• Title/Summary/Keyword: body image

Search Result 2,310, Processing Time 0.032 seconds

The Comparison of Image Quality and Quantitative Indices by Wide Beam Reconstruction Method and Filtered Back Projection Method in Tl-201 Myocardial Perfusion SPECT (Tl-201 심근관류 SPECT 검사에서 광대역 재구성(Wide Beam Reconstruction: WBR) 방법과 여과 후 역투영법에 따른 영상의 질 및 정량적 지표 값 비교)

  • Yoon, Soon-Sang;Nam, Ki-Pyo;Shim, Dong-Oh;Kim, Dong-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.122-127
    • /
    • 2010
  • Purpose: The Xpress3.$cardiac^{TM}$ which is a kind of wide beam reconstruction (WBR) method developed by UltraSPECT (Haifa, Israel) enables the acquisition of at quarter time while maintaining image quality. The purpose of this study is to investigate the usefulness of WBR method for decreasing scan times and to compare to it with filtered back projection (FBP), which is the method routinely used. Materials and Methods: Phantom and clinical studies were performed. The anthropomorphic torso phantom was made on an equality with counts from patient's body. The Tl-201 concentrations in the compartments were 74 kBq (2 ${\mu}Ci$)/cc in myocardium, 11.1 kBq (0.3 ${\mu}Ci$)/cc in soft tissue, and 2.59 kBq (0.07 ${\mu}Ci$)/cc in lung. The non-gated Tl-201 myocardial perfusion SPECT data were acquired with the phantom. The former study was scanned for 50 seconds per frame with FBP method, and the latter study was acquired for 13 seconds per frame with WBR method. Using the Xeleris ver. 2.0551, full width at half maximum (FWHM) and average image contrast were compared. In clinical studies, we analyzed the 30 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Medical Center from January to April 2010. The patients were imaged at full time (50 second per frame) with FBP algorithm and again quarter-time (13 second per frame) with the WBR algorithm. Using the 4D MSPECT (4DM), Quantitative Perfusion SPECT (QPS), and Quantitative Gated SPECT (QGS) software, the summed stress score (SSS), summed rest score (SRS), summed difference score, end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were analyzed for their correlations and statistical comparison by paired t-test. Results: As a result of the phantom study, the WBR method improved FWHM more than about 30% compared with FBP method (WBR data 5.47 mm, FBP data 7.07 mm). And the WBR method's average image contrast was also higher than FBP method's. However, in result of quantitative indices, SSS, SDS, SRS, EDV, ESV, EF, there were statistically significant differences from WBR and FBP(p<0.01). In the correlation of SSS, SDS, SRS, there were significant differences for WBR and FBP (0.18, 0.34, 0.08). But EDV, ESV, EF showed good correlation with WBR and FBP (0.88, 0.89, 0.71). Conclusion: From phantom study results, we confirmed that the WBR method reduces an acquisition time while improving an image quality compared with FBP method. However, we should consider significant differences in quantitative indices. And it needs to take an evaluation test to apply clinical study to find a cause of differences out between phantom and clinical results.

  • PDF

Evaluation of Standardized Uptake Value applying EQ PET across different PET/CT scanners and reconstruction (PET/CT 장비와 영상 재구성 차이에 따른 EQ PET을 이용한 표준섭취계수의 평가)

