• Title/Summary/Keyword: ballast water

Search Result 220, Processing Time 0.027 seconds

Development of sampling device for monitoring micro-organisms in treated ballast water (밸러스트 처리수 미생물 모니터링을 위한 Sampling Device 개발)

  • Park, Sung-Jin;Kim, Ki-Wook;Yoon, Seung-Je;Cho, Dong-Yeon;Kim, Sang-Yong
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.06a
    • /
    • pp.312-312
    • /
    • 2011
  • All ship's ballast water should be inspected by administration after enter into force IMO BWM Convention. The purpose of the sampling device is to concentrate large amount of samples and to improve return rate of samples. It is composed of Concentration and Rinsing Part and optimized by the variety of tests. it is fully automated and therefore efficiently operated in ships.

  • PDF

Design and Fabrication of Ballast Water Treatment System using Fuzzy PID Controller (퍼지 PID 제어 기법을 이용한 선박평형수 처리 시스템 설계 및 제작)

  • Lee, Young-Dong;Ahn, Byeong-Gu;Noh, Yun-Hong;Jeong, Do-Un
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.16 no.3
    • /
    • pp.108-114
    • /
    • 2015
  • Ballast water is carried by ships to ensure stability, trim and structural integrity. When a ship loads cargo, the ballast water is discharged. When foreign marine microorganisms are introduced into new marine environments, they pose a threat to the local marine ecological system. UV system is commonly used for the disinfection of waste and surface water. This method would not be as efficient because some species do survive to form viable populations, much of the sediment and organisms at the bottom of tanks, and may become serious pests. In this paper, we designed and implemented ballast water treatment system using fuzzy PID controller to prevent lamp damage, and to reduce the formation of the viable populations. The experiments were conducted with ballast water treatment system using fuzzy PID controller with short time exposure to the temperature above $40^{\circ}C$. This system was shown to be effective by significantly reducing bacterial population and lamp life extension through appropriate temperature of ballast water.

Risk Assessment for Retrofitting an Electrolysis Type Ballast Water Treatment System on an Exiting Vessel (현존선에 전기분해방식 선박평형수 처리장치 설치를 위한 위험도 평가 분석)

  • JEE, Jae-Hoon
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.29 no.3
    • /
    • pp.665-676
    • /
    • 2017
  • Over the past several years, sea trade have increased traffic by ships which highlighted a problem of unwanted species invading the surrounding seas through ship's ballast water discharge. Maritime trade volume has continuously increased worldwide and the problem still exists. The respective countries are spending billions of dollars in an effort to clean up the contamination and prevent pollution. As part of an effort to solve marine environmental problem, BWM(Ballast Water Management) convention was adopted at a diplomatic conference on Feb. 13 2004. In order to comply harmoniously this convention by each country. This convention will be effective after 12 months from the date which 30 countries ratified accounting for more than 35% of the world merchant shipping volume. On Sep. 8 2016, Finland ratified this convention and effective condition was satisfied as 52 states and world merchant vessel fleet 35.1441%. Thus, after Sep. 8 2017, all existing vessels shall be equipped with BWTS(Ballast Water Treatment System) in accordance with D-2 Regulation, which physically handles ballast water from ballast water exchange system(D-1 Regulation). In this study, we analyzed in detail the optimal design method using the Risk Analysis and Evaluation technique which is mainly used in the manufacturing factory or the risky work site comparing with the traditional design concept method applying various criteria. The Risk Assessment Method is a series of processes for finding the Risk Factors in the design process, analyzing a probility of the accident and size of the accident and then quantifying the Risk Incidence and finally taking measures. In this study, this method was carried out for Electrolysis treatment type on DWT 180K Bulk Carrier using "HAZOP Study" method among various methods. In the Electrolysis type, 63 hazardous elements were identified.

