• Title/Summary/Keyword: average curvature

Search Result 139, Processing Time 0.02 seconds

New approach for Ductility analysis of partially prestressed concrete girders

  • Radnic, Jure;Markic, Radoslav;Grgic, Nikola;Cubela, Dragan
    • Structural Engineering and Mechanics
    • /
    • v.70 no.3
    • /
    • pp.257-267
    • /
    • 2019
  • Expressions for the calculation of ductility index for concrete girders with different ratios of prestressed and classical reinforcement were proposed using load-displacement, load-strain and load-curvature relation. The results of previous experimental static tests of several large-scale concrete girders with different ratio of prestressed and classical reinforcement are briefly presented. Using the proposed expressions, various ductility index of tested girders were calculated and discussed. It was concluded that the ductility of girders decreases approximately linearly by increasing the degree of prestressing. The study presents an expression for the calculation of the average ductility index of classical and prestressed reinforced concrete girders, which are similar to the analysed experimental test girders.

Yield Load Interpretation for Drilled Shaft Foundations by Hyperbolic Approximation (쌍곡선 근사에 의한 현장타설말뚝의 항복하중 판정)

  • Won, Sang-Yeon;Hwang, Seong-Il;Jo, Nam-Jun
    • Geotechnical Engineering
    • /
    • v.12 no.6
    • /
    • pp.79-86
    • /
    • 1996
  • This study develops a new method for interpreting the yield load from load tests on drilled shaft foundations ended on general soils, which is defined as a point where the maximum curvature on the hyperbolic-approximated load-settlement curve occurs. How ever, the point of maximum curvature is a variable depending on the units and scales of the load and settlement. Therefore, to obtain a unique maximum curvature point, both the load and settlement must be normalized by proper parameters, respectively, and be expressed on the same scaled arses(1:1). Normalization has been processed so that the yield load by the new interpretation is to be close to the average of yield loads interpreted by other methods investigated in this study. The quantitative comparison between the new criterion and other conventitonal methods is presented.

  • PDF

Cyclic fatigue, bending resistance, and surface roughness of ProTaper Gold and EdgeEvolve files in canals with single- and double-curvature

  • Khalil, Wafaa A.;Natto, Zuhair S.
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.2
    • /
    • pp.19.1-19.9
    • /
    • 2019
  • Objectives: The purpose of this study was to evaluate the cyclic fatigue, bending resistance, and surface roughness of EdgeEvolve (EdgeEndo) and ProTaper Gold (Dentsply Tulsa Dental Specialties) nickel-titanium (NiTi) rotary files. Materials and Methods: The instruments (n = 15/each) were tested for cyclic fatigue in single- ($60^{\circ}$ curvature, 5-mm radius) and double-curved (coronal curvature $60^{\circ}$, 5-mm radius, and apical curvature of $30^{\circ}$ and 2-mm radius) artificial canals. The number of cycles to fracture was calculated. The bending resistance of both files were tested using a universal testing machine where the files were bent until reach $45^{\circ}$. Scanning electron microscopy and x-ray energy-dispersive spectrometric analysis were used for imaging the fractured segments, while the atomic force microscope was used to quantify the surface roughness average (Ra). Results: EdgeEvolve files exhibited higher cyclic fatigue resistance than ProTaper Gold files in single- and double-curved canals (p < 0.05) and both files were more resistant to cyclic fatigue in single-curved canals than double-curved canals (p < 0.05). EdgeEvolve files exhibited significantly more flexibility than did ProTaper Gold files (p < 0.05). Both files had approximately similar Ni and Ti contents (p > 0.05). EdgeEvolve files showed significantly lower Ra values than ProTaper Gold files (p < 0.05). Conclusions: Within the limitation of this study, EdgeEvolve files exhibited significantly higher cyclic fatigue resistance than ProTaper Gold files in both single- and double-curved canals.

Influence of Tension Stiffening Effect on Deflection and Crack Width in RC Members (철근콘크리트 부재의 처짐과 균열폭에 대한 인장증강효과의 영향)

  • Choi, Seung-Won;Yang, Jun-Ho;Kim, Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.6
    • /
    • pp.761-768
    • /
    • 2010
  • When cracks occur in reinforced concrete structures, a steel carries all tensile force at crack section, while the concrete between cracks carries a part of the tensile force due to bond, so that the steel is less elongated. This is called the tension-stiffening effect, that plays an important role in verification of a serviceability limit state. But it is a complicated work to use a complex strain distribution between cracks, therefore an average strain is used to calculate deflection and crack width. In Eurocode 2, tension-stiffening effect expressed in the first order form or the second order form is used in calculating an average curvature for deflection. In this study for a flexural member deflection and crack width are calculated using various models for the tension-stiffening effect and the results are compared with the values of Eurocode 2 and KCI provisions. As results, the predicted values using the second order form are appeared to be well agreed with the experimental values and it could secure more analytical consistency.

