• 제목/요약/키워드: back side temperature

검색결과 74건 처리시간 0.027초

고효율 후면 전극형 태양전지를 위한 나노 Paste의 적용에 대한 연구 (The application of Nano-paste for high efficiency back contact Solar cell)

  • 남동헌;이규일;박용환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.53.2-53.2
    • /
    • 2010
  • In this study, we focused on our specialized electrode process for Si back-contact crystalline solar cell. It is different from other well-known back-contact cell process for thermal aspect and specialized process. In general, aluminum makes ohmic contact to the Si wafer and acts as a back surface reflector. And, silver is used for low series resistance metal grid lines. Aluminum was sputtered onto back side of wafer. Next, silver is directly patterned on the wafer by screen printing. The sputtered aluminum was removed by wet etching process after rear silver electrode was formed. In this process, the silver paste must have good printability, electrical property and adhesion strength, before and after the aluminum etching process. Silver paste also needs low temperature firing characteristics to reduce the thermal budget. So it was seriously collected by the products of several company of regarding low temperature firing (below $250^{\circ}C$) and aluminum etching endurance. First of all, silver pastes for etching selectivity were selected to evaluate as low temperature firing condition, electrical properties and adhesive strength. Using the nano- and micron-sized silver paste, so called hybrid type, made low temperature firing. So we could minimize the thermal budget in metallization process. Also the adhesion property greatly depended on the composition of paste, especially added resin and inorganic additives. In this paper, we will show that the metallization process of back-contact solar cell was realized as optimized nano-paste characteristics.

  • PDF

적외선체열촬영(赤外線體熱撮影)(DITI)분석(分析)을 통(通)한 요각통(腰脚痛) 환자(患者)의 임상적(臨床的) 고찰(考察) (Clinical Study on Yogaktong Patients by Analysing Digital Infrared Thermal Imaging)

  • 김동일;조명제;박쾌환
    • Journal of Acupuncture Research
    • /
    • 제17권3호
    • /
    • pp.199-207
    • /
    • 2000
  • Objectives : Yogaktong is the general term of lowback and sciatic pain. Simplely this is not for the syndrom or illiness but for the symptoms. In the field of western medicine, it's difficult to find out the cause and to be objective when the patient feel back and sciatic pain without HNP of L-spine. Methods : To get objective yogaktomg symptoms I did this study. This is the case study of 103 patients who felt yogaktomg, and had taken DITII(Digital Infrared Thermal Imaging) at department of acupuncture and moxibustion in Conmaul Oriental medical hospital from september 1, 1998 to august 30, 1999. Results : The temperature raised 53.4% at center of lowback. There is a temperature differance on both legs, in 70.73% of patients the pain side of leg is lower temperature than the other side. Conclusions : Generally, DITI of patients who have lowback and sciatic pain is shown increasing temperature in center of lowback, decreasing temperature in pain side of leg.

  • PDF

An Effective Control Scheme of a Back-to-Back Converter with Shunt-Connected HTS SMES for Frequency Regulation of an Islanded Microgrid

  • Dinh, Minh-Chau;Park, Minwon;Kim, Gyeong-Hun;Yu, In-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.1119-1124
    • /
    • 2014
  • High temperature superconducting magnetic energy storage (HTS SMES) is known as an effective solution to significantly decrease the voltage and power fluctuations of grid connected wind power generation system (WPGS). This paper implements an effective control scheme of a back-toback converter with shunt-connected HTS SMES for the frequency regulation of an islanded microgrid. The back-to-back converter is used to connect the WPGS to the grid. A large-scale HTS SMES is linked to the DC side of the back-to-back converter through a two-quadrant DC/DC chopper. An adaptive control strategy is implemented for the back-to-back converter and the two-quadrant DC/DC chopper to improve the efficiency of the whole system. The performance of the proposed control system was evaluated in a test power system using PSCAD/EMTDC. The simulation results clearly show that the back-to-back converter with shunt-connected HTS SMES operates effectively with the proposed control strategy for stabilizing the power system frequency fluctuations.

