• Title/Summary/Keyword: bias reference

Search Result 213, Processing Time 0.022 seconds

A Low Jitter Delay-Locked Loop for Local Clock Skew Compensation (로컬 클록 스큐 보상을 위한 낮은 지터 성능의 지연 고정 루프)

  • Jung, Chae-Young;Lee, Won-Young
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.2
    • /
    • pp.309-316
    • /
    • 2019
  • In this paper, a low-jitter delay-locked loop that compensates for local clock skew is presented. The proposed DLL consists of a phase splitter, a phase detector(PD), a charge pump, a bias generator, a voltage-controlled delay line(VCDL), and a level converter. The VCDL uses self-biased delay cells using current mode logic(CML) to have insensitive characteristics to temperature and supply noises. The phase splitter generates two reference clocks which are used as the differential inputs of the VCDL. The PD uses the only single clock from the phase splitter because the PD in the proposed circuit uses CMOS logic that consumes less power compared to CML. Therefore, the output of the VCDL is also converted to the rail-to-rail signal by the level converter for the PD as well as the local clock distribution circuit. The proposed circuit has been designed with a $0.13-{\mu}m$ CMOS process. A global CLK with a frequency of 1-GHz is externally applied to the circuit. As a result, after about 19 cycles, the proposed DLL is locked at a point that the control voltage is 597.83mV with the jitter of 1.05ps.

Application of Integrated Modelling Framework Consisted of Delft3D and HABITAT for Habitat Suitability Assessment (생물서식지 적합성 평가를 위한 Delft3D와 HABITAT 모델의 연계 적용)

  • Lim, Hyejung;Na, Eun Hye;Jeon, Hyeong Cheol;Song, Hojin;Yoo, Hojun;Hwang, Soon Hong;Ryu, Hui-Seong
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.3
    • /
    • pp.217-228
    • /
    • 2021
  • This paper discusses a methodology where an integrated modelling framework is used to quantify the risk derived from anthropic activities on habitats and species. To achieve this purpose, a tool comprising the Delft3D and HABITAT model, was applied in the Yeongsan river. Delft3D effectively simulated the operational condition and flow of weirs in river. In accuracy evaluation of the Delft3D-FLOW, the Bias, Pbias, Mean Absolute Error (MAE), Nash-Sutcliffe Efficiency (NSE), and Index of Agreement (IOA) were used, and the result was evaluated as grade above 'Satisfactory'. The HABITAT calculated Habitat Suitability Value (HSV) for the following eight species: mammal, fish, aquatic plant, and benthic macroinvertebrate. An Area was defined as a suitable habitat if the HSV was larger than 0.5. HABITAT was judged accurately by measuring the Correct Classification rate (CCR) and the area under the ROC curve (AUC). For benthic macroinvertebrate, the CCR and AUC were 77% and 0.834, respectively, at thresholds of 0.017 and 4 inds/m2 for HSV and individuals per unit area. This meant that the HABITAT model accurately predicted the appearance of the benthic macroinvertebrates by approximately 77% and that the probability of false alarms was also very low. As a result of evaluating the suitability of habitats, in the Yeongsan river, if the annual "lowest level" (Seungchon weir: 2.5 EL.m/ Juksan weir: -1.35 EL.m) was maintained, the average habitat improvement effect of 6.5%P compared to the 'reference' scenario was predicted. Consequently, it was demonstrated that the integrated modelling framework for habitat suitability assessment is able to support the remedy aquatic ecological management.

Validation of a physical activity classification table in Korean adults and elderly using a doubly labeled water method (한국 성인과 노인을 대상으로 이중표식수법을 이용한 신체활동분류표 타당도 평가)