Analysis of Crack Width and Deflection Based on Nonlinear Bond Characteristics in Reinforced Concrete Flexural Members (비선형 부착 특성에 기반한 철근콘크리트 휨부재의 균열폭과 처짐 해석)

  • Lee, Gi-Yeol;Kim, Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.4
    • /
    • pp.459-467
    • /
    • 2008
  • This paper describes a proposal for average crack width and immediate deflection calculation in structural concrete members. The model is mathematically derived from actual bond stressslip relationships and tension stiffening effect between reinforcement and the surrounding concrete, and the actual strains of steel and concrete are integrated respectively along the embedded length between the adjacent cracks so as to obtain the difference in the axial elongation. With these, a model for average crack width and immediate deflection in reinforced concrete flexural members are proposed utilizing difference in the axial elongation and average steel strain and moment-curvature relationship with taking account of bond characteristics. The model is applied to the test specimens available in literatures, and the crack width and deflections predicted by the proposal equation in this study are closed to the experimentally measured data compared the current code provisions.

Usefulness of Customized Cervical Spine Immobilizer in Head & Neck Image-Guided Radiation Therapy with Tomotherapy® (토모테라피를 이용한 두경부암 영상유도 방사선 치료 시 개인별 경추고정용구의 유용성 평가)

  • Jin, Sung Eun;Chang, Se Wuk;Choi, Jung Hoan;Kim, Min Joo;Ahn, Seung Kwon;Lee, Sang Kyu;Cho, Jung Heui
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.65-71
    • /
    • 2018
  • Purpose : Standardized pillow may not support patient's individual cervical spine thoroughly when head and neck radiation therapy with $Tomotherapy^{(R)}$. Therefore, the purpose of this study was to make a comparative analysis for the difference of using standardized pillow only and using customized cervical spine immobilizer with standardized pillow. Materials and Methos : The head and neck cancer patients who are treated image-guided radiation therapy(IGRT) with $Tomotherapy^{(R)}$ were divided into two groups, 20 patients using standardized pillow only, and 20 patients using customized cervical spine immobilizer with standardized pillow. We achieved 20 mega-voltage computed tomography(MVCT) image per patient, compared curvature of the cervical spine in MVCT with curvature of the cervical spine in CT-simulation. Results : Results of comparative analysis were curvature consistency 95.9 %, maximum error of distance 41.9 mm, average distance error per fractionation 19.4 mm, average standard deviation 1.34 mm in case of using standardized pillow only, curvature consistency 98.9 %, maximum error of distance 12.9 mm, average distance error per fractionation 5.8 mm, average standard deviation 0.59 mm in case of using customized cervical spine immobilizer with standardized pillow. Conclusion : Using customized cervical spine immobilizer shows higher reproducibility and low distance error, therefore customized cervical spine immobilizer could be useful for head and neck cancer patients who need radiation therapy.

  • PDF

THE EFFECT OF NiTi ROTARY INSTRUMENTATION ON THE CHANGE OF APICAL ROOT CANAL CURVATURE (NiTi Rotary Instrumentation이 근관만곡도 변화에 미치는 영향)

