• 제목/요약/키워드: body angles

검색결과 425건 처리시간 0.028초

What Effects Does Necrotic Area of Contrast-Enhanced MRI in Osteoporotic Vertebral Fracture Have on Further Compression and Clinical Outcome?

  • Lee, Ja Myoung;Lee, Young Seok;Kim, Young Baeg;Park, Seung Won;Kang, Dong Ho;Lee, Shin Heon
    • Journal of Korean Neurosurgical Society
    • /
    • 제60권2호
    • /
    • pp.181-188
    • /
    • 2017
  • Objective : The objective of this study was to analyze the correlation between further compression and necrotic area in osteoporotic vertebral fracture (OVF) patients with contrast-enhanced magnetic resonance imaging (CEMRI). In addition, we investigated the radiological and clinical outcome according to the range of the necrotic area. Methods : Between 2012 and 2014, the study subjects were 82 OVF patients who did not undergo vertebroplasty or surgical treatment. The fracture areas examined on CEMRI at admission were defined as edematous if enhancement was seen and as necrotic if no enhancement was seen. The correlation between further compression and the necrotic and edematous areas of CEMRI, age, and bone mineral density was examined. Also, necrotic areas were classified into those with less than 25% (non-necrosis group) and those with more than 25% (necrosis group) according to the percentages of the entire vertebral body. For both groups, further compression and the changes in wedge and kyphotic angles were examined at admission and at 1 week, 3 months, and 6 months after admission, while the clinical outcomes were compared using the visual analog scale (VAS) and Eastern Cooperative Oncology Group (ECOG) performance status grade. Results : Further compression was $14.78{\pm}11.11%$ at 1 month and $21.75{\pm}14.43%$ at 6 months. There was a very strong correlation between the necrotic lesion of CEMRI and further compression (r=0.690, p<0.001). The compression of the necrosis group was $33.52{\pm}12.96%$, which was higher than that of the non-necrosis group, $14.96{\pm}10.34%$ (p<0.005). Also, there was a statistically significantly higher number of intervertebral cleft development and surgical treatments being performed in the necrosis group than in the non-necrosis group (p<0.005). Moreover, there was a statistical difference in the decrease in the height of the vertebral body, and an increase was observed in the kyphotic change of wedge angle progression. There was also a difference in the VAS and ECOG performance scales. Conclusion : The necrotic area of CEMRI in OVF had a strong correlation with further compression over time. In addition, with increasing necrosis, intervertebral clefts occurred more frequently, which induced kyphotic changes and resulted in poor clinical outcomes. Therefore, identifying necrotic areas by performing CEMRI on OVF patients would be helpful in determining their prognosis and treatment course.

견, 두부 형태별 Shoulder Pad 두께에 관한 연구 - 여자대학생을 중심으로 - (A Study on the Reaction Somatotype of Shoulder and Neck with Thickness of Shoulder Pad - The Subject of the College Woman -)

  • 이은정;김순구;박정순
    • 한국의류학회지
    • /
    • 제15권2호
    • /
    • pp.139-150
    • /
    • 1991
  • The purpose of this study is to do the Somatotype classification according to the type of shoulder-neck and to give the thinkness of shoulder pad according to them. Therefore this study was measurement body size of 201 and the somatotypes were classified as their plumb line. The standard somatotype of this measurement was classified as 9 type according to its angle of shoulder inclination and neck length. Pads which have different thickness (1 cm, 1.5 cm, 2 cm) were attached to the 9 body type and the set-in sleeve blouse and raglan sleeve blouse were made and tring test and sensory test were accomplished. The results of this study were as follows: 1 . Classification of shoulder-neck relationship. Angles of shoulder inclination ($15^{\circ},\;21^{\circ},\;27^{\circ}$), lock lenaths (10 cm, 12.5 cm, 15 cm) were classi- fied as 3 type each and these types were combined as 9 types. II . The result of angle difference of shoulder inclination according to pad thickness. 1) In case of set-in pad. angle is increased $5.75^{\circ}$ per 1 cm of pad thickness. 2) In case of raglan pad. angle is increased $6.45^{\circ}$ per 1 cm of pad thickness. III. The most fit pad thickness to the 9 types. In case of set-in sleeve blouse. 1) High shoulder-long neck, Standard shoulder-long neck Low shoulder-long neck, Stan-dard shoulder·standard neck. Low shoulder-standard neck: 1.5 cm. 2) High shoulder-standard neck, Standard shoulder-short neck, Low shoulder-short neck: 1 cm. 3) High shoulder-short neck: 0 cm(without pad) In case of raglan sleeve blouse. 4) High shoulder-long neck, Standard shoulder-long neck, Low shoulder·long neck, Stan-dard shoulder-standard neck, Low shoulder-standard neck: 1.5 cm. 5) High shoulder-standard neck, Standard shoulder-short neck, Low-shoulder-short neck: 1 cm. 6) High shoulder-short neck: 0 cm(without pad)