  • Hye-Ji Han ;Ha-Yeon Jun;Jonghoon Park;Kazuko Ishikawa-Takata;Eun-Kyung Kim
    • Journal of Nutrition and Health
    • /
    • v.56 no.4
    • /
    • pp.391-403
    • /
    • 2023
  • Purpose: This study evaluated the validity of a physical activity classification table (PACT) based on total energy expenditure (TEE) and physical activity level (PAL) measured using the doubly labeled water (DLW) method in Korean adults and the elderly. Methods: A total of 141 (male 70, female 71) adults and elderly were included. The reference standards TEEDLW, PALDLW were measured over a 14-day period using DLW. A 24-hour physical activity diary was kept for three days (two days during the week and one day on the weekend). PALPACT was calculated by classifying the activity type and intensity using the PACT. PALPACT was multiplied by resting energy expenditure measured by indirect calorimetry to estimate TEEPACT. Results: The mean age of the study participants was 50.5 ± 18.8 years, and the mean body mass index was 23.4 ± 3.3 kg/m2. A comparison of TEEDLW and TEEPACT by sex and age showed no significant differences. The bias, the difference between TEEDLW and TEEPACT, was male 17.3 kcal/day and female -4.5 kcal/day. The percentage of accurate predictions (values within ± 10% of the TEEDLW) of TEEPACT was 58.6% in males and 54.9% in females, with the highest prediction values in the age group 40-64 years (70.9%) in males and over 65 years (73.9%) in females. The spearman correlation coefficient (r) between TEEPACT and TEEDLW was 0.769, indicating a significant positive correlation (p < 0.001). Conclusion: In this study, the use of a new PACT for calculating TEE and PAL was evaluated as valid. A web version of the software program and a smartphone application need to be developed using PACT to make it easier to apply for research purposes.

A 10b 200MS/s 75.6mW $0.76mm^2$ 65nm CMOS Pipeline ADC for HDTV Applications (HDTV 응용을 위한 10비트 200MS/s 75.6mW $0.76mm^2$ 65nm CMOS 파이프라인 A/D 변환기)

  • Park, Beom-Soo;Kim, Young-Ju;Park, Seung-Jae;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.3
    • /
    • pp.60-68
    • /
    • 2009
  • This work proposes a 10b 200MS/s 65nm CMOS ADC for high-definition video systems such as HDTV requiring high resolution and fast operating speed simultaneously. The proposed ADC employs a four-step pipeline architecture to minimize power consumption and chip area. The input SHA based on four capacitors reduces the output signal range from $1.4V_{p-p}$ to $1.0V_{p-p}$ considering high input signal levels at a low supply voltage of 1.2V. The proposed three-stage amplifiers in the input SHA and MDAC1 overcome the low output resistance problem as commonly observed in a 65nm CMOS process. The proposed multipath frequency-compensation technique enables the conventional RNMC based three-stage amplifiers to achieve a stable operation at a high sampling rate of 200MS/s. The conventional switched-bias power-reduction technique in the sub-ranging flash ADCs further reduces power consumption while the reference generator integrated on chip with optional off-chip reference voltages allows versatile system a locations. The prototype ADC in a 65nm CMOS technology demonstrates a measured DNL and INL within 0.19LSB and 0.61LSB, respectively. The ADC shows a maximum SNDR of 54.BdB and 52.4dB and a maximum SFDR of 72.9dB and 64.8dB at 150MS/S and 200MS/s, respectively. The proposed ADC occupies an active die area of $0.76mm^2$ and consumes 75.6mW at a 1.2V supply voltage.

Qualitative and quantitative PCR detection of insect-resistant genetically modified rice Agb0101 developed in korea (해충저항성 유전자변형 벼 Agb0101에 대한 PCR 검정)

  • Shin, Kong-Sik;Lee, Jin-Hyoung;Lim, Myung-Ho;Woo, Hee-Jong;Qin, Yang;Suh, Seok-Cheol;Kweon, Soon-Jong;Cho, Hyun-Suk
    • Journal of Plant Biotechnology
    • /
    • v.40 no.1
    • /
    • pp.18-26
    • /
    • 2013
  • Genetically modified (GM) rice Agb0101, which expresses the insecticidal toxin modified cry1Ac (mcry1Ac1) gene, was developed by the Rural Development Administration in Korea. To monitor the probable release of Agb0101 in the future, it is necessary to develop a reliable detection method. Here, we developed the PCR detection method for monitoring and tracing of GM rice. The primer pair (RBEgh-1/-2) from a starch branching enzyme (RBE4) gene was designed as an endogenous reference, giving rise to an expected PCR amplicon of 101 bp. For the qualitative PCR detection, construct- and event-specific primers were designed on the basis of integration sequence of T-DNA. Event-specific PCRs amplified specifically 5'- or 3'-junction region spanning the native genome DNA and the integrated gene construct, while none of amplified product was shown on crops, rice varieties, and other insect-resistant transgenic rice lines. The event-specific real-time PCR method was performed using TaqMan probe and plasmid pRBECrR containing both rice endogenous gene RBE4 sequence and 5'-junction sequence as the reference molecule. The absolute limit of quantification (LOQ) of real-time PCR was established with around 10 copies for one plasmid molecule pRBECrR. Thereafter, the different amounts of transgenic rice (1, 3, 5, and 10%, respectively) were quantified by using the established real-time PCR method, with a range below 19.55% of the accuracy expressed as bias, 0.06-0.40 of standard deviation (SD) and 3.80-7.01% of relative standard deviations (RSD), respectively. These results indicate that the qualitative and quantitative PCR methods could be used effectively to detect the event Agb0101 in monitoring and traceability.

