• Title/Summary/Keyword: body area device

Search Result 128, Processing Time 0.026 seconds

Rough Terrain Negotiable Mobile Platform with Passively Adaptive Double-Tracks and Its Application to Rescue Missions and EOD Missions

  • Lee, Woo-Sub;Kang, Sung-Chul;Kim, Mun-Sang;Shin, Kyung-Chul
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1048-1053
    • /
    • 2005
  • This paper presents design and integration of the ROBHAZ-DT3, which is a newly developed mobile robot system with chained double-track mechanisms. A passive adaptation mechanism equipped between the front and rear body enables the ROBHAZ-DT3 to have good adaptability to uneven terrains including stairs. The passive adaptation mechanism reduces energy consumption when moving on uneven terrain as well as its simplicity in design and remote control, since no actuator is necessary for adaptation. Based on this novel mobile platform, a rescue version of the ROBHAZ-DT3 with appropriate sensors and a semi-autonomous mapping and localization algorithm is developed to participate in the RoboCup2004 US-Open: Urban Search and Rescue Competition. From the various experiments in the realistic rescue arena, we can verify that the ROBHAZ-DT3 is reliable in traveling rugged terrain and the proposed mapping and localization algorithm are effective in the unstructured environment with uneven ground. The another application is an military robot for an EOD(Explosive Ordnance Disposal) and reconnaissance mission. The military version of the ROBHAZ-DT3 with a water disrupter, a thermal scope and a long distance wireless communication device is developed and sent to the area of military tactics in Iraq. Consequently, the feasibility of the military version of ROBHAZ-DT3 is verified.

  • PDF

A study on smart fashion product development trends (스마트패션제품 개발 동향에 관한 연구)

  • Suh, Sung-Eun;Roh, Jung-Sim
    • The Research Journal of the Costume Culture
    • /
    • v.23 no.6
    • /
    • pp.1097-1115
    • /
    • 2015
  • ICT in the IOT era is the core basis of modern society. This study investigated and analyzed the recent commercialization trends of smart fashion products internationally and domestically, to utilize them as the basis of data for developing user-friendly smart fashion products that can meet the needs of consumers. Keyword research using the most representative search engines, Google and Naver was conducted for searching for various wearable items commercialized actively since 2010. The final 78 products were classified by the physical area, and the key features and benefits were analyzed. Smart fashion products were classified as four physical types for the head and face, torso, arms and hands, and ankles and feet. Smart fashion products for each body part were developed in various ways, such as hats, glasses, lenses, virtual screens, earphones, headsets, clothing, watches, wrist bands, gloves, rings, wallets, bags, anklets, shoes, socks, and insoles. The main features were music playback, bluetooth, a camera based on NFC, virtual effects, health and safety protection through measuring heartbeat and momentum, and social network sharing of all kinds of information, based on inter-working with a smartphone. These functions represent the physical, social, and emotional interactions among users and their surroundings, as well as the users, themselves. The research results are expected to be used in future studies on planning user-friendly and marketable products through in-depth analysis of the design characteristics of smart fashion products as well as consumer responses.

Electro-fatigue Characteristic of Shape Memory Alloy Applied to the Electrosurgical Knee Wand of Variation of Wand Head Angle in Electrosurgical Knee Surgeries (헤드각이 변화하는 Electrosurgical Knee Wand에 적용된 형상기억합금 스프링의 전기적 피로특성)

  • An, Jae-Uk;Kim, Cheol-Woong;Lee, Ho-Sang;Wang, Joon-Ho;Oh, Dong-Joon
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1547-1552
    • /
    • 2008
  • The tip of these catheter with straight needles is not able to reach in the vicinity of the disc bulging, which are the cause of the low back pain and because the far indirect radio-frequency treatment results in the decompression, the nucleoplasty has the limit. Many incurable diseases has not been solved due to the unexistence of the advanced technique for the MIS human body catheter device. To increase the possibility of nucleoplasty, the needle tip should be located at the closest area of the lesion. For this reason, the best way to increase the success rate of the operation is that the needle tip should access 3-dimensionally to the operating field as soon as possible. To achieve this aim, our studies are restricted as follows: 1) the SMA catheter design to control the 3-dimensional direction, 2) the security of the immediate response by the positive control of the SMA element thermal distribution using Peltier thermoelectric elements, 3) the aquisition of the control data by monitoring the relationship between the temperature of SMA element and the displacement, and 4) the design of the controller to guarantee the accurate location.