  • Yoon, Seok Hwan;Kim, Byung Jin;Moon, Il Sang;Lee, Hong Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.35-42
    • /
    • 2018
  • Purpose Standardized uptake value(SUV) has been widely used as a quantitative metric of uptake in PET/CT for diagnosis of malignant tumors and evaluation of tumor therapy response. However, the SUV depends on various factor including PET/CT scanner specifications and reconstruction parameter. The purpose of this study is to validate a EQ PET to evaluate SUV across different PET/CT systems. Materials and Methods First, NEMA IEC body phantom data were used to calculate the EQ filter for OSEM3D with PSF and TOF reconstruction from three different PET/CT systems in order to obtain EARL compliant recovery coefficients of each spheres. The Biograph true point 40 PET/CT images were reconstructed with a OSEM3D+PSF reconstruction, images of the Biograph mCT 40 and Biograph mCT 64 PET/CT scanners were reconstructed with a OSEM3D+PSF, OSEM3D+TOF, OSEM3D+PSF+TOF. Post reconstructions, the proprietary EQ filter was applied to the reconstruction data. Recovery coefficient can be estimated by ratio of measured to true activity concentration for spheres of different volume and coefficient variability(CV) value of RC for each sphere was compared. For clinical study, we compared SUVmax applying different reconstruction algorithms in FDG PET images of 61 patients with lung cancer using Biograph mCT 40 PET/CT scanner. Results For the phantom studied, the mean values of CV for OSEM3D, OSEM3D+PSF, OSEM3D+TOF and OSEM3D+PSF+TOF reconstructions were 0.05, 0.04, 0.04 and 0.03 respectively for RC. Application of the proprietary EQ filter, the mean values of CV for OSEM3D, OSEM3D+PSF, OSEM3D+TOF and OSEM3D+PSF+TOF reconstructions were 0.04, 0.03, 0.03 and 0.02 respectively for RC. Clinical study, there were no statistical significance of the difference applying EQ PET on SUVmax of 61 patients FDG PET image. (p=1.000) Conclusion This study indicates that CV values of RC in phantom were decreased after applying EQ PET for different PET/CT system and The EQ PET reduced reconstruction dependent variation in SUVs for 61 lung cancer patients, Therefore, EQ PET will be expected to provide accurate quantification when the patient is scanned on different PET/CT system.

The Usefulness of F-18-FDG PET and The Effect of Scan Protocol in Diagnosis of Intraocular Tumors (안구 내 종양의 진단에 있어서 F-18-FDG PET의 유용성과 검사 방법의 영향)

  • Lee, Jae-Soung;Yang, Won-Il;Kim, Byoung-Il;Choi, Chang-Woon;Lim, Sang-Moo;Lee, Tae-Won;Sin, Min-Kyeung;Hong, Soung-Woon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.5
    • /
    • pp.439-451
    • /
    • 1999
  • Purpose : It is important to differentiate malignant from benign lesions of intraocular masses in choosing therapeutic plan. Biopsy of intraocular tumor is not recommended due to the risk of visual damage. We evaluated the usefulness of F-18-FDG PET imaging in diagnosing intraocular neoplasms. Materials and Methods: F-18-FDG PET scan was performed in 13 patients (15 lesions) suspected to have malignant intraocular tumors. There were 3 benign lesions (retinal detachment, choroidal effusion and hemorrhage) and 10 patients with 12 malignant lesions (3 melanomas, 7 retinoblastomas and 2 metastatic cancers). Regional eye images ($256{\times}256$ and $128{\times}128$ matrices) were obtained with or without attenuation correction. Whole body scan was also performed in eight patients (3 benign and 6 malignant lesions). Results: All malignant lesions were visualized while all benign lesions were not visualized. The mean peak standardized uptake value (SUV) of malignant lesions was $2.64{\pm}0.57g/ml$. There was no correlations between peak SUV and tumor volume. Two large malignant lesions ($> 1000 mm^3$) showed hot uptake on whole body scan. But two medium-sized lesions ($100-1000mm^3$) looked faint and two small ($<100mm^3$) lesions were not visualized. The images reconstructed with $256{\times}256$ matrix showed lesions more clearly than those with $128{\times}128$ matrix Conclusion: F-18-FDG PET scan is highly sensitivity in detecting malignant intraocular tumor For the evaluation of small-sized intraocular lesions, whole body scan is not appropriate because of low sensitivity. A regional scan with sufficient acquisition time is recommended for that purpose. Image reconstruction in matrix size of $256{\times}256$ produced clearer images than the ones in $128{\times}128$, but it does not affect the diagnostic sensitivity.

