• 제목/요약/키워드: blood vessel elasticity

검색결과 16건 처리시간 0.018초

관상동맥질환 위험정도와 혈관탄성의 관계에서 치료지시이행의 매개효과: 경피적 관상동맥 중재술 환자 대상 (Comparison of Vessel Elasticity according to Risk Factors for Coronary Artery Disease, and the Mediating Effects of Treatment Compliance among Patients with Percutaneous Coronary Intervention)

  • 여가람;성경미
    • 동서간호학연구지
    • /
    • 제22권1호
    • /
    • pp.32-40
    • /
    • 2016
  • Purpose: This study aimed to provide basic data for vascular health of patient who underwent percutaneous coronary intervention (PCI) by verifying the mediating effect of compliance in the relationship between risk level of coronary artery disease (CAD) and blood vessel elasticity. Methods: This is a descriptive study with 115 patients, who underwent the PCI a year ago and visited in the cardiology department from January to March, 2015. The risk level of CAD, blood vessel elasticity and the compliance were measured. For data analysis, SPSS/WIN 21.0 and AMOS (IBM) 21.0 were used. Results: There were a positive correlation with blood vessel elasticity score (i.e. inelasticity of the blood vessel wall) (r=.189) and a negative correlation with compliance (r=-.658) in mediating effect of risk level of CAD. There was a negative correlation between compliance and blood vessel elasticity (r=-.482). The direct effect (${\beta}=-.226$), indirect effect (${\beta}=.415$) and total effect (${\beta}=.186$) of mediating effect of risk level of CAD on blood vessel elasticity were significant. Compliance had a partial mediating effect of risk level of CAD on blood vessel elasticity. Conclusion: The results of this study suggest that managing and preventing moderating effect of risk level of CAD on compliance is helpful in restoring blood vessel elasticity.

유산소 운동이 중년흡연남성의 혈관건강에 미치는 영향 (Effects of Aerobic Exercise on Middle-aged Male Smokers' Blood Vessel Health)

  • 김종인;정해천;원준연;가성순;오복실
    • 디지털융복합연구
    • /
    • 제12권4호
    • /
    • pp.349-356
    • /
    • 2014
  • 본 연구는 최근 높아지고 있는 혈관질환의 주요 요인인 흡연의 폐해를 유산소 운동을 통해 개선되는지의 여부를 규명하고, 나아가 유산소 운동을 통해 흡연자들의 혈관건강(혈압, 맥압, 혈관탄성)에 운동이 미치는 긍정적인 영향에 대하여 알리고자 하는데 목적이 있다. 대상자들은 40~55세의 흡연남성 40명을 대상으로, 20명은 유산소 운동그룹(Aerobic Exercise Group: AEG), 20명은 비 운동 그룹(Non Exercise Group: NEG)로 나누어 실행하였으며, 대상자 40명의 혈압과 맥압, 혈관탄성을 측정 후 AEG군은 12주간 1주일에 3회, 1회 50분 동안 유산소운동 프로그램에 따라 운동하였고, NEG군은 12주 동안 특별한 실험 조치 없이 평소와 같이 생활하도록 한 후, 12주 후 혈압과 맥압, 혈관탄성을 실험 전과 같은 방법으로 측정하였다. 실험결과 두 그룹 간 수축기 혈압의 차이는 유의한 수준을 나타내지 않았고 이완기 혈압은 유의한 수준을 나타내었다. 맥압의 측정 결과 두 그룹 간 유의한 차이가 나타났다. 혈관탄성의 결과 왼손, 오른손, 왼발, 오른발의 모든 측정 부위에서 두 그룹 간 유의한 차이가 나타났다. 따라서 유산소 운동이 흡연 중년남성의 혈관건강에 긍정적인 영향을 미치는 것으로 나타났다.

순환운동이 50대 비만중년여성의 건강체력, 혈압 및 혈관탄성도에 미치는 영향 (Effects of circulation exercise on health-related physical fitness, blood pressure and blood vessel elasticity of obese women in the 50s)

