• 제목/요약/키워드: bar structure

검색결과 779건 처리시간 0.033초

전식녹을 제거한 철근과 콘크리트의 부착응력에 관한 실험적 연구 (Bond Stress of the Bar Removed Rust with Concrete)

  • 최효석;이주일;류수현;유호현;김진무
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제5권1호
    • /
    • pp.188-194
    • /
    • 2001
  • A reinforced concrete structure is complex structure that works as one body with bonding role of steel bar and concrete. The bonding action between steel bar and concrete makes possible the compound structure. The transmission of mutual strength of the steel bar with concrete in structure is determined by the bonding characteristic of steel bar and concrete surface. But the efficiency of bonding characteristic of steel bar is Questionable by the corrosion cause by the delay construction term, the wrong management, etc. So this study investigate bonding characteristic of reinforced concrete using pull-out test method which steel bar removed rust and the principal variables of this study are concrete compression strength and the degree of corrosion. The result showed that bonding strength tend to increase when removed rust of steel bar whereas it tend to decrease when not removed rust.

  • PDF

앤티롤바의 취부위치에 따른 철도차량의 실내소음에 대한 연구 (The study of the effects to the structure borne noise in terms of the Anti-Roll Bar's mounting position)

  • 박희준;우관제
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.1794-1798
    • /
    • 2008
  • Inside noise level of a running train in open field is the summation of air borne noise and structure-borne noise. Anti-roll bar is the major transmission path of vibration from bogie. And this vibration gives an effect to the structure borne noise. In this paper, the effect of anti-roll bar is investigated. Structure borne noise is analyzed in terms of changing the mounting position of anti-roll bar to reduce inside noise levels.

  • PDF

임플란트의 수와 어태치먼트의 종류에 따른 하악 임플란트 지지 오버덴춰의 삼차원 광탄성 응력분석 (A THREE DIMENSIONAL PHOTOELASTIC STRESS ANALYSIS OF IMPLANT-SUPPORTED MANDIBULAR OVERDENTURE ACCORDING TO IMPLANT NUMBER AND ATTACHMENT TYPE)

  • 한상훈;태윤섭;진태호;조혜원
    • 대한치과보철학회지
    • /
    • 제35권3호
    • /
    • pp.577-608
    • /
    • 1997
  • The purpose of this study is to evaluate the stress distribution in the bone around dental implants supporting mandibular overdenture according to the number of implant and the type of attachment. Two or four implants were placed in an edentulous mandibular model and three dimensional photoelastic stress analysis was carried out to measure the fringe order around the implant supporting structure and also to calculate principal stress components at cervical area of each implant. The attachments tested were rigid and resilient type of Dolder bar, Round bar, Hader bar and Dal-Ro attchment. The results were as follows ; 1. In 2-implant supported overdenture using Round bar, Hader bar, and Dal-Ro attachment, compressive stress pattern was observed on the supporting structure of implant on loaded side, while tensile stress pattern in unloaded side. 2. In 2-implant supported overdenture using Dolder bar, the rigid Dolder bar shared the occlusal loads between 2 implants in a more favorable manner than was exhibited by the resilient type, while the resilient type placed a more stress on the distocervical area of the implant on the loaded side. But compressive stress pattern was observed in both the loaded and unloaded sides in either case. 3. In 2-implant supported overdenture, rigid and resilient type of Dolder bar exhibited more cross arch involvement than the Round bar, Hader bar, or Dal-Ro attachment. 4. In 4-implant supported overdenture using resilient Dolder bar and Hader bar, stress turned out to be distributed evenly among the implants between loaded and unloaded side, but thor was no reduction in the magnitude of the stress in the surrounding structure of implant contratry to 2-implant supported overdenture. 5. The stress pattern at cervical area of implant was different with the number of implant or the type of attachment but the overload, harmful to surrounding structure of implant, was not observed.

  • PDF

'3전법륜설'의 해석학적 지평으로 본 삼성설의 구조 (The Structure of the Theory of Three Natures from the Hermeneutic Perspective of "the Three Turns of the Dharma Cakra")