  • PDF

A Study on the Efficiency of Hand-Knee Position in GB Stone Ultrasonography (담낭결석 초음파검사에서 Hand-Knee position의 효율성에 관한 연구)

  • Park, Soung-Ock;Do, Yun-Su
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.267-274
    • /
    • 2006
  • The evaluation of GB stones with ultrasound has proved to be useful procedure in patient with symptoms of cholelithiasis. GB is evaluated for size, wall thickness, presence of internal reflections within the lumen and posterior acoustic shadowing or enhancement in Ultrsonography. The patient position should be shifted during procedure to demonstrate further the presence of stone within the GB. Patient scanned at the Rt. subcostal region in supine, right lateral, Lt. down decubitus, and upright sitting position. So GB stone should shift to dependent area of GB. Often, GB is not markedly distended in the presence of cholethiasis, and so the diagnosis becomes more difficult. One of the more difficult areas for detection of a GB stones are embeded in the cystic duct region. And since the GB is adjacent to the duodenum and hepatic flexure, its may be difficult to visualizing a GB stone. When patient study position changes frome supine to other position, stones displaced the site. But if its are polyps, not changes the site whatever patient positions. It is very important to what make different GB stones or polyps. We have studied about mobility of GB stones according to the patients position(supine, Lt. down decubitus, $30^{\circ} LAO. sitting and hand-knee). So we have a result, stones wherever localized within the GB, changed 100% its position in the hand-knee position and the others appeared at least 90%. In this study, when a large stones are located through fundus-body and body-neck, does not changing the stones position in spite of varied patient's positions. But hand-knee positions can identified GB stones, because its make changed the position of stons from posterior wall to anterior wall within the GB. We recommend the hand-knee position for differentiation GB stones from polyps.

  • PDF

The Usefulness of F-18 FDG Whole Body PET in the Evaluation of Postoperative Recurrence of Cancer (수술 후 암 재발 판정에 있어서 전신 F-18 FDG-PET의 유용성)

  • Kang, Won-Jun;So, Young;Jeong, Jae-Min;Kwark, Cheol-Eun;Lee, Dong-Soo;Kang, Soon-Bem;Jung, Hee-Won;Kim, Kwang-Hyun;Park, Jae-Gahb;Lee, Myung-Chul;Koh, Chang-Soon;Chung, June-Key
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.372-380
    • /
    • 1997
  • The purpose of this study was to evaluate the usefulness of whole body F-18 FDG PET scan for detecting postoperative recurrence of cancer. One hundred four cancer patients after operation were enrolled(14 brain tumor, 15 head and neck cancer, 23 gynecologic cancer, 16 gastrointestinal cancer, 16 thyroid cancer, and 20 other cancers). Besides conventional images(CI) including CT and MRI, F-18 FDG PET scan was obtained on ECAT EXACT 47 scanner(Siemens-CTI), beginning 60 minutes after injection of 370MBq(10mCi) of F-18 FDG. Regional scan was also obtained with emission image. Transmission images using Ge-68 were carried out for attenuation correction in both whole body and regional images. Findings of PET, and CI were confirmed by pathology or clinical follow up. The sensitivity and specificity of PET for detecting recurrence were 94% and 92%, respectively. Contrarily, the sensitivity and specificity of CI were 78% and 68%. CI results were negative and PET results were positive in 11 cases. The biopsy or clinical follow-up of those cases confirmed recurrence of tumor. False negative cases of CI were frequent in patients with gynecologic cancers. Also we measured the serum concentration of tumor markers in patients with gynecologic cancer(CA125), thyroid cancer(thyroglobulin), and colorectal cancer(CEA). The sensitivity and specificity of tumor markers were 71% and 84%, respectively, We conclude that F-18 FDG PET can be used valuably in detecting recurrent foci of a wide variety of malignancy compared to conventional diagnostic methods.

  • PDF

A Kinematical Analysis of Belle Motion on Parallel Bars (평행봉 Belle 기술동작의 운동학적 분석)

