• Title/Summary/Keyword: bending test of beam

Search Result 340, Processing Time 0.035 seconds

A Study on the Bending and Seismic Performance of High Performance Cold Forming Composite Beam

  • Choi, Young Han;Kim, Sung Bae;Hong, Hyung Ju;Kim, Sang Seup
    • 국제강구조저널
    • /
    • 제18권5호
    • /
    • pp.1772-1783
    • /
    • 2018
  • Nowadays, the researches about composite structure system are being implemented in various fields, and many steel structures are designed based on that. In this study, the bending and seismic performance of the newly developed high-performance cold forming composite beam are evaluated by several experiments. As a result of the bending performance test, the bending moment of beam was increased stably depending on the depth and plate thickness of beam, and it is considered that the bending moment can be evaluated by the equation of a composite beam design. As a result of the seismic performance test, it was verified that sufficient seismic performance was obtained despite the increase of a negative moment rebar and depth of beam. In addition, the nominal bending moment has obtained the strength above the plastic bending moment, and also the plastic rotation angle has satisfied the requirement of composite intermediate moment frame.

굽힘하중을 받는 알루미늄 사각관 보의 국부적 좌굴붕괴 거동에 관한 연구 (A Study on the Local Buckling Collapse Behavior of an Aluminum Square Tube Beam under a Bending Load)

  • 이성혁;최낙삼
    • 대한기계학회논문집A
    • /
    • 제27권12호
    • /
    • pp.2011-2018
    • /
    • 2003
  • To analyze the bending collapse behavior of an aluminum square tube beam under a bending load, a finite element simulation for the four-point bending test has been performed. Using an aluminum tube beam specimen partly inserted with two steel bars, the local buckling deformation near the center of the tube beam was induced. The maximum bending load and the bending collapse behavior obtained from the numerical simulation were in good agreement with experimental results. Using a combination of the four-point bending test and its finite element simulation, analysis of the local buckling and the accompanied bending collapse behavior of aluminum tube beam could be quantitative accomplished.

가열 시험을 거친 AU 합성보의 휨 성능에 관한 실험 연구 (Experimental Study on the Flexural Capacity of AU Composite Beam After the Heating Test)

  • 김영호
    • 한국공간구조학회논문집
    • /
    • 제19권3호
    • /
    • pp.77-83
    • /
    • 2019
  • AU(A plus U-shaped) composite beam was developed for reducing the story height in the residential buildings, and saving the cosrtuction cost of floor structures. Structural performance and economic feasibility of the composite beam have been sufficiently approved through the structural experiments and the analytical studies. Fire safety for the practical application of the composite beam has also been verified through the fire resistance tests and the heat transfer analyses. In this study 2-points bending tests were performed on the four specimens already tested for fire resistance to evaluate the residual bending strength of AU composite beam after fire accident. The same bending test was performed on the one fresh specimen having the same section and span of the specimens for practically comparative study.

파임을 가진 국산 침엽수재의 휨성능 및 구조설계기준에 관한 연구 (Bending Properties and Recommened Design Criteria for Domestic Softwood with Notch)

  • 오세창
    • Journal of the Korean Wood Science and Technology
    • /
    • 제26권4호
    • /
    • pp.6-12
    • /
    • 1998
  • Test results of domestic softwood lumber were presented to examine the notch effect of beams and compare to present AIJ(Architecture Institute of Japan) formula in notched wood member especially positioned in bottom side (tension side) of a beam. Notched lumber was tested under following condition : each specimen supported simply, and subjected to third-point loading at points of 1/3 of the span length. Notch was located opposite side to loading direction and notch depth were 1/6, 1/4, 1/3 of beam depth. Deflection and load were measured by digital dial guage each in 25kgf increment. Bending test results were as follows; Mpro/Mmax range (proportional and maxium bending moment ratio in notched beam) was 0.5 - 0.65. It was considered that maxium bending moment was about 1.5 times to proportional bending moment in notched beam and showed same tendency in the test result of ordinary wood specimens. AU standard formula for the tension side notch, Mmat = 0.6 ${\times}$ (Zo $\sigma$), the constant 0.6 was suitble for notch ratio(notch depth to beam depth) 1/6, but this ratio for 1/4, and 1/3 was not. So it is preferable to accept smaller value than 0.6 for notch ratio more than 1/3. These experiment results showed critical effect in tension side notched wood beam especially in greater than notch ratio 1.3 of wood beam. From the above results, it is recommened to revise design formula adoptable to domestic wood constructon member with tension side notched member.

