• 제목/요약/키워드: automated counting

검색결과 34건 처리시간 0.023초

컴퓨터 이미지 분석법을 이용한 마우스 골수세포에서 소핵의 계수 (Computerized Image Analysis of Micronucleated Reticulocytes in Mouse Bone Marrow)

  • 권정;홍미영;고우석;정문구;이미가엘
    • Toxicological Research
    • /
    • 제18권4호
    • /
    • pp.369-374
    • /
    • 2002
  • The present study was performed to validate an automated image analysis system (Loats Automated Micronucleus Scoring System) for the mouse bone marrow micronucleus assay, comparing with conventional microscopic scoring. Two studies were conducted to provide slides for a comparison of micro-nucleated polychromatic erythrocytes (MNPCEs) values collected manually to those collected by the auto-mated system. Test article A was used as an example of a compound negative for the induction of micronuclei and test article B was wed as a micronucleus-inducing agent to elicit a positive response. Cyclophosphamide was included to provide an positive control in two studies. Bone marrow samples were collected 24 h after administration of test article A and B in male ICR mice. The cells were fixed with absolute methanol and stained with May-Grunwald and Giemsa. The number of MNPCEs was determined by the analysis of 1000 total PCEs per bone marrow sample. In addition to micronucleus scoring, an index of bone marrow toxicity based on PCE ratio (% of PCEs to total erythrocytes) was determined for each sample. The automated and manual scoring was similar when the MNPCEs incidence induced by each test article was less than 10. However manual scoring was able to effectively enumerate micronucleated PCEs in mouse bone marrow when MNPCEs incidence was more than 10, such as cyclophosphamide treatment. Conversely, PCE ratio was superior in computer-assisted image analysis. Taken together, it is suggested that improvement of the automated image analysis may be necessary to render the automatic scoring as sensitive as manual scoring for routine counting of micronuclei, especially because it is superior in objectivity and high throughput scoring.

오픈 소스 라이브러리를 활용한 HCS 소프트웨어 개발 (Development of HCS(High Contents Screening) Software Using Open Source Library)

  • 나예지;호종갑;이상준;민세동
    • 정보처리학회논문지:소프트웨어 및 데이터공학
    • /
    • 제5권6호
    • /
    • pp.267-272
    • /
    • 2016
  • 생물정보학분야에서 현미경을 통해 얻은 세포 영상은 생물학적 정보를 얻기 위한 중요한 지표이다. 연구자들은 영상을 육안으로 분석하기 때문에 분석에 많은 시간과 고도의 집중력이 요구된다. 게다가 연구자의 주관적 관점이 분석에 개입되어 결과를 객관적으로 정량화하는데 어려움이 있다. 따라서 본 연구에서는 OpenCV 라이브러리를 이용하여 세포의 자동 분석을 위한 HCS(High Content Screen) 알고리즘을 개발하였다. HCS 알고리즘은 이미지 전처리 과정, 세포 계수, 세포 주기와 분열지수 분석 기능을 포함한다. 본 연구에서는 공초점 레이저 현미경을 통해 얻은 위암세포(MKN-28) 영상을 분석에 사용하였으며, 성능 평가를 위해 세포영상 분석 프로그램인 ImageJ와 전문 연구원의 세포 계수 분석결과를 비교하였다. 실험 결과 HCS 알고리즘의 평균 정확성이 99.7%로 나타났다.

석면섬유 자동계수를 위한 고효율 현미경법의 영상처리 알고리즘 개선 (Improvement of Image Processing Algorithm of High-Throughput Microscopy for Automated Counting of Asbestos Fibers)

  • 조명옥;윤성희;한화택;김중경
    • 한국가시화정보학회지
    • /
    • 제13권3호
    • /
    • pp.15-19
    • /
    • 2015
  • We developed a high-throughput microscopy (HTM) method which enabled us to replace a conventional phase contrast microscopy (PCM) method that has been used as a standard analytical method for airborne asbestos. We could obtain the concentration of airborne asbestos fibers under detection limit by automated image processing and analysis using HTM method. Here we propose an improved image processing algorithm with variable parameters to enhance the accuracy of the HTM analysis. Since the variable parameters that compensate the difference of the brightness are applied to the individual images in our new image processing method, it is possible to enhance the accuracy of the automatic image analysis method for sample slides with low asbestos concentration that caused errors in binary image processing. We demonstrated that enumeration of fibers by improved image processing algorithm remarkably enhanced the accuracy of HTM analysis in comparison with PCM. The improved HTM method can be a potential alternative to conventional PCM.

