• 제목/요약/키워드: bond crack

검색결과 232건 처리시간 0.025초

Effect of ages and season temperatures on bi-surface shear behavior of HESUHPC-NSC composite

  • Yang Zhang;Yanping Zhu;Pengfei Ma;Shuilong He;Xudong Shao
    • Advances in concrete construction
    • /
    • 제15권6호
    • /
    • pp.359-376
    • /
    • 2023
  • Ultra-high-performance concrete (UHPC) has become an attractive cast-in-place repairing material for existing engineering structures. The present study aims to investigate age-dependent high-early-strength UHPC (HESUHPC) material properties (i.e., compressive strength, elastic modulus, flexural strength, and tensile strength) as well as interfacial shear properties of HESUHPC-normal strength concrete (NSC) composites cured at different season temperatures (i.e., summer, autumn, and winter). The typical temperatures were kept for at least seven days in different seasons from weather forecasting to guarantee an approximately consistent curing and testing condition (i.e., temperature and relative humidity) for specimens at different ages. The HESUHPC material properties are tested through standardized testing methods, and the interfacial bond performance is tested through a bi-surface shear testing method. The test results quantify the positive development of HESUHPC material properties at the early age, and the increasing amplitude decreases from summer to winter. Three-day mechanical properties in winter (with the lowest curing temperature) still gain more than 60% of the 28-day mechanical properties, and the impact of season temperatures becomes small at the later age. The HESUHPC shrinkage mainly occurs at the early age, and the final shrinkage value is not significant. The HESUHPC-NSC interface exhibits sound shear performance, the interface in most specimens does not fail, and most interfacial shear strengths are higher than the NSC-NSC composite. The HESUHPC-NSC composites at the shear failure do not exhibit a large relative slip and present a significant brittleness at the failure. The typical failures are characterized by thin-layer NSC debonding near the interface, and NSC pure shear failure. Two load-slip development patterns, and two types of main crack location are identified for the HESUHPC-NSC composites tested in different ages and seasons. In addition, shear capacity of the HESUHPC-NSC composite develops rapidly at the early age, and the increasing amplitude decreases as the season temperature decreases. This study will promote the HESUHPC application in practical engineering as a cast-in-place repairing material subjected to different natural environments.

복합재료-탄소강 접착제 결합 조인트의 하중지지 능력 예측을 위한 이종 재료 접합 계면의 파괴 역학적 분석 (Fracture Mechanical Characterization of Bi-material Interface for the Prediction of Load Bearing Capacity of Composite-Steel Bonded Joints)

  • 김원석;신금철;이정주
    • Composites Research
    • /
    • 제19권4호
    • /
    • pp.15-22
    • /
    • 2006
  • 구조물 설계에 복합재료-금속 접착제 결합 조인트의 개발 및 사용을 제한하는 가장 큰 요인은 접착 조인트의 하중지지 능력 예측을 위한 접착 계면의 강도 평가 방법의 부재이다. 본 연구에서는 복합재료-탄소강의 접착 강도를 계면 모서리에서의 응력강도계수와 파괴 인성 값으로 평가하였다. 구체적으로 동시 경화 성형법으로 제작된 복합재료-탄소강 양면 겹치기 접착조인트의 하중지지 능력을 파괴 역학적 분석 방법을 통하여 결정하였다. 이종재료 계면 모서리 첨단의 응력 특이성과 그 지수를 제시하고 최종적으로 응력강도계수와 실험을 통한 계면의 파괴인성 값을 획득하였다. 서로 다른 접합 길이를 갖는 조인트의 하중지지 능력 비교를 통하여 양면 겹치기 접착 조인트의 파괴 인성치와 혼합 모드에서의 균열 진전 기준을 $K_1-K_{11}$ 평면 내에 도시하였다.