  • Lim, Hyoung-Tae;Hong, Chan-Ui;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.257-268
    • /
    • 1998
  • During cleaning and shaping of narrow and curved canals, it is very difficult or nearly impossible to maintain the original canal shape. Procedural accidents such as, ledge, zipping, perforation, and instrument breakage are frequently occurred and even may lead to failure of endodontic therapy. To prevent these kinds of accidents, various instrumentation techniques and materials have been introduced. Recently some nickel titanium (NiTi) files are introduced and it is reported that These NiTi files created rounder preparations with less transportation than conventional instruments in curved canals. This study compared the change of the canal curvature and procedural accidents after instrumentation produced by stainless steel K-flexo file, and NiTi rotary files (Profile 29 and Quantec 2000). Thirty narrow and curved canals (25-45 degree) of extracted human molars were randomly divided into three groups. In group 1, canals were instrumented using a step-back and watch-winding/pull motion with K-flexo files. In group 2, canals were prepared with Profile 29. Group 3, canals were prepared with Quantec 2000 files. Before and after preparation of canals, periapical radiographs were taken and scanned. The change of canal curvature were measured using Photoshop 4.0 program and the incidence of procedural accidents were also evaluated. The results were as follows: 1. All group showed some loss of canal curvature after instrumentation. 2. Average loss of canal curvature was $6.70{\pm}5.31$ degree for group 1, $3.80{\pm}2.57$ degree for group 2, and $5.40{\pm}4.83$ degree for group 3. All group There was significant change in curvature between before and after instrumentation (p<0.05). But there was no statistical difference amoung 3 groups. 3. In group I, there were no procedural accidents, such as ledging, perforation, or instrument fracture. In group 2, two cases of ledge and one case of instrument fracture were produced Goup 3, each one case of ledge, perforation and instrument fracture were occurred. Whthin the limits of above results, It seems that NiTi rotary instrumentation is not All Mighty and if we use uncarefully, it is more dangerous to produce some procedural accidents than conventional hand files. But more studies should be taken to evaluate the exact effects of NiTi rotary instrumentations.

  • PDF

Effective Moment of Inertia of Flexural Members Based on the Concrete Stress-Strain Curve in EC-2 (EC-2의 콘크리트 응력-변형률 곡선에 기반한 휨부재의 유효단면2차모멘트)

  • Yum, Hwan-Seok;Kim, Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.6
    • /
    • pp.655-663
    • /
    • 2016
  • The present study shows the moment-average curvature relationship and effective inertia moment of RC beams obtained from the nonlinear analysis based on the parabola-rectangular stress-strain curve defined in EC-2 code. The variables examined are concrete strength and steel ratio, and moment-average curvature relationship and effective inertia moment obtained are compared with those of the current KCI provisions. As the results of the comparison, the followings could be said: Since the KCI provisions(the Branson method) were originally derived based on the experimental data ranged from 2.2 to 4 of $M/M_{cr}$ and 1.3 to 3.5 of $I_{ut}/I_{cr}$, thereby within these ranges the inertia moments obtained from the nonlinear analysis are closely agreed with those predicted by the Branson method. However, beyond those range the remarkable difference could be found between the two results. In particular, for beams having low steel ratio the inertia moment resulted from the nonlinear analysis are significantly smaller than those obtained from the KCI(Branson) method. This result may imply that the deflection of lightly reinforced members, such as slabs in buildings, becomes much larger than those calculated according to the current design provisions.

COMPACT MANIFOLDS WITH THE MINIMAL ENTROPY

  • Yim, Jin-Whan
    • Communications of the Korean Mathematical Society
    • /
    • v.10 no.2
    • /
    • pp.365-374
    • /
    • 1995
  • On a compact manifold without conjugate points, the volume entropy can be obtained as the average mean curvature of the horospheres in the universal covering space. In the case when the volume entropy is zero, we prove that the universal covering space is diffeomorphic to a product space with a line factor. This fact can be considered as a surporting evidence for the Mane's conjecture, which claims the flatness of the mainfold.

  • PDF

A Ride Quality Measurement of Rolling Stock used in Airport Railway (공항철도 전동차의 승차감 측정)

  • Jeon, Chang-Sung;Ryu, Joon-Hyoung;Baik, Kwang-Sun;Yoon, Sung-Cheol;Kim, Myung-Ryong;Kim, Weon-Kyung
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1546-1549
    • /
    • 2007
  • A ride quality measurement was carried out for commuter and express train used in airport railway. Lateral and vertical directional average ride quality level is higher than that of longitudinal direction. Because express train is faster than commuter train, the average ride quality level of express train is higher compared to that of commuter train. The average ride quality level of commuter train is between 'good comfortable($100{\sim}105dB$)' and 'very good comfortable(below 100dB)'. The average ride quality level of express train is between 'not comfortable($105{\sim}110dB$)' and 'good comfortable($100{\sim}105dB$)'. In spite of the scheduled speed is higher(more than 70km/h for commuter train, more than 80km/h for express train) than other lines, the ride quality of airport railway train is good. The reason is that there is little gradient in rail and the radius of curvature is larger compared to that of other lines.

  • PDF