Browse > Article
http://dx.doi.org/10.15324/kjcls.2018.50.4.399

Maintenance of Platelet Counts with Low Level QC Materials and the Change in P-LCR according to Hemolysis with XN-9000  

Shim, Moon-Jung (Department of Clinical Laboratory Science, Ansan University)
Lee, Hyun-A (Department of Laboratory Medicine, Korea University Medical Center, Ansan Hospital)
Publication Information
Korean Journal of Clinical Laboratory Science / v.50, no.4, 2018 , pp. 399-405 More about this Journal
Abstract
The platelet count in clinical laboratories is essential for the diagnosis and treatment of hemostasis abnormalities, and accurate platelet counting in the low count range is of prime importance for deciding if a platelet transfusion is needed and for monitoring after chemotherapy. Quality control is designed to reduce and correct any deficiencies in the internal analytical process of a clinical laboratory prior to the release of patient results. Fragmented erythrocytes are the major confusing factors for platelet counting because of their similar size to platelets. The authors found that the low range QC values were out of 2SD with a Sysmex automatic analyzer in internal quality control process. Thus far, there has been little discussion on the relationship between hemolysis and the platelet parameters. Therefore, this study focused on the performance of automated platelet counts, including the PLT-F, the PLT-I, and PLT-O methods at the low platelet range using the low level QC materials and compared the 5 platelet parameters with the hemolyzed samples. The results showed that the CV was the smallest with PLT-F and P-LCR increased from 18.4 to 31.9% in the hemolysis samples. These results indicate that a more accurate estimation of the platelet counts can be achieved using the PLT-F method than the PLT-I method at the low platelet range. The use of the PLT-F system improves the confidence of results in low platelets samples in a routine hematology laboratory. The results suggest that P-LCR is a new parameter in assessing samples when the specimen is suspected of hemolysis and deterioration. Nevertheless, further studies will be needed to establish the relationship with P-LCR and hemolysis using human blood specimens.
Keywords
Hemolysis; Platelet large cell ratio; platelet counting with fluorescence; Quality control; XN 9000;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Segal HC, Briggs C, Kunka S, Casbard A, Harrison P, Machin SJ, et al. Accuracy of platelet counting haematology analyzers in severe thrombocytopenia and potential impact on platelet transfusion. Br J Haematol. 2005;128:520-525.   DOI
2 Saliba RM, Komanduri KV, Giralt S, de Souza J, Patah P, Oran B, et al. Leukemia burden delays lymphocyte and platelet recovery after allo-SCT for AML. Bone Marrow Transplant. 2009;43:685-692.   DOI
3 Briggs C, Harrison P, Machin SJ. Continuing developments with the automated platelet count. Int J Lab Hematol. 2007;29:77-91.   DOI
4 Briggs C, Longair I, Kumar P, Singh D, Machin SJ. Performance evaluation of Sysmex haematology XN modular system. J Clin Pathol. 2012;65:1024-1030.   DOI
5 Briggs C, Kunka S, Machin SJ. The most accurate platelet count on the Sysmex XE-2100: optical or impedance? Clin Lab Haematol. 2004;26:157-158.   DOI
6 Schoorl M, Schoorl M, Oomes J, van Pelt J. New fluorescent method (PLT-F) on Sysmex XN2000 hematology analyzer achieved higher accuracy in low platelet counting. Am J Clin Pathol. 2013;140:495-499.   DOI
7 Niethammer AG and Forman EN. Use of the platelet histogram maximum in evaluating thrombocytopenia. Am J Hematol. 1999;60:19-23.   DOI
8 Park Y, Schoene N, Harris W. Mean platelet volume as an indicator of platelet activation: methodological issues. Platelets. 2002;13:301-306.   DOI
9 Wada A, Takagi Y, Kono M, Morikawa T. Accuracy of a new platelet count system (PLT0F) depends on the staining property of its reagents. PLoS One. 2015;10:1-13.
10 Grotto H, Noronha J. Platelet larger cell ratio (P-LCR) in patients with dyslipidemia. Clin Lab Haematol. 2004;26:347-349.   DOI
11 Briggs C, Harrison P, Grant D, Staves J, MacHin SJ. New quantitative parameters on a recently introduced automated blood cell counter: the XE2100. Clin Lab Haematol. 2000;22:345-350.   DOI
12 Tanaka Y, Tanaka Y, Gondo K, Maryki Y, Kondo T, Asai S, et al. Performance evaluation of platelet counting by novel fluorescent dye staining in the XN-series automated hematology analyzers. J Clin Pathol. 2014;28:341-348.
13 Tantanate C, Khowawisetsut L, Pattanapanyasat K. Performance evaluation of automated impedance and optical fluorescence platelet counts compared with international reference method in patients with thalassemia. Arch Pathol Lab Med. 2017;141:830-836.   DOI
14 Zandecki M, Genevieve F, Gerard J, Godon A. Spurious counts and sprious results on haematology analyzers. Int J Lab Hematol. 2007;29:4-20.
15 Siegenthaler M, Spertini O. Images in clinical medicine: spurious platelet count. N Engl J Med. 2006;354:1936.   DOI
16 Tantanate C. Spuriously high platelet counts by various automated hematology analyzers in patient with disseminated intravascular coagulation. Clin Chem Lab Med. 2015;53:257-259.