GFRP 보강근으로 보강된 교량 바닥판의 성능과 사용성에 관한 실험연구 (Service and Ultimate Load Behavior of Bridge Deck Reinforced with GFRP Rebars)

  • 유영준;박영환;박지선
    • 대한토목학회논문집
    • /
    • 제28권5A호
    • /
    • pp.719-727
    • /
    • 2008
  • GFRP 보강근의 인장강도 및 부착성능 등은 철근과 다르기 때문에 GFRP 보강근을 콘크리트 구조물에 적용하기 위해서는 GFRP 보강근으로 보강된 콘크리트 부재의 거동에 관한 연구가 선행되어야 한다. GFRP는 높은 비강도, 경량성, 비부식성 등의 장점을 가지고 있으나 탄성계수가 철근보다 작아 상대적으로 큰 처짐이 발생하는 단점이 있다. 교량 바닥판은 아칭효과 등에 의해 휨성능이 증가하므로 FRP 보강근을 우선 적용할 수 있는 대상 중 하나이다. 본 논문은 국내에서 개발된 철근 대체재용 GFRP 보강근의 콘크리트 구조물로의 적용 가능성을 관찰하기 위한 실험연구에 관한 것이다. 대상 실험체는 폭과 길이가 3,000 mm, 4,000 mm이고 두께가 240 mm인 실제 크기의 콘크리트 바닥판이다. 실험변수는 보강근 종류(철근, GFRP 보강근)와 보강비로 총 3개의 바닥판을 제작하였다. 정적실험을 수행하였으며 DB-24 하중등급의 축하중을 모사한 재하면적을 가진 직사각형 강재로 바닥판이 파괴될 때까지 집중하중을 가하였다. 철근 보강 바닥판과 GFRP 보강 바닥판의 거동차이를 최대성능, 처짐 및 균열 거동 등에 대해 비교 검토하였다.

열차폐 코팅층의 고온 열충격 시험후 ECT를 이용한 결함 평가 (Evaluation of Defects of Thermal Barrier Coatings by Thermal Shock Test Using Eddy Current Testing)

  • 허태훈;조윤호;이준현;오정석;이구현
    • 비파괴검사학회지
    • /
    • 제29권5호
    • /
    • pp.450-457
    • /
    • 2009
  • 열차폐 코팅 시편에 대하여 열충격을 주기적으로 가한 후 발생하는 결함을 관찰하였다. 실험에 사용 된 열차폐 코팅 시편은 인코넬-738로 제작된 모재 위에 CoNiCrAlY 본드 코팅층과 $ZrO_2-8wt%Y_2O_3$ 세라믹탑 코팅층이 플라즈마 용사 방법으로 올려진 형태로 되어있다. 열충격 시험은 $1000^{\circ}C$의 고온으로 가열했다가 상온으로 급격하게 냉각시키는 가혹한 조건으로 실행되었고, 사이클 수가 증가함에 따라 열충격의 피로도 또한 증가하였다. 시험후 시편 내부의 미세 조직 변화와 결함을 전자현미경으로 관찰하고, 시편의 기계적인 특성을 측정하여 그 변화 양상을 살펴보았다. 열충격 주기실험후 본드 코팅층과 세라믹 탑 코팅층 사이에 발생하는 TGO 산화물층에 대한 변화 양상과 이에 대한 와전류 신호를 측정하여 TGO층 성장 거동의 비파괴적인 평가를 위한 실험을 진행하였다. 본 연구를 통하여 마이크로 단위의 TGO층에 대한 와전류검사의 적용 가능성을 확인하고 열차폐 코팅의 수명을 예측할 수 있는 가능성을 제시하였다.

강우에 따른 콘크리트 덧씌우기 보수체의 손상에 관한 연구 (Damage of Overlaid Concrete Structures Subjected In Thermally Transient Condition by Rainfall)

