• Title/Summary/Keyword: biomedical monitoring

Search Result 455, Processing Time 0.031 seconds

Molecular Characterization of Salmonella Genomic Island 1 in Proteus mirabilis Isolates from Chungcheong Province, Korea

  • Sung, Ji Youn;Kim, Semi;Kwon, GyeCheol;Koo, Sun Hoe
    • Journal of Microbiology and Biotechnology
    • /
    • v.27 no.11
    • /
    • pp.2052-2059
    • /
    • 2017
  • The emergence and dissemination of Salmonella genomic island 1 (SGI1) are strongly associated with the occurrence of multidrug-resistant (MDR) enterobacteria in humans and animals. Diverse SGI1s have been reported among Salmonella enterica and Proteus mirabilis in several countries. We aimed to characterize SGI1 in P. mirabilis isolates from humans and chickens in Chungcheong Province, Korea. A total of 44 P. mirabilis isolates were recovered from humans (n = 20) and chickens (n = 24). Antimicrobial susceptibility was determined by disk diffusion assay. To detect and characterize SGI1s, PCR amplification and PCR mapping experiments were performed. Repetitive extragenic palindromic-PCR (REP-PCR) was performed to assess the clonality of the isolates. The four P. mirabilis strains (16.7%) from chicken harbored a SGI1, whereas none of the isolates from clinical specimens contained SGI1. The SGI1s detected in our study were all confirmed as SGI1-PmABB harboring aminoglycoside-resistant genes (aacCA5 and aadA7). In P. mirabilis isolates, the presence of SGI1-PmABB was significantly correlated with high resistance rates of the isolates to antimicrobial agents, such as gentamicin, streptomycin, and spectinomycin. Moreover, the four SGI1-bearing isolates showed the same REP-PCR patterns and that suggested both horizontal and clonal spread of the isolates. This study is the first attempt to determine SGI1s in P. mirabilis isolates in Korea. We confirmed that P. mirabilis isolates carrying SGI1-PmABB were distributed at poultry farms in Korea. The present study emphasizes the need for continuous monitoring of SGI1s to prevent spreading of the MDR genomic islands among P. mirabilis isolates from humans and animals.

A Study Left Ventricular Volume Change Measurement using Nuclear Stethoscope (핵청진기를 이용한 좌심실 부피변화 측정에 관한 연구)

  • Min, Byeong-Gu;Kim, Yeong-Ho;Go, Chang-Sun
    • Journal of Biomedical Engineering Research
    • /
    • v.5 no.2
    • /
    • pp.167-172
    • /
    • 1984
  • In the present study, we developed a nuclear stethoscope interfaced with a personal computer (APPLE- II) and evaluated it's performances as compared with the gamma camera. This single-probe, ECG-gated system has been used for displaying the left ventricular time-activity curves, the peak ejection time and its rate, the peak filling time and its rate, and the R-R interval distribution. The radioactivity was measured at every 10msec around the ventricular region, where the activity curves shows the maximal peak to peak variations. The background activity was measured around the lung area showing its counts approximately 50% of the end-diastolic count with minimal variations. The average time-activity curves of 100 beats were used for analysis in the equilibrium study after intravenous injection of 15-20mCi of Tc. The ejection fractions measured by the nuclear stethoscope(Y) were compared with those measured by gamma camera(X) in 47 patients with various heart diseases. The correlation coefficient between two measurements was 0.766 with a relation of Y=1.04 x-8.48. Also, the high reproducibility was obtained for the same patient. Also, the high reproducibility was obtained for the same patient. From this study, we conclude that this device is useful for continuous monitoring in the intensive care unit, as it is portable, compact, and inexpensive.

  • PDF

Development of Active Suspension System for Wheelchairs to Improve Riding Comfort of Gait Disorders (보행 장애인의 승차감 개선을 위한 휠체어용 능동형 서스펜션 시스템 개발)

  • Heo, Yeong Jun;Jeon, Geum Sang;Lee, Sang Hun;Choi, Seong Dae;Jang, Ik Gyu
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.203-209
    • /
    • 2020
  • As the number of people with gait disorders increases, the demand for using wheelchairs increases and the area of a ctivity for people with disabilities expands, thereby they increasing the demand for riding comfortability in various driving environments. Therefore, this study is to develop an entry-level active suspension system that apply to wheelchairs and to evaluate its usability. The suspension applied in this paper consists of a coil spring, a shock absorber, a control module to control the strength of the shock absorber, and a road surface condition monitoring system. A wheelchair occupant secures the riding comfort by adjusting the coil strength of the shock absorber in 12 steps according to various road conditions. Therefore, the mechanical properties were evaluated through the structural analysis of the suspension system, and the tendency toward the magnitude of the road surface vibration attenuated according to the rigidity of the suspension through the vibration test was attempted. In conclusion, as a result of structural analysis of the suspension system, stress in a range lower than the yield strength of the material was generated, and the vibration test showed the effect of attenuating the vibration generated from the road surface when the stiffness of the suspension was adjusted.

