Auto Calibration and Simulation Method for a Strain Gage Type Transducer/Signal Conditioner (스트레인 게이지형 센서 신호조정기 자동교정 및 시뮬레이션 기법)

  • 유제택
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.12
    • /
    • pp.1019-1025
    • /
    • 2003
  • We introduce a new auto-calibration/simulation method for a strain gage type transducer/signal-conditioner which guarantees the output linearity and compensates the error automatically. We design a micro voltage supply which is able to interface either AC or DC type excitation voltage. A new strain gage simulator is also designed. We make linearity output of the signal conditioner and can compensate error automatically with this new auto calibration/simulation method. The experimental results show that the error between the real value and the expected one is less than 1%.

Comparison on the Error Rates of Calibration Modes in Intervention (인터벤션에서 Calibration Mode에 대한 오차율 비교)

  • Kong, Chang gi;Ryu, Young hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.619-626
    • /
    • 2020
  • This study aimed to identify the error rates in Catheter Calibration Mode, Auto Calibration Mode, and Segment Calibration Mode among many calibration modes as a quantitative evaluation tool used for predicting the diameter and length of balloon or stent in percutaneous intravascular balloon dilatation or stent insertion. Our experiment was conducted with Copper Wire of 2 mm × 80 mm (diameter × length) manufactured elaborately for quantitative evaluation in calibration and Metal Ball of 5, 10, 15, 30, and 40 mm and Acryl Phantom of 25 mm, 50 mm, 75mm, 100 mm, 125 mm, 150mm, 175 mm, and 200 mm. At each height, subtraction images were acquired with a cineangiograph and Stenosis Analysis Tool as a software provided by the equipment company was used for measurement. To evaluate the error rates in Catheter Calibration Mode, Copper Wire was put on each acryl phantom before shooting. Copper Wire of 2 mm in diameter was set as a diameter for catheter, and Copper Wire of 8 mm in length was measured with Multi-segments. As a result, the error rates appeared at 1.13 ~ 5.63%. To evaluate the error rates in Auto Calibration Mode, the height of acryl was entered at each height of acryl phantom and the length of 8 mm Copper Wire was measured with Multi-segments and as a result, the error rates appeared at 0 ~ 0.26%. To evaluate the error rates in Segment Calibration Mode, each metal ball on the floor of table was calibrated and the length of 8 mm Copper Wire on each acryl phantom was measured and the length of 8 mm Copper Wire depending on the changes of acryl phantom height was measured with Mutli-segments and as a result, the error rates appeared at 1.05 ~ 19.04%. And in the experiment on OID changes in Auto Calibration Mode, the height of acryl phantom was fixed at 100mm and OID only changed within the range of 450 mm ~ 600 mm and as a result, the error rates appeared at 0.13 ~ 0.38%. In conclusion, it was found that entering the height values in Auto Calibration Mode, among these Calibration Modes for evaluating quantitative vascular dimensions provided by the software was the calibration method with the least error rates and it is thus considered that for calibration using a metal ball or other objects, putting them in the same height as that of treatment sites before calibrating is the method that can reduce the error rates the most.

Calibration of index tables using electric comparators (전기 마이크로미터를 이용한 회전 눈금원판의 교정)

  • Nam, Ki-Chul;Woo, In-Hun;Kim, Jong-Su;Lim, Jae-Sun;Chung, Myung-Se
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.4 no.4
    • /
    • pp.36-42
    • /
    • 1987
  • Very accurate calibration is needed to index tables which are necessary for precision angle measurement. The repeatability of index table is less than 0.2 second, so that attentions should be paid to choosing devices to be used in the calibration of index tables. The auto- collimators have been used in the calibration of index tables, but the repeatability of auto- collimators is bad compared with that of index table. In place of autocollimators, we described a method which uses electric comparators which are possessed by most precision measurement laboratories. Electric comparators are set to measure small angle displacement without interrupting the rotation of index tables and the signals of two electric comparators are added to remove the run-out errors of the shafts of index tables. Two index tables have been calibrated simulataneously by this method and the measurement data have been analyzed by the least squares method. We compare the calibration results with those of methods using autocollimator and auto- matic autocollimator and are able to know that the data of electric comparator method lie between the data of autocollimator methods. The repeatability of measurement is less than 0.02 second. The electric comparator method is economical and capable of reducing the uncertainty of the measurement.

  • PDF

A Development of Auto-Calibration for Initial Soil Condition in K-DRUM Model (K-DRUM 개선을 위한 초기토양함수 자동보정기법 개발)

  • Park, Jin-Hyeog;Hur, Young-Teck
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.17 no.2
    • /
    • pp.71-79
    • /
    • 2009
  • In this study, a distributed rainfall-runoff model, K-DRUM, based on physical kinematic wave was developed to simulate temporal and spatial distribution of flood discharge considering grid rainfall and grid based GIS hydrological parameters. The developed model can simulate temporal and spatial distribution of surface flow and sub-surface flow during flood period, and input parameters of ASCII format as pre-process can be extracted using ArcView. Output results of ASCII format as post-process can be created to express distribution of discharge in the watershed using GIS and express discharge as animation using TecPlot. an auto calibration method for initial soil moisture conditions that have an effect on discharge in the physics based K-DRUM was additionally developed. The baseflow for Namgang Dam Watershed was analysed to review the applicability of the developed auto calibration method. The accuracy of discharge analysis for application of the method was evaluated using RMSE and NRMSE. Problems in running time and inaccuracy setting using the existing trial and error method were solved by applying an auto calibration method in setting initial soil moisture conditions of K-DRUM.

