• Title/Summary/Keyword: axial wave mode

Search Result 49, Processing Time 0.029 seconds

Helical Instability Wave Excitation of Swirling Jets (스월제트에 관한 헬리컬 불안정파 자극)

  • Lee, Won-Joong;Taghavi, Ray-R.
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.1
    • /
    • pp.48-53
    • /
    • 2005
  • The purpose of this investigation is to explore the possibility of using artificial mechanical means for excitation of shear layers with application in swirling jet mixing enhancement. For this purpose, a mechanical excitation device was designed and fabricated. The major system components consist of two subsonic nozzles, one swirl generator, and the excitation device. The experiments were carried out at various helical excitation modes; i.e., m=+0, m=$\pm$1, m=$\pm$2, m=$\pm$3, and m=$\pm$4. Axial mean velocity measurements were made with plane and helical wave excitation using a hot-wire anemometer. The results are compared with the baseline (plane-wave excitation) at various helical modes. The acquired data is presented in 3-D mesh plots and 2-D contour plots. It was observed that new device was effective in excitation of the helical instability waves and resulting in mixing enhancement of the swirling jet.

A Study of the Vibration Safety Criterion on the Dynamic Behavior of Buried Pipeline with the Free Ends (양단자유 경계조건을 가진 매설관의 동적거동에서 진동안전 기준에 관한 연구)

  • 이병길;정진호;장봉현;안명석
    • Explosives and Blasting
    • /
    • v.22 no.3
    • /
    • pp.13-26
    • /
    • 2004
  • This work reports results of our study on the dynamic response of buried pipelines depending on their boundary conditions. We have studied behavior of the buried pipelines both along the axial and the transverse direction with a boundary condition of free ends. The buried pipelines are modeled as beams on elastic foundation while the seismic wave as a ground displacement in the form of a sinusoidal wave. The natural frequency, its mode, and the effect of parameters have been interpreted in terms of the free vibration. In order to investigate the response on the earthquake, the resulting frequency and the mode shape obtained from the free vibration have been utilized to derive the mathematical formula for the farced vibration. We have also completed the computer program to simulate the time-displacement graphs of the pipe lines with free ends for both cases of vibrations.

Investigation of the BSR Noise characteristics in Seat Cushion-frame with respect to Vibration Durability Test Using Multi-simulator (다축 가진기를 이용한 시트 쿠션 프레임의 내구 전후 BSR 진동특성 연구)

  • Choi, Ho-Il;Nam, Jae-Hyun;Kang, Jae-Young;Park, Jung-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.8
    • /
    • pp.4776-4783
    • /
    • 2014
  • Many studies have examined the reduction of primary noise sources, but quality-related noise, such as BSR, is rarely studied. This study describes the quantitative BSR test method using a multi-axial simulator. The sine sweep test was conducted to detect the system resonance and its relation to BSR noise with high frequency. This method is applied to the seat frame with/without the vibration durability test. The results showed that the $1^{st}$ lateral resonance leads to higher BSR frequency noise. In addition, the reduction of the lateral mode system stiffness after the durability test results in a decrease in the BSR noise in sine sweep test mode.

Buckling Strength of Cylindrical Shell Subjected to Axial Loads (축하중을 받는 원통형 쉘의 좌굴강도)

  • Kim, Seung Eock;Choi, Dong Ho;Lee, Dong Won;Kim, Chang Sung
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.2
    • /
    • pp.191-200
    • /
    • 2001
  • This paper presents buckling analysis of the cylindrical shell subjected to axial loads using numerical method. The modeling method, appropriate element type, and number of element are recommended by comparing with analytical solution. Based on the parametric study, buckling stress decreases significantly as the diameter-thickness ratio increases. These results are different from those obtained from buckling analysis of columns. The number of buckling half-wave in circumferential direction decreases as the diameter-height ratio increases. Buckling stress increases 1~2% as the thickness of base plate increases. Therefore the effect of base plate on buckling strength for cylindrical shell can be disregarded. Buckling stress significantly decreases as the amplitude of initial geometric imperfection used for calculating buckling stress is developed and it shows a good agreement with numerical results.

  • PDF

Measurement of the Skin Blood Flow using Cross-Correlation (Cross-Correlation법에 의한 피부 혈류속도 측정)

  • Lee, Jeong-Taek;Im, Chun-Seong;Ryu, Jeom-Su;Lee, Jong-Su;Gong, Seong-Bae;Kim, Yeong-Gil
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.4
    • /
    • pp.379-384
    • /
    • 1998
  • To measure precisely the blood velocity in the skin microcirculation, we have used time domain correlation (called Cross-Correlation) based on the processing of the backscattered RF signal obtained with a wideband echographic imaging transducer, although it is difficulties of adaptation of the pulsed wave system, because of the data processing in real time and the hardware problem. This dedicated technology based on a 20MHz echographic imaging system has been developed. We present how the experimental data, i.e. the backscattered RF signal, have to be analyzed. After RF lines realignment, stationary echo canceling procedure and correlation level control, a velocity profile has been obtained. In-vitro result show that velocity measurements as low as 0.1mm/sec attainable with a 80${\mu}m$ in axial resolution. We have also validated with in-vivo experimentation on the external ear of a rabbit using B-mode sector scanning image and M-mode image of a custom made 20MHz skin image system. The flow of the "auriculares caudales" vein, a microvessel of 600 m diameter, has been detected and studied. This technique will allow a more precise exploration of circulatory troubles in cutaneous pathologies.