  • PDF

한국 전통 금속 밥그릇의 조형적 해석 -조선 및 근대를 중심으로- (Figurative Analysis of Korea Tradition Metal Rice Bowl - To Choson and the Modern Age Center -)

  • 윤형건
    • 디자인학연구
    • /
    • 제17권1호
    • /
    • pp.99-108
    • /
    • 2004
  • 우리나라에서는 예전부터 밥그릇 전용으로 자기와 더불어 금속식기가 사용되어져 왔는데, 이러한 금속식기는 쌀을 주식으로 하는 나라에서는 유일한 것으로 우리나라 특유의 아이덴티티를 가지고 있다. 이를 근간으로 우리는 독자적이며 고유한 우리의 것들을 창조 할 수 있을 것이다. 본 연구의 방법은 문헌연구와 더불어 각 지역을 탐문하면서 조선 및 근대의 금속밥그릇을 실제 측정을 하여 다음과 같은 사실을 밝혔다. 우리나라 금속 밥그릇의 조형은 크게 합, 연엽, 오목, 옥발이 4가지 종류가 있다. 조형에 담긴 특징은 크게 3가지로 첫째는, 우리나라의 금속밥그릇에는 기본적으로 뚜껑이 있다는 점이다. 둘째, 우리나라의 금속밥그릇에는 남녀노소 전용이 있는가 하면 오목과 합은 남녀노소 공용이다. 셋째, 연령이 증가함에 따라 크기가 다른 밥그릇으로 교체해 나간다는 점이다. 그리고 금속밥그릇의 조형적 특징에 결정적인 영향을 주는 항목은 [ 굽의 유무], [ 구연부선 ], [ 구연부외경 / 몸체높이의 비], 그리고 [ 구연부외경 / 몸체 최대경의 비] 의 4가지이다. 글로벌화 되는 시대에 우리나라의 조형적 특질을 찾아 아이덴티티를 구축하는 것은 매우 중요하다. 본 연구는 우리나라 특유의 금속 밥그릇을 가지고 여러 각도에서 조명하여 우리나라의 디자인적 아이덴티티를 찾고 여러 상품에 접목시키고자 하는 것에 대한 기초적인 연구이다.

  • PDF

평균대 옆공중돌기 동작의 운동역학적 분석 (Kinetic Analysis of the Salto Side-Ward Tucked on the Balance Beam)

  • 여홍철;장재관
    • 한국운동역학회지
    • /
    • 제18권3호
    • /
    • pp.61-69
    • /
    • 2008
  • 본 연구는 평균대에서 필수요구조건(EGR)에 해당되는 동작인 옆공중돌기 동작의 성공과 실패를 운동역학적으로 비교 분석하였다. 연구대상은 국가대표 선수들로 하였으며, 연구의 목적은 기술의 실수 요인을 규명하여 지도자 및 선수들에게 과학적으로 유용한 정보를 제공하는데 있다. 성공시 옆공중돌기 동작의 신체중심은 평균대 중앙 중심으로 좌-우축으로 벗어나는 결과가 나타나고 동작의 특성상 회전하는 방향으로 신체중심이 이동한다는 것을 나타내고 있다. 도약구간인 event2와 3에서 성공시 상 하 변화가 크게 나타나 체공시간을 높이는 것으로 투사변인이 실패시 보다 높게 나타나는 결과를 뒷받침 해 주고 있다. 또한 공중 비약을 위해 다리를 차는 동작을 하는 오른쪽 고관절 각도와 속도, 각속도가 실패시 보다 성공시 동작에서 모두 크게 나타나 도약의 최적조건을 수행하고 있다. 어깨를 중심으로 상지분절의 속도와 견관절 각속도를 크게 함으로써 운동량을 증가시켰으며 그중 오른쪽 견관절 각속도가 크게 나타난 이유는 오른쪽 다리를 잡기 위한 결과이다. 옆 공중돌기 동작에서 실패시 보다 성공시 동작에서 x축을 중심으로 각운동량이 크게 나타나 공중 비행 동작은 x축을 중심으로 각운동량을 크게 하는 것이 중요한 요인으로 나타났으며 옆공중돌기 특성상 y축과 z축으로 각운동량도 적정한 비율로 동작이 이루어져야 성공적인 동작을 만들수 있다.