  • Kong, Tae-Ung
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.4
    • /
    • pp.43-53
    • /
    • 2005
  • This study is to define how the difference of athletic change influence on the last regrasp after somersault in Belle movement of parallel bars. For his study, the following conclusion was produced by analysis of athletic change by means of three dimensional visual image in three athlete of nation. 1. As the picture of S1, there are total used time(2.01 sec), S3(2.17 sec) and S2(2.19 sec). In case of a short needed time, it is difficult for them to perform the remaining movement of the vertical elevating flight easily and comfortably, it is judged as performing the small movement with restrict swing. 2 In the change of body center sped by each event, it is calculated as $-89.1^{\circ}$ the narrowest in S1, $-81.96^{\circ}$ the widest and then $86.34^{\circ}$ in S3. In E3 event, average compound speed is 4.07m/s, S2 showed the fastest speed of 4.14m/s whereas S1 the narrowest angle of 3.95m/s. 3. A shoulder joint and coxa are the period of mention in E3. In E4 which was pointed out the longest vertical distance, S2 that is indicated the highest vertical height as the period of detach in parallel bars. showed -3.91m. This is regarded as a preparatory movement for dynamic performance after using effectively elastic movement of shoulder joint and coxa while easily going up with turning back movement. In the 5th phrase, long airborne time and vertical change position is showed as the start while regrasping securely air flight movement from high position. 4. In E5, a long flight time and a long vertical displacement were shown as the regrasp after somersault efficiently in high position with stability from the point of the highest peak of the center of the body. Especially, S2 is marked as a little bit long position, while S1 is reversely indicated as performing somersault and unstable motion in a low position. 5. In E3, at the point of the largest extension of the shoulder joint and hip joint the shoulder joint is largely marked in $182^{\circ}$ and the hip point $182^{\circ}$ in S2. The shoulder joint is marked at the smallest angle in $177^{\circ}$ and the hip point $176^{\circ}$ in S1. And S1 is being judged by its performance of the less self - confident motion with lessening a breath of swing. S2 makes the most use of flexion and extension of the shoulder joint and the hip joint effectively. It was performed greatly with swinging and dropping the rotary movement and the rotary inertia naturally. 6. In E6, as the point of regrasp of the upper arm in parallel bars it is recognized by the that of components of vertical and horizontal velocity stably. During this study, the insufficient thing and the study on the parallel bars at a real game later are more activated than now. If it is really used as the basic materials by means of Belle Picked Study of Super E level after Bell movement, you may perceive the technique movement previously and perform without difficulty. Especially, such technique as crucifix is quite advantageous for oriental people thanks to small body shape condition. In conclusion we will nicely prepare for our suitable environment to gradually lessen trials and errors by analyzing and studying kinematically this movement.

THE EFFECT OF LOW DIETARY CALCIUM AND IRRADIATION ON MANDIBLE IN RATS (저칼슘식이와 방사선조사가 백서 악골에 미치는 영향의 실험적 연구)

