• Title/Summary/Keyword: base cavity

Search Result 152, Processing Time 0.035 seconds

A Study on the Relationship of Sociological Characteristics to Oral Health Status in Population International Marriage Migrant Women (국제결혼 이주여성의 인구사회학적 특성과 구강건강상태와의 관계 연구)

  • Yun, Hyun-Kyung;Lee, Seung-Hee;Choi, Gyu-Yil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.2
    • /
    • pp.678-684
    • /
    • 2012
  • The purpose of this study is to figure out and establish the basic data that can help improve management of oral healthcare for the international marriage migrantwomen. In this sense, we surveyed questions on 237 women out of 1,300 immigrant women, who have participated the program in operation by multi-cultural household supporting center, in a fashion of face-to-face investigation and on-the-spot direct cavity inspection simultaneously from May 1th to October 31th, 2010. Collected data were electro-statistically computerized under SPSS 17.0 program and analyzed with frequency analysis, recurrence analysis and logistic regression analysis respectively. Foundings were revealed as follows; On the nationality base, show the data in the ratio of 38.8% for Vietnamese, 29.1% for Philippine, 12.2% for Chinese and 6.8% for Japanese respectively. Current oral cavity status shows in the ratio of 60% with carious tooth symptoms, 40% without carious tooth symptom. Philippine women have irregular sets of tooth in many a case. (i.e., in short of numbers of teeth, due to removing individual tooth.) Japanese ladies are indicated to have less irregular sets of tooth, in comparison with that of the other immigrants from overseas. And lastly, high-income immigrant women in general were found having less numbers of unhealthy sets of tooth. Getting older, it appears that decayed tooth symptom is on the tendency of getting less in the field of dentistry circles. Immigrant ladies living with husbands under higher education background usually are found living a life in the less ratio of having toothache. A full-time immigrant housewives, however, are living everyday life in more times of suffering with tooth disease.

A CHANGE OF THE SALIVARY FLUORIDE CONCENTRATION AFTER FLUORIDE-CONTAINING TAPE APPLICATION (불소 테잎 적용 후 시간변화에 따른 타액 내 불소농도)

  • Park, Seung-Hyo;Lee, Sang-Ho;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.3
    • /
    • pp.377-384
    • /
    • 2009
  • The purpose of this study is to investigate the residual fluoride concentration of fluoride tape in oral cavity which made by spraying NaF on carboxymethylcellulose base. After 1, 3, 5, 7 hours and 1, 2, 3 days of applicating APF gel(60seconds $taste^{(R)}$, 1.23% APF gel, Group I), Fluoride varnish($CavityShield^{TM}$, 5% NaF, Group II) and Fluoride tape(SCMC-T-5, 5% NaF, Trial product, Group III) in oral cavity of 27 healthy adults in their twenties, the result of fluoride concentration in unstimulated whole saliva which measured by using fluoride sensitive electrode made up to following conclusion. 1. Until 7 hours after application in every group, it showed significantly higher fluoride concentration in saliva than baseline value but at 1, 2, 3 days after application, there were no significant differences between measurements and baseline value(p>0.05). 2. Until 7 hours after application at every time, mean fluoride concentration in saliva was higher in the order of Group II, I and III. 3. 1 hour and 3 hours after application, Group II revealed significantly higher fluoride concentration than Group III(p<0.05), but there were no significant differences between Group Ⅰ and Group III in every time.

  • PDF

Numerical Simulation of Ocean - Ice Shelf Interaction: Water Mass Circulation in the Terra Nova Bay, Antarctica (해양-빙붕 상호작용을 고려한 남극 테라노바 만에서 수괴 형성과 순환의 수치 시뮬레이션)

  • Taekyun, Kim;Emilia Kyung, Jin;Ji Sung, Na;Choon Ki, Lee;Won Sang, Lee;Jae-Hong, Moon
    • Ocean and Polar Research
    • /
    • v.44 no.4
    • /
    • pp.269-285
    • /
    • 2022
  • The interaction between ocean and ice shelf is a critical physical process in relation to water mass transformations and ice shelf melting/freezing at the ocean-ice interface. However, it remains challenging to thoroughly understand the process due to a lack of observational data with respect to ice shelf cavities. This is the first study to simulate the variability and circulation of water mass both overlying the continental shelf and underneath an ice shelf and an ice tongue in the Terra Nova Bay (TNB), East Antarctica. To explore the properties of water mass and circulation patterns in the TNB and the corresponding effects on sub ice shelf basal melting, we explicitly incorporate the dynamic-thermodynamic processes acting on the ice shelf in the Regional Ocean Modeling System. The simulated water mass formation and circulation in the TNB region agree well with previous studies. The model results show that the TNB circulation is dominated by the geostrophic currents driven by lateral density gradients induced by the releasing of brine or freshwater at the polynya of the TNB. Meanwhile, the circulation dynamics in the cavity under the Nansen Ice shelf (NIS) are different from those in the TNB. The gravity-driven bottom current induced by High Salinity Shelf Water (HSSW) formed at the TNB polynya flows towards the grounding line, and the buoyance-driven flow associated with glacial meltwater generated by the HSSW emerges from the cavity along the ice base. Both current systems compose the thermohaline overturning circulation in the NIS cavity. This study estimates the NIS basal melting rate to be 0.98 m/a, which is comparable to the previously observed melt rate. However, the melting rate shows a significant variation in space and time.