평판형 전개판의 3차원 운동 모델링 (Modeling of flat otter boards motion in three dimensional space)

  • 최무열;이춘우;이건호
    • 수산해양기술연구
    • /
    • 제43권1호
    • /
    • pp.49-61
    • /
    • 2007
  • Otter boards in the trawl are the one of essential equipments for the net mouth to be spread to the horizontal direction. Its performance should be considered in the light of the spreading force to the drag and the stability of towing in the water. Up to the present, studies of the otter boards have focused mainly on the drag and lift force, but not on the stability of otter boards movement in 3 dimensional space. In this study, the otter board is regarded as a rigid body, which has six degrees of freedom motion in three dimensional coordinate system. The forces acting on the otter boards are the underwater weight, the resistance of drag and spread forces and the tension on the warps and otter pendants. The equations of forces were derived and substituted into the governing equations of 6 degrees of freedom motion, then the second order of differential equations to the otter boards were established. For the stable numerical integration of this system, Backward Euler one of implicit methods was used. From the results of the numerical calculation, graphic simulation was carried out. The simulations were conducted for 3 types of otter boards having same area with different aspect ratio(${\lambda}=0.5,\;1.0,\;1.5$). The tested gear was mid-water trawl and the towing speed was 4k't. The length of warp was 350m and all conditions were same to each otter board. The results of this study are like this; First, the otter boards of ${\lambda}=1.0$ showed the longest spread distance, and the ${\lambda}=0.5$ showed the shorted spread distance. Second, the otter boards of ${\lambda}=1.0$ and 1.5 showed the upright at the towing speed of 4k't, but the one of ${\lambda}=0.5$ heeled outside. Third, the yawing angles of three otter boards were similar after 100 seconds with the small oscillation. Fourth, it was revealed that the net height and width are affected by the characteristics of otter boards such as the lift coefficient.

CBCT와 EXACTRAC을 이용한 Spine SBRT의 유용성 평가 (A Study to Evaluate the Efficacy of CBCT and EXACTRAC on Spine Stereotactic Body Radiation Therapy)

