• 제목/요약/키워드: biological sample

검색결과 932건 처리시간 0.031초

Determination of Lead in Different Samples by Atomic Absorption Spectrometry after Preconcentration with Dithizone Immobilized on Surfactant-Coated Alumina

  • Dadfarnia, S.;Haji Shabani, A.M.;Dehgan Shirie, H.
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권4호
    • /
    • pp.545-549
    • /
    • 2002
  • A simple and rapid technique for the separation and preconcentration of lead in water and biological samples has been devised. Preconcentrationis based on the depositionof analyte onto a column packed with dithizone immobilized on sodium dodecyl sulfate coated alumina at pH $\geq$ 3. The trapped lead is eluted with 5 mL of 4 M nitric acid and determined by flame atomic absorption spectroscopy. A sample of 1 L, results in a preconcentration factor of 200 and the precision at 20${\mu}g$ $L^{-1}$ is 1.3%(n=8). The procedure is applied to tap water, well water, river water, vegetable extract and milk samples, and accuracy is assessed through recovery experiments and by independent analysis by furnace atomic absorption.

American Pit Bull Terrier메서 파상풍에 대한 임상적 및 미생물학적인 진단 (Clinical and Microbiological Diagnosis of Tetanus in an American Pit Bull Terrier dog)

  • 허은정;박영재;김남수;송희종;채준석
    • 한국임상수의학회지
    • /
    • 제17권2호
    • /
    • pp.459-463
    • /
    • 2000
  • A 3 year-old male American Pit Bull Terrier in Kwang-Ju, Chonnam was admitted to the Teaching Animal Hospital, Chonbuk National University. He showed convulsive spasms of skeletal muscles, raised tail-head, and rigidity of rigidity. Based on these clinical sign\ulcorner tetanus was suspected Hematological test results showed and WBC value (21 ,800/$\mu$l/) with neutrophils (17.877/$\mu$l) and monocytes (1.744/$\mu$l). The blood chemical values ALT (86 IU/L) and AST (119 IU/L) were elevated. Fecal sample from the dog was cultured in anaerobic chamber. A Gram positive, drumstick shaped bacteria was isolated. The bacteria was identified as Clostridium tetani by biological and biochemical tests. The dog was hospitalized in a quiet place where the light was cut off and treated with penicillin G procaine and phenobarbital sodium. The dog made a complete recovery 25 days after treatment. This Is the first report on C. tetani infection of domestic dog in Korea.

  • PDF

Isolation of Polypeptide Fractions from Different Park offered Ginseng

  • Larina, Ludmila;Muranova, T.;Cho, B.G.;Park, H.
    • 고려인삼학회:학술대회논문집
    • /
    • 고려인삼학회 1998년도 Advances in Ginseng Research - Proceedings of the 7th International Symposium on Ginseng -
    • /
    • pp.160-167
    • /
    • 1998
  • Chemical studies of nitrogen compounds of Panax ginseng seem relatively rare, Probably due to the isolation difficulties, subsequently the investigations of biological activities are little. The experimental conditions were established for highly complete extraction of peptides (basic, acidic and neutral) from Panax ginseng. This task was achieved by applying the follow isolation procedure: 1 , the sequential extraction with water, 0.1% TFA in 20% acetonitril and buffer pH 6.5 (water-pyridine-acetic acid 100:3:900) : 2, fractionation by ultrafiltration : 3, n-butanol extraction 4, cation- and anion-exchange chromatography : 5, chromato-electrophoresis. The comparison of red ginseng (xylem Sl pith part) and red ginseng inside white (xylem Sc pith part) was also provided. To analyze the peptide mixture the chromato-electrophoresis method of separation was applied. Optimal conditions for peptides mapping of sample were explored. Our experiments revealed the quantitative difference of peptide between xylem & pith and phloem & cortex part. We have also found the qualitative difference in the composition of polypeptides between normal red ginseng (xylem Sc pith part) and red ginseng inside-white (xylem St pith part)

  • PDF

성게의 초기 발생계를 이용한 인천연안해수 수질평가 (Evaluation of Seawater Quality from Incheon Offshore Using Early Development Systems of A Sea Urchin)

  • 유춘만
    • 한국환경보건학회지
    • /
    • 제35권6호
    • /
    • pp.486-490
    • /
    • 2009
  • In January 2009, the water quality of offshore around the Incheon coast was evaluated by bioassay using early development systems of a sea urchin species, Hemicentrotus pulcherrimus. The results of performing biological evaluations on seawater samples from total of thirteen sites, showed that the formation rates of normal pluteus larva varied from 18% to 71%. In site 5 the seawater sample led to an averaage formation rate of normal larva of 18%, the highest abnormal formation rate hindering the early embryo development of the experimental animal, while that of site 3 averaged 71%, the highest formation rate of normal larva. Seawater samples from site 1, 2, 4, 7, 9, 10, 11 and 12, resulted in average formation rates of normal larva from 33% to 56%, which indicates the developmental damage of early embryos is not severe. Seawater samples from site 5, 6, 8 and 13, resulted in average formation rates of normal larva from 18% to 21% which there was strong damage to the development of early embryos.