  • Lee Sun-Ki;Lee Sang-Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.23 no.2
    • /
    • pp.229-250
    • /
    • 1993
  • This study was performed to investigate the morphological and structural changes of bone tissues and the effects of irradiation on the mandibular bodies of rats which were fed low calcium diets. In order to carry out this experiment, 160 seven-week old Sprague-Dawley strain rats weighing about 150 gm were selected and equally divided into one normal diet group of 80 rats and one low calcium diet group with the remainder. These groups were then subdivided into two groups, 40 were assigned rats for each subdivided group, exposed to radiation. The Group 1 was composed of forty non-irradiated rats with normal diet, Group 2 of forty irradiated rats with normal diet, Group 3 forty non-irradiated rats with low calcium diet, and Group 4 forty irradiated rats with low calcium diet. The two irradiation groups received a single dose of 20 Gy on the jaw area only and irradiated with a cobalt-50 teletherapy unit. The rats with normal and low calcium diet groups were serially terminated by ten on the 3rd, the 7th, the 14th, and the 21st day after irradiation. After termination, both sides of the dead rats mandible were removed and fixed with 10% neutral formalin. The bone density of mandibular body was measured by use of bone mineral densitometer(Model DPX -alpha, Lunar Corp., U.SA). Triga Mark ill nuclear reactor in Korea Atomic Research Institute was used for neutron activation and then calcium contents of mandibular body were measured by using a 4096 multichannel analyzer (EG and G ORTEC 919 MCA, U.SA). Also the mandibular body was radiographed with a soft X-ray apparatus(Hitex Co., Ltd., Japan). Thereafter, the obtained microradiograms were observed by a light microscope and were used for the morphometric analysis using a image analyzer(Leco 2001 System, Leco Co., Canada). The morphometric analysis was performed for parameters such as the total area, the bone area, the inner and outer perimeters of the bone. The obtained results were as follows: 1. In the morphometric analysis, total area and outer perimeter of the mandibular bodies of Group 3 were a little smaller than that of Group 1. The mean bone width and bone area were much smaller than that of Group 1 and the inner perimeter of Group 3 was much longer than that of Group 1. The total area and outer perimeter of Group 2 and Group 4 showed little difference. The mean bone width and bone area of Group 4 were smaller than that of Group 2 and the inner perimeter of Group 4 was longer than that of Group 2. 2. The remarkable decreases of the number and thickness of trabeculae and also the resorption of endosteal surface of cortical bone could be seen in the microradiogram of Group 3, Group 4 since the 3rd day of experiment. On the 21st day of experiment, the above findings could be more clearly seen in Group 4 than in Group 3. 3. The bone mineral density of Group 3 was lesser than that of Group 1 and the bone mineral density of Group 4 was lesser than that of Group 2 on the 7th, 14th, 21st days. The irradiation caused the bone mineral density to be decreased regardless of diet. In the case of Groups with low calcium diet, the bone mineral density was much decreased on the 21st day than on the 3rd day of experiment. 4. The calcium content in mandible of Group 3 was smaller than that of Group 1 throughout the experiment. roup 4 showed the least amount of calcium content. The irradiation caused the calcium content to be decreased regardless of diet. In the case of Groups with low calcium diet, the calcium content was much decreased on the 21st day than on the 3rd day of experiment. In conclusion, the present study demonstrated that morphological changs and decrease of bone mass due to resorption of bone by low calcium diet, and that the resorption of bone could be found in the spongeous bone and endosteal surface of cortical bone. So the problem of resorption of bone must be considered when the old and the postmenopausal women are taken radiotherapy because the irradiation seems to be accelerated the resorption of osteoporotic bone.

  • PDF

A Comparative Study of the Theories of Life Posited by Confucianism and Daesoon Thought (유학과 대순사상의 생명론 비교 고찰)

  • An Yoo-kyoung
    • Journal of the Daesoon Academy of Sciences
    • /
    • v.42
    • /
    • pp.75-108
    • /
    • 2022
  • This paper aims to newly investigate the meaning of life in this era when various discussions on life and ethical living are commonly raised by comparing and examining the theories of life proposed by Confucianism and Daesoon Thought. Both Confucianism and Daesoon Thought explain the creation of all things as having been based on the principles of life in heaven and earth. Specifically, there is the will to live (生意 saengeui) and also divine beings (神明 sinmyeong). For this reason, everything in heaven and earth is created by obtaining the same principle of life such that it is an equal being with the same intrinsic value. Here the consciousness of being one body amid all things as one living thing is established. The consciousness of being one body forms an organic worldview in which all things are one. As a result, all things in heaven and earth exist within a mutual organic relationship, and that makes oneself and others precious life partners that coexist rather than separate beings. Nevertheless, both Confucianism and Daesoon Thought define humans as outstanding beings, set aside for a higher purpose than other beings. The excellence of humans is that by constantly engaging in self reflection and completing tasks through independent efforts, they thereby achieve the great moral doctrine of coexistence and symbiosis. In this process, cultivation of character (修養 suyang) and cultivation of the Dao (修道 sudo) are presented as means to realize one's nature and establish the right human image. By realizing nature or humanity through the cultivation of character and cultivation of the Dao, humans fulfill their responsibilities and missions by independently participating in being nourished by Heaven and Earth (天地化育 cheonjihwayuk) or the Reordering Works of Heaven and Earth (天地公事 cheonjigongsa), both being based in the concept of the three generative forces of Heaven, Earth, and Humanity (天·地·人 cheon·ji·in). In the end, the theories of life posited by Confucianism and Daesoon Thought are based on a consciousness of being one body. Both emphasize the characteristics and roles of humans who are distinguished from other beings and phenomena. At this time, human characteristics and roles are revealed as the reasons for which humans have a responsibility and mission take care of all things. From this point of view, it can be seen that the theoretical structure of Neo-Confucianism and Daesoon Thought, in regards to their theories of life, is rather similar.