Semi-Quantitative Analysis for Determining the Optimal Threshold Value on CT to Measure the Solid Portion of Pulmonary Subsolid Nodules (폐의 아고형결절에서 침습적 병소를 검출하기 위한 반-정량 분석을 통한 최적의 CT 임계 값 결정)

  • Sunyong Lee;Da Hyun Lee;Jae Ho Lee;Sungsoo Lee;Kyunghwa Han;Chul Hwan Park;Tae Hoon Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.3
    • /
    • pp.670-681
    • /
    • 2021
  • Purpose This study aimed to investigate the optimal threshold value in Hounsfield units (HU) on CT to detect the solid components of pulmonary subsolid nodules using pathologic invasive foci as reference. Materials and Methods Thin-section non-enhanced chest CT scans of 25 patients with pathologically confirmed minimally invasive adenocarcinoma were retrospectively reviewed. On CT images, the solid portion was defined as the area with higher attenuation than various HU thresholds ranging from -600 to -100 HU in 50-HU intervals. The solid portion was measured as the largest diameter on axial images and as the maximum diameter on multiplanar reconstruction images. A linear mixed model was used to evaluate bias in each threshold by using the pathological size of invasive foci as reference. Results At a threshold of -400 HU, the biases were lowest between the largest/maximum diameter of the solid portion of subsolid nodule and the size of invasive foci of the pathological specimen, with 0.388 and -0.0176, respectively. They showed insignificant difference (p = 0.2682, p = 0.963, respectively) at a threshold of -400 HU. Conclusion For quantitative analysis, -400 HU may be the optimal threshold to define the solid portion of subsolid nodules as a surrogate marker of invasive foci.

Long-term Efficacy of S-1 Monotherapy or Capecitabine Plus Oxaliplatin as Adjuvant Chemotherapy for Patients with Stage II or III Gastric Cancer after Curative Gastrectomy: a Propensity Score-Matched Multicenter Cohort Study

  • Lee, Chang Min;Yoo, Moon-Won;Son, Young-Gil;Oh, Sung Jin;Kim, Jong-Han;Kim, Hyoung-Il;Park, Joong-Min;Hur, Hoon;Jee, Ye Seob;Hwang, Sun-Hwi;Jin, Sung-Ho;Lee, Sang Eok;Park, Ji-Ho;Seo, Kyung Won;Park, Sungsoo;Kim, Chang Hyun;Jeong, In Ho;Lee, Han Hong;Choi, Sung Il;Lee, Sang-Il;Kim, Chan Young;Kim, In-Hwan;Son, Myoung-Won;Pak, Kyung Ho;Kim, Sungsoo;Lee, Moon-Soo;Min, Jae-Seok
    • Journal of Gastric Cancer
    • /
    • v.20 no.2
    • /
    • pp.152-164
    • /
    • 2020
  • Purpose: To compare long-term disease-free survival (DFS) between patients receiving tegafur/gimeracil/oteracil (S-1) or capecitabine plus oxaliplatin (CAPOX) adjuvant chemotherapy (AC) for gastric cancer (GC). Materials and Methods: This retrospective multicenter observational study enrolled 983 patients who underwent curative gastrectomy with consecutive AC with S-1 or CAPOX for stage II or III GC at 27 hospitals in Korea between February 2012 and December 2013. We conducted propensity score matching to reduce selection bias. Long-term oncologic outcomes, including DFS rate over 5 years (over-5yr DFS), were analyzed postoperatively. Results: The median and longest follow-up period were 59.0 and 87.6 months, respectively. DFS rate did not differ between patients who received S-1 and CAPOX for pathologic stage II (P=0.677) and stage III (P=0.899) GC. Moreover, hazard ratio (HR) for recurrence did not differ significantly between S-1 and CAPOX (reference) in stage II (HR, 1.846; 95% confidence interval [CI], 0.693-4.919; P=0.220) and stage III (HR, 0.942; 95% CI, 0.664-1.337; P=0.738) GC. After adjustment for significance in multivariate analysis, pT (4 vs. 1) (HR, 11.667; 95% CI, 1.595-85.351; P=0.016), pN stage (0 vs. 3) (HR, 2.788; 95% CI, 1.502-5.174; P=0.001), and completion of planned chemotherapy (HR, 2.213; 95% CI, 1.618-3.028; P<0.001) were determined as independent prognostic factors for DFS. Conclusions: S-1 and CAPOX AC regimens did not show significant difference in over-5yr DFS after curative gastrectomy in patients with stage II or III GC. The pT, pN stage, and completion of planned chemotherapy were prognostic factors for GC recurrence.

