• Title/Summary/Keyword: average curvature

Search Result 139, Processing Time 0.037 seconds

Radiologic Analysis of Cervical Lordosis for University Students (대학생들의 경추의 전만 각도에 대한 고찰)

  • Cho, Dong-In;Yoon, Jeong-won;Kim, Soon-Joong;Park, Dong-Su
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.25 no.4
    • /
    • pp.83-92
    • /
    • 2015
  • Objectives To measure and analyze the curvature of the cervical spine for university students. Methods This study carried out on 132 students. The cervical spine curvature was measured by six measuring methods. The type and numeric value of cervical spine curvature was analyzed by Angle of cervical curve (C1~C7), Angle of cervical curve (C2~C7), Jackson's angle, Ishihara Index, Depth of cervical curve and Method of Jochumsen. Cervical spine curvatures between male and female are compared by Mann-Whitney test. Rate of type of cervical curvature between male and female are compared by linear by linear association. Results 1. The average of angle of cervical curve (C1~C7) is $33.78{\pm}9.85^{\circ}$, angle of cervical curve (C2~C7) is $10.28{\pm}8.12^{\circ}$. The average of Jackson's angle is $14.02{\pm}10.01^{\circ}$, average of Ishihara Index is $8.46{\pm}10.58%$. The average of Depth of cervical curve is $5.15{\pm}4.72mm$ and average of Method of Jochumsen is $0.94{\pm}3.83mm$. 2. More than half of student's cervical curvature showed hypolordosis except Ishihara index. 3. There was significant difference in numeric value of cervical curvature between male and female both groups in terms of Ishihara index. 4. There were insignificant differences between male and female in terms of type of cervical curvature. Conclusions According to above results, we found out average of student's cervical curve. And the results suggest that most of the student's cervical curvature decrease.

Visual Perception of Garment Surface Appearance

  • Fan, Jintu;Liu, Fu
    • Science of Emotion and Sensibility
    • /
    • v.5 no.3
    • /
    • pp.1-10
    • /
    • 2002
  • This paper concerns with the relationship between the visual perception of the degree of pucker or wrinkles of garment surfaces and the geometrical parameters of surfaces. In this study, four potentially relevant parameters of the surface profile are considered, namely, the variance ($\sigma$$^2$), the cutting frequency (F$\_$c/), the effective disparity curvature (D$\_$ce/) (Defined as the average disparity curvature of the wrinkled surface over the eyeball distance of the observer) and the frequency component of the disparity curvature ( D$\_$cf/). Based on the experiments using garment seams having varying degree of pucker (i.e. the wrinkles along a seam line), it was found that, while the logarithm of each of these four parameters has a strong linear relationship with the visually perceived degree of wrinkles, following the Web-Fetchner Law, the effective disparity curvature ( D$\_$ce/) and the frequency component of the disparity curvature (D$\_$cf/) appeared to have stronger relationships with the visual perception. This finding is in agreement with the suggestion by Rogers '||'&'||' Cagenello that human visual system may compute the disparity curvature in discriminating curved surfaces. It also suggested an objective method of measuring the degree of surface wrinkles.

  • PDF

Analysis Of The Average Rate Of Change And Curvature According To The Type Of Angled And Arched Eyebrow Makeup (각진형과 아치형 눈썹메이크업의 평균변화율 및 곡률에 따른 형태구성의 중요요인 분석)

  • Park, Jeong Shin;Park, Dong Eun
    • Journal of Fashion Business
    • /
    • v.23 no.1
    • /
    • pp.116-126
    • /
    • 2019
  • The purpose of this study is to objectify the shape of curvature and average change rate of angular and arched eyebrow makeup. The data for the analysis were the final 336 pieces for the cosmetology students in the whole country. SPSS 20.0 program was used for the collected data, frequency analysis, factor analysis, reliability analysis, and crossover analysis were performed. First, the frequency of the average change rate of eyebrow makeup (angular and arcuate) was analyzed. As a result, the eyebrows suitable for the angled type showed the highest level of 'A-2' and the arched eyebrows had the highest level of 'B-2'. Second, to analyze the important factors of eyebrow makeup, frequency of eyebrows was the most important, followed by the inclination of eyebrows and eyebrow tail. Third, factor analysis and reliability analysis were conducted to examine each dimension of eyebrow makeup perception, and it was derived from three factors including acceptability, aggressiveness, and playability. Fourth, in order to analyze the difference of important factors in the form of the standard eyebrow makeup, the cross - analysis was performed with chi - square test, and it was confirmed that the angular eyebrow makeup showed the most objectivity when the average change rate was 0.29 and the curvature was 0.67. Fifth, arcuate eyebrow makeup showed the most objectivity when the average change rate was 0.57 and curvature was 0.56. The results of this analysis can be used as objective data of aesthetic criteria when designing the eyebrow shape.