  • PDF

dispersion characteristics and RE power absorption for a mangetized plasma (자화 플라즈마의 분산특성과 유효광학계수 변화)

  • 라상호;정재성;오범환;박세근
    • Journal of the Korean Vacuum Society
    • /
    • v.9 no.3
    • /
    • pp.285-289
    • /
    • 2000
  • It has been well known that weak axial magnetic field on the process plasma enhances plasma density. As the magnetic field helps a specific polarized EM wave mode to penetrate into the plasma, the energy transfer to the plasma enhances and the ion density increases. We have analyzed systematic change of the dispersion relation caused by the cyclotron resonance condition. This resonance occurs at near 5 gauss to provide minimum penetration depth, as known before. RF penetration depth increases abruptly beyond the magnetic field of 5 gauss, and this phenomena lessen as the collision frequency increases.

  • PDF

Magnetron Sputter Coating of Inner Surface of 1-inch Diameter Tube

  • Han, Seung-Hee;An, Se-Hoon;Song, In-Seol;Lee, Keun-Hyuk;Jang, Seong-Woo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.135-135
    • /
    • 2015
  • Tubes are of extreme importance in industries as for fluid channels or wave guides. Furthermore, some weapon systems such as cannons use the tubes as gun barrels. To increase the service life of such tubes, a protective coating must be applied to the tubes' inner surface. However, the coating methods applicable to the inner surface of the tubes are very limited due to the geometrical restriction. A small-diameter cylindrical magnetron sputtering gun can be used to deposit coating layers on the inner surface of the large-bore tubes. However, for small-bore tubes with the inner diameter of one inch (~25 mm), the magnetron sputtering method can hardly be accommodated due to the space limitation for permanent magnet assembly. In this study, a new approach to coat the inner surface of small-bore tubes with the inside diameter of one inch was developed. Instead of using permanent magnets for magnetron operation, an external electro-magnet assembly was adopted around the tube to confine the plasma and to sustain the discharge. The electro-magnet was operated in pulse mode to provide the strong axial magnetic field for the magnetron operation, which was synchronized with the negative high-voltage pulse applied to the water-cooled coaxial sputtering target installed inside the tube. By moving the electro-magnet assembly along the tube's axial direction, the inner surface of the tube could be uniformly coated. The inner-surface coating system in this study used the tube itself as the vacuum chamber. The SS-304 tube's inner diameter was 22 mm and the length was ~1 m. A water-cooled Cu tube (sputtering target) of the outer diameter of 12 mm was installed inside of the SS tube (substrate) at the axial position. The 50 mm-long electro-magnet assembly was fed by a current pulse of 250 A at the frequency and pulse width of 100 Hz and 100 usec, respectively. The calculated axial magnetic field strength at the center was ~0.6 Tesla. The central Cu tube was synchronously driven by a HiPIMS power supply at the same frequency of 100 Hz as the electro-magnet and the applied pulse voltage was -1200 V with a pulse width of 500 usec. At 150 mTorr of Ar pressure, the Cu deposition rate of ~10 nm/min could be obtained. In this talk, a new method to sputter coat the inner surface of small-bore tubes would be presented and discussed, which might have broad industrial and military application areas.

  • PDF

Detection of Thermal Ratcheting Deformation for Cylindrical Shells by Ultrasonic Guided Wave (유도초음파를 이용한 원통형 쉘의 열 라체팅 변형 탐지)

  • Joo, Young-Sang;Lee, Hyeong-Yeon;Kim, Jong-Bum;Park, Chang-Gyu;Lee, Jae-Han
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.5
    • /
    • pp.297-305
    • /
    • 2006
  • The thermal ratcheting deformation at the reactor baffle and upper internal structure of the liquid metal reactor (LMR) can occur due to movement of the hot sodium free surface. In in-service inspection of reactor internals of LMR, a new inspection technique should be developed for the detection of the thermal ratcheting damage. In this study, an inspection technique using ultrasonic guided wave is proposed for the detection of the thermal ratcheting damage of cylindrical vessels. A 316L stainless steel cylindrical shell specimen has been prepared. The thermal ratchet structural tests were cyclically performed by heat-up up to $550^{\circ}C$ with steep temperature gradients along the axial direction after cool-down by cooling water. Ultrasonic guided wave propagation has been characterized by analysis of dispersion curve of the stainless steel plate. The zero-order antisymmetric $A_0$ guided wave has been selected as the optimal mode for detection of the ratcheting deformation. It is confirmed that the thermal ratcheting deformation can be detected by the measurement of transit time difference of circumferentially propagated $A_0$ guided waves.

Dependencies of phase velocities of ultrasonic guided waves on cortical thickness in soft tissue-bone mimicking phantoms (연조직-골 모사 팬텀에서 피질골 두께에 대한 유도초음파 위상속도의 의존성)

  • Lee, Kang Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.6
    • /
    • pp.587-592
    • /
    • 2021
  • Change in the cortical thickness of long bones occurring with aging and osteoporosis is known to be a risk factor for fracture. The present study aims to investigate the dependencies of phase velocities of ultrasonic guided waves on the cortical thickness in 7 soft tissue-bone mimicking phantoms consisting of acrylic plates covered by a 2 mm-thick silicone rubber layer by using the axial transmission technique with a pair of transducers with a center frequency of 200 kHz and a diameter of 12.7 mm. Two distinct propagating waves with different velocities, the First Arriving Signal (FAS) and the Slow Guided Waved (SGW), were consistently observed for all the soft tissue-bone mimicking phantoms. The FAS velocity decreased slightly with increasing thickness, whereas the SGW velocity increased strongly with increasing thickness. The FAS and the SGW velocities were found to be closely consistent with the S0 and the A0 Lamb mode velocities for a free acrylic plate, respectively, suggesting that the presence of the soft tissue mimicking material (2 mm-thick silicone rubber layer) covering the acrylic plates does not influence significantly the velocity measurements.