  • 최우근;박수연;박도근;송기원
    • 대한방사선치료학회지
    • /
    • 제25권2호
    • /
    • pp.167-173
    • /
    • 2013
  • 목 적: CBCT와 EXACTRAC을 이용한 Spine 체부정위적방사선 치료 Set up 시 이미지 보정 값과 실제 오차의 차이를 측정하고, 이 오차 값이 미치는 선량분포를 계산하여 CBCT와 EXACTRAC의 유용성을 평가하고자 한다. 대상 및 방법: Set up 오차 보정 값과 실제 오차 비교 실험을 위해서 QA용 Cubic phantom (The EASY CUBEr, Euromechanics, Schwarzenbruck, Germany)을 이용하였고, phantom의 중심축을 인위적으로 LR 방향으로 -1 mm, -2 mm, -3 mm SI 방향으로 1 mm, 2 mm, 3 mm 그리고 AP방향으로 1 mm, 2 mm, 3 mm 이동시켰으며, 중심축을 $0.5^{\circ}$씩 좌우로 회전시켜 CBCT와 EXACTRAC의 Auto matching 보정 값과 비교 측정하였으며, 이동된 오차 값을 가정하여 Rando Phantom을 이용한 Spine SBRT 플랜에 적용하여 재계산을 시행하였다. 결 과: Set up 보정 값과 실제 오차 비교실험에서 3D CBCT의 평균값은 LR, SI, AP 방향으로 0.15 mm 회전방향으로 $0.04^{\circ}$였고 EXACTRAC의 평균값은 LR, SI, AP 방향으로 0.18 mm 회전방향으로 $0.07^{\circ}$였다. 이동 값 오차를 가정한 선량 재계산 결과, SI방향 2, 3 mm 이동 시 $V_{10}$ (종양의 용적에 10 Gy가 들어가는 선량) Volume이 각각 10.574%, 10.712%가 나타났고 LR방향 -3 mm 이동 시 12.076%로 가장 높게 나타났다. 결 론: CBCT와 EXACTRAC의 Set up 보정 값과 실제 오차는 1 mm, $0.1^{\circ}$ 미만으로 두 시스템 모두 매우 정밀한 set up 오차보정을 보였다. 그러나 선량 재계산 시 3 mm 이상의 오차가 발생한 경우, Spine SBRT 치료 시 Spinal cord에 들어가는 선량이 $V_{10}$에서 3% 이상 최대선량 13 Gy 이상 증가함으로서 치명적인 흡수선량 오류가 발생할 수 있음을 확인하였다. 따라서 본 저자는 1회에 한한 Spine SBRT 치료 시 정확도 측면에서 종양의 단면 정보를 위치적으로 제공하는 CBCT가 더 유용할 것으로 사료된다.

  • PDF

창녕 교동 39·63호분 동물순장 연구 (A study on animal SHUNJANG in tombs 39 and 63 in Gyo-dong, Changnyeong)

  • 권주영;김보상
    • 헤리티지:역사와 과학
    • /
    • 제55권4호
    • /
    • pp.56-70
    • /
    • 2022
  • 창녕 교동 39호분과 63호분은 북쪽에 입구부를 둔 횡구식 묘제로 별도의 추가장이 이루어지지 않은 창녕지역의 독특한 묘제이다. 본고는 해당 고분의 매장 프로세스와 함께 고분의 입구부에 별도로 조성된 석곽 2기의 성격과 의미를 이해하고자 하였다. 이 2기의 석곽은 39호분의 석곽 3호(39-3호)와 63호분의 석곽 3호(63-3호)로 대형분 내에 독립되어 조성된 소형 무덤이다. 2기 모두 매장주체부의 북벽 중위에 위치하며 한쪽 벽면을 매장주체부 벽석과 공유하고 있는데 축조상태로 보아 주피장자를 석곽 내부에 안치한 뒤 북벽을 폐쇄하는 과정에서 조성되었다. 석곽 내부에는 동물유체가 모두 확인되었는데 특히 63-3호 동물유체 동정결과 최소 3개체의 개가 매장된 것으로 추정되었다. 무엇보다 이들 동물유체는 주피장자를 등진 상태로 머리를 바깥쪽으로 향하고 있으며 한정된 공간 내에 중첩되지 않고 나란히 안치되어 있어 주목된다. 창녕 교동 39-3호와 63-3호는 매장주체부를 축조하는 과정에서 조성된 것으로 동시성을 가지며 각각의 독립된 유구이지만한 고분 내에서 주피장자를 따라 축조되었다는 종속적 관계를 형성한다. 또한 동물을 살해한 뒤 해체되지 않은 상태로 일정한 방향에 따라 정연하게 안치하였다는 점에서 강제성을 띠고 있다. 이에 유구의 성격은 개(견(犬))를 순장한 순장곽(殉葬槨)으로 이해된다. 삼국시대 고분 출토 동물유체에 대한 연구는 그 위치에 따라 동물부장, 제수매납, 동물희생 등으로 해석되며 이는 일련의 동물희생의례, 즉 동물 부장과 희생(제생(祭牲) 혹은 공희(供犧))으로 알려져 있다. 이러한 인식의 바탕에는 동물을 음식이나 제의 희생물과 같이 물적 대상화하는데 기반하고 있다. 그런데 창녕 교동 39-3호와 63-3호는 장송의례 과정에서 동물을 영적존재로 인식하고 주피장자의 계세사상과 밀접하게 연관된다는 점에서 차이를 보인다. 또한 유구의 위치와 방향성에 대한 다각도로의 분석도 요구되는데, 이 2기의 순장곽이 고분의 입구부에 해당하며, 위치가 입구부의 가장 개방된 공간이라는 점, 바깥을 향해 바라보는 개의 모습 등은 고분 수호와 벽사의 의미로도 해석이 가능하다. 이러한 모습은 고대 계세사상을 반영하는 고구려 벽화고분에 묘사된 개의 그림과 백제 무령왕릉 출토 석수와도 비교가 가능하며 고대 무덤을 지키는 진묘수의 의미와도 상통한다. 이는 차후 동물유체 매장유구에 대해 다각적인 연구가 필요하다는 점을 시사하는 바이다.

