• 제목/요약/키워드: auxiliary problem

검색결과 255건 처리시간 0.025초

고효율의 PDP 유지 구동 전원단을 위한 새로운 펄스폭 제어방식의 쿼지 공진 컨버터 (A New PWM-Controlled Quasi-Resonant Converter for High Efficiency PDP Sustaining Power Module)

  • 이우진;최성욱;김정은;문건우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.352-355
    • /
    • 2006
  • A new PWM-controlled quasi-resonant converter for high efficiency PDP sustaining power module is proposed in this paper. The load regulation of the proposed converter can be achieved by controlling the ripple of the resonant voltage across the resonant capacitor with hi-directional auxiliary circuit, while the main switches are operating at the fixed duty ratio and fixed switching frequency. Hence, the waveform of currents can be expected to be optimized on the conduction loss. Furthermore, the proposed converter shows the good ZVS capability, simple control circuits, no high voltage ringing problem of rectifier diodes, no DC offset of the magnetizing current and low voltage stress of power switches. In this paper, operational principles, analysis and design considerations are presented. Experimental results demonstrate that the output voltage can be controlled well by the auxiliary circuit as PWM method.

  • PDF

A New PWM-Controlled Quasi-Resonant Converter for a High Efficiency PDP Sustaining Power Module

  • Lee, Woo-Jin;Choi, Seong-Wook;Kim, Chong-Eun;Moon, Gun-Woo
    • Journal of Power Electronics
    • /
    • 제7권1호
    • /
    • pp.28-37
    • /
    • 2007
  • A new PWM-controlled quasi-resonant converter for a high efficiency PDP sustaining power module is proposed in this paper. The load regulation of the proposed converter can be achieved by controlling the ripple of the resonant voltage across the resonant capacitor with a bi-directional auxiliary circuit, while the main switches are operating at a fixed duty ratio and fixed switching frequency. Hence, the waveforms of the currents can be expected to be optimized from the view-point of conduction loss. Furthermore, the proposed converter has good ZVS capability, simple control circuits, no high voltage ringing problem of rectifier diodes, no DC offset of the magnetizing current and low voltage stresses of power switches. In this paper, operational principles, features of the proposed converter, and analysis and design considerations are presented. Experimental results demonstrate that the output voltage can be controlled well by the auxiliary circuit using the PWM method.

라그랑주의 방정식론 (Lagrange and Polynomial Equations)

  • 고영미;이상욱
    • 한국수학사학회지
    • /
    • 제27권3호
    • /
    • pp.165-182
    • /
    • 2014
  • After algebraic expressions for the roots of 3rd and 4th degree polynomial equations were given in the mid 16th century, seeking such a formula for the 5th and greater degree equations had been one main problem for algebraists for almost 200 years. Lagrange made careful and thorough investigation of various solving methods for equations with the purpose of finding a principle which could be applicable to general equations. In the process of doing this, he found a relation between the roots of the original equation and its auxiliary equation using permutations of the roots. Lagrange's ingenious idea of using permutations of roots of the original equation is regarded as the key factor of the Abel's proof of unsolvability by radicals of general 5th degree equations and of Galois' theory as well. This paper intends to examine Lagrange's contribution in the theory of polynomial equations, providing a detailed analysis of various solving methods of Lagrange and others before him.

Zero-Current-Switching in Full-Bridge DC-DC Converters Based on Activity Auxiliary Circuit

  • Chu, Enhui;Lu, Ping;Xu, Chang;Bao, Jianqun
    • Journal of Power Electronics
    • /
    • 제19권2호
    • /
    • pp.353-362
    • /
    • 2019
  • To address the problem of circulating current loss in the traditional zero-current switching (ZCS) full-bridge (FB) DC/DC converter, a ZCS FB DC/DC converter topology and modulation strategy is proposed in this paper. The strategy can achieve ZCS turn on and zero-voltage and zero-current switching (ZVZCS) turn off for the primary switches and realize ZVZCS turn on and zero-voltage switching (ZVS) turn off for the auxiliary switches. Moreover, its resonant circuit power is small. Compared with the traditional phase shift full-bridge converter, the new converter decreases circulating current loss and does not increase the current stress of the primary switches and the voltage stress of the rectifier diodes. The diodes turn off naturally when the current decreases to zero. Thus, neither reverse recovery current nor loss on diodes occurs. In this paper, we analyzed the operating principle, steady-state characteristics and soft-switching conditions and range of the converter in detail. A 740 V/1 kW, 100 kHz experimental prototype was established, verifying the effectiveness of the converter through experimental results.

Minimum Row Weight and Polar Spectrum Based Puncture Polar Codes Construction Algorithm

  • Liu Daofu;Guo Rui
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제17권8호
    • /
    • pp.2157-2169
    • /
    • 2023
  • In order to handle the problem that puncture patterns will change the position distribution of original information bits and frozen bits in polar codes, which affects performance of puncture polar codes further, a minimum row weight and polar spectrum based puncture polar codes construction algorithm (called PA-MRWP) is proposed in this paper. The algorithm calculates row weight of generator matrix and sorts the row weight in ascending order first. Next, the positions with the minimum row weight are selected as initial puncture positions. If the rows with the same row weight cannot all be punctured, polar spectrum based auxiliary puncture scheme is used. In sub-channels with the same row weight, rows corresponding to the polarized sub-channels with higher reliability are selected as puncture positions to construct puncture vector, and the reliability is calculated based on polar spectrum. It is actually a two-step selection strategy, the proposed minimum row weight puncture (MRWP) algorithm is used for primary selection and polar spectrum based auxiliary puncture is used for adjustment. Simulation results show that, compared with worst quality puncture (WQP) algorithm, the proposed PA-MRWP algorithm and Gaussian approximation-aided minimum row weight puncture (GA-MRWP) algorithm provide gains of about 0.46 dB and 0.29 dB at bit error rate (BER) of 10-4, respectively when code length N=400, code rate R=1/2. In addition, the proposed puncture algorithms improve the BER performance significantly with respect to quasi-uniform puncture (QUP) algorithm.