Single use Automatic Lancet to Minimize Pain During Skin Puncture (피부관통시 통증을 최소화하는 일회용 자동 모세혈액 채취기구)

  • 김현식;김경아;전명희;김태임;정용현;이태수;차은종
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.4
    • /
    • pp.323-327
    • /
    • 2002
  • Chronic diabetic patients need to sample capillary blood for monitoring and controlling the blood sugar level. Frequent sampling requires to minimize pain during skin puncture. The present study developed mechanisms to minimize pain with effective sampling procedure. which consisted of tapered spring, guiding tunnel, and 30G needle Penetration depth was limited to within 2mm for pain reduction as well as for safety. Simple no-reuse mechanism also prevented the cross-patient and secondary infection possibility. Clinical experiments demonstrated the best convenience and safety with minimal pain in the diabetes, normal, and nursing students groups. Sing1e blood sampling was enough for successful blood sugar test by portable analyzer. The present sing1e use auto-lancet should be of great convenience in frequent capillary blood sampling for the diabetes.

Ginsenosides Inhibit HMGB1-induced Inflammatory Responses in HUVECs and in Murine Polymicrobial Sepsis

  • Lee, Wonhwa;Ku, Sae-Kwang;Jeong, Tae Cheon;Lee, Sangkyu;Bae, Jong-Sup
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.10
    • /
    • pp.2955-2962
    • /
    • 2014
  • Asian ginseng is used as a treatment for cardiovascular diseases, ischemia, and cancers. High mobility group box 1 (HMGB1) protein acts as a late mediator of severe vascular inflammatory conditions. However, the effect of ginsenosides from Asian ginseng on HMGB1-induced inflammatory responses has not been studied. We addressed this question by monitoring the effects of ginsenoside treatment on lipopolysaccharide (LPS) and cecal ligation and puncture (CLP)-mediated release of HMGB1, and HMGB1-mediated regulation of proinflammatory responses. Ginsenoside treatment suppressed LPS-mediated release of HMGB1 and HMGB1-mediated cytoskeletal rearrangements. Ginsenosides also inhibited HMGB1-mediated inflammatory responses. In addition, ginsenosides inhibited the production of tumor necrosis factor-${\alpha}$ (TNF-${\alpha}$) and activation of protein kinase B (Akt), nuclear factor-${\kappa}B$ (NF-${\kappa}B$), and extracellular-regulated kinases (ERK) 1/2 by HMGB1. Ginsenosides also decreased CLP-induced release of HMGB1, production of interleukin (IL) $1{\beta}/6$, and mortality. These results suggested that ginsenosides may be potential therapeutic agents for treatment of vascular inflammatory diseases through inhibition of the HMGB1 signaling pathway.

Theoretical Analysis of Phase Detector Technique for the Measurement of Cell Membrane Capacitance During Exocytosis (세포외 분비시 막 캐패시턴스를 측정하기 위한 위상감지법(phase detector technique)의 이론적 분석.)

  • Cha, Eun-Jong;Goo, Yong-Sook;Lee, Tae-Soo
    • Progress in Medical Physics
    • /
    • v.3 no.2
    • /
    • pp.43-57
    • /
    • 1992
  • Phase detector techique provides a unique probe to membrane recycling phenomenon by enabling dynamic monitoring of cell membrane capacitance. However, it has inherent errors due to constant changes in measurement environments. The present study analyzed several error sources to develope application criteria of this technique. and the following was found based on a theoretical analysis. The initial phase angle has to be appropriately selected to minimize the error due to perturbation of access and membrane conductances. Excitation frequency is also important to determine the initial phase angle. However. deviation of the phase angle from a predetermined initial value during the measurement period does not affect capacitance estimation to a significant degree. Despite an appropriate initial phase selection an error in scaling factor is expected for a large increase in capacitance during exocytosis. which may be overcome by iteratively correcting the scaling factor over the measurement period. These results will provide a useful guideline in practical application of this technique.

  • PDF

The Development of Extravasation Detection Accessory System for the Preventive Contrast Media Extravasation in the Computed Tomography: A Preliminary Report (CT 검사에서 조영제의 혈관외유출 예방을 위한 EDA 시스템 개발의 예비 보고)

  • Kweon Dae-Cheol;Jeong Seok-Hee;Kim Tae-Hyung;Kim Jeong-Goo;Park Peom
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.32-39
    • /
    • 2006
  • To assess the ability of an extravasation detection accessory (EDA) system to detect clinically important extravascular injection of iodinated contrast material delivered with an automated power injector. Fifty patients referred for contrast material enhanced body computed tomography studied in a prospective, observation study in which the EDA system was used to identify and interrupt any injection associated with clinically Important extravasation. The presence or absence of extravasation was definitively established with multi-detector CT at the injection site (injection rate, $2.0{\sim}2.5$ mL/sec). There were two true positive, extravasation volumes $22{\sim}25$ mL. The EDA system had sensitivity in the detection of clinically important extravasation. The EDA system is easy to use, safe, and accurate In the monitoring of intravenous injections for extravasation, which may prove especially useful in CT applications.