Clinical Assessment of Intracranial Mesenchymal Tumors with Relevant to Non-meningothelial Tumors (두개강내 원발성 간엽성 종양에 대한 임상 고찰)

  • Yi, Hyeong Joong;Kim, Choong Hyun;Bak, Koang Hum;Kim, Young Soo;Kim, Jae Min;Ko, Yong;Oh, Suck Jun;Kim, Kwang Myung
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.1
    • /
    • pp.44-50
    • /
    • 2000
  • Objective : A few anecdotal cases of mesenchyme-derived tumors which grow into a cranial cavity have been reported that disclosed a dismal prognosis, due to their critical location, aggressive biological behavior, and high rate of surgical morbidity. The aim of this study is to search clinical factors related to these tumors. Methods : Eight patients who underwent surgical removal of intracranial mesenchymal tumors between January 1993 and December 1997 were studied retrospectively. The tumors included are three chordomas, two chondrosarcomas, two rhabdomyosarcomas, and one hemangiopericytoma. Authors compared clinical features, treatment, and results of our cases with reported cases. The mean follow-up period was 20.5 months. Results : All cases showed nonspecific, location-related clinical findings and arose from sphenopetroclival region. Single stage operation was performed in 4 cases, and skull base approaches in 3 cases. Adjuvant therapies were done in 2 cases. Recurrence was seen in 3 cases(37.5%), and 3 patients died. Interdisciplinary approach with otologic surgeon was done in 2 cases. Conclusion : Recent advancement of refined tactics has made these tumors amenable and provides prolongation of progression-free survival. These are modified skull base approaches, multi-modality treatment options, and inter-disciplinary team approaches. Good results may be expected for these mesenchymal tumors by aggressive resection and adjuvant therapies according to their biological nature.

  • PDF

Evaluation of internal adaptation of dental adhesive restorations using micro-CT

  • Kwon, Oh-Hyun;Park, Sung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.1
    • /
    • pp.41-49
    • /
    • 2012
  • Objectives: The internal adaptation of composite restorations with or without resin modified glass ionomer cement (RMGIC) was analyzed non-destructively using Microcomputed tomography (micro-CT). Materials and Methods: Thirty intact human teeth were used. The specimens were divided into 3 groups. In the control group, the cavities were etched with 10% phosphoric acid for 15 sec. Composite resin was filled into the cavity without adhesive. In group 1, light cured glass ionomer cement (GIC, Fuji II LC, GC) was applied as a base. The cavities were then etched, bonded, light cured and filled with composites. In group 2, the cavities were then etched, bonded, light cured and filled with composites without base application. They were immersed in a 25% silver nitrate solution. Micro-CT was performed before and after mechanical loading. One-way ANOVA with Duncan analysis was used to compare the internal adaptation between the groups before or after loading. A paired t-test was used to compare internal adaptation before and after mechanical loading. All statistical inferences were made within the 95% confidence interval. Results: The silver nitrate solution successfully penetrated into the dentinal tubules from the pulp spaces, and infiltrated into the gap between restoration and pulpal floor. Group 2 showed a lower adaptation than the control group and group 1 (p < 0.05). There was no significant difference between the control group and group 1. For all groups, there was a significant difference between before and after mechanical loading (p < 0.05). Conclusions: The internal adaptation before and after loading was better when composites were bonded to tooth using adhesive than composites based with RMGIC.

TREATMENT OF DENTIGEROUS CYST: REPORT OF A CASE (함치성양종의 치험예)

  • Kim, Kwang-Hyun;Lee, Bong-Won
    • The Journal of the Korean dental association
    • /
    • v.15 no.1
    • /
    • pp.27-31
    • /
    • 1977
  • Dentigerous cysts are closed epithelium-lined sacs formed about the crowns of unerupted teeth. Most of them probably are the result of degenerative changes in the reduced enamel epithelium. The authors observed 1 3 year old girl with a swelling and buccal bony expansion of the left mandible. Roentgen examination showed a cystic area in the left side of mandible. Under general anesthesia by means of nasotracheal intubation, intraorally, the operation by enucleation consisted in surgical removal of dentigerous cyst and the left unerupted Ist molar of mandible. The cavity was partially sutured and packed with iodoform gauze. Healing was uneventful.