  • 김재권
    • 철학연구
    • /
    • 제117권
    • /
    • pp.35-55
    • /
    • 2011
  • 이 논문은 "유가론석"이나 "석궤론" 등 인도의 초기 유식논서에 보이는 "해심밀경"의 '3전법륜설'에 대한 유가행파의 해석학적 입장이나 그 사상적 특징을 해명한 후, 이러한 해석학적 입장이 유식학파의 주요교설 가운데 이제설이나 삼성설 등에 어떻게 적용되고 있는가를 살펴본 것이다. 우선 '3전법륜설'은 "반야경" 계통의 공사상을 미료의로 설정하고, 용수를 대표로 하는 초기중관파를 제2시로 설정하고 있는 점을 그 특징으로 볼 수 있다. 이러한 '3전법륜설'의 구체적인 내용은 유가행파가 용수의 이제설 가운데 세속제의 영역을 좀 더 세분화하고, 즉 세속을 언어적인 표현으로만 존재하는 것과 실재로서 존재하는 세속으로 구분하여 의타기성을 기반으로 한 삼성설의 구조를 통해 '허무론이나 악취공'에 떨어지지 않는 공사상의 교설 체계를 새롭게 확립시키고 있는 점에서 확인된다. 한편 '3전법륜설'의 해석학적 입장은 "중변론"의 허망분별의 구조 속에 그대로 계승되어, 안혜의 주석에서 보이듯이 교리적으로 확립되어 적용되고 있음을 확인할 수 있었다. 그 특징을 간략하게 정리하면, 우선 세속적 실재로서 새롭게 확립된 '허망분별'은 의타기성으로 설정되고, 특히 의타기성인 허망분별은 유부의 실체론적인 <유견(有見)>과 세속적 실재인 의타기성을 손감하는 중관파의 <공견(空見)>을 비판적으로 지양하는 입장에서 설정된 것임을 알 수 있다. 또한 안혜의 주석에 제시된 5종의 견해를 보면, 삼성이 초기불교 이래의 모든 교설체계를 통합하려는 의도에서 근본 진실로 다시 설정되고 있음을 알 수 있다. 이 때 삼성설은 기본적으로 허망분별을 기반으로 확립되었고, 그 허망분별의 구조 속에 유식적인 이제가 도사리고 있음을 명확히 확인할 수 있다. 사실 그것에는 유가행파의 독특한 실재관이나 진리관이 반영된 것으로 이해된다.

이질구조부 보주근 정착방법에 따른 혼합구조보의 구조적 특성에 관한 연구 (A Study on the Structural Properties of Composite Beam with Attaching Method of Main Bar of Different Types of Structure.)

  • 김상헌;임병호;이승조;박정민;김화중
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.121-126
    • /
    • 2000
  • The attaching method of different types of structure and explanation of stress transfer mechanism are at important issue as beam having definitive factor such as the anchorage of RC main bar, the stress transfer of anchorage-end S member, RC member-anchorage, anchorage-end S member in the composite beam of S and RC member. In this study, the structural properties of composite beam according to attaching method of main bar about end RC-middle S beam were investigated in order to use them as fundamental data for the development of composite structure member. Throughout a series of study, it was shown that the proof stress of main bar - flange welding specimen is the highest and there is no difference between the deformation-properties according to attaching method of main bar.

  • PDF

선조립공법을 활용한 원전구조물 철근모듈화 Mock-up 실험연구 (Mock-up Test for Nuclear Power Plant Rebar Modulation Applying Febrication)

  • 임상준;이병수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.13-14
    • /
    • 2015
  • To minimize construction of nuclear facility, it is required to reduce reinforcing bar amount and solve reinforcing bar concentration and for this, it is necessary to develop appication design technology and modular of high strength reinforcing bar. Hence, KHNP reduces excessive reinforcing bar amount which can cause possibility of poor construction of concrete through design standard development and modular of nuclear facility structure using high strength reinforcing bar to raise economics and has its purpose to maintain high-level safety and durability as they are. After reviewing the rebar drawing of the NPP structures and performing the mock-up test, the rebar modulation method in the various area of the NPP Structure has been established.

  • PDF

고등학교 공통 과학 강의에서 교사에 따른 역동적 구조의 정량적 비교 분석 (A Comparative Analysis of the Kinetic Structure in Lectures on a High School Science)

  • 유승근;이준상
    • 한국과학교육학회지
    • /
    • 제20권4호
    • /
    • pp.505-509
    • /
    • 2000
  • 담화단위의 연관도를 측정하는 평균기본계수 $(\bar{B}_1)$, 평균가중계수 $(\bar{B}_2)$ 그리고 진행도 (P)는 다음과 같다. T1($\bar{B}_1$, 0.21: $\bar{B}_2$, 0.86: P. 0.79), T2($\bar{B}_1$, 0.02:$\bar{B}_2$, 0.85: P. 0.80), T3($\bar{B}_1$, 0.22: $\bar{B}_2$, 0.83: P.0.78) and T4($\bar{B}_1$, 0.14: $\bar{B}_2$, 0.82: P. 0.86), T4 교사는 다른 교사들에 비해 낮은 역동적 구조를 나타냈으나 수업은 빠른 진행도를 보였다. 총 담화단위 수, 어소의 총 빈도 수, 어소의 종류 수는 T1, T2, T3,T4 교사의 순으로 나타났다. 결과적으로 T4 교사는 다른 교사에 비해 수업 내용의 역동적 구조가 전체적으로 볼 때 낮은 수준을 보였는데, 그 주된 이유는 T4 교사는 수업 준비를 체계적으로 하지 않아, 수업내용이 상대적으로 적었기 때문으로 추측된다. 게다가 T4 교사가 담당하고 있는 학급이 1개 학급이기에 반복적인 수업이 이루어지지 않아 자기 분석의 기회가 없었고, 수업의 내용이 전공 영역과의 관련성이 적었으며 교직 경력 또한 다른 교사보다 낮았기 때문으로 사료된다.

