• Title/Summary/Keyword: biological activated carbon

Search Result 221, Processing Time 0.035 seconds

Electrochemical Properties of Activated Carbon Supecapacitor Containing Poly(acrylonitrile) Nonwoven Separator Coated by a Hydrogel Polymer Electrolyte (Poly(acrylonitrile) 부직포 분리막에 코팅된 하이드로겔 고분자 전해질을 포함하는 활성탄 수퍼커패시터 특성)

  • Latifatu, Mohammed;Ko, Jang Myoun;Lee, Young-Gi;Kim, Kwang Man;Jo, Jeongdai;Jang, Yunseok;Yoo, Jung Joon;Kim, Jong Huy
    • Korean Chemical Engineering Research
    • /
    • v.51 no.5
    • /
    • pp.550-555
    • /
    • 2013
  • A hydrogel electrolyte consisting of potassium poly(acrylate) (PAAK) (3 wt%) in 6 M KOH aqueous solution is coated on poly(acrylonitrile) nonwoven separator to examine high-rate characteristics of activated carbon supercapacitor adopting the separator. The hydrogel is homogeneously coated on the surface pores of the nonwoven separator. The electrolyte uptake of the PAAK hydrogel maintains for 24 days higher than 230% and the coated separator shows slightly lower ionic conductivity ($2.9{\times}10^{-2}Scm^{-1}$) than that ($3.6{\times}10^{-2}Scm^{-1}$) of using 6 M KOH only. The activated carbon supercapacitor adopting the coated separator shows a specific capacitance higher than $27Fg^{-1}$ at $1000mVs^{-1}$ and a retention ratio higher than 97% after the 1000th cycle. This is due to strong interfacial contact of coated hydrogel electrolyte between the activated carbon electrode and the nonwoven separator.

Removal of NOM Using Biological Rope Media Sedimentation Tank (로프형 미생물 담체 침전조를 이용한 상수원수중의 NOM 제거)

  • 심상준;강연석;김우식;박대원
    • KSBB Journal
    • /
    • v.16 no.4
    • /
    • pp.332-336
    • /
    • 2001
  • This paper is intended as an application of the biological rope media sedimentation tank using biodegradability of BAC(Biological activated carbon) to the drinking water treatment system for the removal of NOM. The removal of DOC(Dissolved organic carbon), UV absorbance(UV$\_$254/), and turbidity were evaluated under various operation condition of a biological rope media sedimentation tank such as raw water-media process (Media 1), ozonation-media process (Media 2), and ozonation-coagulation/sedimentation-media process (Media 3). The raw water had DOC concentration of 1.3∼3.4 mg/L, UV$\_$254/ of 0.027∼0.039 cm$\^$-1/, and turbidity of 0.3∼4.5 NTU, respectively. The average DOC concentration were 2.2 mg/L in media 1, 1.8 mg/L in media 2, and 1.3 mg/l in media 3 from raw water, respectively. On the other hand, the DOC concentration in conventional sedimentation tank was 1.5 mg/l. Higher removal of the DOC was noted in media 3 than media 1 and media 2. The UV$\_$254/ of the treated water were 0.037 cm$\^$-1/ in media 1, 0.027 cm$\^$-1/ in media 2, and 0.014 cm$\^$-1/ in media 3 from raw water, respectively The UV$\_$254/ in conventional sedimentation tank was 0.014 cm$\^$-1/ which is similar to that of media 3. Average turbidity of the treated water was 1.1 NTU in media 1, 0.9 NTU in media 2, and 0.5 NTU in media 3, respectively. It is expected that the biological rope media sedimentation tank is a good alternative over the conventional sedimentation process from these results.

