• 제목/요약/키워드: behaviour test specimen

검색결과 75건 처리시간 0.026초

Mechanically fastened shear connectors in prefabricated concrete slabs - experimental analysis

  • Gluhovic, Nina;Markovic, Zlatko;Spremic, Milan;Pavlovic, Marko
    • Steel and Composite Structures
    • /
    • 제36권4호
    • /
    • pp.369-381
    • /
    • 2020
  • Nowadays, in prefabricated composite construction, composite action between steel beam and concrete slab is often achieved with positioning of shear connectors in envisaged openings of concrete slabs. Prefabricated concrete slabs are used for composite steel-concrete buildings and bridges, both for the construction of new structures and for renovation of existing ones, significantly reducing construction time. Development of different types of shear connectors represent alternative solution to the traditionally used headed studs, considering their shear resistance, stiffness and ductility. New types of shear connectors tend to reduce the construction time and overall construction cost. Mechanically fastened shear connectors represent a viable alternative to headed studs, considering their fast installation process and shear resistance. X-HVB shear connectors are attached to the steel beam with two cartridge fired pins. The first step towards extensive implementation of X-HVB shear connectors in composite construction is to understand their behaviour through experimental investigation. Results of the push-out tests, in accordance to Eurocode 4, with X-HVB 110 shear connectors positioned in envisaged openings of prefabricated concrete slabs are presented in this paper. The experimental investigation comprised three different specimen's layout. Group arrangement of X-HVB shear connectors in envisaged openings included specimens with minimal recommended distances and specimens with reduced distances between connectors in both directions. Influence of different installation procedures on overall behaviour of the connection is presented, as well as the orientation of shear connectors relative to the shear force direction. Influence of variations is characterized in terms of failure mechanisms, shear resistance and ductility.

점착형 복합 방수시트의 표준(안)제정을 위한 구조물 거동대응성능 시험방법 개선 및 검증 평가 연구 (Verification and Improvement of Structural Behavior Response Performance Evaluation Method for the Standard Establishment of Adhesive Composite Waterproofing Sheets)

  • 김수연;박종선;오상근
    • 한국건축시공학회지
    • /
    • 제21권4호
    • /
    • pp.377-386
    • /
    • 2021
  • 본 연구는 지난 2019년 4월에 대한건축학회 기술표준(AIK-S-001-2019)으로 제정된 복합열화 및 구조체 거동이 동시에 작용하는 환경에서의 방수층 성능 시험방법에 있어 일부 표준 내용 중 현장 시공성 반영 부족 문제와 표준 시공 방법으로서 오류 부분 등이 지적되면서 이를 보완해야 한다는 관련 업계, 시공사, 발주자(건설사) 등에서 의견이 제안되었다. 이에 본 연구를 통하여 시험 항목인 구조물 거동대응성능 시험방법에 있어 현장 시공성, 시험 결과의 정량화, 기타 개선 사항 등을 고찰하였다. 고찰된 내용을 이용하여 표준(안)으로 제정 중인 (가칭)점착형 복합 방수시트에 포함되어 진행하고 있는 구조물거동대응성능 시험방법에 표준 규격으로서 활용 가능성과 현장 시공성 반영 문제 등의 개선 내용을 검토하였다. 또한, 검토된 내용을 반영하여 1차와 2차 성능평가를 실시하여 그 결과를 도출하였다. 이에 본 연구를 통하여 도출된 개선(안) 및 성능평가 결과를 토대로 (가칭) 점착형 복합방수시트 제정(안)의 기초 자료로 활용하고자 한다.

신형 데크플레이트와 철판망을 적용한 합성슬래브의 휨 거동 (Bending Behaviour of Composite Slab Using a New-Shaped Steel Deck Plate and Expanded Metal)

  • 김명모;엄철환
    • 한국강구조학회 논문집
    • /
    • 제15권4호통권65호
    • /
    • pp.403-412
    • /
    • 2003
  • 건축물의 바닥판에 대한 합성슬래브 시스템의 사용이 점차 확대되어 오피스 빌딩을 중심으로 널리 사용되고 있다. 최근에는 주상복합형 및 주거용 건물에 대한 확대 적용을 휘해 하부면이 평탄한 플랫 데크플레이트의 필요성이 대두됨에 따라 플랫 데크플레이트가 개발되고 있다. 또한 합성슬래브시스템의 바닥판 상부에 와이어메쉬 대신 일체형으로 생산되는 익스팬디드 메탈을 적용할 경우, 원가 절감, 공기 단축 효과도 기대할 수 있을 것이다. 본 연구에서는 익스팬디드 메탈을 와이어메쉬의 대체재로 사용하여 이를 하부면이 평탄한 플랫 데크플레이트와 결합시킨 신형식의 합성블래브시스템을 제안하였다. 총 12개의 시험체에 대한 실험을 통해 그 구조성능을 평가하고자 하였다. 실험 결과는 시험체의 최대내력과 파괴거동 등을 중심으로 요약하여 나타냈다.