Position of the Fist Cervical Vertebra in Relation to Cervical Curvature (제 1경추골의 위치와 경추만곡도 간의 관계)

  • Moon-Il Her;Kyung-soo Han
    • Journal of Oral Medicine and Pain
    • /
    • v.21 no.1
    • /
    • pp.197-206
    • /
    • 1996
  • This study ws performed to investigate the relationship between cervical curvature and the spatial position of the posterior part of the atlas imaged in the lateral cephalograph. Sixty six patients with temporomandibular disorders(TMD) and twenty dental students were selected for patients group and control group, respectively. The average age of patients group was 26.3 years, and 24.9 years in control group. Measured variables were cervical depth, upper space between the atlas and the base of the occiput, lower space between the atlas and the spinous process of the axis, rea of the posterior part of the atlas imaged in the lateral cephalograph, and the cervical curvature passing through the uppermost point in dorsal side of Dens of the Axis to the lowermost and rearmost point of the 5th cervical vertebra. The reliability of the method used for measuring cervical curvature with curved ruler was also tested. The results obtained were as follows : 1. Cervical depth of patients group was 122.9mm and significantly shorter than that of control group, in which cervical depth was 131.9mm, and cervical depth was significantly correlated with other variables in all subjects. 2. Upper space was greater in patients group, but total space including upper and lower space showed no difference between the two groups. The average value of total space was 26.5mm. 3. Area of the posterior part of the atlas was 168.2$\textrm{mm}^2$ in patients group, and 186.5$\textrm{mm}^2$ in control group with significant difference between the two groups. 4. Average range of radius of cervical curvature were 33-40cm and there was no difference between the two groups. 5. There was no significant correlation between the cervical curvature and the area of the posterior arch of the atlas. 6. The method using curved ruler for measuring cervical curvature could be accepted as a reliable method.

  • PDF

Determination of Sampling Points Based on Curvature distribution (곡률 기반의 측정점 결정 알고리즘 개발)

  • 박현풍;손석배;이관행
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.295-298
    • /
    • 2000
  • In this research, a novel sampling strategy for a CMM to inspect freeform surfaces is proposed. Unlike primitive surfaces, it is not easy to determine the number of sampling points and their locations for inspecting freeform surfaces. Since a CMM operates with slower speed in measurement than optical measuring devices, it is important to optimize the number and the locations of sampling points in the inspection process. When a complete inspection of a surface is required, it becomes more critical. Among various factors to cause shape errors of a final product, curvature characteristic is essential due to its effect such as stair-step errors in rapid prototyping and interpolation errors in NC tool paths generation. Shape errors are defined in terms of the average and standard deviation of differences between an original model and a produced part. Proposed algorithms determine the locations of sampling points by analyzing curvature distribution of a given surface. Based on the curvature distribution, a surface area is divided into several sub-areas. In each sub-area, sampling points are located as further as possible. The optimal number of sub-areas. In each sub-area, sampling points are located as further as possible. The optimal number os sub-areas is determined by estimating the average of curvatures. Finally, the proposed method is applied to several surfaces that have shape errors for verification.

  • PDF

Anisotropic, non-uniform misfit strain in a thin film bonded on a plate substrate

  • Huang, Y.;Ngo, D.;Feng, X.;Rosakis, A.J.
    • Interaction and multiscale mechanics
    • /
    • v.1 no.1
    • /
    • pp.123-142
    • /
    • 2008
  • Current methodologies used for the inference of thin film stresses through curvature measurements are strictly restricted to stress and curvature states which are assumed to remain uniform over the entire film/substrate system. These methodologies have recently been extended to non-uniform stress and curvature states for the thin film subject to non-uniform, isotropic misfit strains. In this paper we study the same thin film/substrate system but subject to non-uniform, anisotropic misfit strains. The film stresses and system curvatures are both obtained in terms of the non-uniform, anisotropic misfit strains. For arbitrarily non-uniform, anisotropic misfit strains, it is shown that a direct relation between film stresses and system curvatures cannot be established. However, such a relation exists for uniform or linear anisotropic misfit strains, or for the average film stresses and average system curvatures when the anisotropic misfit strains are arbitrarily non-uniform.