A Study on the Sterilization Effect of Ballast Water according to the Combination of Types of Treatment Apparatus (선박평형수 처리장치의 조합에 따른 살균효과에 관한 연구)

  • Kang, Ah-Young;Kim, Sang-Pil;Song, Ju-Yeong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.412-417
    • /
    • 2015
  • The purpose of this study is to treat the ballast water by shear stress without an environmental pollution and to find out the optimal treatment conditions. The ballast water problem is issued up as the trade activated and the cargos mobilized. To improve this problem, International Marine Organization(IMO) make the rule about the ballast water treatment with specific restrictions. Although many countries have been studying about the ballast water treatment technology, there is almost no technology that can treat the microorganisms under $50{\mu}m$ without any secondary pollution. In this study, we tried to treat ballast water by applying shear stress as the physical treatment for the sterilization and tried to find out the optimal conditions including the 100% sterilizing rate and the best economic condition.

A study on the strategy of concerned parties with regard to the performance standards and implementation schedule of ballast water treatment systems (평형수처리장치 성능기준 및 시행시기 차이에 의한 관련 당사자들의 대응전략 연구)

  • Kim, Kyong-Min;Kim, Hoi-Jun;Ha, Weon-Jae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.3
    • /
    • pp.325-332
    • /
    • 2014
  • In installing ballast water treatment system, the cost of the system is high and many technical aspects are to be considered and also it takes significant time to retro-fitting on the existing ships. In addition, in the current circumstance which the Ballast Water Management Convention has not been entered into force, the 28th IMO Assembly adopted a resolution to mediate the implementation schedule of the treatment systems. In the mean time, California State and New York State have declared more stringent discharge requirements of ballast water and are planning to implement them earlier than the schedule of the Convention. In these circumstances, the implication in the difference between ballast water treatment system manufacturers and ship owners need to be considered. In this study, through the review on the considerations when installing the system onboard, stringent requirements of United States of America, and determent or mediated implementation schedules of Convention and California and New York States, the author would like to suggest the strategy of concerned parties for anticipated entrry into force of the Convention and implementation of the stringent requirements of United States of America.

Numerical Investigation on Freezing in Ballast Tank of Ship Navigating in Ice-bound Sea

  • Kang, Ho-Keun;Kim, Ki-Pyoung;Ahn, Soo-Whan
    • Journal of Power System Engineering
    • /
    • v.17 no.2
    • /
    • pp.95-102
    • /
    • 2013
  • For vessels operating in the cold climate regions, the ballast water inside or hopper tanks above the waterline may be frozen, starting at the top of the tank and at the side walls. Therefore, countermeasures against freeze-up of the ballast tank such as air-bubbling system, hot steam injecting system, heating coil system and water circulating system are taken to prevent freeze-up phenomenon; however, there are no rigorous investigations of anti-freezing to examine the effectiveness and validity of systems against freeze-up of the ballast tank, in which the temperatures are about $-25^{\circ}C$ (ambient air temperature) and $0^{\circ}C$ (sea water), respectively. In this paper, to ensure reasonable specifications for cold regions if the measures from the above-mentioned systems against freeze-up are effective, the phenomenon of ballast tank freeze-up is simulated and discussed in low temperature conditions. With the results using the commercial CFD code, CFX 14, the most cost-effective solution is conducted to prevent being frozen along the outer surface.

Marine Plankton in Ballast Water of Ship Entering Korea (한국에 입항한 선박 밸러스트 수에 존재하는 해양 부유생물)

