• Title/Summary/Keyword: average curvature

Search Result 140, Processing Time 0.023 seconds

An Investigation of Heat Transfer Characteristics of Swirling Flow in a 180$^{\circ}$ Circular Section Bend with Uniform Heat Flux

  • Chang, Tae-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.10
    • /
    • pp.1520-1532
    • /
    • 2003
  • An experiment was performed to obtain the local heat transfer coefficient and Nusselt number in a circular duct with a 180$^{\circ}$ bend for Re=6 x 10$^4$, 8 x 10$^4$ and 1 x 10$\^$5/ under swirling flow and non-swirling flow conditions. The test tube with a circular section was made from stainless steel having a curvature ration of 9.4. Current heat flux of 5.11 kW/㎡ was applied to the test tube by electrical power and the swirling motion of air was produced by a tangential inlet to the pipe axis at 180$^{\circ}$. Measurements of local wall temperatures and the bulk mean temperatures of air were made at four circumferential positions at 16 stations. The wall temperatures showed a reduced distribution curve at the bend for the non-swirling flow, but this effect did not appear for the swirling flow. The Nusselt number distributions for the swirling flow, which was calculated from the measured wall and the bulk temperatures, were higher than that of the non-swirling flow. The average Nusselt number of the swirling flow increased by about 90-100%, compared to that of the non-swirling flow. The Nu/Nu$\_$DB/ values at the 90$^{\circ}$ station for non-swirling flow and swirling flow were approximately 2.5 and 4.8 at Re=6x10$^4$ respectively. The values agree well with Said's results for non-swirling flow.

Pectus excavatum and operative treatment: 14 cases report (누두흉의 수술적 교정: 14례 보고)

  • Sun, Kyung;Chae, Seong-Soo;Lee, Chul-Sae;Baek, Kwang-Jei;Kim, Hark-Jei;Kim, Hyong-Mook
    • Journal of Chest Surgery
    • /
    • v.16 no.1
    • /
    • pp.183-190
    • /
    • 1983
  • Pectus Excavatum is a congenital anomaly of the anterior chest wall with a sharp concave curvature of the body of the sternum, from above downward and from side to side, especially just before the junction of gladiolo-xiphoid. We have experienced 14 cases of Pectus Excavatum with several operative procedures, i.e., Ravitch operation in 1 case, Wada operation [Sternal turn-over} in 3 cases, Wada operation and K-wire splint in 5 cases, Modified Wada operation [Rectus Abdominis muscle pedicle attached sternal turn-over] in 5 cases. Nearly all patients developed flail chest treated with internal fixation, and necrotic chondritis was developed postoperatively and treated with excision and curettage in one case with Wada operation. Follow-up Vertebral Index showed 48% preoperatively and 33% postoperatively, average decrement of 15%. We report 14 cases of Pectus Excavatum and their operative treatments.

  • PDF

A Study on the Wide Reach Nozzle of Sprayer (V) -The Long Range Nozzle- (휴반용 분무기의 Nozzle에 관한 연구(V) -원거리용 Nozzle-)

  • 옹장우;이상우
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.17 no.4
    • /
    • pp.3991-4000
    • /
    • 1975
  • It is the aim of this study to investigate the influence of the factors in the sprayer nozzle for the travelling distance and to get nozzle design data in relation to the nozz1e with and without swirl plate. The factors of sprayer nozzle are composed of the spraying pressure, the helical angle of swirl plate, the helical groove depth of swirl plate, the distance of vortex chamber the slope of nozz1e cap, the curvature of nozzle cap and the hole diameter of nozz1e cap. The travelling distance and the size of sprayed particle are experimeted indoors by the factorial arrange-ment according to the 5 each level of the above factors. The results of this stupy are summarized as follows; 1. In the nozzle with swirl p1ate there were remarkable significance among factors each other, while without swirl plate were no significance. 2. The helical angle and groove depth in the nozzle with swirl plate were the highest effective factors. The effect of helical angle was very remarked in the quadratic curve with minium value. 3. The correlation betweenthe travelling distance and the sprayed particle size was no high and under 250 micron in the case with swirl plate, and there was higher correlation in the case without swirl plate. 4. The new ideal development of the swirl plate using of the most effective helical angle and groove depth will probably show the possiblities to make effective travelling distance over 8 meters and more over and to make average particle diameter under 300 micron.