Sensor and actuator design for displacement control of continuous systems

  • Krommer, Michael;Irschik, Hans
    • Smart Structures and Systems
    • /
    • 제3권2호
    • /
    • pp.147-172
    • /
    • 2007
  • The present paper is concerned with the design of distributed sensors and actuators. Strain type sensors and actuators are considered with their intensity continuously distributed throughout a continuous structure. The sensors measure a weighted average of the strain tensor. As a starting point for their design we introduce the concept of collocated sensors and actuators as well as the so-called natural output. Then we utilize the principle of virtual work for an auxiliary quasi-static problem to assign a mechanical interpretation to the natural output of the sensors to be designed. Therefore, we take the virtual displacements in the principle of virtual work as that part of the displacement in the original problem, which characterizes the deviation from a desired one. We introduce different kinds of distributed sensors, each of them with a mechanical interpretation other than a weighted average of the strain tensor. Additionally, we assign a mechanical interpretation to the collocated actuators as well; for that purpose we use an extended body force analogy. The sensors and actuators are applied to solve the displacement tracking problem for continuous structures; i.e., the problem of enforcing a desired displacement field. We discuss feed forward and feed back control. In the case of feed back control we show that a PD controller can stabilize the continuous system. Finally, a numerical example is presented. A desired deflection of a clamped-clamped beam is tracked by means of feed forward control, feed back control and a combination of the two.

견실성능 최적화를 위한 혼합 H_2/H_{\infty}$ 제어기설계 알고리즘 (Mixed H_2/H_{\infty}$ controller design algorithm for robust performance optimization)

  • 김종해;방경호;박홍배
    • 전자공학회논문지B
    • /
    • 제33B권5호
    • /
    • pp.10-16
    • /
    • 1996
  • In this paper, we consider a generalized mixed H_2/H_{\infty}$ output feedback problem. It is finding an internally stabilizing controller that minimizes a mixed $H_{2}$/ $H_{performance}$ measure. We show that a generalized mixed H_2/H_{\infty}$ system with two exogenous inputs and two controlled signals is transformed into auxiliary system with two exogenous inputs and one controlled signal. The two systems have equivalent performance. Therefore, a complete solution of generalized mixed H_2/H_{\infty}$ output feedback problem is achieved by existing results of mixed H_2/H_{\infty}$ control theory.

  • PDF

Mode Decomposition of Three-Dimensional Mixed-Mode Cracks using the Solution for Penny-Shaped Crack

  • Kim, Young-Jong;Cho, Duk-Sang
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제2권3호
    • /
    • pp.11-18
    • /
    • 2001
  • A simple and convenient method of analysis for obtaining the individual stress intensity factors in a three-dimensional mixed mode crack is proposed. The procedures presented here are based on the path independence of J integral and mutual or two-state conservation integral, which involves two elastic fields. The problem is reduced to the determination of mixed mode stress intensity factor solutions in terms of conservation integrals involving known auxiliary solutions. Some numerical examples are presented to investigate the effectiveness and applicability of the method for a three-dimensional penny-shaped crack problem under mixed mode. This procedure is applicable to a three-dimensional mixed mode curved crack.

  • PDF

고분자 전해질 연료전지와 슈퍼캐패시터 하이브리드 시스템의 운전 전략에 관한 연구 (Study of Operation Strategy for Hybrid PEM Fuel Cell and Supercapacitor)

  • 박광진;지현진;배중면
    • 대한기계학회논문집B
    • /
    • 제30권8호
    • /
    • pp.756-763
    • /
    • 2006
  • PEMFC has several technical problems such as water management, long term stability and performance degradation as. PEMFC has been studied not only to solve water management, but also to generate power in stable manner to system by using a hybrid system with auxiliary energy storage device. The purpose of this study is to couple PEMFC with supercapacitor to make a hybrid system and to design and test control strategies for stable power generation in case of changing output power. The polarization curve and dynamic behaviors while changing power were investigated to find out characteristics of PEMFC stack. A DC/DC converter was fabricated in order to increase fuel cell and supercapacitor voltage and to charge supercapacitor. We found that the operation strategy 2 was recommended to the system because of solving water management problem and increasing the dynamic behavior.

벤치마크 태그를 이용한 도착시간 차 기반의 RFID 측위 알고리즘 (TDOA-Based Localization Algorithms for RFID Systems Using Benchmark Tags)

  • 주운기
    • 경영과학
    • /
    • 제29권3호
    • /
    • pp.1-11
    • /
    • 2012
  • This paper considers a localization problem in time difference of arrival (TDOA)-based radio frequency identification (RFID) systems. To estimate the position of a target tag, this paper suggests three localization algorithms that use benchmark tags. The benchmark tags are the same type as the target tag, but either the locations or distance of the benchmark tags are known. Two algorithms use the benchmarks for auxiliary information to improve the estimation accuracy of the other localization algorithms such as least squared estimator (LSE). The other one utilizes the benchmarks as essential tags to estimate the location. Numerical tests show that the localization accuracy can be improved by using benchmark tags especially when an algorithm using the LSE is applied to the localization problem. Furthermore, this paper shows that our benchmark algorithm is valuable when the measurement noise is large.