  • 윤우현
    • 콘크리트학회논문집
    • /
    • 제13권5호
    • /
    • pp.491-498
    • /
    • 2001
  • 본 연구에서는 강우와 같은 열 충격으로 보수체의 손상(표면 균열, 경계면 파괴)을 유발하는 표면 인장 응력과 기층과 보수층 경계면의 연직 인장 응력 및 진단 응력이 해석적으로 조사되었다. 응력 계산 시에는 사용 재료의 비선형 응력-변형률 곡선이 사용되었고, 특히 변형률 경화, 변형률 연화 특성이 고려되었다. 응력 계산은 보수층의 두께와 보수 재료를 변수로 하여 강우 강도별로 조사되었다. 강우 초기의 보수체의 온도는 하절기에 55$^{\circ}C$까지 가열됐다고 가정하였고, 강우 온도는 1$0^{\circ}C$로 결정하였다. 강우 빈도 1년 1회, 강우 지속 시간 10분, 60분의 강우 하중으로 응력을 계산한 결과, 보수체 표면에서는 실제 균열은 발생치 않고, 단지 변형률 연화 단계의 가상 균열만 형성되었다. 한편 경계면에서는 부착 전단 파괴는 발생치 않았으며, 연직 인장 파괴를 유발하는 음력이 일정한 강우 강도 및 보수 재료에서 보수층의 두께(do)가 클수록 증가하는 것으로 나타나, 경계면의 연직 인장 응력이 보수체의 안전성에 주요한 변수임을 알 수 있었다. 따라서 강우시 경계면의 파괴 예방을 위해 보수 재료의 성질 및 보수층의 두께를 결정할 수 있는 연직 인장 음력의 예측식을 제안하였다.

기계적 합성이 적용된 FRP-콘크리트 합성 바닥판의 거동 분석 (Behavior of FRP-Concrete Composite Decks with the Mechanical Connection)

  • 김성태;박성용;조정래;김병석;조근희
    • 콘크리트학회논문집
    • /
    • 제22권5호
    • /
    • pp.609-616
    • /
    • 2010
  • FRP-콘크리트 합성 바닥판은 압축에 강한 콘크리트를 상부에 위치시키고 인장에 강한 FRP를 하부에 위치시켜, FRP와 콘크리트가 갖는 장점을 극대화시킴으로서 내구성, 안전성 등을 두루 향상시킨 새로운 개념의 구조이다. 그러나 서로 다른 재질의 두 재료를 합성시키기 위한 방안으로서 연구 초기에 적용된 규사코팅 공법 외에 수직부착력을 향상시킬 수 있는 기계적 합성 방안을 고안하였다. 이렇게 고안한 합성 방안이 적용된 실제 사이즈의 바닥판 실험체를 제작하여 정적 및 피로반복실험을 수행하였다. 정적실험 결과 이 연구에서 제안한 합성 방안이 적용된 바닥판이 처짐 및 균열 등에 대해서 설계기준을 충분히 만족시켜 매우 우수한 성능을 나타내고 있었으며, 피로실험 결과 파괴하중의 50%로 200만회 가력한 후에도 처짐 및 균열 등에 대해 설계기준을 만족하고 있어 충분한 피로내구성을 확보하고 있는 것으로 나타났다. 이에 이 연구에서 제시한 규사코팅과 기계적 합성 방안을 동시에 적용한 합성 방안은 FRP-콘크리트 합성 바닥판에 대해 충분한 적용성을 갖고 있으며, FRP-콘크리트 합성 바닥판 설계시 제시한 설계조건들이 적절하게 이용될 수 있음을 확인하였다.

접착식 콘크리트 덧씌우기를 위한 초속경화 첨가재 현장 혼합 폴리머 개질 콘크리트의 적용성 연구 (Application of In-Situ Mixing Hydration Accelerator on Polymer Modified Concrete for Bonded Concrete Overlay)