Energy harvesting characteristics on curvature based PVDF cantilever energy harvester due to vortex induced vibration (곡면을 가진 외팔보형 PVDF 에너지 하베스터의 와류유기진동으로 인한 에너지 수확 특성)

  • Woo-Jin Song;Jongkil Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.2
    • /
    • pp.168-177
    • /
    • 2024
  • When designing an underwater Piezoelectric Energy Harvester (PEH), Vortex Induced Vibration (VIV) is generated throughout the cantilever through a change in curvature, and the generation of VIV increases the vibration displacement of the curved cantilever PEH, which is an important factor in increasing actual power. The material of the curved PEH selected a Polyvinyline Di-Floride (PVDF) piezoelectric film, and the flow velocity is set at 0.1 m/s to 0.50 m/s for 50 mm, 130 mm, and 210 mm with various curvatures. The strain energy change of PEH by VIV was observed. The smaller the radius of curvature, the larger the VIV, and as the flow rate increased, more VIV appeared. Rapid shape transformation due to the small curvature was effective in generating VIV, and strain energy, normalized voltage, average power, etc. To increase the amount of power of the PEH, it is considered that the average power will increase as the number of curved PEHs increases as well as the steep curvature is improved.

A Study of the Characteristics of the Human External Auditory Canal Using 3-Dimensional Medical Imaging (3차원 의료영상을 이용한 인체 외이도 특징에 관한 연구)

  • Kim, Hyeong-Gyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.467-473
    • /
    • 2017
  • Using Digital Imaging and Communications in Medicine(DICOM) and a 3D medical imaging program, the characteristics of the external auditory canal(EAC) were compared. Using images of the ears of 63 different male and female subjects of varying age, this study measured and compared EAC transverse axis lengths, internal diameter circumferences, and upper and lower curvature angles. The findings of the study indicated differences in EAC shapes according not only to age and sex but also to the left and right of the same subject. A comparison between the sexes of the subjects (35 males and 28 females) indicated that, on average, the length of the EAC was 4.75mm longer in males. Based on the lower curvature angle, the interior side of the diameter circumference of the EAC was found to be reduced on average by 37.2% compared to the exterior side. Although the upper curvature angle was on average $25.7^{\circ}$ larger than the lower curvature angle, 4 subjects showed a larger lower curvature angle and large differences between the upper and lower curvature angles were observed in 8 subjects of the younger age group (4~14 years old). This indicated changes in EAC curvature shapes during growth. This study presents a method to raise safety and precision by comparing direct measurements taken through physical means and indirect measurements acquired from existing ear samples. This was possible due to technological developments in which 3D medical image representation technology creates images close to reality, and, through further development, this method is expected to be used for standardization research of EAC shapes.

Comparison of the Editing Method of Missing Area in 3D Scanned Image of Men's Crotch (3차원 스캔한 인체 샅부위의 결측부위 복원 방법 비교)

  • Kim, So-Young;Hong, Kyung-Hi
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.33 no.3
    • /
    • pp.401-409
    • /
    • 2009
  • The shape of crotch area is very important to develop functional clothing as well as other ergonomic goods such as chair or saddle etc. However, it is inevitable that 3D scanned image of crotch would have missing part due to its folded shape including overlapping legs nearby. Therefore, the objectives of this research was to compare reconstruction methods of missing parts at crotch using seven dummies of real men's replicas. Two reconstruction methods adopted were kinds of 'fill- hole' in Rapidform 2004, one was 'smooth' and the other was 'curvature'. Each restored image was compared with the original shape of the dummies. As results, the average distance was 0.66mm between original and 'smooth' treated images and 0.59mm between original and 'curvature' treated, which was not statistically different. Average area of restored crotch region was $8740.04cm^2$ by 'smooth' method and $8405.02cm^2$ by 'curvature' method which is close to the original area of $8413.76cm^2$. Statistical difference was found between images of original and 'smooth' ones$(p=0.04^*)$. However, there was no difference between original and 'curvature' treated images, which indicates that 'curvature' method is more useful to fill the hole compared with 'smooth' method.

A Study on the Moment-Curvature Relation of Hollow RC piers considering Tension Stiffening Effect (인장강성효과를 고려한 중공단면 교각의 모멘트-곡률 관계에 대한 연구)

  • Park Young Ho;Kim Se Hun;Choi Seung Won;Oh Byung Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.17-20
    • /
    • 2005
  • Moment-curvature relation of RC pier is influenced greatly in occurrence form of crack and difference is happened according to consideration existence and nonexistence of tension stiffening effect. However, studies considering these is very insufficient misgovernment. Also, it is sometimes unavoidable lap splice of axial reinforcement in plastic hinge region of RC piers. However, specific design standard about lap splice of axial reinforcement is unprepared real condition and study about effect that lap splice of axial reinforcement get in occurrence form of crack is insufficient misgovernment. Therefore, in this paper, experiments are performed with hollow RC piers that do lap splice of axial reinforcement by main variable. And this study present analytical method about moment-curvature relation of hollow RC pier that consider tension stiffening effect and analyze effect that lap splice of axial reinforcement gets in occurrence form of crack. Analytic method of moment-curvature relation of RC pier that present in this study shows very similar motion with experiment result and crack interval of RC pier is suffering dominate impact in the augmented reinforcement amount by lap splice and average crack interval decreases as lap splice ratio increases.

  • PDF