• 제목/요약/키워드: balancing control

검색결과 636건 처리시간 0.029초

협심증 환자의 나이트레이트 정맥투여 시 두통완화를 위한 밸런스테이핑요법의 효과 (The effects of Balance Taping Therapy on Reducing Headache in Patients with Angina Pectoris Undergoing Nitrate IV Therapy)

  • 김경희;권미경;김남선;이규은;정명아;이근연;전은미
    • 임상간호연구
    • /
    • 제19권3호
    • /
    • pp.468-478
    • /
    • 2013
  • Purpose: The purpose of this study was to identify the effects of balancing taping therapy on reducing headache in patients with angina pectoris undergoing nitrate IV therapy. Methods: A non-equivalent control group non-synchronized design was used. A total of 50 patients with angina pectoris undergoing nitrate therapy at G hospital participated in the study. For measuring pain intensity, the Visual Analogy Scale (VAS) and Non-Verbal Pain Behavior Scale were used. Data were analyzed using SPSS 19.0 program. Results: No significant differences were observed between the experimental and control groups in pain intensity. However, the number of times of analgesics of experimental group was significantly lower than those of control group. Conclusion: Balance taping can be effective in pain for patients undergoing nitrate IV therapy. Therefore, utilizing the balance taping can be useful method to reduce headache in patients with angina pectoris during the IV therapy of nitrate.

A Stable Operation Strategy in Micro-grid Systems without Diesel Generators

  • Choi, Sung-Sik;Kang, Min-Kwan;Lee, Hu-Dong;Nam, Yang-Hyun;Rho, Dae-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.114-123
    • /
    • 2018
  • Recently, as one of the countermeasures to reduce carbon dioxide($CO_2$) for global warming problems, operation methods in micro-grid systems replacing diesel generator with renewable energy sources including wind power(WP) and photovoltaic(PV) system have been studied and presented in energetic manners. However, it is reported that some operation problems in micro-grid systems without diesel generator for carbon-free island are being occurred when large scaled WP systems are at start-up. To overcome these problems, this paper proposes an operation strategy in micro-grid systems by adapting control devices such as CVCF(constant voltage constant frequency) ESS(energy storage system) for constant frequency and voltage regulation, load control ESS for balancing demand and supply and SVC(static-var compensator) for reactive power compensation. From the simulation results based on the various operation scenarios, it is confirmed that the proposed operation strategy in micro-grid systems without diesel generators is a useful tool to perform a stable operation in micro-grid systems without diesel generator and also make a contribution to reduce carbon dioxide in micro-grid systems.

공항 수하물 처리시스템의 균형적인 흐름제어 기법 연구 (A Fair Flow Control For Baggage Handling System in Airport)

  • 김준범;김국화;채준재
    • 한국통신학회논문지
    • /
    • 제41권10호
    • /
    • pp.1317-1327
    • /
    • 2016
  • BHS는 공항 내 가장 복잡한 시스템중 하나이며, 높은 시스템 확장비용을 고려했을 때 효율적인 운영 시스템이 요구된다. 비효율적인 BHS 운영 시스템은 병목현상을 발생시켜 시스템 능력을 하락시키는 동시에 체크인시설의 뷸균형을 야기한다. 따라서 본 연구의 목적은 BHS 합류부의 병목현상을 제어함으로써 BHS와 체크인 구역의 효율성을 향상시키는 것에 있다. 데이터 네트워크에 사용하는 흐름제어 개념을 차용하여 새로운 로직을 제안하였으며, 시뮬레이션을 기반으로 컨베이어의 병목현상이 고객 대기열에 미치는 영향을 분석하였다.

지지면에 따른 한 발 서기 운동이 20대 대학생들의 동적 균형 능력과 배 근육 두께에 미치는 즉각적인 효과 비교 연구 (A Comparative Study on the Immediate Effect of Single Limb Stance Exercise According to the Supporting Surface on the Dynamic Balance Ability and Abdominal Muscle Thickness of College Students in Their Twenties)