A Study on the Reflective Property of Trends in Fashion Shows - Focused on Three Designing Factor of the Silhouette, the Detail, the Color and the Fashion Image - (패션쇼의 트렌드 반영성(反映性)에 관(關)한 연구(硏究) - 실루엣, 디테일, 색상(色相), 패션 이미지 등(等) 4가지 디자인 요소(要素)를 중심(中心)으로 -)

  • Lee, Myung-Hee
    • Journal of Fashion Business
    • /
    • v.3 no.4
    • /
    • pp.147-160
    • /
    • 1999
  • This paper is intended to compare and analyze the fashion trends that were introduced in the recent shows, held abroad and in Korea, so as to investigate how well the designers in Taegu and Kyungbuk (TK) area are keeping up with the international vogue. The research has done, analyzing Pret-a-Porter in Paris and the three events held in the TK area in 1997 -The Taegu Collection, Kyungbuk Fashion Festival and Textile & Apparel Fair and using reference pictures and documentary records. In order to investigate the trends the research is divided by four groups which are the silhouette, the detail, the color and the Fashion image and has done with the help of three postgraduate students. The results are as follows. 1. The Silhouette The slim-line has the greatest importance in the silhouette analysis of the recent collections. Like Elongated and Fit & Flare, tight-fitting and female-line were also appeared quite a lot. Compared with foreign collection, Korean collections put the bigger importance on the slim-line. 2. The Detail The printings, using paintings and plant-logos had the large portion of the accessories in both foreign and Korean collections. Draw string and wrap style were also presented a lot. Especially, at the Korean collections, layerd, corsage, and craft accent were emphasized, too. As for the necklines the similarity was found over the four events considering. Camisole neckline and halter neck were presented the most, and bared top, Vneckline, boat and low-neck which can highlight the feminity were often appeared as well. Considering collars, tailored and peaked collars which are frequently used for the jackets, were usually shown at the collections. Like convertable, shirts, wing and Italian collar, the collars that can be applied for the sports wears were presented a lot. Virtually no variation of design was found in the sleeve analysis. While set-in-sleeve and sleeveless were found commonly, not so many ornaments were added to the sleeves. The ankle and knee length for the pants and skirts were common. Furthermore, including the micro-mini, showing extremely feminine style the mini-style had the 20% portion of the skirt-length. Unbalanced lengths, using bias-cut were presented quite a lot on the runways. Deep slit skirts, wide pants and irregular hem skirts were in vogue. On the runways of Paris, more than 21% of the design was the burmuda pants. 3. The Color Red and Blue were in vogue in the four collections considering. Sometimes, yellowish was combined in Korean collections. Black and pale tone were appeared to be in fashion also with light grayish, moderate and deep tone. 4. The Fashion image As for the fashion image, feminine-decorative trend amounted to the large percentage in korean collections. At the foreign collection feminine-decorative trend and feminine trend were predominant, then mannish trend and simple trend were apeared equally. The research shows that TK area and foreign collections are fairy similar, which means that the designers in TK area have been making their efforts to satisfy the clients who have the international minds. However, compared with foreign collections, TK collections were apprered to be strongly inclined to only a few trends. Consequently the season trends are not as diverse as the foreign trends, which cannot satisfy the fashion taste of the clients in TK area. The local designers should know the tendency and the taste of the clients and make the more efforts to read local clients' mind.