A Study on Blister Formation and Electrical Characteristics with Varied Annealing Condition of P-doped Amorphous Silicon

  • 최성진;김가현;강민구;이정인;김동환;송희은
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.346.2-346.2
    • /
    • 2016
  • The rear side contact recombination in the crystalline silicon solar cell could be reduced by back surface field. We formed polycrystalline silicon as a back surface field through crystallization of amorphous silicon. A thin silicon oxide applied to the passivation layer. We used quasi-steady-state photoconductance measurement to analyze electrical properties with various annealing condition. And, blister formed on surface of wafer during the annealing process. We observed the blister after varied annealing process with wafer of various surface. Shape and density of blister is influenced by various annealing temperature and process time. As the annealing temperature became higher, the average diameter of blister is decreased and total number of blister is increased. The sample with the $600^{\circ}C$ annealing temperature and 1 min annealing time exhibited the highest implied open circuit voltage and lifetime. We predicted that the various shape and density of blister affects the lifetime and implied open circuit voltage.

  • PDF

기능적인 하지길이 차이에 따른 족저압 변화가 족부체열에 미치는 영향 (The Foot Pressure Change Caused by Functional Leg Length Having an Effect on the Foot Temperature)

  • 김민주;김주연;이혜원;임주연;하현진;안진호
    • 대한통합의학회지
    • /
    • 제1권2호
    • /
    • pp.37-46
    • /
    • 2013
  • Purpose : The purpose of the research was to analyze foot pressure, foot temperature, and correlation between foot pressure and foot temperature to grasp impact on foot pressure and body temperature distribution chart depending on functional difference of leg length. Method : After measuring leg length, put 15 students whose functional difference of leg length was over 10mm to difference group and 15 students whose functional difference of leg length was under 5mm to normal group and categorize soles of foot into 6 sections of hallux head, 1st metatarsal head, 2-4 metatarsal head, 5 metatarsal head, lateral heel, and then measure by foot pressure analyzer to analyze characteristic of pressure distribution and classify into front of the lower leg, back of the lower leg, soles of foot and measure by body temperature analyzer to analyze by checking body temperature. Result : Weight difference depending on foot pressure and body temperature was bigger when functional difference of leg length was bigger, and it could be confirmed that foot pressure and body temperature of short leg side were higher than those of short leg side. Thus, if difference exists in leg length, weight load on short leg side increases which results in higher foot pressure and body temperature, therefore enabling an assumption that mechanical problem will occur in short leg. Conclusion : When functional leg length inequality, weight bearing and pressure was getting high as a result, temperature was getting high in short leg.

정전척 온도분포 개선을 위한 냉각수 관로 형상 (Coolant Path Geometry for Improved Electrostatic Chuck Temperature Variation)

  • 이기석
    • 반도체디스플레이기술학회지
    • /
    • 제10권4호
    • /
    • pp.21-23
    • /
    • 2011
  • Uniformity of plasma etching processes critically depends on the wafer temperature and its distribution. The wafer temperature is affected by plasma, chucking force, He back side pressure and the surface temperature of ESC(electrostatic chuck). In this work, 3D mathematical modeling is used to investigate the influence of the geometry of coolant path and the temperature distribution of the ESC surface. The model that has the coolant path with less change of the cross-sectional area and the curvature shows low standard deviation of the ESC surface temperature distribution than the model with the coolant path of the larger surface area and more geometric change.

복사열에 노출된 소방용 방수복의 열적 특성에 관한 연구 (Study on the Thermal Characteristics of the Fire Fighter's Waterproof Clothing Exposed to the Radiation Heat)

  • 방창훈
    • 한국화재소방학회논문지
    • /
    • 제17권1호
    • /
    • pp.21-25
    • /
    • 2003
  • 본 연구에서는 복사열에 노출된 소방용 방수복의 열적 특성에 대한 실험을 수행하였다. 실험결과 소방용 방수복의 노출시간에 따른 표면의 온도상승은 노출거리가 가까울수록 급격히 일어났다. 또한 복사열유속이 클수록 표면의 온도가 높으며, 정상상태 도달시간은 짧게 나타났다. 소방용 방수복의 노출거리가 멀어질수록 표면의 온도는 급격히 감소하며, 전면과 후면의 온도차도 감소하였다. 복사열유속이 증가할수록 안전노출거리가 증가하였다. 따라서 소방대원의 안전을 위해서는 복사열원으로부터 일정거리이상 떨어져 작업하여야 할 것으로 사료된다.