  • 박한규;이경순;박진
    • 대한통합의학회지
    • /
    • 제9권1호
    • /
    • pp.1-11
    • /
    • 2021
  • Purpose : The purpose of this study was to investigate the effect of single limb stance exercise according to the support surface on dynamic balance ability and abdominal muscle thickness. Methods : We recruited 28 healthy subjects in this study. Subjects were assigned to 2 groups by matching method. The control group was 5 males and 9 females, and single limb stance exercise was performed on the stable support surface. The experimental group consisted of 6 males and 8 females, and trained to stand on the unstable support. During the single limb stance exercise, the dominant foot was set as the foot that appeared numerically through the exercise of the dynamic balance meter (Biorescue). Single limb stance exercise along the supporting surface was maintained for 15 seconds and then rested for 15 seconds. It was repeated 5 times. Particularly, the balance exercise on the unstable support surface was sufficiently practiced. Independent t test was performed for comparison between groups. Paired t test was performed to compare before and after each group. Results : There was no difference between the control group and the experimental group in the comparison of dynamic balance ability (p>.05). However, there were significant differences before and after exercise in both the control and experimental groups (p<.05). Similarly, in the comparison of abdominal muscle thickness, there was a significant difference within each group, especially internal oblique and transverse abdominis (p<.05), and no difference between groups (p>.05). Conclusion : Based on these results, although there was no difference between the groups, in the experimental group, numerical increase in dynamic balance ability and abdominal muscle thickness was confirmed. Therefore, single limb stance exercise on the unstable support surfaces activates core muscles and has a positive effect on dynamic balancing ability.

클러스터 시스템의 부하분산 알고리즘의 효율성 비교분석 (An Analysis and Comparison on Efficiency of Load Distribution Algorithm in a Clustered System)

  • 김석찬;이영
    • 한국정보과학회논문지:컴퓨팅의 실제 및 레터
    • /
    • 제12권2호
    • /
    • pp.111-118
    • /
    • 2006
  • 본 연구에서는 클러스터 시스템에 적용되는 새로운 부하할당 알고리즘을 기존의 알고리즘과 비교하여 분석하고자 한다. PWLC 알고리즘은 설정된 가중치 산정주기마다. 시스템의 부하를 감지하여, 각 서버에 가중치를 부여하여 다음 주기에 가중치에 의하여 부하를 분산시키는 알고리즘이다. PWLC 알고리즘과 DWRR 알고리즘을 가중치 산정주기를 변화시키면서 분산과 대기시간 등에 비교하였다. 가중치 산정주기가 너무 짧으면 시스템은 부하를 감지하는데 잉여부하가 소요될 수 있으며, 이와 반대로, 가중치 산정주기가 너무 길면 알고리즘 적용에 의한 부하할당이 비효율적으로 될 수 있다. PWLC 알고리즘이 DWRR 알고리즘보다. 더 효율적임을 알 수 있다.

Low-Voltage-Stress AC-Linked Charge Equalizing System for Series-Connected VRLA Battery Strings

  • Karnjanapiboon, Charnyut;Jirasereeamornkul, Kamon;Monyakul, Veerapol
    • Journal of Power Electronics
    • /
    • 제13권2호
    • /
    • pp.186-196
    • /
    • 2013
  • This paper presents a low voltage-stress AC-linked charge equalizing system for balancing the energy in a serially connected, valve-regulated lead acid battery string using a modular converter that consists of multiple transformers coupled together. Each converter was coupled through an AC-linked bus to increase the overall energy transfer efficiency of the system and to eliminate the problem of the unbalanced charging of batteries. Previous solutions are based on centralized and modularized topologies. A centralized topology requires a redesign of the hardware and related components. It also faces a high voltage stress when the number of batteries is expanded. Modularized solutions use low-voltage-stress, double-stage, DC-linked topologies which leads to poor energy transfer efficiency. The proposed solution uses a low-voltage stress, AC-linked, modularized topology that makes adding more batteries easier. It also has a better energy transfer efficiency. To ensure that the charge equalization system operates smoothly and safely charges batteries, a small intelligent microcontroller was used in the control section. The efficiency of this charge equalization system is 85%, which is 21% better than other low-voltage-stress DC-linked charging techniques. The validity of this approach was confirmed by experimental results.

Performance Analysis of a Novel Reduced Switch Cascaded Multilevel Inverter

  • Nagarajan, R.;Saravanan, M.
    • Journal of Power Electronics
    • /
    • 제14권1호
    • /
    • pp.48-60
    • /
    • 2014
  • Multilevel inverters have been widely used for high-voltage and high-power applications. Their performance is greatly superior to that of conventional two-level inverters due to their reduced total harmonic distortion (THD), lower switch ratings, lower electromagnetic interference, and higher dc link voltages. However, they have some disadvantages such as an increased number of components, a complex pulse width modulation control method, and a voltage-balancing problem. In this paper, a novel nine-level reduced switch cascaded multilevel inverter based on a multilevel DC link (MLDCL) inverter topology with reduced switching components is proposed to improve the multilevel inverter performance by compensating the above mentioned disadvantages. This topology requires fewer components when compared to diode clamped, flying capacitor and cascaded inverters and it requires fewer carrier signals and gate drives. Therefore, the overall cost and circuit complexity are greatly reduced. This paper presents modulation methods by a novel reference and multicarrier based PWM schemes for reduced switch cascaded multilevel inverters (RSCMLI). It also compares the performance of the proposed scheme with that of conventional cascaded multilevel inverters (CCMLI). Simulation results from MATLAB/SIMULINK are presented to verify the performance of the nine-level RSCMLI. Finally, a prototype of the nine-level RSCMLI topology is built and tested to show the performance of the inverter through experimental results.