  • PDF

A Study on the Shape of KRISO Propulsion Efficiency Improvement Devices(K-duct) using CFD (CFD를 이용한 KRISO 추진효율 향상 장치(K-duct) 형상 특성에 관한 연구)

  • Kim, Jin-wook;Suh, Sung-Bu
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.55 no.6
    • /
    • pp.474-481
    • /
    • 2018
  • This paper is to compare by numerical analysis the flow characteristics and propulsion performance of stern with the shape change of K-duct, a pre-swirl duct developed by Korea Research Institute of Ships & Ocean Engineering (KRISO). First, the characteristics of the propeller and the resistance and self-propulsion before and after the attachment of the K-duct to the ship were verified and the validity of the calculation method was confirmed by comparing this result with the model test results. After that, resistance and self-propulsion calculations were performed by the same numerical method when the K-duct was changed into five different shapes. The efficiency of the other five cases was compared using the delivery horsepower in the model scale and the flow characteristics of the stern were analyzed as the velocity and pressure distributions in the area between the duct end and the propeller plane. For the computation, STAR-CCM +, a general-purpose flow analysis program, was used and the Reynolds Averaged Navier-Stokes (RANS) equations were applied. Rigid Body Motion (RBM) method was used for the propeller rotating motion and SST $k-{\omega}$ turbulence model was applied for the turbulence model. As a result, the tangential velocity of the propeller inflow changed according to the position angle change of the stator, and the pressure of the propeller hub and the cap changes. This regulated the propeller hub vortex. It was confirmed that the vortex of the portion where the fixed blade and the duct meet was reduced by blunt change.

Direction detection technique of radioactive contaminants based on rotating collimator (회전형 콜리메이터 기반 방사능 오염원의 방향탐지 기법)

  • Hwang, Young-Gwan;Song, Keun-Young;Lee, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.11
    • /
    • pp.1519-1527
    • /
    • 2020
  • AGeneral radiation measuring devices have been developed in the form of spatial dose rate detection devices that measure dose rates to radioactive contaminant and 2D or 3D imaging devices for radioactive contamination information. Each of these radiation detection techniques has advantages. The advantages of both detection devices are necessary to minimize personal injury and rapid decontamination in the area of a radioactive accident. In this paper, we proposed a technique that can measure the dose rate and direction information about the radioactive pollutant source in real time using a detection sensor, a rotating body, and a directional shield for radioactive pollutant detection. The rotational-based detection device is configured to check the dose rate and direction using the location information of the rotator and measurement value. We proposed a measurement technique for vertical and horizontal directions through multiple holes. It was confirmed that the measurement error for direction information was less than 1% when detected in the horizontal direction.

A method of assisting small intestine capsule endoscopic lesion examination using artificial neural network (인공신경망을 이용한 소장 캡슐 내시경 병변 검사 보조 방법)

  • Wang, Tae-su;Kim, Minyoung;Jang, Jongwook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.2-5
    • /
    • 2022
  • Human organs in the body have a complex structure, and in particular, the small intestine is about 7m long, so endoscopy is not easy and the risk of endoscopy is high. Currently, the test is performed with a capsule endoscope, and the test time is very long. The doctor connects the removed storage device to the computer to store the patient's capsule endoscope image and reads it using a program, but the capsule endoscope test results in a long image length, which takes a lot of time to read. In addition, in the case of the small intestine, there are many curves due to villi, so the occlusion area or light and shade of the image are clearly visible during the examination, and there may be cases where lesions and abnormal signs are missed during the examination. In this paper, we provide a method of assisting small intestine capsule endoscopic lesion examination using artificial neural networks to shorten the doctor's image reading time and improve diagnostic reliability.

  • PDF

EFFECT OF PULSED ELECTROMAGNETIC FIELD STIMULATION ON THE EARLY BONE CONSOLIDATION AFTER DISTRACTION OSTEOGENESIS IN RABBIT MANDIBLE MODEL (가토 하악골 골신장 후 맥동전자기장이 조기 골경화에 미치는 효과에 대한 연구)

  • Hwang, Kyung-Kyun;Cho, Tae-Hyung;Song, Yun-Mi;Kim, Do-Kyun;Han, Sung-Hee;Kim, In-Sook;Hwang, Soon-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.29 no.2
    • /
    • pp.123-131
    • /
    • 2007
  • Introduction: Distraction osteogenesis is widely used as for bone lengthening in patients with maxillofacial deformity and alveolar bone atrophy. One of the major problems in distraction osteogenesis is long consolidation period for 2-3 months, in which the devices have to be fixed on the bone to prevent relapse. It results in scar formation on the face, disturbance of mastication and speech. This study was performed to evaluate the stimulating effect of pulsed electromagnetic field on the early bone consolidation in distraction osteogenesis. Materials and methods: Total 10 rabbit were used (5 for control group, 5 for experimental group). A vertical osteotomy in the mandibular body was performed and the distraction device was fixed. After 5 days distraction was done 1mm per a day for 7 days. A pulsed electromagnetic field (38 Gauss, 60 Hz) was applied for 8 hours per day and it continued for 5 days immediately after distraction in the experimental group. Both groups were sacrificed after 2 weeks. Histological specimens with H&E and Masson Trichrome staining were made and histomorphometrically analysed with image analyser. Results: The device for distraction osteogenesis was displaced in one animal for each group, therefore, only four animals in both groups were evaluated. In both groups, a new bone formation was observed in the distracted area after 2 weeks. The bone formation was enhanced in the experimental groups ($31.76{\pm}8.68%$) compared with control group ($9.94{\pm}3.23%$), its difference was statistically significant (p<0.001). Conclusion: This study suggests that electrical stimulation with electromagnectic field may be effective in the early bone formation after distraction osteogenesis. Further studies with large number of animals are needed before clinical application.