후면 형상에 따른 결정질 실리콘 태양전지의 후면전계 형성 및 특성 (Back Surface Field Properties with Different Surface Conditions for Crystalline Silicon Solar Cells)

  • 김현호;김성탁;박성은;송주용;김영도;탁성주;권순우;윤세왕;손창식;김동환
    • 한국재료학회지
    • /
    • 제21권5호
    • /
    • pp.243-249
    • /
    • 2011
  • To reduce manufacturing costs of crystalline silicon solar cells, silicon wafers have become thinner. In relation to this, the properties of the aluminium-back surface field (Al-BSF) are considered an important factor in solar cell performance. Generally, screen-printing and a rapid thermal process (RTP) are utilized together to form the Al-BSF. This study evaluates Al-BSF formation on a (111) textured back surface compared with a (100) flat back surface with variation of ramp up rates from 18 to $89^{\circ}C$/s for the RTP annealing conditions. To make different back surface morphologies, one side texturing using a silicon nitride film and double side texturing were carried out. After aluminium screen-printing, Al-BSF formed according to the RTP annealing conditions. A metal etching process in hydrochloric acid solution was carried out to assess the quality of Al-BSF. Saturation currents were calculated by using quasi-steady-state photoconductance. The surface morphologies observed by scanning electron microscopy and a non-contacting optical profiler. Also, sheet resistances and bulk carrier concentration were measured by a 4-point probe and hall measurement system. From the results, a faster ramp up during Al-BSF formation yielded better quality than a slower ramp up process due to temperature uniformity of silicon and the aluminium surface. Also, in the Al-BSF formation process, the (111) textured back surface is significantly affected by the ramp up rates compared with the (100) flat back surface.

램프 가열 방식 LPCVD 장비의 설계 및 제작 (Design and Implementation of Lamp-Heated LPCVD System)

  • 하용민;김태성;김충기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 추계학술대회 논문집 학회본부
    • /
    • pp.299-303
    • /
    • 1991
  • A lamp heated LPCVD equipment has been made. Wafer is heated by an array of fifteen tungsten halogen lamps above the front side of a wafer and pyrometer views the back side of the wafer through $CaF_2$ window. Reactor which consisits of a quartz window and a water cooled-stainless steel plate can be evacuated to $5{\times}10^{-3}$ torr with a rotary vane pump. By pyrolysis of $SiH_4$ at about $600^{\circ}C$, polysilicon has been formed on the silicon dioxide film. The measured results show that thickness nonuniformity is 15% and temperature nonuniformity is 1.1%. Because activation energy of pyrolysis of $SiH_4$ is very high, about 1.8eV, small temperature variation will induce large thickness nonuniformity. The main cause of temperature nonuniformity is unsymmetry of lamp power and an unbalanced cooling structure. Charls & Evans' SIMS result shows that the oxygen content in the deposited polysilicon is comparable to that of silicon substrate but carbon content is ten times higher.

  • PDF

제트 팬 설치 위치에 따른 직선터널 내의 제연해석 (Analysis of Smoke Control According to Jet Fan Location in Straight Long Tunnel)

  • 변주석;임효재;강신형;이진호
    • 설비공학논문집
    • /
    • 제19권9호
    • /
    • pp.662-668
    • /
    • 2007
  • In this study, jet fans are installed with 4 cases in the straight long tunnel; inlet-side setup, middle-side setup, outlet-side setup, and dispersion setup. A bus is selected as fired car, of which fire size is 20MW. And fired car locates at 100m, 700m, 1500m position from tunnel inlet, respectively. FLUENT, commercial finite-volume code, is used to analyze the performance. The velocity profile, $CO_2$ concentration, temperature distribution are examined for analysis. Performance of smoke control is compared by the backlayering length. Consequently, inlet-side setup of jet fans is a little more efficient than other cases considering the fire occurrence frequency in tunnel.