  • PDF

Sensitivity Analysis and Parameter Estimation of Activated Sludge Model Using Weighted Effluent Quality Index (가중유출수질지표를 이용한 활성오니공정모델의 민감도 분석과 매개변수 보정)

  • Lee, Won-Young;Kim, Min-Han;Kim, Young-Whang;Lee, In-Beum;Yoo, Chang-Kyoo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.11
    • /
    • pp.1174-1179
    • /
    • 2008
  • Many modeling and calibration methods have been developed to analyze and design the biological wastewater treatment process. For the systematic use of activated sludge model (ASM) in a real treatment process, a most important step in this usage is a calibration which can find a key parameter set of ASM, which depends on the microorganism communities and the process conditions of the plants. In this paper, a standardized calibration protocol of the ASM model is developed. First, a weighted effluent quality index(WEQI) is suggested far a calibration protocol. Second, the most sensitive parameter set is determined by a sensitive analysis based on WEQI and then a parameter optimization method are used for a systematic calibration of key parameters. The proposed method is applied to a calibration problems of the single carbon removal process. The results of the sensitivity analysis and parameter estimation based on a WEQI shows a quite reasonable parameter set and precisely estimated parameters, which can improve the quality and the efficiency of the modeling and the prediction of ASM model. Moreover, it can be used for a calibration scheme of other biological processes, such as sequence batch reactor, anaerobic digestion process with a dedicated methodology.

Application of MBR process for the treatment of RO concentrate from wastewater reuse process (하수재이용 공정에서 발생되는 RO농축수 처리를 위한 MBR 공정 적용)

  • Lee, Do-Hun;Jang, Hyun-Ji;Kim, Han-Seung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.3
    • /
    • pp.339-349
    • /
    • 2013
  • Biological treatment of RO concentrate from wastewater reuse process is known to be very difficult due to its high concentration of non-degradable organics and salt ions such as chloride, nitrate and phosphate. In this research, the treatment performance of MBR was examined using RO concentrate mixed with raw wastewater as the influent of MBR. Addition of PAC (powdered activated carbon) to MBR was also evaluated in order to enhance the treatment performance and stability. The performance of MBR for treating only RO concentrate decreased gradually although external carbon source was added. The average removal performance of MBR with and without PAC decreased from 99.1 %(98.8 %) to 94.9 %(91.4 %) for COD, 81.3 %(80.3 %) to 42.0 %(41.9 %) for T-N and 57.3(55.0 %) to 30.0 %(21.0 %) for T-P with the increase of RO concentrate mixing rate of 0 % to 20 % in the feed water. Addition of PAC showed positive effect on the performance of MBR for the removal of COD and phosphorus in case that the ratio of RO concentrate to feed water increased.

Performances of Intermittently Aerated and Dynamic Flow Activated Sludge Process (2단간헐폭기 및 유로변경 간헐폭기 활성슬러지 시스템을 이용한 도시하수 처리)

  • 원성연;민경국;이상일
    • Journal of environmental and Sanitary engineering
    • /
    • v.13 no.1
    • /
    • pp.26-31
    • /
    • 1998
  • Removal of nitrogen and phosphate in wastewater is concerned to important for the prevention of eutrophication in receiving water and lake. Conventional activated sludge system designed for organics removal can be retrofitted only by modification of aeration basin to maintain anaerobic and aerobic state. Biological nutrient removal processes(BNR) such as Bardenpho, A$^{2}$/O, UCT, VIP were generally used for the treatment of wastewater. However these BNR processes used in large scale WWTP were not suitable in small scale WWTP(i.e., package type WWTP) due to relatively large fluctuation of flow rate and concentration of pollutants. The purpose of this research was to develop the compact, effective and economical package type WWTP for the removals of carbon and nitrogen in small scale wastewater. Intermittently aerated activated sludge system (IADFAS) were investigated for removal of nitrogen in both domestic wastewater, Bardenpho process was also evaluated. Nitrogen removal of IAAS, IADFAS, Bardenpho were 75, 77 and 67%, respectively.

