• 제목/요약/키워드: backscattered ultrasound

검색결과 13건 처리시간 0.023초

Ultrasound Backscattering from Erythrocyte Aggregation of Human, Horse and Rat Blood under Rotational Flow in a Cylindrical Chamber

  • Nam, Kweon-Ho;Paeng, Dong-Guk;Choi, Min-Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • 제25권4E호
    • /
    • pp.159-165
    • /
    • 2006
  • Human, horse and rat bloods in a cylindrical chamber where flow was controlled by a stirring magnet were used for studying red blood cell aggregation. Ultrasound backscattered powers from blood were obtained from the backscattered signals measured by a 5 MHz focused transducer in a pulse-echo setup. The experimental results showed the differences in red blood cell (RBC) aggregation tendency among the three mammalian species with an order of horse > human > rat. The ultrasound backscattered power decreased with stirring speed in human and horse blood, but no variations were observed in rat blood. Sudden flow stoppage led to the slow increase of the backscattered power for human and horse blood. There was no self-aggregation tendency in rat blood. The enveloped echo images showed the spatial and temporal variations of RBC aggregations in the cylindrical chamber. These observations from the different mammalian species may give a better understanding of the mechanism of RBC aggregation.

초음파 영상을 이용한 고강도 집중 초음파 빔 시각화 (High-intensity focused ultrasound beam path visualization using ultrasound imaging)

  • 송재희;장진호;유양모
    • 한국음향학회지
    • /
    • 제39권1호
    • /
    • pp.16-23
    • /
    • 2020
  • 고강도 집중 초음파(High-Intensity Focused Ultrasound, HIFU) 치료에서 HIFU 초점의 효과적인 위치 파악은 안전한 치료 계획을 개발하는 데 중요하다. 자기 공명 영상 유도 HIFU(Magnetic Resonance Imaging guided HIFU, MRIgHIFU)는 HIFU 초점을 영상화하여 치료 중에 초음파 경로를 시각화 할 수 있지만 초음파 이미징 유도 HIFU(Ultrasound imaging guided HIFU, USIgHIFU)에서는 어려움이 있다. 본 연구에서는 USIgHIFU에 대해 HIFU 초점을 영상화할 수 있는 실시간 초음파 빔 시각화 기법을 제시 하였다. 제안 된 방법에서, 음향 강도(Ispta < 720 mW/㎠) 아래의 이미징 초음파 변환자의 동일한 중심 주파수를 갖는 짧은 펄스가 HIFU 변환기를 통해 전송되고, HIFU 빔 경로를 시각화하기 위해 수신 신호는 동적 수신 포커싱 및 후속 에코 처리를 거쳤다. 소 혈청 알부민 젤 팬텀을 이용한 생체외 실험으로부터, HIFU 빔 경로는 낮은 음향 강도 (Ispta = 94.8 mW/㎠)에서도 명확히 영상화 할 수 있었고 HIFU 초점은 손상이 생성되기 전에 성공적으로 시각화하였다. 이 결과는 제안 된 초음파 빔 경로 시각화 방법이 USIgHIFU 치료에서 원치 않는 조직 손상을 최소화하면서 실시간으로 HIFU 초점을 영상화하는 데 사용될 수 있음을 나타낸다.

위상 보상과 가중치 평균을 이용한 의료 초음파 신호의 주파수 특성 추출 방법 (Extraction Method of Ultrasound Spectral Information using Phase-Compensation and Weighted Averaging Techniques)

  • 김형석;이준환
    • 한국정보통신학회논문지
    • /
    • 제14권4호
    • /
    • pp.959-966
    • /
    • 2010
  • 정량적 초음파 분석(Quantitative Ultrasound Analysis)은 반향된 초음파 신호의 짧은 시간 간격의 주파수 성분을 추출하여 개별 초음파 지수의 값을 예측한다. 따라서 반향 신호의 정확한 주파수 특성 추출은 분석의 정확도와 정밀도 향상에 기본이 된다. 본 논문에서는 초음파 지수의 정량적인 예측 및 분석에 이용할 수 있는, 짧은 시간 간격의 반향 신호의 주파수 특성 추출 방법을 제안한다. 제안된 알고리듬은 인접한 반향 초음파 신호간의 위상 차이를 보상하고, 동일 반향 깊이를 가지는 작은 영역의 신호를 가중치 평균함으로써 보다 정확한 주파수 특성을 추출한다. 컴퓨터 모의 실험을 통한 수치 분석 결과, 제안된 알고리듬은 일반적인 주파수 추출 알고리듬보다 정확한 예측 결과를 보였으며, 예측 결과의 정밀도도 10% 이상 향상되었다.