  • 김영규;홍성재;이승우
    • 한국도로학회논문집
    • /
    • 제17권3호
    • /
    • pp.85-95
    • /
    • 2015
  • PURPOSES : Recently, bonded concrete overlay has been used as an alternative solution in concrete pavement rehabilitation since its material properties are similar to those of the existing concrete pavements. Deteriorated concrete pavements need rapid rehabilitation in order to prevent traffic jams on Korean expressways. Moreover, speedy and effective repair methods are required. Therefore, the use of bonded concrete overlay with ultra-rapid hardening cement has increased in an effort to reopen promptly the expressways in Korea. However, mobile mixer is required for ultra-rapid hardening cement concrete mixing in the construction site. The use of mobile mixer causes various disadvantages aforementioned such as limitation of the construction supply, open-air storage of mixing materials, increase in construction cost, and etc. In this study, therefore, hydration accelerator in-situ mixing on polymer modified concrete produced in concrete plant is attempted in order to avoid the disadvantages of existing bonded concrete overlay method using ultra-rapid hardening cement. METHODS : Bonded concrete overlay materials using ultra-rapid hardening cement should be meet all the requirements including structural characteristics, compatibility, durability for field application. Therefore, This study aimed to evaluate the application of hydration accelerator in-situ mixing on polymer modified concrete by evaluating structural characteristics, compatibility, durability and economic efficiency for bonded concrete overlay. RESULTS : Test results of structural characteristics showed that the compressive, flexural strength and bond strength were exceed 21MPa, 3.15MPa and 1.4MPa, respectively, which are the target strengths of four hours age for the purpose of prompt traffic reopening. In addition, tests of compatibility, such as drying shrinkage, coefficient of thermal expansion and modulus of elasticity, and durability (chloride ions penetration resistance, freezing-thawing resistance, scaling resistance, abrasion resistance and crack resistance), showed that the hydration accelerator in-situ mixing on polymer modified concrete were satisfied the required criteria. CONCLUSIONS : It was known that the hydration accelerator in-situ mixing on polymer modified concrete overlay method was applicable for bonded concrete overlay and was a good alternative method to substitute the existing bonded concrete overlay method since structural characteristics, compatibility, durability were satisfied the criteria and its economic efficiency was excellent compare to the existing bonded concrete overlay methods.

섬유혼입조건 및 팽창재 대체에 따른 변형 경화형 시멘트 복합체 내의 철근 겹침이음 성능 (Effects of Fiber Blending Condition and Expansive Admixture Replacement on Tensile Performance of Rebar Lap Splice in Strain-Hardening Cement-Based Composites (SHCCs))

  • 류승현;이영오;윤현도
    • 콘크리트학회논문집
    • /
    • 제24권2호
    • /
    • pp.111-120
    • /
    • 2012
  • 이 연구는 섬유 보강 시멘트 복합체(SHCC) 내에 매립된 철근의 겹침이음 성능을 평가하고자 하였으며, 이에 따라 단조 및 반복 재하시의 겹침이음된 철근의 인장 실험을 실시하였다. 총 10개의 SHCC 및 콘크리트 배합이 계획되었으며, 실험체의 변수는 보강섬유 종류(폴리에틸렌 및 강섬유), 팽창재 대체율(0% 및 10%) 및 실험체의 설계강도(30 MPa 및 100 MPa)로 계획하였다. SHCC 및 콘크리트 배합에 매립된 철근의 겹침이음 길이는 각각 콘크리트 구조설계 기준에 의거하여 산정된 겹침이음 길이의 60% 및 100%를 적용하였다. 실험 결과 SHCC에 철근이 매립될 경우 철근의 겹침이 음 성능을 향상시키는 것으로 나타났으며, SHCC 배합에서 보강 섬유 종류(PE-SHCC 및 PESF-SHCC)에 관계없이 겹침 이음된 철근의 인장강도 및 부착강도 증진에 기여하는 것으로 나타났다. 또한 SHCC에 팽창재를 대체할 경우 SHCC에 매립된 철근 겹침이음부의 거동 특성을 개선하는 특징을 보였다. 한편 균열 특성에서는 배합조건 및 재료특성에 따라 PE-SHCC가 PESF-SHCC에 비해 보다 많은 미세균열 특성을 나타내었다. 전언한 바와 같이 이 연구는 SHCC의 변형경화 특성에 따라 매립된 철근과의 상호작용을 증진시킴에 따라, SHCC에 매립된 철근 겹침이음 길이를 감소할 경우에도 양호한 거동 특성을 보이는 것으로 판단된다.

초속경 라텍스개질콘크리트로 덧씌우기 및 보수된 철근콘크리트보의 보강효과 (Strengthen Effect of RC Beam Overlaid or Repaired by VES-LMC)