  • PDF

Electricity Generation Coupled with Wastewater Treatment Using a Microbial Fuel Cell Composed of a Modified Cathode with a Ceramic Membrane and Cellulose Acetate Film

  • Seo, Ha-Na;Lee, Woo-Jin;Hwang, Tae-Sik;Park, Doo-Hyun
    • Journal of Microbiology and Biotechnology
    • /
    • v.19 no.9
    • /
    • pp.1019-1027
    • /
    • 2009
  • A noncompartmented microbial fuel cell (NCMFC) composed of a Mn(IV)-carbon plate and a Fe(III)-carbon plate was used for electricity generation from organic wastewater without consumption of external energy. The Fe(III)-carbon plate, coated with a porous ceramic membrane and a semipermeable cellulose acetate film, was used as a cathode, which substituted for the catholyte and cathode. The Mn(IV)-carbon plate was used as an anode without a membrane or film coating. A solar cell connected to the NCMFC activated electricity generation and bacterial consumption of organic matter contained in the wastewater. More than 99% of the organic matter was biochemically oxidized during wastewater flow through the four NCMFC units. A predominant bacterium isolated from the anode surface in both the conventional and the solar cell-linked NCMFC was found to be more than 99% similar to a Mn(II)-oxidizing bacterium and Burkeholderia sp., based on 16S rDNA sequence analysis. The isolate reacted electrochemically with the Mn(IV)-modified anode and produced electricity in the NCMFC. After 90 days of incubation, a bacterial species that was enriched on the Mn(IV)-modified anode surface in all of the NCMFC units was found to be very similar to the initially isolated predominant species by comparing 16S rDNA sequences.

Effects of the Fluorination of Activated Carbons on the Chromium Ion Adsorption (활성탄소의 불소화가 크롬이온 흡착에 미치는 영향)

  • Kim, Min-Ji;Jung, Min-Jung;Choi, Suk Soon;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.26 no.1
    • /
    • pp.92-98
    • /
    • 2015
  • In this study, phenol-based activated carbons (ACs) were fluorinated at various fluorine partial pressures (0.01~0.03 MPa) and the $Cr^{6+}$ ion adsorption of fluorinated ACs was investigated. According to BET and XPS results, the specific surface area and total pore volume of fluorinated ACs increased by 24.7 and 55.8%, respectively, and fluorine functional groups were introduced to AC surface. The most optimized condition of $Cr^{6+}$ ion adsorption was confirmed at the fluorine partial pressure of 0.02 MPa. And also the removal efficiency of $Cr^{6+}$ ion was up to 98% at 300 mg/L of the initial concentration, and these results showed an approximately three-fold increase compared to that of using untreated ACs. Furthermore, the $Cr^{6+}$ ion adsorption of fluorinated ACs was completed in less than 30 min in contrast with untreated ACs, which was expected to be an increase of the affinity between $Cr^{6+}$ ions and ACs surfaces by fluorination.

Evaluation of Influence Factors for Determination of Proper Backwashing Time of Biological Activated Carbon (BAC) Process in Drinking Water Treatment Process (정수처리용 활성탄 공정의 적정 역세척 시점 선정을 위한 영향인자들 평가)

  • Kim, Sang-Goo;Park, Hong-Gi;Son, Hee-Jong;Yoom, Hoon-Sik;Ryu, Dong-Choon
    • Journal of Environmental Science International
    • /
    • v.24 no.12
    • /
    • pp.1551-1558
    • /
    • 2015
  • In Korea, many drinking water treatment plants (DWTPs) have introduced and are going to introduce biological activated carbon (BAC) process to treated dissolved organic matter (DOM) in water which are difficult to control by conventional water treatment processes. Even though more decade have passed since introduced BAC in Korea, most of BAC operating method was followed to the modified sand filter operating manuals. In case of BAC backwashing, many DWTPs set the periods of backwashing about 3~5 days. In this study, we have collected data to set the proper BAC backwashing periods from both pilot-plant and real DWTPs. We had measured heterotrophic plate count (HPC), turbidity, water temperature, dissolved organic carbon (DOC) and headloss from just after backwashing to the next backwashing time for two years. Considering water quality factors, the BAC run time from backwashing to the next backwashing could extend more 30 days without water quality deterioration if the head loss do not reach the limited level which depends on each BAC facilities' condition. It means the BAC treated water could be saved in the proportion of extended the backwashing period to the existing backwashing period.