영상인식 기술을 이용한 프로젝션용접 자동화시스템 (An Automated Projection Welding System using Vision Processing Technique)

  • 박기정;송하주
    • 한국전자통신학회논문지
    • /
    • 제6권4호
    • /
    • pp.517-522
    • /
    • 2011
  • 수작업에 의한 기존의 프로젝션(projection) 용접시스템은 작업자의 부주의로 인한 불량이 자주 발생한다. 본 논문에서는 비전카메라를 사용하여 부품과 제품의 인식, 용접 및 수량 관리를 자동으로 수행하는 프로젝션 용접시스템을 제안한다. 제안 시스템은 비전카메라를 사용하여 용접에 사용되는 부품의 유무와 놓인 상태를 검사한다. 그리고 부품의 용접 후에는 제품 수량 카운터와 드레싱 등의 항목을 자동 갱신한다. 기존 시스템과의 비교 실험을 통해 불량률을 감소시키고 생산성을 높일 수 있음을 보인다.

컬러 정보를 이용한 지능형 결핵균 검출 자동화 시스템 (Intelligent Automated Detection System of Tuberculosis Bacilli by Using Their Color Information)

  • 조성만;김기범;임충혁;주원종
    • 한국정밀공학회지
    • /
    • 제24권11호
    • /
    • pp.126-133
    • /
    • 2007
  • Tuberculosis (TB) is a chronic or acute infectious disease which damages more people than any other infectious diseases according to WHO estimates. In this paper, a new automatic detection system of tuberculosis bacilli by using their color information is proposed. Through the deep investigation of color and intensity compositions of tuberculosis images, new pre-processing and segmentation algorithms are suggested. Specific features of bacilli are extracted from the processed images and number counting is done by using domain-specific knowledge rules.

SYSTEMATIC INCREASE OF DUST SIZE TOWARD THE CENTER OF B361

  • Hong, S.S.;Koo, B.C.;Yun, H.S.
    • 천문학회지
    • /
    • 제24권1호
    • /
    • pp.107-116
    • /
    • 1991
  • With a modern microdensitometer and POSS glass copies, we have performed an automated star counting in two colors, blue and red, over the region containing Bok globule B361. Distribution of the measured extinction values over the projected angular distance from the cloud center was approximated by a power-law, and the resulting power-law indices for the blue and red are shown to be distinctly different from each other. The difference in the power-law index indicates that the mean dust size increases towards the cloud center. Possible physical causes for such size variation are briefly discussed.

  • PDF

소아 환자에서 미다졸람의 경구 투여와 근육 투여에 의한 진정 효과의 비교 연구 (THE COMPARATIVE STUDY ON THE SEDATIVE EFFECT OF ORAL MIDAZOLAM AND INTRAMUSCULAR MIDAZOLAM IN SEDATING YOUNG PEDIATRIC DENIAL PATIENTS)

  • 민유진;유승훈;김종수
    • 대한소아치과학회지
    • /
    • 제33권1호
    • /
    • pp.53-61
    • /
    • 2006
  • 미다졸람은 소아 환자의 진정시 흔히 사용되는 약물로서 안전성이 뛰어나고 사용이 편리하며 투여 방법이 다양하다. 여러 투여 방법 중, 주로 사용되는 근육내 투여 방법은 동통을 유발하기 때문에 어린이의 치과에 대한 공포를 가중시킬 수 있다. 따라서 근육내 투여의 이런 단점을 완화할 수 있도록 용량에 따른 미다졸람 경구 투여의 진정 효과를 근육내 투여시의 진정 효과와 비교 평가하고자 하였다. 총 12명의 환자를 실험대상으로 하였으며 이중 맹검법에 의해 두 번의 내원중 임의로 한 번은 Midazolam 0.75 mg/kg을 경구 투여하고, 한 번은 미다졸람 0.3mg/kg을 근육내 투여하여 치료하였으며, 치료과정 동안 환자의 생징후(말초 동맥혈 산소 포화도, 심박수)와 행동양상을 Ohio State University Behavior rating scale과 Automated Counting System을 사용하여 평가하였다. 생징후의 경우 양 군 모두 정상범위 내에서 안정된 양상을 보였으며, 임상적으로 바람직한 행동양상(Q:Quiet)의 비율이양 군에서 대부분 높게 나타났으며 양군간에 유의 한 차이를 보이지 않았다(p>0.05). 본 연구에서 미다졸람을 근육내 투여한 군과 경구 투여한 군 모두 진정 효과가 양호한 결과를 보였으며 양군간에 유의한 차이를 보이지 않았다(pgt;0.05).