단일황복면 구성모델을 이용한 정규압밀 점토지반의 비배수 거동해석 (Undrained Behaviour of Normally Consolidated Clay Foundation Using Single-Hardening Constitutive Model)

  • 정진섭;이강일;박병기
    • 대한토목학회논문집
    • /
    • 제14권5호
    • /
    • pp.1229-1241
    • /
    • 1994
  • 본 연구는 탄 소성이론에 기초를 둔 Lade의 단일항복면 구성모델을 이용하여 정규압밀 점토지반의 비배수 거동을 연구한 것이다. 시료는 영산강 하류에서 채취한 무안 점토를 재생성시켜 동방압축팽창시험과 압밀비배수 삼축압축시험을 하여 이 구성모델에 필요한 11개의 토질매개변수를 결정하였다. 또한 비배수거동해석을 위한 유한요소 프로그램을 개발하였으며, 프로그램의 정도를 검증하기 위하여 매개변수결정에 사용된 시험결과를 역해석하였다. 그리고 2차원 모형지반에 재하시험을 실시하고 결과를 유한요소 프로그램으로 수치해석하여 서로 비교 검토하였다.

  • PDF

An experimental study of scale effect on the shear behavior of rock joints

  • Lee Tae-Jin;Lee Sang-Geun;Lee Chung-In;Hwang Dae-Jin
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2003년도 Proceedings of the international symposium on the fusion technology
    • /
    • pp.156-161
    • /
    • 2003
  • Mechanical behavior of rock joints usually can be characterized by small-scale laboratory shear tests due to economical and technical limitations, but their applicability to the behaviour of rock mass has been always questioned by a number of researchers because of scale effect. Though there have been several researches regarding the scale effect, it has been a controversial problem how to apply the result of small-scale laboratory shear test directly to field design from different conclusions among researchers. In order to grasp the trend of scale effect of shear behavior, a series of direct shear tests on replicas of natural rock joint surfaces made of gypsum cement with different size and roughness were conducted and analyzed. Result showed that as the size of the specimen increased, average peak shear displacement increased, but average shear stiffness and average peak dilation angle decreased. As for the dependency of scale on shear strength, the degree of scale effect was dependent on normal stress and roughness of rock joint. For the condition of low normal stress and high roughness, decrease of average peak shear strength with increasing size of joint was evident.

  • PDF

Seismic analysis of a masonry cross vault through shaking table tests: the case study of the Dey Mosque in Algiers

  • Rossi, Michela;Calderini, Chiara;Roselli, Ivan;Mongelli, Marialuisa;De Canio, Gerardo;Lagomarsino, Sergio
    • Earthquakes and Structures
    • /
    • 제18권1호
    • /
    • pp.57-72
    • /
    • 2020
  • This paper presents the results of a monodirectional shaking table test on a full-scale unreinforced masonry cross vault characterized by asymmetric boundary conditions. The specimen represents a vault of the mosque of Dey in Algiers (Algeria), reproducing in detail the mechanical characteristics of masonry, and the constructive details including the presence of some peculiar wooden logs placed within the vault's abutments. The vault was tested with and without the presence of two steel bars which connect two opposite sides of the vault. The dynamic behaviour of both the vault's configurations were studied by using an incremental dynamic analysis up to the collapse of the vault without the steel bars. The use of an innovative high-resolution 3D optical system allowed measure displacement data of the cross vault during the shake table tests. The experimental results were analysed in terms of evolution of damage mechanisms, and in-plane and out-of-plane deformations. Moreover, the dynamic properties of the structure were investigated by means of an experimental modal analysis.