u-EMS : An Emergency Medical Service based on Ubiquitous Sensor Network using Bio-Sensors (u-EMS : 바이오 센서 네트워크 기반의 응급 구조 시스템)

  • Kim, Hong-Kyu;Moon, Seung-Jin
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.13 no.7
    • /
    • pp.433-441
    • /
    • 2007
  • The bio-Sensors, which are sensing the vital signs of human bodies, are largely used by the medical equipment. Recently, the sensor network technology, which composes of the sensor interface for small-seize hardware, processor, the wireless communication module and battery in small sized hardware, has been extended to the area of bio-senor network systems due to the advances of the MEMS technology. In this paper we have suggested a design and implementation of a health care information system(called u-EMS) using a bio-sensor network technology that is a combination of the bio-sensor and the sensor network technology. In proposed system, we have used the following vital body sensors such as EKG sensor, the blood pressure sensor, the heart rate sensor, the pulse oximeter sensor and the glucose sensor. We have collected various vital sign data through the sensor network module and processed the data to implement a health care measurement system. Such measured data can be displayed by the wireless terminal(PDA, Cell phone) and the digital-frame display device. Finally, we have conducted a series of tests which considered both patient's vital sign and context-awared information in order to improve the effectiveness of the u-EMS.

Development of an Unmanned Conveyor Belt Recovery Skimmer for Floating Marine Debris and High Viscosity Oil (무인 컨베이어 벨트식 부유쓰레기 및 고점도유 회수장비 개발 연구)

  • Han, Sang-goo;Lee, Won-ju;Jang, Se-hyun;Choi, Jae-hyuk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.2
    • /
    • pp.208-215
    • /
    • 2017
  • When persistent oil, such as crude oil or Bunker C oil, is spilled at sea, viscosity increases through the weathering process. Equipment that can collect this oil when mixed with floating marine debris is very limited. In this study, devices that can be attached to the outside of existing oil skimmers have been applied to the inside of the main body, to develop an unmanned conveyor belt type floating marine debris and high viscosity oil recovery skimmer, which is composed of a conveyor belt, a sweeper with a forced inflow device, and a collection tank equipped with a buoyant body. The resulting skimmer was operated at a speed of 1.2 knots at a distance of 30 m in a sea area test. It was stable when moving laterally in any direction. An oil recovery performance test was conducted using a portable storage tank, and oil was recovered from a minimum of $7.8k{\ell}/h$ to a maximum of $23.3k{\ell}/h$. Moreover, recovery of $7.7k{\ell}/h$ was obtained in a wave water tank test with floating marine debris such as PET bottles and oil mixed. If the equipment developed in this study was used in the field for oil pollution accidents, it could be expected to contribute to improved response capability. We believe our equipment could be used in further studies to improvement the performance of existing portable oil skimmers.

Diagnosis of Diabetes Using Voltage Analysis Based on EIS (Electro Interstitial Scan) (EIS 기반 전압신호 분석을 통한 당뇨병 진단 가능성 평가)

  • Bae, Jang-Han;Kim, Soochan;Kaewkannate, Kanitthika;Jun, Min-Ho;Kim, Jaeuk U.
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.11
    • /
    • pp.114-122
    • /
    • 2016
  • EIS (Electro interstitial scan) is a non-invasive and simple method to find the physio-pathological information inferred by electric current response with respect to low direct current applied between remote sites of the body. Although a few EIS-based devices for diagnosing diabetes were commercialized, they were not successful in offering clinical validity nor in confirming diagnostic principle. In this study, we measured the voltage responses of diabetic patients and normal subjects with a commercialized EIS device to test the usefulness of EIS in screening diabetes. For this purpose, voltage was measured between pairs of electrodes contacted at both palm, both soles of the feet and left and right forehead above both eyes. After feature extraction of voltage signals, the AUC (area under the curve) between the two groups was calculated and we found that seven variables were appropriately shown above 60% of accuracy. In addition, we applied the k-NN (k-nearest neighbors) method and found that the accuracy of classification between the two groups reached the accuracy of 76.2%. This result implies that the voltage response analysis based on EIS has potential as a diabetics screening method.