경추 정면 검사에서 방사선 입사각에 관한 연구 (A Study of Radiation Incidence Angle in Anteroposterior Cervical Vertebra Examination)

  • 정성운;임청환;한범희;정홍량;주영철;박미자
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제35권2호
    • /
    • pp.83-92
    • /
    • 2012
  • 경추 정면 방사선검사시 하악골, 후두골의 겹침방지, 경추 추체의 배열 및 관절의 형태 등을 관찰하기 위하여 X선 입사각을 머리 방향으로 $15{\sim}20^{\circ}$를 주고 있는 것이 보편적이다. 하지만 한국인의 체형에 맞는 입사각에 대한 연구는 거의 이루어지지 않고 있다. 이에 본 연구에서는 한국인에 적합한 입사각을 찾고, 방법을 제시하는데 목적이 있다. 입사각을 측정하기 위하여 서산에 위치한 S병원을 내원한 환자 1,044명을 대상으로 하였으며, 제 2번~제 5번 경추의 길이, 피사체-영상판 거리(OID), 제2번경추(axis)의경사도, 초점-영상판 간거리(FID)를 측정하였으며, 연령대 성별에 대한 평균값을 측정하여 적용공식에 의하여 입사각을 산출하였다. 경추 제2번~제5번의 평균길이는 6cm 이였으며, 10대부터 20대까지는 경추의 길이가 커지고 30대 이후로는 경추의 길이가 작아졌으며, 남성과 여성의 차이는 약 1cm 차이가 나타났다(p<.001). OFD는 연령대, 성별과 상관없이 거의 같은 값이 측정이 되었다. 제2번 경추(axis)의 경사도는 10대와 20대는 경사도가 증가하였지만, 30대 이후로는 작게 나타났다. 또한 남성과 여성은 약 $2^{\circ}$차이가 났다(p<.001). FID의 측정 결과, 연령대, 성별과 상관없이 거의 같은 값이 측정되었으며, 이 값으로 입사각을 측정한 결과, 10대는 $15.9^{\circ}$, 20대 $16.9^{\circ}$, 30대 $16.6^{\circ}$, 40대 $16.2^{\circ}$, 50대 $15.9^{\circ}$, 60대 $14.5^{\circ}$로 측정되었다. 10대와 20대까지 입사각이 증가하였지만, 30대 부터는 입사각이 작게 나타났다. 또한 10대는 남성과 여성이 같은 값으로 측정이 되었고, 20대부터는 남성과 여성이 $2^{\circ}$ 차이가 나타났다. 입사각과 제 2번~제 5번 경추의 길이측정, OID, 제 2번 경추의 경사도, FID와의 상관관계를 실시하였고, 입사각과 모두 유의한 상관관계가 나타났다(p<.001). 본 연구에서 경추의 평균 길이, OID, FID, 제2번 경추(axis)의 경사도에 따라서 입사각이 다르게 나타났고, 성별과 연령에 따라 입사각이 다른 것을 알 수 있었다. 그러므로 경추 정면검사 시 연령, 성별을 고려하여 입사각을 설정하면서 검사를 시행하여야 함이 사료되며, 향후 경추검사의 입사각을 설정할 때 참고 자료로 이용될 것으로 기대된다.