  • PDF

Consideration of density matching technique of the plate type direct radiologic image system and the conventional X-ray film;first step for the subtraction (Ektaspeed plus 필름을 이용한 일반 방사선시스템과 Digora를 이용한 디지탈 영상시스템의 밀도변화 비교연구)

  • So, Sung-Soo;Noh, Hyeun-Soo;Kim, Chang-Sung;Choi, Seong-Ho;Kim, Kee-Deog;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.1
    • /
    • pp.199-211
    • /
    • 2002
  • Digital substraction technique and computer-assisted densitometirc analysis detect minor change in bone density and thus increase the diagnostic accuracy. This advantage as well as high sensitivity and objectivity which precludes human bias have drawn interest in radiologic research area. The objectives of this study are to verify if Radiographic density can be recognized in linear pattern when density profile of standard periapical radiograph with the aluminium stepwedge as the reference, was investigated under varies circumstances which can be encountered in clinical situations, and in addition to that to obtain mutual relationship between the existing standard radiographic system, and future digital image systems, by confirming the corelationship between the standard radiograph and Digora system which is a digital image system currently being used. In order to make quantitative analysis of the bone tissue, digital image system which uses high resolution automatic slide scanner as an input device, and Digora system were compared and analyzed using multifunctional program, Brain3dsp. The following conclusions were obtained. 1. Under common clinical situation that is 70kVp, 0.2 sec., and focal distance 10cm, Al-Equivalent image equation was found to be Y=11.21X+46.62 $r^2=0.9898$ in standard radiographic system, and Y=12.68X+74.59, $r^2=0.9528$ in Digora system, and linear relation was confirmed in both the systems. 2. In standard radiographic system, when all conditions were maintained the same except for the condition of developing solution, Al-Equivalent image equation was Y=10.07X+41.64, $r^2=0.9861$ which shows high corelationship. 3. When all conditions were maintained the same except for the Kilovoltage peak, linear relationship was still maintained under 60kVp, and Al-Equivalent image equation was Y=14.60X+68.86, $r^2=0.9886$ in the standard radiograhic system, and Y=13.90X+80.68, $r^2=0.9238$ in Digora system. 4. When all conditions were maintained the same except for the exposure time which was varied from 0.01 sec. to 0.8 sec., Al-Equivalent image equation was found to be linear in both the standard radiographic system and Digora system. The R-square was distributed from 0.9188 to 0.9900, and in general, standard radiographic system showed higher R-square than Digora system. 5. When all conditions were maintained the same except for the focal distance which was varied from 5cm to 30cm, Al-Equivalent image equation was found to be linear in both the standard radiographic system and Digora system. The R-square was distributed from 0.9463 to 0.9925, and the standard radiographic system had the tendency to show higher R-square in shorter focal distances.

1-month Prediction on Rice Harvest Date in South Korea Based on Dynamically Downscaled Temperature (역학적 규모축소 기온을 이용한 남한지역 벼 수확일 1개월 예측)

  • Jina Hur;Eun-Soon Im;Subin Ha;Yong-Seok Kim;Eung-Sup Kim;Joonlee Lee;Sera Jo;Kyo-Moon Shim;Min-Gu Kang
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.25 no.4
    • /
    • pp.267-275
    • /
    • 2023
  • This study predicted rice harvest date in South Korea using 11-year (2012-2022) hindcasts based on dynamically downscaled 2m air temperature at subseasonal (1-month lead) timescale. To obtain high (5 km) resolution meteorological information over South Korea, global prediction obtained from the NOAA Climate Forecast System (CFSv2) is dynamically downscaled using the Weather Research and Forecasting (WRF) double-nested modeling system. To estimate rice harvest date, the growing degree days (GDD) is used, which accumulated the daily temperature from the seeding date (1 Jan.) to the reference temperature (1400℃ + 55 days) for harvest. In terms of the maximum (minimum) temperatures, the hindcasts tends to have a cold bias of about 1. 2℃ (0. 1℃) for the rice growth period (May to October) compared to the observation. The harvest date derived from hindcasts (DOY 289) well simulates one from observation (DOY 280), despite a margin of 9 days. The study shows the possibility of obtaining the detailed predictive information for rice harvest date over South Korea based on the dynamical downscaling method.