  • PDF

보-슬래브 시스템 구조성능에 관한 실험적 연구 (The Experimental Study on Structural Performance of the Beam-Slab System)

  • 이명재;김철환;이승준;김원기;김희동
    • 한국강구조학회 논문집
    • /
    • 제16권1호통권68호
    • /
    • pp.91-101
    • /
    • 2004
  • 본 연구는 철골조 초고층 아파트에 있어서 주거부분의 충고를 낮추기 위한 새로운 보-슬래브 구조시스템 개발을 위하여 제안되어진 합성보에 대해서 역학적 성능 및 구조적인 검토를 실험적으로 고찰하여 그 타당성을 확인하고 구조설계의 지침을 제시하고자 하는 것이다. 이상과 같은 연구목적을 달성하기 위해서 제안된 아파트의 기준층 구조평면에 근거하여 본 연구의 대상이 되는 9.8m 스팬의 보를 대상으로 구조재료실험, 합성보의 균등 흼실험, 합성보의 중앙집중 재하실험, 휨 전단 가력실험, 그리고 전단 가력실험 등을 진행하였다. 실험결과로부터 상플랜지에 스터드 커넥터를 대한건축학회 강구조계산규준의 합성보 설계 규정에 따라 정상적으로 배치하고 슬래브의 상부 철근을 정상배근하면 충분한 구조적 성능을 발휘할 수 있음을 확인하였다.

GFRP 도어 임팩트 빔과 Steel 브래킷의 기계적 결합에 관한 실험적 연구 (An Experimental Study on the Mechanical Mounting between GFRP Door Impact Beam and Steel Brackets)

  • 하중찬;신영철;백인석;이석순
    • 한국기계가공학회지
    • /
    • 제20권5호
    • /
    • pp.103-110
    • /
    • 2021
  • The mounting performance of the GFRP(Glass fiber Reinforced Plastic) beam and the mechanical mounting of the steel bracket was studied to be mounted as a GFRP impact beam on the side door of the passenger car. Moreover, an open-hole tensile test was performed to evaluate breakage tendency based on GFRP stacking conditions. Furthermore, the tightening strength of rivets and bolts was compared using the single lap-shear tension test for the GFRP stacking pattern. Additionally, the GFRP beam and bracket mounting features were designed; moreover, the prototype and bracket were assembled. Additionally, the bracket mounting bending test and the door assembly static bending test were performed to verify the stability of the bracket mounting. In the bracket fastening bending test, no breakage occurred in the connection part between the GFRP beam and the bracket, and it showed 67% (24.4 kN) improved performance compared to steel. In the static bending test of the door assembly, the initial average reaction force increased by 25% compared to the steel, and the performance of all FMVSS-214 regulations was satisfied. The replacement of GFRP impact beams resulted in a 30% weight reduction

보강 알루미늄 사각관 보의 굽힘 성능평가 (Bending Performance Evaluation of Reinforced Aluminum Square Tube Beams)

  • 이성혁;최낙삼
    • 한국자동차공학회논문집
    • /
    • 제13권5호
    • /
    • pp.171-180
    • /
    • 2005
  • Bending performances of aluminum square tube beams reinforced by aluminum plates under three point bending loads have been evaluated using experimental tests combined with theoretical and finite element analyses. A finite element simulation for the three-point bending test was performed. Basic properties of aluminum materials used for initial input data of the finite element simulation were obtained from the true stress-true strain curves of specimens which had been extracted from the Al tube beams. True stresses were determined from applied loads and cross-sectional area records of a tensile specimen with a rectangular cross-section by real-time photographing, and true strains were obtained from in-situ local elongation measurements of the specimen gage portion by the multi-point scanning laser extensometer. Six kinds of aluminum tube beam specimens adhered by aluminum plates were employed fur the bending test. The bending deformation behaviors up to the maximum load described by the numerical simulation were in good agreement with experimental ones. After passing the maximum load, reinforcing plate was debonded from the aluminum tube beam. An aluminum tube beam strengthened by aluminum plate on the upper web showed an excellent bending capability.