수중 초음파를 이용한 적조 플랑크톤의 후방산란 특성 (Characteristics of Backscattering of Harmful Algae Using Underwater Ultrasound)

  • 김은혜;복태훈;나정열;팽동국
    • 한국음향학회지
    • /
    • 제24권8호
    • /
    • pp.447-453
    • /
    • 2005
  • 수중 초음파 (5, 10, 15 MHz)를 사용하여 적조 플랑크톤 Cochlodinium polykrikoides (식물 플랑크톤, 편모조류)의 후방산란 특성을 파악하기 위한 음향 실험을 실시하였다 적조 산란체의 적조주의보 (300 cells/a) 보다 적은 양의 개체 수 변화를 탐지하였고, 개체군 밀도와 후방 산란신호와의 상관관계를 시간영역에서와 주파수 영역에서 확인하였다. 또한, fluid-sphere model[1]을 이용한 이론적인 체적 산란강도를 계산하여 실측 체적 산란강도와 비교한 결과가 잘 일치하였다.

협대역 초음파 신호를 이용한 시간 영역에서의 감쇠 지수 예측 (Time-domain Estimation Algorithm for Ultrasonic Attenuation using Narrow-filtered Signals)

  • 심재윤;허돈;김형석
    • 전기학회논문지
    • /
    • 제65권11호
    • /
    • pp.1887-1893
    • /
    • 2016
  • The VSA(Video Signal Analysis) method is the time-domain approach for estimating ultrasonic attenuation which utilizes the envelop signals from backscattered rf signals. The echogenicity of backscattered ultrasonic signals, however, from deeper depths are distorted when the broadband transmit pulse is used and it degrades the estimation accuracy of attenuation coefficients. We propose the modified VSA method using adaptive bandpass filters according to the centroid shift of echo signals as a pulse propagates. The technique of dual-reference diffraction compensation is also proposed to minimize the estimation errors because the difference of attenuation properties between the reference and sample aggravates the estimation accuracy when the differences are accumulated in deeper depth. The proposed techniques minimize the distortion of relative echogenicity and maximize the signal-to-noise ratio at the given depth. Simulation results for numerical tissue-mimicking phantoms show that the Rectangular-shaped filter with the appropriate center frequency exhibits the best estimation performance and the technique of the dual-reference diffraction compensation dramatically improves accuracy for the region after the beam focus.

표면결함유형이 초음파 후방산란 프로파일에 미치는 영향 (Effect of Surface Flaw Type on Ultrasonic Backscattering Profile)

  • 권성덕;윤석수
    • 비파괴검사학회지
    • /
    • 제21권6호
    • /
    • pp.658-662
    • /
    • 2001
  • 후방산란된 초음파의 입사각 의존성을 이용한 표면 결함유형의 평가가 시도되었다. 평탄한 유리위에 순수한 홈, 구리로 채워진 홈, 표면위 붙여진 구리선등의 표면결함 시편에 대한 후방산란 프로파일은 제 1 임계각에서 종파의 산란과 관련된 새로운 프로파일을 보여주었다. 결함에 의한 산란효과가 클수록 후방프로파일들의 정점 위치는 작게 나타났으며 후방복사 프로파일과 정점 위치에서의 파열의 모양은 결함의 유형과 위치에 따라 누수파와 산란파의 복합적 요인에 의해 다른 형태를 보여주었다.

  • PDF

펄스 초음파 도플러 속도계의 제작에 관한 연구 (Construction of Ultrasound Pulsed Doppler Velocimeter)

  • 현석봉;김수용;이재수
    • 한국의학물리학회지:의학물리
    • /
    • 제5권1호
    • /
    • pp.25-39
    • /
    • 1994
  • 심장 벽의 운동속도와 혈관내 혈구의 유속을 측정하기 위해, 단일 채널 3.1MHz 펄스 도플러 속도계를 제작하였다. 도플러 속도계에 사용된 초음파 펄스의 폭과 펄스 반복주파수(PRF)는 각각 1$\mu$s과 6kHz이고, 후방 산란된 반향신호의 도플러 편이는 완전간섭성(coherent) 복조방식을 이용하여 위상 측정기에 감지된다. 위상 측정기의 출력신호로부터 레인지 게이트와 샘플 홀더, 대역여파기를 이용하여 작은 영역내에 있는 초음파 산란체의 평균속도에 해당하는 도플러 신호가 얻어진다. 도플러 신호의 평균 주파수는 영점교차의 카운터에 의해 측정되며 시간의 함수로 산란체의 순간 속도를 디스플레이한다. 채널 수와 거리 분해능을 증가시키면 혈관내의 혈류속도 분포도와 총 유량 그리고 혈류가속도를 측정할 수 있다.