9% Ni강의 피로균열진전거동에 관한 연구 (A Study on the Fatigue Crack Growth Behavior of 9% Ni Steels)

  • 심규택;김재훈;이관희;안병욱;김영균
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.167-172
    • /
    • 2008
  • This study is to evaluate the fatigue crack growth characteristics for base metals and welded metal of 9% Ni steels. Since this material has very excellent fracture toughness at low temperature, it has been widely used for inner walls of LNG storage tank. These materials to compare fatigue crack growth (FCG) behaviour are treated with heat by the method of quenching and tempering (QT), and quenching, lamellarizing and tempering (QLT). FCG tests using compact temsion (CT) specimen under stress ratio R=0.1, 0.5, and constant load are carried out. K-increasing tests are conducted by the standard test method described in ASTM E 647. To investigate the effect of welded metal on the crack growth rate, the locations of notch tip were chosen at the center of welded metal and heat affected zone (HAZ). Form the results, FCG rate has almost same tendency according to stress ratio, base and welded metal, the locations of welded metal. FCG rate of welded metal is somewhat faster than base metal. Also scanning electron microscope (SEM) is used to observe the striation of the fractured surface after fatigue crack tests.

  • PDF

인장부재(引張部材)에 뚫은 Stop-hole 이 피로균열성장율(疲勞龜裂成長率)에 미치는 영향(影響)에 관한 연구(研究) (A Study on the Effect of the Stop-hole on the Fatigue Crack Growth Rates in Tensile Members)

  • 장동일;정경섭
    • 대한토목학회논문집
    • /
    • 제7권4호
    • /
    • pp.115-124
    • /
    • 1987
  • 본 연구는 피로균열이 발생한 부재의 응급적인 보수, 보강방법으로 예로부터 실제로 이용되어 온 stop-hole에 대하여 그 보수, 보강효과를 잔존수명의 관점에서 정량적인 평가를 시도한 것이다. 이를 위하여 대상 시험편에 대한 피로시험을 실시하여 그 피로거동을 검토한 결과, 피로균열에 대한 응급조치로서 stop-hole을 이용할 경우, 균열이 탄소성 거동을 하는 영역에 이르기 전에 처리하는 것이 바람직함을 알 수 있었다.

  • PDF

Characterisation of Tensile Deformation through Infrared Imaging Technique

  • B. Venkataraman, Baldev Raj;Mukhophadyay, C.K.
    • 비파괴검사학회지
    • /
    • 제22권6호
    • /
    • pp.609-620
    • /
    • 2002
  • It is well known that during tensile testing, a part of the mechanical work done on the specimen is transformed into heat energy. However, the ultimate temperature rise and the rate of temperature rise is related to the nature of the material, conditions of the test and also to the deformation behaviour of the material during loading. The recent advances in infrared sensors and image/data processing techniques enable observation and quantitative analysis of the heat energy dissipated during such tensile tests. In this study, infrared imaging technique has been used to characterise the tensile deformation in AISI type 316 nuclear grade stainless steel. Apart from identifying the different stages during tensile deformation, the technique provided an accurate full-field temperature image by which the point and time of strain localization could be identified. The technique makes it possible to visualise the region of deformation and failure and also predict the exact region of fracture in advance. The effect of thermal gradients on plastic flow in the case of interrupted straining revealed that the interruption of strain and restraining at a lower strain rate not only delays the growth of the temperature gradient, but the temperature rise per unit strain decreases. The technique is a potential NDE tool that can be used for on-line detection of thermal gradients developed during extrusion and metal forming process which can be used for ensuring uniform distribution of plastic strain.

DEM analysis of the anisotropy effects on the failure mechanism of the layered concretes' specimens with internal notches

  • Jinwei Fu;Vahab Sarfarazi;Hadi Haeri;Mohammad Fatehi Marji
    • Computers and Concrete
    • /
    • 제33권6호
    • /
    • pp.659-670
    • /
    • 2024
  • The mechanical behaviour of layered concrete samples containing an internal crack was numerically studied by modelling the geo-mechanical specimens in the particle flow code in two dimensions (PFC2D). The numerical modelling software was calibrated with the experimental results of the Brazilian tensile strengths gained from the laboratory disc-type specimens. Then, the samples with the bedding layers and internal notch were numerically simulated with PFC2D under uniaxial compressive loading. In each specimen, the layers' thickness was 10 mm but the layer's inclination angle was changed to 0°, 30°, 60°, 90°, 120° and 150°. Of course, the layers'interfaces are considered to have very low strengths. The internal notch was kept at 3 cm in length however, its inclination angle was changed to 0°, 40°, 60° and 90°. Therefore, a total, of 24 numerical models were made to study the failure mechanism of the layered concrete samples. Considering these results, it has been concluded that the inclination angles of both internal crack and bedding layers affect the failure mechanism and uniaxial compressive strength of the concrete.