  • 김연주;김지현;하수민;김정숙;김종원;윤병곤;김도연
    • 한국응용과학기술학회지
    • /
    • 제34권4호
    • /
    • pp.756-768
    • /
    • 2017
  • 본 연구는 50대 비만중년여성을 대상으로 순환운동이 건강체력, 혈압 및 혈관탄성도에 미치는 영향을 규명하는데 있었으며, 이를 위해 비만중년여성 24명을 대상으로 운동그룹 12명, 대조군 12명으로 분류하여 8주간 순환운동 프로그램을 실시하였다. 순환운동 프로그램은 유산소 운동과 저항운동으로 구성되었으며, 회당 40분간, 주3회 실시하였고, 유산소 운동 수행강도는 50-70% HRmax, 저항운동은 1-RM의 40-60%로 수행되었으며, 순환운동 전 후에 측정한 자료의 그룹 내 차이 비교를 위해 대응표본 T검정, 그룹 간 차이는 운동 전 후의 변화율을 산출하여 독립표본 T검정을 실시하였다. 그 결과 운동그룹은 건강 체력 중 BMI(p<.05)가 유의하게 감소하였고, 심폐지구력(p<.001), 근지구력(p<.001), 유연성(p<.01)이 증가하였으며, 그룹 간 대조군 보다 심폐지구력, 유연성이 유의하게 증가되었다(p<.01). 수축기 혈압과 이완기 혈압은 운동그룹이 유의하게 감소하였으며(p<.01), 이완기 혈압은 그룹 간 대조군 보다 운동그룹이 유의하게 감소하였다(p<.05). PWV는 운동그룹이 유의하게 감소하였고(p<.05), 대조군이 유의하게 증가하였으며(p<.01), 그룹 간 대조군 보다 운동군이 유의하게 감소하였다(p<.05). 이상의 결과 비만중년여성의 건강증진 및 비만치료를 위한 순환운동은 건강체력, 혈압 및 혈관탄성도에 긍정적인 영향을 미친 것으로 사료된다.

선형 트랜스듀서를 이용한 혈관 변형률 영상법 (Blood Vessel Strain Imaging Using Linear Array Transducer)

  • 안동기;정목근
    • 한국산학기술학회논문지
    • /
    • 제11권3호
    • /
    • pp.880-890
    • /
    • 2010
  • 뇌졸중 등의 혈관 질병을 진단하기 위해서 혈관 내 초음파(Intravascular Ultrasound:IVUS)영상 기법이 사용되고 있다. 최근에는 혈관 내벽에 붙은 혈전을 탄성 영상법을 이용하여 진단하는 방법들이 연구되고 있다. 그러나 혈관 내 초음파는 혈관 내에 트랜스듀서를 삽입하여야 하므로 진단 방법에 위험성이 있다. 본 논문은 선형 트랜스듀서를 이용하여 혈관 외부에서 데이터를 획득하여 혈관 내벽에 붙은 혈전의 변형률 영상을 얻었다. 혈관 벽의 움직임을 정확하게 측정하기 위하여, 혈관 벽과 수직이 되도록 주사선의 방향을 조향하면서 초음파 데이터를 획득하였다. 초음파 데이터는 기저대역의 복소수 신호로 복조한 뒤 자기상관(autocorrelation)을 이용하여 혈관 벽의 움직임을 계산하여 변형률 영상을 얻었다. 제안한 방법을 플라스틱 기반의 혈관 모사 팬텀을 제작하여 검증하였다. 혈관 모사 팬텀은 혈관에 해당하는 직경 6mm의 실린더 공간에 물을 채우고 벽을 따라 2mm 두께의 부드러운 혈전을 혈관 벽의 내부에 배치하였다. RF 데이터는 상용 초음파 진단기에서 7.5MHz 선형 트랜스듀서를 사용하여 -40도부터 40도까지 1도 간격으로 조향시킨 81개의 스캔라인 데이터를 얻었다. 실험 결과 단단한 배경 팬텀에 인접한 혈전 영역이 더 무른 것으로 관찰되었다. 제안한 방법의 탄성 영상법이 비록 주사선이 혈관 벽에 수직으로 입사하는 영역으로 제한되지만 혈관 변형률 영상법의 유용함을 실험으로 입증하였다.

생체 유사재료를 설명하는 물질 상수 추정 (Estimating Material Parameters of Rubber-liked Material Similar to Biomaterial)

  • 강태원
    • 한국생산제조학회지
    • /
    • 제22권1호
    • /
    • pp.45-49
    • /
    • 2013
  • It is important to have a well developed strain energy function in order to understand the mechanical behavior of biomaterial like the blood vessel of artery. However, since it is not possible to have a complete form of strain energy function of artery, theoretical framework describing the behaviour of Rubber-like material which is similar to blood vessel is applied to infer useful forms of strain energy function of biomaterial. Based on Chuong-Fung model and Mooney-Rivlin model, material parameters are estimated based on experimental data. From the results, it can be inferred that the estimated parameters can be used to explain the difference of mechanical characteristics between normal vessel and vessel with stent.