간접접촉 심전도 측정용 전극의 주파수 특성 (Frequency Response of the electrode for Indirect-contact ECG)

  • 임용규
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권3호
    • /
    • pp.249-253
    • /
    • 2008
  • The indirect-contact ECG (IDC-ECG) was introduced by a prior study for daily non-intrusive measurements. To improve the signal quality and to extend the application area of IDC-ECG, close study of the frequency characteristics of the IDC-ECG is necessary. In this study, the frequency response of the active electrode for several sample clothes was measured under conditions of actual IDC-ECG measurement with human body. Higher gain in low frequency range than expected by prior study was observed. In addition to it, wide variation in gain according to the cloth type in the low frequency range was observed. Variation in gain caused by moisture variation in the clothes was also observed. This study shows that the parallel R-C connection is proper for electrode model and the resistive factor is influenced by moisture in the clothes. This study is the first that provides the frequency response of the electrode in the actual indirect-contact ECG measurement and it is expected that the results will be helpful to improve the indirect-contact ECG method.

Examination of Cross-calibration Between OSMI and SeaWiFS: Comparison of Ocean Color Products

  • Lee, Sun-Gu;Kim, Yong-Seung
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2002년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.209-215
    • /
    • 2002
  • Much effort has been made in the radiometric calibration of the ocean scanning multispectral imager (OSMI) since after the successful launch of KOMPSAT-1 in 1999. A series of calibration coefficients for OSMI detectors were obtained in collaboration with the NASA Sensor Intercomparison and Merger for Biological and Interdisciplinary (SIMBIOS) project office. In this study, we compare the OSMI level-2 products (e.g., chlorophyll-a concentration) calculated from the NASA cross-calibration coefficients with the SeaWiFS counterparts. Sample study areas are some of diagonostic data sites recommended by the SIMBIOS working group. We will present the preliminary results of this comparative study.

  • PDF

Metabolomic approach for evaluating drug response

  • Jung, Byung-Hwa
    • 한국응용약물학회:학술대회논문집
    • /
    • 한국응용약물학회 2007년도 Proceedings of The Convention
    • /
    • pp.11-15
    • /
    • 2007
  • Metabolomics is an emerging technology which makes it possible to evaluate change of biological system in response to the physiological, environmental alterations. It has advantages in the simplicity and sensitivity to analyze metabolites since the researcher can use cutting edge instrument, such as mass spectrometry and simple sample preparation method compared to genomics or proteomics. Nowadays this technology has been tried in pharmaceutical area to investigate toxicity and efficacy of drug candidates and drugs in preclinical test. The metabolomic applications on the pharmaceutics for early prediction on toxicity and efficacy are described in this presentation. The multivariate analysis to get metabolic fingerprinting and its relations with the physiological changes are investigated with several drugs. Feasibility of metabolomic application for pharmaceutical area would be suggested from those researches.

  • PDF

Micro-Structure Measurement and Imaging Based on Digital Holography

  • Kim, Kyeong-Suk;Jung, Hyun-Chul;Chang, Ho-Seob;Kee, Chang-Doo;Akhter, Naseem
    • 비파괴검사학회지
    • /
    • 제30권3호
    • /
    • pp.257-260
    • /
    • 2010
  • Advancements in the imaging and computing technology have opened the path to digital holography for non-destructive investigations of technical samples, material property measurement, vibration analysis, flow visualization and stress analysis in aerospace industry which has widened the application of digital holography in the above fields. In this paper, we demonstrate the non-destructive investigation and micro-structure measurement application of digital holography to the small particles and a biological sample. This paper gives a brief description of the digital holograms recorded with this system and illustratively demonstrated.

Improved Phosphotyrosine Analysis by TLC and HPLC

  • Song, Young-Me;Yoo, Gyurng-Soo;Lee, Seung-Ki;Choi, Jung-Kap
    • Archives of Pharmacal Research
    • /
    • 제16권2호
    • /
    • pp.99-103
    • /
    • 1993
  • We describe here the conditions of thin layer chromatography (TLC) and high pressures liquid chromatography (HPLC) to improve the analytical method of phosphotyrosine (p-Tyr) in biological sample. TLC was performed on silica plate with the mixture of propanol and water (2.1 : 1 v/v) as a mobile phase and $R_1$ values were 0.42, 0.39 and 0.33 for phosphotyrosine, phosphothreonine and phosphoserine, respectively. HPLC was performed on $NH_2$ column with a mobile phase of potassium biphosphate solution by UV deterction at 192 nm. The optimum condition of HPLC was obtained at 0.01 M, pH 4.5 with a clear separation within 12 min. These procedures have been applied to the analysis of phosphotyrosine obtained from tyrosine-phosphorylated enolase. Both TLC and HPLC methods were suitable to analyze tyrosine-phosphorylated protein without being affected by contaminants from hydrolysates.

  • PDF

Examination of Cross-calibration Between OSMI and SeaWiFS: Comparison of Ocean Color Products

  • Kim, Yong-Seung;Lee, Sun-Gu
    • 대한원격탐사학회지
    • /
    • 제19권3호
    • /
    • pp.201-208
    • /
    • 2003
  • Much effort has been made in the radiometric calibration of the ocean scanning multispectral imager (OSMI) since after the successful launch of KOMPSAT-1 in 1999. A series of calibration coefficients for OSMI detectors were obtained in collaboration with the NASA Sensor Intercomparison and Merger for Biological and Interdisciplinary (SIMBIOS) project office. In this study, we ompare the OSMI level-2 products (e.g., chorophyll-a concentration) calculated from the NASA cross-calibration coefficients with the SeaWiFS counterparts. Sample study areas are some of diagonostic data sites recommended by the SIMBIOS working group. Results of this study show that the OSMl-derived chlorophyll-a concentration agrees well with the SeaWiFS counterpart in Case 1 water; however, differences become larger in Case 2 water.