  • PDF

적응 대역필터를 이용한 의료 초음파 감쇠 예측 (Estimation of Medical Ultrasound Attenuation using Adaptive Bandpass Filters)

  • 허서원;이준환;김형석
    • 전자공학회논문지SC
    • /
    • 제47권5호
    • /
    • pp.43-51
    • /
    • 2010
  • 의료 초음파 신호의 인체내 감쇠지수는 검사대상 조직의 병리학적 특성을 반영할 뿐 아니라 다른 여러 의료 초음파 지수들의 정확한 예측을 위해 선행하여 측정해야 하는 중요한 정량적 정보 중 하나이다. 그러나 초음파 감쇠지수의 주파수 선택적 감쇠특성을 이용한 주파수 영역에서의 정량적 감쇠지수 예측 방법은 계산량이 많아 실시간 적용에 많은 어려움이 있고, 상대적으로 계산량이 적은 시간 영역의 감쇠지수 예측 방법은 전송 펄스의 회절효과를 잘 보상하지 못하는 단점이 있다. 표준 반향신호를 이용하여 전송 펄스의 회절효과를 보상하는 시간 영역의 예측 알고리듬인 VSA(Video Signal Analysis) 방법은 광대역 펄스를 이용하는 경우, 원거리에서 반향된 신호의 왜곡이 발생하여 예측 정확도가 저하되는 단점이 있다. 본 논문에서는 그 단점을 해결하기 위해 적응 대역필터를 이용한 초음파 감쇠지수 예측 알고리듬을 제안한다. 제안된 방식은 반향 경로를 따라 누적된 신호 감쇠를 고려하여 적응 대역필터의 중심 주파수를 이동시킴으로써, 기존의 고정 대역필터를 사용하는 방법보다 예측 정확도와 정밀도를 높인다. 인체 조직의 초음파 반향특성을 모방한 컴퓨터 모의실험과 실제 TM(tissue-mimicking) phantom을 이용한 실험에서, 광대역 전송 펄스를 사용하는 경우보다 반향 깊이에 따른 상대적 echogenicity의 왜곡이 크게 감소하여 평균적으로 예측 감쇠지수의 정확도가 5.1% 향상되었고, 예측 편차도 기존의 방법에 비해 46.9% 감소되었다.

베릴륨 표면확산 층을 가진 지르코늄 판재에서의 후방산란 프로파일 (Ultrasonic Backscattering Profiles from Zirconium Plate with Beryllium Diffusion Layer)

  • 황용화;최현옥;박춘호;이영호;권성덕
    • 비파괴검사학회지
    • /
    • 제23권4호
    • /
    • pp.342-348
    • /
    • 2003
  • Zr(1.32mm) 판재 위 $Be-Zr(100{\mu}m)$ 합금층의 평가를 목적으로 후방산란 초음파 의 입사각 의존성인 프로파일이 여러 입사위치에서 측정되었다. 누설 램(Lamb)파로부터 후방복사된 초음파 프로파일에는 4개의 주요 세부 프로파일이 발견되었다. 세부프로파일들의 정점각과 정점세기는 Be 확산층의 강화효과로 인해 감소하였다. 세부 프로파일들의 존재와 변화가 시편재질의 음향학적 특성, 램파모드들의 군속도 집단적 변화 그리고 표면파의 누설율 차이 등으로 설명되었다 판재 위 얇은 확산층의 평가를 위한 유용한 평가 기법으로 판재로부터의 후방복사 세부 프로파일이 제안되었다.

레일리각 근처에서 도색된 거친 표면으로부터 후방 산란된 초음파 (Ultrasonic Backscattering on Painted Rough Surface at near Rayleigh Angle)

  • 권성덕;권용규;윤석수
    • 비파괴검사학회지
    • /
    • 제24권1호
    • /
    • pp.1-7
    • /
    • 2004
  • [ $1.71{\mu}m$ ] 범위의 표면 거칠기를 가진 철 시편에 대해 물속에서 후방산란된 초음파의 입사각 의존성(프로파일)이 측정되었다. 거칠기가 도색에 의해 숨겨졌을 때 수직 프로파일은 거칠기에 대한 분별력이 사라졌으나 레일리 각 근처에서의 후방산란 프로파일은 거칠기 의존성을 여전히 보여주었다. 레일리 각에서 직접 복사된 프로파일 세기는 거칠기와 비례하였고 코너에서 반사되어 되돌아오는 표면파로부터의 후방복사의 세기는 거칠기와 반비례하였다. 도색 처리된 시편에서 0.03 파장 이하의 직접 후방복사에서도 선형성이 관찰되었고 주기적 거칠기에 의해 발생한 비정상 저면 다중반사 현상이 사라졌다.