Jeonghyesa Temple reconstructed at Yesan by Mangong and the meaning of the creation of the stone standing Avalokiteśvara statue during the Japanese colonial period (일제강점기 만공(滿空)의 예산 정혜사 중창과 석조관음보살입상 조성의 의미)

  • Lee Jumin
    • Korean Journal of Heritage: History & Science
    • /
    • v.56 no.1
    • /
    • pp.22-43
    • /
    • 2023
  • This paper deals with the stone standing Avalokitesvara statue in Jeonghyesa Temple that was created by Mangong in 1924. The stone standing Avalokitesvara statue of Jeonghyesa Temple is the earliest extant Buddha statue produced by Mangong, and symbolism was given to Jeonghyesa in the process of its reconstruction. So far, there has been no study that has approached ideas and beliefs through Buddhist studies led by Mangong and specific relics. In order to proceed with this study, Mangong's legal words and anecdotes and newspaper articles during the Japanese colonial era were used to trace the dynamics of Jeonghyesa and Sudeoksa during Mangong's reign, and to investigate the effects obtained from the creation of the large Bodhisattva statue and the meaning of its location. In addition, an interview was attempted with the descendants of master, who were in charge of the sculpture at the time, to confirm the exact construction period and the list of craftsmen. It is judged that the stone standing Bodhisattva statue of Gwanchoksa Temple has been influenced by the double covering and square crown seen in the standing stone statue of Avalokitesvara Bodhisattva of Jeonghyesa Temple, the large hands compared to the body, the proportion between the head and the body, and the sense of enormity felt in the body like a stone pillar. Therefore, we looked at how the standing stone Bodhisattva statue of Gwanchoksa Temple, which was produced in the early Goryeo Dynasty, could have influenced the creation of the Bodhisattva statue in the modern period. A multilateral analysis was attempted on how the image of the Gwanchoksa Bodhisattva statue, which was used as a symbol representing Chungcheongnam-do in the Chosun Exposition held in 1929 and the visit to Gwanchoksa Temple, which began with the laying of the railroad during the Japanese colonial period, was used from the viewpoint of the succession and transformation of the style. With this study as an opportunity, it is hoped that the understanding of the prehistoric Mangong representing the modern period and the horizon of Korean Buddhist sculpture research in the modern period will be broadened.

Comparison of Exposure Dose by Using AEC Mode of Abdomen AP Study in Radiography (복부 전후 방향 검사의 자동노출제어 사용 시 선량 비교 연구)

  • Kim, Ki-Won;Kwon, Yong-Rak;Seo, Seong-Won;Kwon, Kyung-Tae;Oh, Joo-Young;Son, Soon-Yong;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.205-211
    • /
    • 2015
  • We evaluated the effectiveness of TL (Time Limit) method by comparing with NTL (Non-time limit) method when it is used for examinations for abdomen Anterior Posterior (AP) in this paper. The evaluation was conducted based on the comparison of dose, and of signal to noise ratio (SNR) and contrast to ratio (CNR) on both methods. The experiments were conducted with XGEO GC 80 (Samsung, Korea), Unfors ThinX RAD (Unfors, Sweden) and Rando Phantom (Alderson research laboratories, USA) and shielding material with the size of $5.5{\times}9{\times}0.1cm^3$. It was set to activate only two upper ionization chambers in automatic exposure control(AEC) mode and the tube-voltage was set to 80kVp. When the exposure time was limited, it is limited to 51 msec. The images both by NTL AEC method and TL AEC method were acquired when with and without attachment of shielding material on the upper ionization chambers. The images were evaluated by SNR and CNR which are the image evaluation methods using 'Image J'. The NTL AEC method showed increases in dose as much as 130.7% at maximum and 80% at minimum than other methods. The TL AEC method showed decreases in mAs and exposure dose than the NTL AEC method as much as 43.8% and 44.4% respectively. There were no significant differences in SNR or CNR for the experiments (($p{\geq}0.05$). Therefore, it is suggested that the TLAEC mode is more effective when examining patients who have high BMI index or a patient with a metallic substance in the body after surgery.