  • PDF

축소모형실험을 통한 터널 내 급속침수 차폐자동화 시스템 작동형태에 대한 연구 (An experimental study on the operation mode of rapid flooding protection system in tunnel)

  • 김연덕;공민택;황병현;김상환
    • 한국터널지하공간학회 논문집
    • /
    • 제20권6호
    • /
    • pp.1147-1159
    • /
    • 2018
  • 본 연구는 팽창구조체를 이용한 급속차폐 자동화 시스템 검증에 중점을 두었다. 팽창구조체는 해저터널의 침수사고 발생시 막대한 인적 및 물적 피해가 발생하는데 이를 대비한 자동 급속차폐시스템이다. 특히 해저터널의 시공 및 운영에 있어 필수적이라고 할 수 있다. 본 연구는 이러한 문제에 대하여 고안된 팽창구조체를 이용한 급속차폐 자동화 시스템을 실험적으로 검증하였다. 이러한 검증을 하기 위해 모형터널을 40:1 축소율을 적용한 실내모형을 제작하여 0.1 bar, 0.15 bar의 공기압을 주입하여 10 sec, 20 sec로 팽창속도에 따라 나누어 4 case로 실험을 진행하여 누수량, 수압 등을 분석하였다. 연구 결과에 의하면 팽창구조체의 팽창 시 0.1 bar 보다 0.15 bar일 때 차폐효율이 좋았으며 팽창구조체의 공기압 주입 시간에 따른 차폐효율 및 유입수 제어효율의 차이도 나타났다. 본 연구 진행 결과 팽창구조체가 완벽하게 팽창한다는 가정조건에서는 팽창구조체의 내부공기압이 높고 팽창속도가 빠를수록 더욱 효과적으로 나타났다. 본 연구 결과로 향후 추가적인 팽창구조체의 보관방법, 형상과 팽창유도체 및 차폐시 팽창구조체의 이동억제와 유입수 제어에 도움이 되는 쐐기형 구조물에 대한 추가적인 연구가 필요하다.

최적배근그룹 선정방법을 적용한 전단벽체의 자동배근 시스템 개발에 관한 연구 (The Study on the Development of Automatic Rebar Placement System Applying Selection Method of Optimum Reinforcing Bar Group on Shear Wall)

  • 조영상;김동은;진현아;장현석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권1호
    • /
    • pp.81-89
    • /
    • 2015
  • 본 연구에서는 철근콘크리트구조에서 전단벽체를 대상으로 설계단계에서부터 Set-Based Design과 계층화분석기법을 통하여 선정된 최적배근그룹을 적용한 S-BIM기반 자동철근배근시스템 제안을 목적으로 한다. 복합적인 기준에 대한 쌍대비교 분석을 통해 최적 철근배근그룹을 선정하고 BIM 소프트웨어 벤더 (Vendor)에서 제공하는 Open API를 이용하여 구조설계 알고리즘을 통한 부재의 생성 및 철근배근이 자동으로 수행될 수 있도록 하였다. 결과적으로 가중치가 가장 높은 ALT1 (0.142)의 최적철근배근그룹이 선정되었고, 이를 TS상에 생성하였다.

높은 광출력을 갖는 Laser Diode Bar의 열응력 개선: 마이크로-홈 도입을 통한 응력 분포 변화 분석 (Thermal Stress Relief through Introduction of a Microtrench Structure for a High-power-laser-diode Bar)

  • 정지훈;이동진;오범환
    • 한국광학회지
    • /
    • 제32권5호
    • /
    • pp.230-234
    • /
    • 2021
  • 열응력 완화 기술은 고출력 레이저 다이오드의 빔의 품질과 안정성을 향상시키기 위한 주요 요소기술로 큰 주목을 받고 있다. 본 연구에서는 레이저 다이오드 바(LD-bar) chip-on-submount (CoS)에 발생하는 열응력 분포 양상을 SolidWorks 소프트웨어를 사용하여 해석하고, 마이크로-홈 구조 도입에 따라 열응력 완화에 미치는 영향을 체계적으로 분석한다. 마이크로-홈 구조는 누적응력을 차단하는 효과가 있는 반면, 열흐름을 방해하는 역기능도 있으므로, 시스템 구조와 방열금속판 두께에 따라 홈 깊이를 최적화할 필요가 있다. 간단히 도입된 예시구조에 대하여, LD-bar CoS의 칩 홀더 금속판에 도입하는 마이크로-홈 구조 최적화를 통해 칩 전면부 표면 응력을 마이크로-홈 구조가 없는 경우의 약 1/5 정도로 낮추었다. 향후 초고출력 시스템에서 방열을 위한 열저항과 광출력 빔크기를 최소한으로 유지하면서, 열응력을 효과적으로 완화시키는 구조로 활용이 기대된다.