• Title/Summary/Keyword: balancing order

Search Result 441, Processing Time 0.023 seconds

Optimal DG Placement in a Smart Distribution Grid Considering Economic Aspects

  • Buaklee, Wirote;Hongesombut, Komsan
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1240-1247
    • /
    • 2014
  • The applications of Distributed Generation (DG) in a smart distribution grid environment are widely employed especially for power balancing and supporting demand responses. Using these applications can have both positive and negative impacts on the distribution system. The sizing and location of their installations are the issues that should be taken into consideration to gain the maximum benefit from them when considering the economic aspects. This paper presents an application of the Bat Algorithm (BA) for the optimal sizing and siting of DG in a smart distribution power system in order to maximize the Benefit to Cost Ratio (BCR), subjected to system constraints including real and reactive power generation, line and transformer loading, voltage profile, energy losses, fault level as well as DG operating limits. To demonstrate the effectiveness of the proposed methodology and the impact of considering economic issues on DG placement, a simplify 9-bus radial distribution system of the Provincial Electricity Authority of Thailand (PEA) is selected for the computer simulation to explore the benefit of the optimal DG placement and the performance of the proposed approach.

Experimental Consideration for Vibration Noise, Heat Evaluation on High Speed Mixer (고속 교반기의 진동소음, 열특성 평가를 위한 실험적 고찰)

  • Lee, Jin-Kab
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1529-1534
    • /
    • 2008
  • Recently, mixers are being widely used in the display and semiconductor company in order to mix the chemical materials. The mixer normally consists of shaft, hub, reduction gear, and driving motor. It is one of the key design factors to evaluate the dynamic characteristics caused by the rotation. In this study, the dynamic characteristics of the high speed mixer, such as vibration, noise and thermal radiation, are verified by the experiment. Through the experiment, it is shown that the structural unbalance mass of high speed mixer is the important source of the severe vibrations and maximum temperature is mixer bowl.

Design and Implementation of School Affairs Management System using PHP on the Internet (인터넷 상에서 PHP를 이용한 학사관리 시스템의 설계 및 구현)

  • Moon, Jin-Yong;Koo, Yong-Wan
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.10
    • /
    • pp.3148-3154
    • /
    • 2000
  • In this paper. the design and implementationof the on-line registration system for the school affairs is described. The environments for the system configurations include a PC server under Linux Iperating System. Apache Web-server, and MySQL as database engine. In addition, PHP, which becomes a popular Internet server-based script language lately, is used to implement a real-time database. In order to avoid overload problems during short-term registration period, which deconstraces the typical surge of traffics, the proposed system is designed to minimize the unnecessary interfacing tasks. On administrator side task, the sytem is designed to have environments by separating the dechcated server that restricts the scope of specific database thasks. In doing so, it become possibal to build an optical system by distributing, balancing the transaction load, maintainimg the security and efficient administrative tasks.

  • PDF

Chopper Controller Based DC Voltage Control Strategy for Cascaded Multilevel STATCOM

  • Xiong, Lian-Song;Zhuo, Fang
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.576-588
    • /
    • 2014
  • The superiority of CMI (Cascaded Multilevel Inverter) is unparalleled in high power and high voltage STATCOM (Static Synchronous Compensator). However, the parameters and operating conditions of each individual power unit composing the cascaded STATCOM differ from unit to unit, causing unit voltage disequilibrium on the DC side. This phenomenon seriously impairs the operation performance of STATCOM, and thus maintaining the DC voltage balance and stability becomes critical for cascaded STATCOM. This paper analyzes the case of voltage disequilibrium, combines the operation characteristics of the cascaded STATCOM, and proposes a new DC voltage control scheme with the advantages of good control performance and stability. This hierarchical control method uses software to achieve the total active power control and also uses chopper controllers to enable that the imbalance power can flow among the capacitors in order to keep DC capacitor voltages balance. The operating principle of the chopper controllers is analyzed and the implementation is presented. The major advantages of the proposed control strategy are that the number of PI regulators has been decreased remarkably and accordingly the blindness of system design and debugging also reduces obviously. The simulation reveals that the proposed control scheme can achieve the satisfactory control goals.

A Study on the Electrical Characteristics of Battery Capacitor Applied to Photovoltaic Power System (태양광 시스템에 적용한 배터리 커패시터의 전기적 특성에 관한 연구)

  • Mang, Ju-Cheul;Yoon, Jung-Rag
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.12
    • /
    • pp.1740-1744
    • /
    • 2017
  • This paper describes the preparation and characteristics of a battery capacitor and module for solar power system. A cylindrical 30,000F battery capacitor ($60{\times}138mm$) was assembled by using the $LTO(Li_4Ti_5O_{12})$ electrode as an anode and $NMC(LiNiMnCoO_2)-LCO(LiCoO_2)$ as a cathode. The battery capacitor has reduced energy density and power density under high CC(constant current) and CP(constant power) conditions. Battery capacitor module (16V, 11Ah) was fabricated using an asymmetric hybrid capacitor with a capacitance of 30,000F. In order to determine the characteristics of the battery capacitor Module for solar power system, battery capacitor cells were connected in series with active balancing circuit. As a result of measuring the 100w LED lamp, it was discharged at the voltage of 15V~10V, and the compensation time at discharge was measured to be about 4979s. Experimental results show that it can be applied to applications related to solar power system by applying battery capacitor module.