  • PDF

Development of Stabilizing Agent for Double Base Propellant Rocket Motor (복기 추진제 로켓 모타 연소 안정제 개발)

  • 손원경;최성한;이원복
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1994.04a
    • /
    • pp.23-26
    • /
    • 1994
  • 130mm D.B. 추진기관의 고온 시험에서 나타난 극심한 이상 연소 현상을 해결하기 위해 미세한 고체 입자들을 연소 가스에 분산시켜 불안정 연소를 억제하는 particulate damping 효과를 연구하였다. 고체 입자로서 효과적인 것으로 알려진 $K_2$$SO_4$. ZrC, Graphite를 CTPB, HTPB 고분자 물질에 충진시켜 epoxide, isocyanate 반응기와 가교 반응을 일으킴으로써 고무상의 탄성체 성질을 갖게 하는 $K_2$$SO_4$/CTPB, ZrC/Graphite/HTPB, ZrC/Graphite/AP/HTPB, ZrC/AP/HTPB 조성의 연소 안정제를 개발하였다. 이 연소 안정제는 외경 17mm, 길이 1000mm의 안정봉 형태로 제작하여 모타의 중심 cavity에 조립한 후 지상 연소 시험을 통하여 성능을 확인하였다. 시험 결과, 조성에 AP를 포함시켜 연소 안정제에 일정한 연소 속도를 부여하여 추진제 grain 연소 동안 고체 입자를 연소 가스에 분산되게 설계한 ZrC/Graphite/AP/HTPB, ZrC/AP/HTPB 조성의 연소 안정제가 불안정 연소 억제에 효과적인 것으로 나타났다.

  • PDF

The Electric Control Method on the Packaging Technology for Non-Conductive Materials Using the Surface Processing Cavity Pressure Sensor (표면 가공형 캐비티 압력센서를 이용하여 비전도성 물질용 패키지 기술에 전기적 제어방식 연구)

  • Lee, Sun-Jong;Woo, Jong-Chang
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.5
    • /
    • pp.350-354
    • /
    • 2020
  • In this study, a pressure sensor for each displacement was fabricated based on the silicon-based pressure sensor obtained through simulation results. Wires were bonded to the pressure sensor, and a piezoresistive pressure sensor was inserted into the printed circuit board (PCB) base by directly connecting a micro-electro-mechanical system (MEMS) sensor and a readout integrated circuit (ROIC) for signal processing. In addition, to prevent exposure, a non-conductive liquid silicone was injected into the sensor and the entire ROIC using a pipette. The packaging proceeded to block from the outside. Performing such packaging, comparing simple contact with strong contact, and confirming that the measured pulse wavelength appears accurately.

Cycle Time Reduction with Automated Gate Cutting Mechanism and Injection/Compression Molding for Producing Mobile LGP (모바일용 도광판의 게이트 자동절삭 및 사출/압축 성형법을 적용한 사이클 타임 저감에 관한 연구)

  • Min, I.K.;Kim, J.S.;Yoon, K.H.
    • Transactions of Materials Processing
    • /
    • v.21 no.2
    • /
    • pp.96-100
    • /
    • 2012
  • Conventional injection molding system for producing extremely thin-wall parts such as Light Guide Plates(LGP's) for mobile displays is at the limit of its capability due to its tendency to develop frozen layers and the critical speed of injection. The molten polymer in the cavity freezes quickly as its heat is rapidly transferred to the mold base. Many attempts have been tried in the past to overcome this problem. The present study used the injection/compression molding technology to produce a thin-wall part, with enhanced features such as an automated mechanism for cutting gates. As a result, the total cycle time was reduced by almost 35 seconds, resulting in a productivity increase by 30%.

A Study on the Avoidance of Tool Interference in Analytic Compound Surface Machining (해석적 복합 곡면 가공에 있어서의 공구 간섭 방지에 관한 연구)

  • Kang, S.G.;Cho, S.W.;Ko, S.L.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.9
    • /
    • pp.156-164
    • /
    • 1996
  • Tool interference is one of the most critical problems in machining die cavities and punches. When machining concave or convex regions of cavities with large radius tool in rough cutting, the tool easily overcuts or undercuts the portions of the surface, which result in machining inaccuracy. So the generation of interference-free tool path must be required for more efficient rough cutting. In this paper, we present a method for modeling die cavities which consist of simple surface or analytic compoyund surfaces and present an algorithm for checking and removing the tool interference occurred in machining the die cavities. Using these algorithms, we can represent a die cavity, and check the interfer- ence regions, and then remove these interferences. Especially we focus on the side interference in the sides of analytic elements and base surface boundary.

  • PDF