 양끝 본딩구조에서의 유효자왜상수 $C_{eff}$, saturation magnetostriction .lambda.$_{s}$ 는 각각 7.6*$10^{-6}$ O $e^{-2}$ , 3.4*$10^{-4}$ 로 측정되었다.되었다.

  • PDF