A study on the Posture control of a two-wheeled mobile robot (양바퀴 이동로봇의 자세제어에 대한 연구)

  • Joo, Jin-Hwa
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.6
    • /
    • pp.587-593
    • /
    • 2017
  • In this paper, we propose a method to solve the difficulties in constructing an environment capable of practical training on the theoretical contents of robot control field. We make a two-wheeled mobile robot with Segway structure using LEGO block. In order to demonstrate the validity of using the developed robot as a practical application of advanced control theory of robotics education such as dynamic system and nonlinear system, the robot takes a stable posture while balancing the change of gravity during running. The results of the experiment are shown. By presenting the results, the robots made using the LEGO block are used for practical training of advanced control theory of robotics. It can be used as a tool.

A Study on the RTLS based Dynamic Planning of Yard Tractors in Container Terminals

  • Lee, Seok-Yong;Lee, Chul-Ho
    • Journal of Navigation and Port Research
    • /
    • v.31 no.2
    • /
    • pp.141-149
    • /
    • 2007
  • The competitiveness of container terminals hinges on minimizing the time vessels spend in port and on schedule services. Many previous researches on container terminals have tried to optimize the equipment allocation plan and to improve the activity of resources. Nevertheless, there have been few researches conducted on yard tractors, which move containers between the quay and the yard. The aim of this study is to propose the use of Real Time Location Systems (RTLS) based Dynamic Planning for yard tractors. Only RFID (Radio Frequency Identification) tags, which are attached to yard tractors, are able to support RTLS implementation. The system can provide real time job ordering in terms of load balancing using the information on location, in regards to the movement of yard tractors. This study will present the practical feasibility of RTLS, which can ultimately reduce the congestion of Hot Queues in container terminals. As a result, container terminals can be more productive and competitive. In order to accomplish the purpose of this study, we examined previous studies on the competitiveness of container terminals and summarized the potential of RTLS using RFID. In addition, we identified the role of yard tractors and proposed the two rules of Dynamic Planning for the yard tractors. We then fulfilled computational experiments on how yard tractors carrying containers by RTLS ordering Finally, the benefits and the implications of this study are discussed.

Predictive Factors of Turnover Intention in New Nurses (신규간호사의 이직의도에 미치는 영향요인)

  • Lee, Jeong Hwa;Noh, Hye Ran;Park, Ju Young
    • Journal of muscle and joint health
    • /
    • v.27 no.1
    • /
    • pp.50-60
    • /
    • 2020
  • Purpose: This study aimed to identify the effects of preceptor's leadership, preceptor-preceptee exchange relationship, and preceptee's self-leadership on newly hired nurses' turnover intention. Methods: Participants were 175 nurses working at general hospitals in D city. Data were collected from 164 nurses in May 2019 and were analyzed using multiple linear regression with SPSS/WIN 24.0 program. Results: Newly hired nurses' turnover intention was negatively correlated with preceptor's transactional leadership (r=-.23, p=.003), preceptor's emotional leadership (r=-.28, p<.001), preceptor-preceptee exchange relationship (r=-.34, p<.001), and preceptee's self-leadership (r=-.23, p=.004). The work unit (β=.35, p<.001), preceptor-preceptee exchange relationship (β=-.28, p=.002), present work experience (β=.27, p=.043), and marital status (β=-.19, p=.009) were significant predictors of the turnover intention (R2=.26, p<.001). Conclusion: Therefore, in order to reduce the degree of turnover of new nurses, improving the exchange relationship of preceptor-preceptee is required, and balancing between work and life should be considered especially for the married new nurses.

The Implementation of Current Compensation Controller in Driving Voltage type Converter considering the Unbalance of Reactor at the Source Side (전원측 리액터 불평형을 고려한 전압형 컨버터의 전류 보상 제어기 구현)

  • Chun Ji-Yong;Cho Yu-Hwan;Lee Geun-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.5 no.5
    • /
    • pp.413-420
    • /
    • 2004
  • In this paper, the control algorithm of DC source device for inverter starting is proposed and the control method for compensating unbalance system source on operating time in the voltage type PWM converter with driving and regenerative faculty is suggested. The maintaining method of balancing condition for converter of AC source is used the compensating unbalanced status by current control loop. In order to solve the problem which the unbalanced system control is used to leakage transformer not equaled reactance by each phase in rectifier system. The proposed H/W and control algorithm of rectifier system is contributed to minimize of device and rising efficiency.

  • PDF

Analysis of Air Flow Rate Distribution for the Bathroom Exhaust System in High-rise Buildings Using T-method (T-method를 이용한 고층 아파트 욕실 배기 시스템의 층별 유량분배 해석)

  • 문종선;강석윤;이승철;유호선;이재헌
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.3
    • /
    • pp.265-272
    • /
    • 2004
  • Based on the T-method, a new scheme for predicting air flow rate distribution in a bathroom exhaust system is developed. Introduction of individual duct route enables us to disintegrate a complicated multi-fan ductwork into a set of simultaneous single-fan subsystems. The scheme is validated via the analysis of a well-posed test problem, showing physical consistency. In order to demonstrate the utility and capability of our method, the bathroom ventilation system in a 20-story residential building is selected as an example. Under the typical design condition, the air flow rate of each exhaust fan at the balancing point is successfully predicted, and such information can lead to an engineering estimation for the overall system performance. While some deficiencies in ventilation are found at bathrooms at lower floors with 6mmAq-rated exhaust fans, they disappear over the whole building by using fans of enhanced static pressures, 7 and 8mmAq. Finally the present scheme seems to be useful for practical design of multi-branched, multi-fan ventilation systems.