• Title/Summary/Keyword: average discharge

Search Result 734, Processing Time 0.037 seconds

Properties of PD Pulses Accompanying with Bush-type Tree in LDPE (저밀도 폴리에틸렌에서 부시형 전기트리에 수반되는 부분방전 펄스의 특성)

  • 강성화;박영국;정수현;이광우;임기조
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.12
    • /
    • pp.1055-1059
    • /
    • 1998
  • The correlation between the propagation of electrical tree and distributions of partial discharge(PD) pulses accompanying with electrical tree of bush type in low density polyethylene were discussed. We measured the growth of electrical tree by using optical microscope and PD data simultaneously. The PD data detected and analyzed were PD magnitude, repetition rate, average discharge power, average phase angle, and $\psi$-q-n distribution pattern. The average discharge power and repetition rate of PD had good linear relation with area of tree. Repetition rate and peak discharge magnitude and width of discharge phase angle increased with the tree.

  • PDF

Speech signal processing in the auditory system (청각 계통에서의 음성신호처리)

  • 이재혁;심재성;백승화;박상희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.680-683
    • /
    • 1987
  • The speech signal processing in the auditory system can be analysized based on two representations : Average discharge rate and Temporal discharge pattern. But the average discharge rate representation is restricted by the narrow dynamic range because of the rate saturation and the two tone suppression phenomena, and the temporal discharge pattern representation needs a sophisticate frequency analysis and synchrony measure. In this paper, a simple representation is proposed : using a model considering the interaction of Cochlear fluid-BM movement and a haircell model, the feature of speech signals (formant frequency and pitch of vowels) is easily estimated in the Average Synchronized Rate.

  • PDF

Internal PD Pulses Analysis Accompanying with Bush-type Tree in Solid Dielectrics (고체유전체에서 발생한 부시형 전기트리에 수반된 내부 부분방전 펄스 해석)

  • 강성화;홍현문;류부형
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.1
    • /
    • pp.100-105
    • /
    • 2000
  • Correlation between propagation of bush-type electrical tree and internal partial discharges(PD) was discussed. We used specimens with needle-plane electrode system made of LDPE(Low Density Polyethylene), observed inception and propagation of electrical tree by optical microscope interfaced with computer and investigated characteristics of phase resolved PD pulses accompanying with propagation of electrical tree. Electrical tree generally growed bush-type tree. PD data detected and analyzed were average discharge current and statistical operator of q-n, $\psi$- $q_{avg}$, $\psi$-n, ${\psi}-q_{max}$ distribution. Parameters used were skewness, kurtosis, average discharge phase, cross-correlation factor, asymmetry and etc. In generally, average discharge current had good linear relationship with propagation of bush type electrical tree on this experiment. Peak discharge magnitude and repetition rate were increased, but they had not good linear relationship.p.

  • PDF

Hydraulic Relation of Discharge and Velocity in Small, Steep Mountain Streams Using the Salt-dilution Method (Salt-dilution 방법을 이용한 산지소하천의 유량과 유속 관계 분석)

  • Yang, Hyunje;Lee, Sung-Jae;Im, Sangjun
    • Journal of Korean Society of Forest Science
    • /
    • v.107 no.2
    • /
    • pp.158-165
    • /
    • 2018
  • Reach-average velocity prediction in steep mountain streams is important for understanding fluvial processes and practical applications of erosion control in mountain streams. little studies have been conducted in reach-average velocity, but hydraulic researches have been carried out to examine the relationship between discharge and reach-average velocity in torrent reaches using a relatively large amount of discharge data. In this study, a total of 87 data were measured in 8 torrent reaches. Salt-dilution method was used to estimate discharge. Reach-average velocity was calculated from harmonic mean of travel time that were measured by salt-dilution technique. In order to exlpore the hydraulic relation, both discharge and velocity were non-dimensionalized by using $D_{50}$, $D_{84}$, ${\sigma}_{pro}$ and $IPR_{90}$. It also indicated that ${\sigma}_{pro}$ and $IPR_{90}$ were good variables as roughness height for develop the relationship between non-dimensional discharge and velocity in mountain streams. Generally, reach-average velocity could increase exponentially as discharge increases.

Partial discharge properties of insulating materials for UPS (UPS용 절연재료의 부분방전 특성)

  • 이덕진
    • Journal of the Korea Computer Industry Society
    • /
    • v.4 no.12
    • /
    • pp.1013-1020
    • /
    • 2003
  • In this paper, the discharge properties due to time variation were investigated in order to estimate a electrical performance of the insulator for small transformer. AC 10[kVl applied to specimen was converted to $\pm$5[V] and stored to personal computer through A/D converter. A period of applied wave form and discharge values were divided into 64 parts and discharge values generated during 10 seconds were accumulated by phases. As a result, it was confirmed that count of discharge, total discharge and the variation degree of average discharge were decreased as time elapsed.

