• Title/Summary/Keyword: balance measurement system

Search Result 180, Processing Time 0.041 seconds

Development of Balance Measurement and Training System (평형감각 측정 및 훈련 시스템 개발)

  • Han, Young-Hwan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.3
    • /
    • pp.27-32
    • /
    • 2012
  • Balance measurement is widely used in fields of physiotherapy, neurology, sport medicine and rehabilitation medicine. This paper presents the development of balance measurement and rehabilitation training system. To this end, we have developed a prototype system using an 3-axis accelerometer sensor attached to the under surface of balance board. As a results, the system is stable and shows a good degree of balance function. Also, the various patterns for rehabilitation training can be added easily. This system can be used for daily balance monitoring and will contribute to increasing the effectiveness of training.

Double Electro-Magnetic Force Compensation Method for the Micro Force Measurement (미소 힘 측정을 위한 이중 전자기힘 보상방법)

  • 최임묵;우삼용;김부식;김수현
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.2
    • /
    • pp.104-111
    • /
    • 2003
  • Micro force measurement is required more frequently for a precision manufacturing and investment in fields of precision industries such as semiconductor, chemistry and biology, and so forth. Null balance method has been introduced as an alternative of a loadcell. Loadcells have advantages in aspects of low cost and easy manufacturing, but have also the limitation in resolution and sensitivity to environment variations. In this paper, null balance method is explained and the dominant parameters related to system performances are mentioned. Null position sensor, electromagnetic system and controller are investigated. Also, the characteristic experiment is carried out in order to estimate the resolution and the measurement range. In order to overcome the limitation by the drift of position sensor and the performance of controller, double electromagnetic force compensation method is proposed and experimented. After controlling and filtering, the resolution under $\pm$ 1mg and measurement range over 300g could be obtained.

MSBS-SPR Integrated System Allowing Wider Controllable Range for Effective Wind Tunnel Test

  • Sung, Yeol-Hun;Lee, Dong-Kyu;Han, Jong-Seob;Kim, Ho-Young;Han, Jae-Hung
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.18 no.3
    • /
    • pp.414-424
    • /
    • 2017
  • This paper introduces an experimental device which can measure accurate aerodynamic forces without support interference in wide experimental region for wind tunnel test of micro aerial vehicles (MAVs). A stereo pattern recognition (SPR) method was introduced to a magnetic suspension and balance system (MSBS), which can eliminate support interference by levitating the experimental model, to establish wider experimental region; thereby MSBS-SPR integrated system was developed. The SPR method is non-contact, highly accurate three-dimensional position measurement method providing wide measurement range. To evaluate the system performance, a series of performance evaluations including SPR system measurement accuracy and 6 degrees of freedom (DOFs) position/attitude control of the MAV model were conducted. This newly developed system could control the MAV model rapidly and accurately within almost 60mm for translational DOFs and 40deg for rotational DOFs inside of $300{\times}300mm$ test section. In addition, a static wind tunnel test was conducted to verify the aerodynamic force measurement capability. It turned out that this system could accurately measure the aerodynamic forces in low Reynolds number, even for the weak forces which were hard to measure using typical balance system, without making any mechanical contact with the MAV model.

Mass-estimation Algorithm by Vibration Response Measurement of Dynamic Balance (동적 저울의 진동응답 측정에 의한 질량 추정 알고리즘)

  • 김병삼
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.5
    • /
    • pp.71-78
    • /
    • 2000
  • Quickness and precision are the two most important requirements for an industrial scale used in production lines. In this paper, a new approach, "Mass-estimation algorithm by vibration-response measurement of dynamic balance", is presented to improve some of drawbacks in conventional scales. The system, consisted of velocity and displacement sensors, spring scale, analog-digital converter and microcomputer, is based on full utilization of dynamic mass measurement of velocity and displacement via microcomputer-assisted real time monitoring. The resulting system, when combined with appropriate mass estimation algorithm software, has shown its effectiveness in terms of two desirable characteristics required.

  • PDF

Test-retest Reliability of Balance Tests in Older Adults (노인들에 대한 균형검사의 검사-재검사 신뢰도)

  • Kang, Soon-Hee
    • Journal of Korean Physical Therapy Science
    • /
    • v.16 no.4
    • /
    • pp.49-57
    • /
    • 2009
  • Background: The purpose of this study was to assess the test-retest reliability of balance measurements in older adults using balance measurement system(Good Balance). Methods: The subjects consisted of 49 female and 20 male in community-dwelling older adults. This study used a repeated-measure design. Each subject completed all the different tests once and they were then repeated with 2 minutes in between. Repeated two-ways analysis of variance(ANOVA), representing two test times and both sexes, was calculated for each of the two dependent variables. Intraclass correlation coefficients(ICCs) were used to assess the test-retest reliability. Results: 1) There was not significant difference between test and retest for mediolateral sway speed and anterioposterior sway speed under conditions of normal standing with eyes open, normal standing with eyes closed and semitandem standing with eyes open. There was not significant difference between males and females for mediolateral sway speed and anterioposterior sway speed under conditions of normal standing with eyes open, normal standing with eyes closed and semitandem standing with eyes open. There were not the interaction effects between genders and test time under three conditions. 2) The reproducibility between test and retest was excellent for anterioposterior sway speed(ICC=.77) under condition of normal standing with eyes open, and for mediolateral sway speed(ICC=.76) and anterioposterior sway speed(ICC=.84) under condition of semitandem standing with eyes open. The reproducibility between test and retest was fair to good for mediolateral sway speed(ICC=.64) under condition of normal standing with eyes open, for mediolateral sway speed(ICC=.63) and anterioposterior sway speed(ICC=.75) under condition of normal standing with eyes closed. Conclusion: Balance tests in older adults using balance measurement system(Good Balance) demonstrated acceptable levels of reliability.