Development of a Biped Walking Robot Actuated by a Closed-Chain Mechanism

  • Choi, Hyeung-Sik;Oh, Jung-Min;Baek, Chang-Yul;Chung, Kyung-Sik
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.209-214
    • /
    • 2003
  • We developed a new type of human-sized BWR (biped walking robot), named KUBIR1 which is driven by the closed-chain type of actuator. A new type of the closed-chain actuator for the robot is developed, which is composed of the four-bar-link mechanism driven by the ball screw which has high strength and high gear ratio. Each leg of the robot is composed of 6 D.O.F joints. For front walking, three pitch joints and one roll joint at the ankle. In addition to this, one yaw joint for direction change, and another roll joint for balancing the body are attached. Also, the robot has two D.O.F joints of each hand and three D.O.F. for eye motion. There are three actuating motors for stereo cameras for eyes. In all, a 18 degree-of-freedom robot was developed. KUBIR1 was designed to walk autonomously by adapting small 90W DC motors as the robot actuators and batteries and controllers are on-boarded. The whole weight for Kubir1 is over 90Kg, and height is 167Cm. In the paper, the performance test of KUBIR1 will be shown.

  • PDF

Transposable Elements and Genome Size Variations in Plants

  • Lee, Sung-Il;Kim, Nam-Soo
    • Genomics & Informatics
    • /
    • 제12권3호
    • /
    • pp.87-97
    • /
    • 2014
  • Although the number of protein-coding genes is not highly variable between plant taxa, the DNA content in their genomes is highly variable, by as much as 2,056-fold from a 1C amount of 0.0648 pg to 132.5 pg. The mean 1C-value in plants is 2.4 pg, and genome size expansion/contraction is lineage-specific in plant taxonomy. Transposable element fractions in plant genomes are also variable, as low as ~3% in small genomes and as high as ~85% in large genomes, indicating that genome size is a linear function of transposable element content. Of the 2 classes of transposable elements, the dynamics of class 1 long terminal repeat (LTR) retrotransposons is a major contributor to the 1C value differences among plants. The activity of LTR retrotransposons is under the control of epigenetic suppressing mechanisms. Also, genome-purging mechanisms have been adopted to counter-balance the genome size amplification. With a wealth of information on whole-genome sequences in plant genomes, it was revealed that several genome-purging mechanisms have been employed, depending on plant taxa. Two genera, Lilium and Fritillaria, are known to have large genomes in angiosperms. There were twice times of concerted genome size evolutions in the family Liliaceae during the divergence of the current genera in Liliaceae. In addition to the LTR retrotransposons, non-LTR retrotransposons and satellite DNAs contributed to the huge genomes in the two genera by possible failure of genome counter-balancing mechanisms.

Model Validation and Controller Design for Vibration Suppression of Flexible Rotor Using AMB

  • Soo Jeon;Ahn, Hyeong-Joon;Han, Dong-Chul
    • Journal of Mechanical Science and Technology
    • /
    • 제16권12호
    • /
    • pp.1583-1593
    • /
    • 2002
  • This paper discusses the model validation and vibration suppression of an AMB flexible rotor via additional LQG controller. The main difficulty in the vibration suppression of the flexible rotor using AMB is to realize a controller that can minimize resonance without injuring the stabilized rigid modes. In order to solve this problem, simple scheme for system modeling and controller design are developed. Firstly, the AMB flexible rotor is stabilized with a PID controller, which leads to a new stable rotor-bearing system. Then, authors propose the model validation procedure using measured open-loop frequency responses to obtain an accurate model of the AMB flexible rotor system. After that, LQG controller with modal weighting is designed to suppress resonances of the stable rotor-bearing system. Due to the poor controllability and observability of flexible modes compared to rigid ones, balancing of two Gramians is prerequisite for the fair LQG controller design. Simulation with step disturbance and experimental results of unbalance response up to 10,000 rpm verified the effectiveness of the proposed scheme.