  • PDF

Partial Discharge Characteristics of the XLPE/EPDM Interface in Power Cable Joint (전력케이블 접속재 XLPE/EPDM 계면의 부분방전 특성)

  • Cho, Kyung-Soon;Hong, Jin-Woong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.9
    • /
    • pp.780-786
    • /
    • 2007
  • This paper describes the influence on partial discharge characteristics of defects at the model XLPE/EPDM interfaces of power cable joints. The defects of void and copper which could inadvertently be present at the joint interface. We measured ${\Phi}-n,\;{\Phi}-q$ patterns by a computer-aided partial discharge measuring system. Several parameters i, e, maximum discharge $q_{max}$ [pC], average discharge q [pC/cycle], and average angle of discharge ${\Theta}g$ [deg] were found to depend upon the defect type varying applied voltage. As the result of time evaluation, partial discharges are small different at copper defects, but is decreasing obviously about 20 minutes at void defect. It considered that difference of magnitude of total positive discharge of Q+ [pC] and total negative discharge of Q- [pC] is SPMD(swarming pulsive micro discharges).

A Study on the Calculation of Storage Volume of Storm-Water Detention Basins for Small Urban Catchments (도심지 소유역에 적용 가능한 우수저류조의 용량 산정에 관한 연구)

  • Kim, Dae Geun;Koh, Young Chan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.5
    • /
    • pp.619-624
    • /
    • 2005
  • This work is for examining a simplified equation based on the rational formula, which can easily decide storm-water detention volume in small urban catchments. The storm-water detention volume is determined by the inflow hydrograph flowing to detention basin and the outflow hydrograph discharged from the detention basin. The ratio of average outflow over the period of rainfall duration against allowable discharge was 0.5 in former simplified equation. But this research has found that the average outflow ratio depends on the storage methodology. In the case of the on-line storage method, the average outflow ratio is a function of the time of concentration of the catchments and rainfall duration, which ranged from 0.5~1.0. In the case of the off-line storage method, the average ratio is a function of peak discharge and allowable discharge except above time of concentration and rainfall duration, where its function value ranged from 1.0~2.0. When applying this equation to small catchment in Mokpo city, South Korea, we could easily calculate the relation curve between the storm-water detention volume and allowable discharge.

Preventive diagnosis of the power transformer by the moving average of ultrasonic signal number (超音波 信號 數의 移動平均에 의한 電力用 變壓器 豫防診)

  • 권동진;곽희로;정상진;김정부
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.3
    • /
    • pp.432-437
    • /
    • 1996
  • This paper describes a diagnostic technique of power transformers by on-line detection of ultrasonic signals. A trend of partial discharge variation in a real transformer was estimated by counting the number of ultrasonic signals until insulation paper in the point-to-plane electrode is punctured. The number of electrical signals is closely related to the ultrasonic signals generated by partial discharge. The trend of the ultrasonic signal number could easily be distinguished by taking moving average. The insulation failure due to partial discharge in transformers can be predicted based on the trend analysis of ultrasonic signal number caused by partial discharge. (author). 14 refs., 10 figs.

  • PDF

A Study on the Mean Flow Velocity Distribution of Jeju Gangjung-Stream using ADCP (ADCP를 활용한 제주 강정천의 평균유속 분포 추정)

  • Yang, Se-Chang;Kim, Yong-Seok;Yang, Sung-Kee;Kang, Myung-Soo;Kang, Bo-Seong
    • Journal of Environmental Science International
    • /
    • v.26 no.9
    • /
    • pp.999-1011
    • /
    • 2017
  • In this study, the Chiu-2D velocity-flow rate distribution based on theoretical background of the entropy probability method was applied to actual ADCP measurement data of Gangjung Stream in Jeju from July 2011 to June 2015 to predict the parameter that take part in velocity distribution of the stream. In addition, surface velocity measured by SIV (Surface Image Velocimeter) was applied to the predicted parameter to calculate discharge. Calculated discharge was compared with observed discharge of ADCP observed during the same time to analyze propriety and applicability of depth of water velocity average conversion factor. To check applicability of the predicted stream parameter, surface velocity and discharge were calculated using SIV and compared with velocity and flow based on ADCP. Discharge calculated by applying velocity factor of SIV to the Chiu-2D velocity-flow rate distribution and discharge based on depth of water velocity average conversion factor of 0.85 were $0.7171m^3/sec$ and $0.5758m^3/sec$, respectively. Their error rates compared to average ADCP discharge of $0.6664m^3/sec$ were respectively 7.63% and 13.64%. Discharge based on the Chiu-2D velocity-flow distribution showed lower error rate compared to discharge based on depth of water velocity average conversion factor of 0.85.

Detection of the Ultrasonic Signals due to Partial Discharges in a 154kV Transformer

  • Kweon, Dong-Jin;Chin, Sang-Bum;Kwak, Hee-Ro
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.2C no.6
    • /
    • pp.297-303
    • /
    • 2002
  • We have developed an on-line ultrasonic detector to monitor partial discharge in an operating transformer. The ultrasonic sensor has 150[KHz] resonance frequency and contains a pre-amplifier with 60[㏈] gain. The on-line ultrasonic detector has 50~300[KHz] frequency band-pass filter to remove electrical and mechanical noises from the transformer. This detector has an ultrasonic signal discrimination algorithm which discriminates ultrasonic signals due to partial discharge in a transformer. A moving average method of ultrasonic signal number was employed to effectively monitor the increasing trend of the partial discharge. This paper describes an experience of partial discharge detection in a 154[㎸] operating transformer using an ultrasonic detector. With regards to gas analysis in oil, C2H2 gas was produced with a warning level in this transformer We detected ultrasonic signals on the transformer steel wall, and estimated the position of partial discharge. With further inspection, we found carbonized marks due to partial discharge on the supporting bolt which fastens the windings.