Tensile Characteristics and Behavior of Blood Vessels from Human Brain in Uniaxial Tensile Test

  • Suh, Chang-Min;Kim, Sung-Ho;Ken L. Monson;Werner Goldsmith
    • Journal of Mechanical Science and Technology
    • /
    • 제17권7호
    • /
    • pp.1016-1025
    • /
    • 2003
  • The rupture of blood vessels in the human brain results in serious pathological and medical problems. In particular, brain hemorrhage and hematomas resulting from impact to the head are a major cause of death. As such, investigating the tensile behavior and rupture of blood vessels in the brain is very important from a medical point of view. In the present study, the tensile characteristics of the blood vessels in the human brain were analyzed using a quasi-static uniaxial tensile test, and the properties of the arteries and veins compared. In addition, to compare the tensile behavior and demonstrate the validity of the experimental results, blood vessels from the legs of pigs were also tested and analyzed. The overall results were in accordance with the histological structures and previous medical reports.

생체재료를 설명하는 스트레인 에너지 함수에 대한 이론적 고찰 (Theoretical Framework For Describing Strain Energy Function on Biomaterial)

  • 강태원
    • 한국생산제조학회지
    • /
    • 제22권1호
    • /
    • pp.50-55
    • /
    • 2013
  • In order to understand the biomaterial like the blood vessel of artery, there is a need to quantify the biomechanical behavior of the vessel. However, theoretical framework to describe and quantify the behaviour of blood vessel was not well established so far. For studying the biomechanical behavior of artery, Rubber-liked material which is similar to passive artery is selected since conventional theoretical interpretation is very limited to understand and predict the behavior of biomaterial. Rubber-like material is assumed to be very similar to artery and has properties of isotropy, homogeneity and is undergoing large deformation. Based on this assumption, stress developed on Rubber-like material is described by strain energy function and strain invariants which are required to understand the nonlinear elastic behavior of biomaterial. The descriptor which would be used for understanding the biomechanical behavior of artery is studied in this work.

혈관 유연성을 고려한 경동맥 분기부 모델 혈류역학 해석 (NUMERICAL ANALYSIS OF BLOOD FLOW DYNAMICS AND WALL MECHANICS IN A COMPLIANT CAROTID BIFURCATION MODEL)

  • 투안;이상욱
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.500-503
    • /
    • 2011
  • Blood flow simulations in an idealized carotid bifurcation model with considering wall compliance were carried out to investigate the effect of wall elasticity on the wall shear stress and wall solid stress. Canonical waveforms of flowrates and pressure in the carotid arteries were imposed for the boundary conditions. Comparing to rigid wall model, generally, we could find an increased recirculation region at the carotid bulb and an overall reduced wall shear stress. Also, there was appreciable change of flowrate and pressure waveform in longitudinal direction. Solid and wall shear stress concentration occurs at the bifurcation apex.

  • PDF

비선형 탄성이론에 기초한 혈관류 생체재료 실험장치 (Rubber-liked Biomaterial Experimental Setup based on Nonlinear Elasticity Theory)

  • 강태원
    • 한국정밀공학회지
    • /
    • 제27권6호
    • /
    • pp.90-97
    • /
    • 2010
  • In order to understand the biomaterial like the blood vessel of artery, there is a need to quantify the biomechanical behavior of the vessel. Using computer-controlled experimental system, the experiment can acquire data such as inner pressure, axial load, diameter and axial gauge length without contacting the specimen. Rubber-liked material which is similar to passive artery was selected as pseudo-biomaterial. Deformations are measured for pressure-diameter curves. The data were collected and stored online to be used in the feedback control of experimental protocols. Finally, the illustrative data obtained from the experimental system were presented and the system shows that strain invariants are controlled to understand the nonlinear elastic behavior of biomaterial which is involved with strain energy function.

벽 탄성도가 확장관(인조혈관) 벽 전단변형률에 미치는 영향 (The Effects of Wall Elasticity on Wall Shear Rate of a Divergent Tube (Vascular Graft))

  • 이계한;이상만
    • 대한기계학회논문집A
    • /
    • 제23권6호
    • /
    • pp.912-921
    • /
    • 1999
  • Shear stress acting on the arterial wall by blood flow is an important hemodynamic factor influencing blocking of blood vessel by thickening of an arterial wall. In order to study the effects of wall elasticity on the wall shear rate distribution in an artery-divergent graft anastomosis, a rigid and a elastic model are manufactured. These models are placed in a pulsatile flow loop, which can generate the desired flow waveform. Flow visualization method using a photochromic dye is used to measure the wall shear rate distribution. The accuracy of measuring technique is verified by comparing the measured wall shear rate in the straight portion of a model with the theoretical solution. Measured wall shear rates depend on the wall elasticity and flow waveform. The mean and maximum shear rate in the elastic model are lower than those in rigid model, and the decreases are more significant near the end of a divergent tube. The reduction of mean and maximum of wall shear rate in an elastic model are up to 17 percent.