  • PDF

Velocity Field Measurement of Flow Around a Surface-Mounted Vertical Fence Using the Two-Frame PTV System (2-프레임 PTV를 이용한 수직벽 주위 유동장 해석)

  • Baek, Seung-Jo;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.10
    • /
    • pp.1340-1346
    • /
    • 1999
  • The turbulent shear flow around a surface-mounted vertical fence was investigated using the two-frame PTV system. The Reynolds number based on the fence height(H) was 2950. From this study, it is revealed that at least 400 instantaneous velocity field data are required for ensemble average to get reliable turbulence statistics, but only 100 field data are sufficient for the time-averaged mean velocity information. Various turbulence statistics such as turbulent intensities, turbulence kinetic energy and Reynolds shear stress were calculated from 700 instantaneous velocity vector fields. The fence flow has an unsteady recirculation region behind the fence, followed by a slow relaxation to the flat-plate boundary layer flow. The time-averaged reattachment length estimated from the streamline distribution is about 11.2H. There exists a region of negative Reynolds shear stress near the fence top due to the highly convex (stabilizing) streamline-curvature of the upstream flow. The large eddy structure in the separated shear layer seems to have significant influence on the development of the separated shear layer and the reattachment process.

Heat transfer coefficient measurement by a jet impinging on a rib-roughened convex surface (표면조도를 가지는 볼록한 면에 충돌하는 제트에 의한 열전달계수 측정)

  • Jeong, Yeong-Seok;Lee, Dae-Hui;Lee, Jun-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.3
    • /
    • pp.373-385
    • /
    • 1998
  • The local Nusselt numbers have been measured for a round turbulent jet impinging on the convex surface with and without rib. Liquid crystal/transient method was used to determine the Nusselt number distributions along the surface. The temperature on the surface was measured to within .+-.0.25 deg. C accuracy using liquid crystal and a digital color image processing system. The experiments were made for the jet Reynolds number (Re) 23,000, the dimensionless nozzle-to-surface distance (L/d) from 6 to 10, the dimensionless surface curvature (d/D) 0.056, and the various rib types (height(d$_{1}$) from 1 to 2 mm, pitch (p) from 6 to 32 mm). It was found that the average Nusselt numbers on the convex surface with rib are higher than those without rib, mainly due to an increase in the turbulent intensity caused by flow separation, recirculation and reattachment on the wall surface. In addition, we compared the results by the steady-state method using the gold-film Intrex with those by the transient method.

Application of a Composite Skin Equivalent using Collagen and Acellular Dermal Matrix as the Scaffold in a Mouse Model of Full-thickness Wound (콜라겐과 무세포진피를 이용한 혼합형 인공피부 개발 및 쥐 모델에서 창상치료 적용)

  • Lee, Dong Hyuck;Youn, Jin Chul;Lee, Jung Hee;Kim, In Seop
    • KSBB Journal
    • /
    • v.29 no.1
    • /
    • pp.42-49
    • /
    • 2014
  • The aim of this study was to develop a composite human skin equivalent for wound healing. Collagen type1 and acellular dermal matrix powder were utilized as the scaffold with dermal fibroblasts and keratinocytes for the development of a composite human skin equivalent. Fibroblast maintained the volume of composite skin equivalent and also induced keratinocytes to attach and proliferate on the surface of composite skin equivalent. The composite human skin equivalent had a structure and curvature similar to those of real skin. Balb-C nu/nu mice were used for the evaluation of full-thickness wound healing effect of the composite human skin equivalent. Graft of composite skin equivalent on full-thickness wound promoted re-epithelialization and granulation tissue formation at 9 days. Given the average wound-healing time (14 days), the wound in the developed composite skin equivalent healed quickly. The overall results indicated that this three-dimensional composite human skin equivalent can be used to effectively enhance wound healing.