  • 최성용;윤경구;최승식
    • 콘크리트학회논문집
    • /
    • 제20권4호
    • /
    • pp.423-430
    • /
    • 2008
  • 최근 들어 고속도로를 중심으로 하여 교량상판 보수재료로 초속경 라텍스개질콘크리트 (Very-Early Strength Latex-Modified Concrete : 이하 VES-LMC)가 개발되어 이용되고 있고, 그 활용 빈도가 커지고 있다. 이는 VES-LMC의 특징상 보수 후 3시간 만에 교통개방이 가능하며, 라텍스 첨가로 기존의 보수재료가 갖는 장기 내구성의 문제를 해결하였기 때문이다. 그러나 위와 같은 장점으로 보수 보강 재료로 사용되고 있는 VES-LMC에 대한 구조적인 연구에 대해서는 미비한 상태이다. 본 연구에서는 VES-LMC를 기존보의 덧씌우기 형태와 열화된 콘크리트의 보수 형태로 나누어 시험체를 제작하고, 4점 휨 실험을 수행하여 휨 거동 및 신 구 콘크리트의 부착 특성과 균열 진전 양상, 보수 보강효과를 확인하고자 하였다. 그 결과 보수 보강두께가 증가함에 따라 보수 보강효과가 증가하는 경향을 보였으며 이는 강성이 증가하여 휨에 대한 저항 능력이 증대되는 것을 확인하였다. 보수 시험체의 경우 철근의 피복두께 이상으로 보수 되었을 경우 강성이 최대 40% 이상 증가 되는 결과는 얻을 수 있었으나 80 mm와 120 mm의 경우 그 값이 비슷한 양상을 보여 보강 두께 선정 시 고려되어야 할 요소라 판단된다. 계면거동을 확인한 결과 보수 및 보강 시험체 모두 계면에서의 상대 변위량이 감소되는 것을 확인하였으며, 두 재료가 비교적 일체로 거동하는 것을 확인하였다.

Solid Epoxy를 이용한 패키지 및 솔더 크랙 신뢰성 확보를 위한 실험 및 수치해석 연구 (Experimental and Numerical Analysis of Package and Solder Ball Crack Reliability using Solid Epoxy Material)

  • 조영민;좌성훈
    • 마이크로전자및패키징학회지
    • /
    • 제27권1호
    • /
    • pp.55-65
    • /
    • 2020
  • 반도체 패키지에서 언더필의 사용은 패키지의 응력 완화 및 습기 방지에 중요할 뿐만 아니라, 충격, 진동 시에 패키지의 신뢰성을 향상시키는 중요한 소재이다. 그러나 최근 패키지의 크기가 커지고, 매우 얇아짐에 따라서 언더필의 사용이 오히려 패키지의 신뢰성을 저하하는 현상이 발견되고 있다. 이러한 이슈를 해결하기 위하여 본 연구에서는 언더필을 대신 할 소재로서 solid epoxy를 이용한 패키지를 개발하여 신뢰성을 향상시키고자 하였다. 개발된 solid epoxy를 스마트 폰의 AP 패키지에 적용하여 열사이클링 신뢰성 시험과 수치해석을 통하여 패키지의 신뢰성을 평가하였다. 신뢰성 향상을 위한 최적의 solid epoxy 소재 및 공정 조건을 찾기 위하여 solid epoxy 의 사용 개수, PCB 패드 타입 및 solid epoxy의 물성 등, 3 개의 인자가 패키지의 신뢰성에 미치는 영향을 고찰하였다. Solid epoxy를 AP 패키지에 적용한 결과 solid epoxy가 없는 경우 보다, solid epoxy를 적용한 경우가 신뢰성이 향상되었다. 또한 solid epoxy를 패키지의 외곽 4곳에 적용한 경우 보다는 6 곳에 적용한 경우가 더 신뢰성이 좋음을 알 수 있었다. 이는 solid epoxy가 패키지의 열팽창에 따른 응력을 완화 시키는 역할을 하여 패키지의 신뢰성이 향상되었음을 의미한다. 또한 PCB 패드 타입에 대한 신뢰성을 평가한 결과 NSMD (non-solder mask defined) 패드를 사용할 경우가 SMD (solder mask defined) 패드 보다 신뢰성이 더 향상됨을 알 수 있었다. NSMD 패드의 경우 솔더와 패드가 접합하는 면적이 더 크기 때문에 구조적으로 안정하여 신뢰성 측면에서 더 유리하기 때문이다. 또한 열팽창계수가 다른 solid epoxy를 적용하여 신뢰성 평가를 한 결과, 열팽창계수가 낮은 solid epoxy를 사용한 경우가 신뢰성이 더 향상됨을 알 수 있었다.