Analysis of Attached Bacterial Community of Biological Activated Carbon Process Using FISH (FISH 기법을 이용한 생물활성탄 공정에서의 운전기간별 부착 박테리아 군집변화 분석)

  • Son, Hyeng-Sik;Son, Hee-Jong;Park, Geun-Tae;Lee, Sang-Joon
    • Journal of Environmental Science International
    • /
    • v.22 no.1
    • /
    • pp.25-35
    • /
    • 2013
  • The concentration of organic compounds was analyzed at each step of BAC process though $BDOC_{total/rapid/slow}$. Further, bacteria communities and biomass concentrations measured FISH and ATP methods were analyzed. The bed volume (BV) of steady state is different from that of based on assessment of organic compounds removal. Bed volumes in DOC, $BDOC_{rapid}$ and $BDOC_{total/slow}$ removal at steady state were around 27,500 (185.8 day), 15,000 (101.4 day) and 32,000 (216.2 day), respectively. A biomass didn't change after the bed volume reached 22,500 (152.0 day) according to analyzing ATP concentration of bacteria. The concentration of ATP was 2.14 ${\mu}g/g$ in BV 22,500 (152.0 day). The total bacterial number was $4.01{\pm}0.4{\times}10^7$ cells/g at the bed volume 1,150 (7.8 day) (the initial operation) and the number of bacteria was $9.27{\pm}0.2{\times}10^9$ at the bed volume 58,560 395.7 day) that increased more than 200 times. Bacterial uptrend was reduced and bacterial communities were stabilized since BV 18,720 (126.5 day). When BV were 1,150 (7.8 day), 8,916 (60.2 day), 18,720 (126.5 day), 31,005 (209.5 day), 49,632 (335.3 day), 58,560 (395.7 day), a proportion of total bacteria for the Eubacteria were 60.1%, 66.0%, 78.4%, 82.0%, 81.3% respectively. ${\gamma}$-Proteobacteria group was the most population throughout the entire range. The correlation coefficient ($r^2$) between Eubacteria biomass and ATP concentration was 0.9448.

Applicability Evaluation of Two-stages and Dual Media Filtration System by the Small-scale Pilot Plant (이단이층 복합여과시스템의 소규모 파일롯 플랜트 적용성 평가)

  • Woo, Dal-Sik;Song, Si-Byum;Hwang, Byung-Gi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.4
    • /
    • pp.857-864
    • /
    • 2009
  • This study aimed at developing the two stage and dual filtration system. It has a sand + activated carbon layer above the underdrain system and a sand layer above the middledrain system for pretreatment. When retrofitting an old filter bed or designing a new one, this technology can substitute the existing sand filter bed without requiring a new site. In order to extend the filtering duration, the upper layer of the filter bed consists of the rapid sand filtration with large particles which pre-treats and removes coarse particles and turbidity matters. The middle layer has biological activated carbon(BAC) and granular activated carbon(GAC) to eliminate dissolved organic matters, disinfection by-products precursors etc. The lower layer consists of the sand filtration for the post filtering mode. In this study, a pilot plant of two stage and dual filtration system was operated for 4 months in the S water treatment plant in Kyounggi-Do. The stability of turbidity was maintained below 1NTU. The TOC, THMFP and HAAFP were removed about 90% by two stage and dual filtration system, which is almost 2 times higher than S WTP. From analysis result of HPC along the depth of activated carbon + sand layer at 2nd stage, microorganism was mostly not detected, however, increment of HPC was shown as it becomes deeper. It indicates that growth of microorganism is occurred at activated carbon layer.