착지 높이와 지면 형태가 하지 관절에 미치는 영향 (The Effect on the Lower Limbs Joint as the Landing Height and Floor Pattern)

  • 김은경
    • 한국운동역학회지
    • /
    • 제21권4호
    • /
    • pp.437-447
    • /
    • 2011
  • In this study, the lower limbs joints were analyzed for features based on the biomechanical characteristics of landing techniques according to height and landing on the ground type (flats and downhill). In order to achieve the objectives of the study, changes were analyzed in detail contents such as the height and form of the first landing on the ground at different angles of joints, torso and legs, torso and legs of the difference in the range of angular motion of the joint, the maximum angular difference between joints, the lower limbs joints difference between the maximum moment and the difference between COM changes. The subjects in this study do not last six months did not experience joint injuries 10 males in 20 aged were tested. Experimental tools to analyze were the recording and video equipment. Samsung's SCH-650A model camera was used six units, and the 2 GRF-based AMTI were used BP400800 model. 6-unit-camera synchronized with LED (photo cell) and Line Lock system were used. the output from the camera and the ground reaction force based on the data to synchronize A/D Syc. box was used. To calculate the coordinates of three-dimensional space, $1m{\times}3m{\times}2m$ (X, Y, Z axis) to the size of the control points attached to the framework of 36 markers were used, and 29 where the body was taken by attaching a marker to the surface. Two kinds of land condition, 40cm and 60cm in height, and ground conditions in the form of two kinds of flat and downhill slopes ($10^{\circ}$) of the landing operation was performed and each subject's 3 mean two-way RM ANOVA in SPSS 18.0 was used and this time, all the significant level was set at a=.05. Consequently, analyzing the landing technique as land form and land on the ground, the changes of external environmental factors, and the lower limbs joints' function in the evaluation were significantly different from the slopes. Landing of the slop plane were more load on the joints than landing of plane. Especially, knee extensor moment compared to the two kinds of landing, slopes plane were approximately two times higher than flat plane, and it was statistical significance. Most of all not so much range of motion and angular velocity of the shock to reduce stress was important. In the further research, front landing as well as various direction of motion of kinetic, kinetic factors and EMG variables on lower limbs joints of the study in terms of injury-prevention-approach is going to be needed.

지적재조사 측량에 적용을 위한 반사시트 타깃 토털스테이션 측량의 정확도 평가 (Accuracy Evaluation of Reflective Sheet Target Total Station for Applying in Cadastral Resurvey)

  • 박기헌;홍성언
    • 대한공간정보학회지
    • /
    • 제22권4호
    • /
    • pp.91-97
    • /
    • 2014
  • 본 연구에서는 건축물의 구조적 다양성에 따른 토털스테이션 측량과 GPS 측량의 어려움을 보완하고, 무 프리즘 토털스테이션 측량의 건물 재질에 따른 오차 문제를 보완할 수 있는 측량으로 반사시트 토털스테이션 방법을 이용한 건축물 경계 측량의 정확도를 분석하여 지적재조사 측량에서의 활용가능성을 평가하고자 한다. 반사시트 타깃을 거리에 따른 반사각도별로 실험한 결과, 반사각도가 $90^{\circ}$에서는 RMSE가 1.2mm에서 2.8mm로, $60^{\circ}$에서는 2.2mm에서 4.0mm로, $30^{\circ}$에서는 2.5mm에서 4.4mm로 분석되었다. 그리고 실제 건축물의 경계측량을 실험 해본 결과 기존 프리즘과 반사시트 타깃과의 오차는 X축의 RMSE가 0.043m, Y축의 RMSE가 0.038m로 나타났다. 이러한 오차의 발생 원인은 프리즘 소자 뭉치를 건축물의 모서리에 정확히 부착하지 못하는데서 일어나는 오차로 판단된다. 따라서 지적재조사 측량에서 건축물의 경계를 측정할 때 반사시트 타깃을 동시에 활용한다면 건축물의 구조적 문제로 인한 시준의 한계 및 오차 발생에 있어서 상당한 도움이 될 것으로 판단된다.