Automate Capsule Inspection System using Computer Vision (컴퓨터 시각장치를 이용한 자동 캡슐 검사장치)

  • 강현철;이병래;김용규
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.32B no.11
    • /
    • pp.1445-1454
    • /
    • 1995
  • In this study, we have developed a prototype of the automatic defects detection system for capsule inspection using the computer vision techniques. The subjects for inspection are empty hard capsules of various sizes which are made of gelatine. To inspect both sides of a capsule, 2-stage recognition is performed. Features we have used are various lengths of a capsule, area, linearity, symmetricity, head curvature and so on. Decision making is performed based on average value which is computed from 20 good capsules in training and permission bounds in factories. Most of time-consuming process for feature extraction is computed by hardware to meet the inspection speed of more than 20 capsules/sec. The main logic for control and arithmetic computation is implemented using EPLD for the sake of easy change of design and reduction in time for developement. As a result of experiment, defects on size or contour of binary images are detected over 95%. Because of dead zone in imaging system, detection ratio of defects on surface, such as bad joint, chip, speck, etc, is lower than the former case. In this case, detection ratio is 50-85%. Defects such as collet pinch and mashed cap/body seldom appear in binary image, and detection ratio is very low. So we have to process the gray-level image directly in partial region.

  • PDF

$TiO_2$ Nanocubes for Rapid Electron Transfer in Dye-Sensitized Solar Cell

  • Yang, Hye-Yeong;Bang, So-Yeon;Lee, Do-Gwon;Go, Min-Jae;Kim, Gyeong-Gon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.317-317
    • /
    • 2010
  • This paper reports syntheses of $TiO_2$ nanocubes and theirs application to DSSC. We synthesized $TiO_2$ nanocubes via solvothermal method using titanium isopropoxide (TTIP) and tetramethylammoiumhydroxide (TMAH). By adding longer alkyl chain ammonium hydroxide that slowed down the growth rate of the crystal, $TiO_2$ nanocubes were obtained with average particle size in the range of 40 nm to 70 nm. By TEM investigation, each particle was found to be single crystal of anatase having six-faces of (001) and {100} crystallographic planes truncated by {101} series of planes, which are clearly distinguishable from spherical nanoparticles. Among various application, utilizing nanocubes as photo-electrode in dye-sensitized solar cell, we investigated photo-electron conversion performances in comparison with spherical shaped $TiO_2$ nanoparticles by I-V characteristics and IPCE measurements, etc.. Photocurrent-transient analysis revealed that $TiO_2$ nanocubes have a higher transient electron transfer rate by more than 10 times compared with spherical particles of similar size. Fast electron transport along the cube edges having small curvature was suggested as a plausible origin of high diffusion coefficient of electron in nanocube $TiO_2$.

  • PDF

Extraction of Vein Patterns using Hierachical Slicing Algorithm (계층적 슬라이싱 알고리즘을 사용한 정맥 패턴 검출)

  • Choi, Won-Seok;Jang, Kyung-Sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.861-864
    • /
    • 2009
  • Recently, the biometric recognition technology of veins in different parts of hand is very active. In this paper the image hierarchical slicing provides a way to detect vein patterns. The scanned vein image will be sliced into various thicknesses. We first get the average brightness values of the sliced image and then convert them into curvature where we can detect candidates of the vein. The candidates of the vein are used to do a further analysis. We search all of the vein candidates and analyze them to get the real vein pattern in the overlapping extraction. We propose this novel algorithm to detect the vein pattern from the original image.

  • PDF

Fragility assessment of shear walls coupled with buckling restrained braces subjected to near-field earthquakes

  • Beiraghi, Hamid
    • Steel and Composite Structures
    • /
    • v.33 no.3
    • /
    • pp.389-402
    • /
    • 2019
  • Reinforced concrete walls and buckling restrained braces are effective structural elements that are used to resist seismic loads. In this paper, the behavior of the reinforced concrete walls coupled with buckling restrained braces is investigated. In such a system, there is not any conventional reinforced concrete coupling beam. The coupling action is provided only by buckling restrained braces that dissipate energy and also cause coupling forces in the wall piers. The studied structures are 10-, 20- and 30-story ones designed according to the ASCE, ACI-318 and AISC codes. Wall nonlinear model is then prepared using the fiber elements in PERFORM-3D software. The responses of the systems subjected to the forward directivity near-fault (NF) and ordinary far-fault (FF) ground motions at maximum considered earthquake (MCE) level are studied. The seismic responses of the structures corresponding to the inter-story drift demand, curvature ductility of wall piers, and coupling ratio of the walls are compared. On average, the results show that the inter-story drift ratio for the examined systems subjected to the far-fault events at MCE level is less than allowable value of 3%. Besides, incremental dynamic analysis is used to examine the considered systems. Results of studied systems show that, the taller the structures, the higher the probability of their collapse. Also, for a certain peak ground acceleration of 1 g, the probability of collapse under NF records is more than twice this probability under FF records.