  • Yoo, Jeong-Kyu;Song, Tae-Yoon;Hong, Hyun-Pyo;Jeong, Kyung-Mi;Myung, Chul-Soo
    • Ocean and Polar Research
    • /
    • v.28 no.1
    • /
    • pp.57-65
    • /
    • 2006
  • Various marine plankton were observed in the ballast water of vessels entering Incheon and Busan harbors. The ballast water of which age ranged from 2 to 54 days originated from the coastal waters of New Zealand, Taiwan, Singapore, Japan, Hong Kong and Pakistan, and from the Pacific Ocean. The total number of marine plankton taxa in 9 ballast tanks of different ships was 170: 90 phytoplankton, 24 protozoa and 56 zooplankton. The most diverse taxonomic groups were diatoms in phytoplankton, ciliates in protozoa and copepods in zooplankton. Classifying the specimens by size, above 50% of the number species of phytoplankton belonged to the size range between 50 and 150 Un. Protozoa and metazooplankton were found frequently in the size range between 50 and $120{\mu}m$ and 500 and $1,000{\mu}m$, respectively. The relationship between the species number and the age of ballast water was not significant. This is because of difference of filtration amounts derived from discordance of collecting samples. Among plankton observed in ballast water, some harmful algae and non-indigenous aquatic species were identified. Therefore, we need to investigate whether these species can inhabit in Korean coastal waters in further study.

Molecular Detection of Harmful Dinoflagellates (Dinophyceae) in Ballast Water (선박평형 수 내 유해 와편모조류(Dinophyceae)의 분자생물학적 검출)

  • Park, Tae-Gyu;Kim, Sung-Yeon
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.15 no.1
    • /
    • pp.36-40
    • /
    • 2010
  • Ballast water has been known as a major vector for global dispersal of toxic dinoflagellates and other microalgae. In this study, biodiversity in ships’ ballast water was examined using a dinoflagellate-oriented PCR primer set and species-specific real-time PCR. While motile dinoflagellates could be observe at very low cell densities by light microscopy,a wide range of dinoflagellate taxa including parasitic and phototrophic pico-dinoflagellates as well as harmful species to marine fish/shellfish was detected when techniques for cloning/sequencing of SSU rDNA of sample cells were used. Present result suggests that molecular methods including species-specific PCR primers may offer rapid and accurate detection of invasive species in ballast water.

Design of High-Current Inverter-type Rectifier for Electrolytic Disinfection of Ship Ballast Water (선박 평형수 처리용 대전류 인버터 방식의 정류기 설계)

  • Cho, Won-Woo;Kim, Jin-Young;Kim, In-Dong;Nho, Eui-Cheol;Goh, Gang-Woo;Bae, Sang-Bum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.430-439
    • /
    • 2011
  • As the import and export cargos across the world increase with global trade environments, the ecocide caused lots of small marine organisms in the ship's ballast water is a big issue. The implementation of the BWTS (Ballast water treatment system) thus needs low-voltage high-current rectifier for electrolytic disinfection. So this paper proposes a suitable high-current inverter-type rectifier for electrolytic disinfection of seawater and analyzes its output characteristics. It also suggests the practical design guidelines for the proposed rectifier in terms of power circuit and controller designs.

Effect of Electrochemical Treatment on the Chlorine Generation Efficiency of Ballast Water in the Brackish Zone (기수지역 선박평형수의 염소 생성 효율에 미치는 전기화학 처리의 영향)

  • Choi, Yong-Sun;Lee, You-Kee
    • Korean Journal of Materials Research
    • /
    • v.29 no.1
    • /
    • pp.16-22
    • /
    • 2019
  • Indirect oxidation using chlorine species oxidizing agents is often effective in wastewater treatment using an electrochemical oxidation process. When chlorine ions are contained in the wastewater, oxidizing agents of various chlorine species are produced during electrolysis. In a ballast water management system, it is also used to treat ballast water by electrolyzing seawater to produce a chlorine species oxidizer. However, ballast water in the brackish zone and some wastewater has a low chlorine ion concentration. Therefore, it is necessary to study the chlorine generation current efficiency at various chlorine concentration conditions. In this study, the chlorine generating current efficiency of a boron-doped diamond(BDD) electrode and insoluble electrodes are compared with various chloride ion concentrations. The results of this study show that the current efficiency of the BDD electrode is better than that of the insoluble electrodes. The chlorine generation current efficiency is better in the order of BDD, MMO(mixed metal oxide), $Ti/RuO_2$, and $Ti/IrO_2$ electrodes. In particular, when the concentration of sodium chloride is 10 g/L or less, the current efficiency of the BDD electrode is excellent.