  • PDF

Development of Estimation Methods of Skin Oxidation and Evaluation of Anti-Oxidative Effects of Genistein in Topical Formulations

  • Kim, Seong-Yeon;Na, Yeon-Joo;Kim, Dong-Ju;Kim, Yeong-Seok;Kim, Hyeong-Min;Hwang, Sung-Ha;Kwak, Ji-Yeon;Kuh, Hyo-Jeong;Lee, Jae-Hwi
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.16 no.3
    • /
    • pp.205-209
    • /
    • 2012
  • The objective of the present study was to establish the method of measurement of hydrogen peroxide and to estimate the anti-oxidative effect of genistein in the skin. UVB induced skin oxidation and anti-oxidative effect of genistein formulations were evaluated by determining levels of hydrogen peroxide. The mechanism involved in the determination of hydrogen peroxide is based on a color reaction between ferric ion ($Fe^{3+}$) and xylenol orange, often called FOX assay and subsequent monitoring of absorbance values of the reactant at 540 nm. The reaction was to some extent pH-dependent and detection sensitivity was greatest at pH 1.75. Genistein liposomal gel demonstrated better anti-oxidative effect with regard to lowering hydrogen peroxide levels elevated by UVB irradiation compared to genistein-suspended gel. A linear relationship has been observed between anti-oxidative effect of genistein and drug deposition in the skin tissue. Genistein liposomal gel resulting in the localization of the drug in the deeper skin led to improved anti-oxidative effect compared to genistein gel. The suggested method for evaluation of oxidation of the skin can be used as a tool to screen effective anti-oxidative agents and their delivery systems acting on the skin.

A Study on Safety, Performance and Clinical effectiveness Test Guideline of Versatile Ophthalmic Laser System (다목적 안과용 레이저 시스템 안전성 성능평가 및 임상적 유효성평가 가이드라인 수립을 위한 연구)

  • Kim, You Rim;Yu, Woo Jin;Park, Ho Joon;Jang, Won Seuk
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.250-259
    • /
    • 2019
  • Ophthalmic Laser System is widely used in Selective Laser Trabeculoplasty of Open Angle Glaucoma and Ocular Hypertension. Versatile ophthalmic laser system is a medical device with technology that checks the condition of the treatment area by irradiating a continuous laser pulse on the treatment area, and monitoring the microbubble reaction caused by the temperature increase of the melanosome through the ultrasonic signal and the optical signal sensor. It performs selective laser treatment without damaging the photoreceptor by controlling the wavelength of the laser when microbubbles are detected. This study aims to suggest a guideline for evaluating safety, performance and clinical effectiveness of Versatile Ophthalmic Laser System in accordance with the growing technology. International Standards, Regulations, and Clinical Trial Protocols were investigated and analyzed for this study. As a result of this study, the safety, performance and clinical effectiveness test guideline for Versatile Ophthalmic Laser System were proposed. This guideline will ensure the safety and efficacy of Medical device, and furthermore it is expected to be able to promote the development of technology development by supporting a clinical trial plan.

Photopolymerization and Properties of PCL-Based Biodegradable Molecularly Imprinted Polymers (PCL 기반 생분해성 분자 날인 고분자의 광중합 및 물성)

  • Kim, Sun-Hui;Lee, Kyung-Soo;Kim, Yong-Hoon;Choi, Woo-Jin;Kim, Beom-Soo;Kim, Eung-Kook;Kim, Dae-Su
    • Polymer(Korea)
    • /
    • v.31 no.2
    • /
    • pp.153-159
    • /
    • 2007
  • Biodegradable molecularly imprinted polymers (MIPs) can be applied in the biomedical area of biosensors, drug delivery, etc. Therefore, in this study, biodegradable theophylline MIPs were synthesized via photopolymerization using a poly $(\varepsilon-caprolactone)$ (PCL) macromer as a cross-linker and their physical properties were investigated. The yield for the synthesis of the PCL macromer with terminal acrylate groups was ca. 78 mol%. The products were characterized by the combination of FT-IR and $^1H-NMR$ spectroscopic analyses. UV/Visible spectroscopic analysis for removing and rebinding theophylline was performed by monitoring the theophylline concentration in the solution. In vitro biodegradation tests of the theophylline MIPs performed in phosphate buffered saline (PBS) solution at $37^{\circ}C$ showed good biodegradability of the MIPs.