Characteristic responses of critical current in REBCO coated conductor tapes under tensile/compressive bending strains at 77 K

  • Diaz, Mark Angelo;Shin, Hyung Seop;Lee, Jae-Hun
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제20권4호
    • /
    • pp.31-35
    • /
    • 2018
  • When REBCO coated conductors (CCs) are applied to superconducting devices such as coils and magnets, they are subjected to deformation in various modes such as compression/tension bending, uniaxial/transverse tension and torsion. Despite outstanding performances by REBCO CC tapes, their electromechanical properties have been evaluated primarily under uniaxial tension, therefore data about the critical current ($I_c$) response in the compressive strain region are lacking. In this study, the characteristic responses of $I_c$ in REBCO CC tapes under bending strains in the range from tensile to compressive were evaluated. The springboard bending beam was used, wherein the CC tape sample was soldered onto the surface of the springboard. A Goldacker-type bending test rig, which lacks a support holding the sample during testing, was used as a comparator. Degradation in $I_c$ behaviors, including strain sensitivity, in differently processed REBCO CC tapes were examined based on the test rig used.

춤이 작은 신형상 고성능 하이브리드 합성보의 휨성능 평가 (Bending Performance Evaluation of Hybrid Composite Beam with Low Depth and New Shape)

  • 김성배;조성현;오광수;전용한;최영한;김상섭
    • 한국강구조학회 논문집
    • /
    • 제28권3호
    • /
    • pp.151-162
    • /
    • 2016
  • 본 연구는 합성보와 하이브리드보의 장점을 활용한 신형상 하이브리드 합성보의 형상을 개발하였으며, 그 중 춤이 작은 형상의 휨성능을 검증하기 위해 12개의 휨 실험체를 제작하여 단조가력 실험을 진행하였다. 휨성능 실험결과, 공칭하중에 대한 실험체 최대하중의 비는 평균 1.24배로 안정적인 내력을 확보하였으며, 합성보의 내력평가는 기존 합성보 내력평가식(KBC 2009)을 적용 가능한 것으로 판단된다. 또한 하부강판에 고강도강($F_y=650MPa$) 적용 시 소재의 기계적 특성 및 구조성능에 대한 충분한 사전검토가 필요할 것으로 판단된다.

$CO_2$아크 스폿 용접법에 의한 조립보의 굽힘강도에 관한 연구 (A Study on the Bending Strength of a Built-up Beam Fabricated by the $CO_2$ Arc Spot Welding Method)

  • 한명수;한종만;이준열
    • Journal of Welding and Joining
    • /
    • 제15권4호
    • /
    • pp.143-153
    • /
    • 1997
  • In this study, bending test was performed on the real-scale, built-up beam test model fabricated by the $CO_2$ arc spot welding to evaluate the applicability of the welding method to the production of the stiffened plate in car-carrying ship. The built-up beam models which were fixed at both ends in longitudinal direction or simply supported to the rigid foundation, depending on the restraint condition of the corresponding car decks considered, were subjected to simulated design vehicle loads or concentrated point loads. During the test, the central deflection and the longitudinal bending stresses were measured from several points on the longitudinal flange face to predict the section properties of the built-up beams. The longitudinal bending stress on each spot weld were also measured to calculate the average horizontal shear force subjected to spot welds. Test results revealed that the shear strength of spot welds with their current weld nugget size and welding pitch was adequate enough to withstand the horizontal shear forces under the design vehicle loads. Although the built-up beam fabricated by the arc spot welding was a discontinuous beam, its mechanical behavior was well explained by the continuous beam theory using the effective breadth of plate. Based on test results, the criterion for the size of spot weld of which the average shear stress might meet the allowable stress requirement of AWS Code could be established.

  • PDF