  • PDF

A Development of Multi-Channel Acupuncture Point Balance Measurement System (다채널 경혈평형 계측 시스템 구현에 관한 연구)

  • Kim, Chang-Mo;Kim, Eung-Soo;Han, Soon-Chen;Kim, Jung-Kuk;Huh, Woong
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2903-2906
    • /
    • 2003
  • In this paper, we developed a multichannel acupuncture point balance measurement system that measures skin resistances at various acupuncture points to evaluate the balancing state of the meridian. The system consists of 16 channel resistance-voltage converter, signal processing part for signal amplification and filtering, A/D conversion part, micro-controller part, and data processing part. Compared to the previously developed 1 channel or 4 channel systems, it is found that the 16 channel system can measure the skin resistances of 16 acupuncture points, simultaneously, providing various clinical information such as balance and variation of the resistance value.

  • PDF

Investigation about anterior.posterior plantar pressure and right.left body balance by insole height (깔창의 높이에 따른 전후 압력 분포와 좌우 균형에 관한 연구)

  • Jo, Deok-Sang;Goh, Hyun-Gon;Cha, Seung-Yong;Kim, Mi-Ri;Hong, Bo-Ram;Seo, Ji-Hee;Jeon, Mi-Hee;Song, Mi-Ri;Lee, Hyo-Suk;Kim, Min-Jun;Kim, Hyoung-Su
    • Journal of Korean Physical Therapy Science
    • /
    • v.19 no.1
    • /
    • pp.39-46
    • /
    • 2012
  • Purpose : The purpose of this study was to investigate the effect of body balance according to insole height and to provide basic information about body balance by insole height. Method : We examed 40 university students who had healthy body without balance impairment. Plantar pressure was measured by EMED system and the measurement of MTD balance used the MTD-balance master in static stance posture. Both of equipments are various measurement method. We measured plantar pressure and MTD balance each three different height insole(0cm, 3cm, 7cm) and each trial was 30 second in duration. Result : The results were as follows : 1) It showed significantly differences between bare foot and height insole. The anterior plantar pressure with 3cm or 7cm insole were more higher than bare foot(P<.05). 2) There were no significantly differences between barefoot and height insole with MTD-balance master(P<.05). Conclusion : In conclusion, the measurement of MTD balance showed right and left balance ability didn't change by insole height, but plantar pressure was moved on anterior side of foot so we could know insole's height cause the effect to anterior and posterior balance ability.

  • PDF

Stabilization of Water Balance of Closed Cooling Water System with Orifice (오리피스를 통한 기기냉각수 계통 Water Balance 정상화)

  • Lee, Sung Gun;Park, Jong Hwan;Lee, Eun Su
    • Plant Journal
    • /
    • v.13 no.4
    • /
    • pp.38-40
    • /
    • 2017
  • This study is for stabilization of the water balance of the closed cooling water system. The pipe network analysis program is used for the water balance review, and the resistance factor correction is performed through the field measurement with the ultrasonic flowmeter to improve the reliability of the pipe network software. Based on this, it is aimed to derive optimal driving method through various case simulations.

  • PDF

PERUPS (PERFORMANCE UPGRADE SYSTEM) FOR ON-LINE PERFORMANCE ANALYSIS OF A NUCLEAR POWER PLANT TURBINE CYCLE

  • KIM SEONGKUN;CHOI KWANGHEE
    • Nuclear Engineering and Technology
    • /
    • v.37 no.2
    • /
    • pp.167-176
    • /
    • 2005
  • We developed the PERUPS system to aid the on-line performance analysis for the turbine cycle of the YongGwang 3 and 4 nuclear power plants. Procedure of measurement validation is included in the performance calculation to obtain heat balance. Precision of on-line performance calculation is increased via practical modifications of standard calculation algorithms based on the PTC (Performance Test Code). The proposed system also provides useful Web-based aids for performance analysis, including performance data management, a graphic viewer for heat balance and turbine expansion lines, and synthesized reports of performance.

Development of a oscillating frequency measurement and adjustment system of a balance wheel of Mechanical Timer (기계식 타이머 밸런스 휠의 진동 주파수 측정 및 조정 장비의 개발)

  • Lee, D.J.;Park, S.B.;Ahn, J.H.
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.879-883
    • /
    • 2000
  • A system for measuring and adjusting the oscillating frequency of a balance wheel whick determins the accuracy of mechanical timers. The balance wheel oscillates rotatively suspended by a hair spring which is welded at the other end to the pivot tube. The natural oscillatory frequency of the balance wheel is determined by the length of hairspring from the balance wheel to the point if other parameters the length in the torsional oscillation model are not changed, so the frequency of the balance wheel can be adjusted to meet a requirement by the adjustment of the hairspring length using ultrasonic welding. And the movement of wheel teeth is measured in realtime by a high speed photo fiber sensor and Auto Correlation is used to find a more accurate oscillation period from the measured signal with some variations.

  • PDF