  • PDF

XN-9000장비에서 Low Level QC물질에서의 혈소판 수 관리와 용혈에 따른 P-LCR의 변화 (Maintenance of Platelet Counts with Low Level QC Materials and the Change in P-LCR according to Hemolysis with XN-9000)

  • 심문정;이현아
    • 대한임상검사과학회지
    • /
    • 제50권4호
    • /
    • pp.399-405
    • /
    • 2018
  • 임상검사실에서의 혈소판 수 계산은 지혈이상의 진단과 치료에 필수적이며, 혈소판 수가 적은 경우 혈소판 수혈이 필요하고 항암치료 후 혈소판 수 경과를 모니터링하는데 매우 중요하다. 정도관리는 환자결과를 내보내기 전에 검사실에서 오류를 줄이고 교정하는 과정이며 분절된 적혈구는 혈소판과 크기가 비슷하여 혈소판 수 계산에 영향을 미친다. 검사실에서 내부정도관리low QC물질이 2SD를 벗어난 것을 경험하였고, 지금까지 용혈과 혈소판 지표들과의 관계에 대해 밝혀진 것이 충분하지 않아 연구를 시작하였다. 이에 본 연구에서는 XN CHECK low level QC물질을 이용해 PLT-I, PLT-O, PLT-F 방법간의 혈소판 수치를 비교하였으며, 용혈검체를 만들어 5가지 혈소판지표들에 대해 비교분석 하였다. 그 결과PLT-F방법에서 CV값이 가장 적게 나타났으며, 용혈검체에서 P-LCR 수치가 18.4%에서 31.9%로 증가함을 보였다. 이 연구를 통해 혈소판 수치가 낮은 경우는 PLT-F방법으로 하는 것이 더 정확하며, 검체가 용혈이나 변질이 의심되는 경우 이를 평가할 때 P-LCR을 새로운 지표로 제시하고 있으며, 사람 혈액검체를 이용한 추후 연구가 더 필요할 것이라고 사료된다.

다수의 계수구역간의 검사체적을 이용한 소형 세포농도센서 (Micro Cell Counter Using a Fixed Control Volume Between Double Electrical Sensing Zones)

  • 이동우;이소연;조영호
    • 대한기계학회논문집A
    • /
    • 제29권12권
    • /
    • pp.1615-1620
    • /
    • 2005
  • We present a novel flow-rate independent cell counter using a fixed control volume between double electrical sensing zones. The previous device based on the single electrical cell sensing in a given flow-rate requires an accurate fluid volume measurement or precision flow rate control. The present cell counter, however, offers the flow-rate independent method for the cell concentration measurement with counting cells in a fixed control volume of $22.9{\pm}0.98{\mu}{\ell}$. In the experimental study, using the RBC (Red Blood Cell), we have compared the measured RBC concentrations from the fabricated devices with those from Hemacytometer. The previous and present devices show the maximum errors of $20.3\%\;and\;16.1\%$, which are in the measurement error range of Hemacytometer (about $20\%$). The present device also shows the flow-rate independent performance at the constant flow-rates ($5{\mu}{\ell}/min$ and $10{\mu}{\ell}/min$) and the varying flow-rate (4, 2, and $4{\mu}{\ell}/min$). Therefore, we demonstrate that the present cell counter is a simple and automated method for the cell concentration measurement without requiring an accurate fluid measurement and precision flow-rate control.

퍼지 추론을 이용한 REM의 자동 검출 : 기면증과 정상수면의 REM 분포 연구 (Automatic Detection of Rapid Eye Movement Distribution in Narcoleptic and Normal Sleep Using Fuzzy Logic)

  • 박해정;한주만;최미혜;정도언;박광석
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.201-202
    • /
    • 1998
  • In this paper we suggested an automated method for detecting and counting rapid eye movement(REM) using EOG during sleep. This method is formulated by two step fuzzy logic. At first step, the velocity and the distance of single channel eye movement are used for the fuzzy input to get the possibility of being REM at each EOG. At second step, the two possibility values of both EOG from the first step and the correlation coefficient of both eye movements are used for the fuzzy logic input, and the output is the final possibility of being Rapid Eye Movement. We applied this algorithm to the normal and narcoleptic sleep data and compared the difference. We found the possibility that the count of REM can be a parameter that has significant physiological meanings.

  • PDF