  • PDF

Semi-Auto Camera Calibration Method for 3D Information Generation (3차원 공간정보 생성을 위한 반자동 카메라 교정 방법)

  • Kim, Hyungtae;Paik, Joonki
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.5
    • /
    • pp.127-135
    • /
    • 2015
  • In this paper, we propose the semi-auto camera calibration method including user input. The proposed method estimates the vanishing points using user defined reference lines and defines the constraint for reducing outlier in vanishing points estimation process. The proposed camera calibration method based on both algebraic and geometric method improves a calibration performance for difficult condition, which represents that existing method can't calibrate a image. Experimental results show that the proposed method calibration accuracy higher than existing method.

Development of Clutch Auto Calibration Algorithm for Automatic Transmission Shift Quality Improvement (자동변속기 변속품질 향상을 위한 클러치 자동보정 알고리즘 개발)

  • Jung, Gyuhong
    • Journal of Drive and Control
    • /
    • v.17 no.3
    • /
    • pp.47-56
    • /
    • 2020
  • As a shift control of automatic transmission was managed with the electronic control unit (ECU), shift quality which is a measure of shift shock during gear change has markedly improved. However, the initial clutch pressure control of the clutch filling phase should continue to rely on the predetermined control input since the input and output speeds are unchanged until the shifting process attains the inertia phase. It is critical to minimize the clutch response time and control the clutch pressure accurately at the end of clutch fill to achieve quick shift response and smoothness. Advanced transmission companies have adopted an auto calibration method which establishes the databases for the clutch piston fill-up attributes and the frictional characteristics of the disks. In this study, a distinctive auto calibration algorithm for forklift transmission under development is proposed and verified with the real-vehicle test. The experimental calibration results showed consistent turbine dynamics at the initial stage of shifts with the properly calibrated clutch-fill control parameters. By using this technique, it is necessary to finalize the shift control for the various operation conditions.

PRINCIPAL COMPONENTS BASED SUPPORT VECTOR REGRESSION MODEL FOR ON-LINE INSTRUMENT CALIBRATION MONITORING IN NPPS

  • Seo, In-Yong;Ha, Bok-Nam;Lee, Sung-Woo;Shin, Chang-Hoon;Kim, Seong-Jun
    • Nuclear Engineering and Technology
    • /
    • v.42 no.2
    • /
    • pp.219-230
    • /
    • 2010
  • In nuclear power plants (NPPs), periodic sensor calibrations are required to assure that sensors are operating correctly. By checking the sensor's operating status at every fuel outage, faulty sensors may remain undetected for periods of up to 24 months. Moreover, typically, only a few faulty sensors are found to be calibrated. For the safe operation of NPP and the reduction of unnecessary calibration, on-line instrument calibration monitoring is needed. In this study, principal component-based auto-associative support vector regression (PCSVR) using response surface methodology (RSM) is proposed for the sensor signal validation of NPPs. This paper describes the design of a PCSVR-based sensor validation system for a power generation system. RSM is employed to determine the optimal values of SVR hyperparameters and is compared to the genetic algorithm (GA). The proposed PCSVR model is confirmed with the actual plant data of Kori Nuclear Power Plant Unit 3 and is compared with the Auto-Associative support vector regression (AASVR) and the auto-associative neural network (AANN) model. The auto-sensitivity of AASVR is improved by around six times by using a PCA, resulting in good detection of sensor drift. Compared to AANN, accuracy and cross-sensitivity are better while the auto-sensitivity is almost the same. Meanwhile, the proposed RSM for the optimization of the PCSVR algorithm performs even better in terms of accuracy, auto-sensitivity, and averaged maximum error, except in averaged RMS error, and this method is much more time efficient compared to the conventional GA method.

Auto-calibration for the SWAT Model Hydrological Parameters Using Multi-objective Optimization Method (다중목적 최적화기 법을 이용한 SWAT 모형 수분매개변수의 자동보정)

  • Kim, Hak-Kwan;Kang, Moon-Seong;Park, Seung-Woo;Choi, Ji-Yong;Yang, Hee-Jeong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.1
    • /
    • pp.1-9
    • /
    • 2009
  • The objective of this paper was to evaluate the auto-calibration with multi-objective optimization method to calibrate the parameters of the Soil and Water Assessment Tool (SWAT) model. The model was calibrated and validated by using nine years (1996-2004) of measured data for the 384-ha Baran reservoir subwatershed located in central Korea. Multi-objective optimization was performed for sixteen parameters related to runoff. The parameters were modified by the replacement or addition of an absolute change. The root mean square error (RMSE), relative mean absolute error (RMAE), Nash-Sutcliffe efficiency index (EI), determination coefficient ($R^2$) were used to evaluate the results of calibration and validation. The statistics of RMSE, RMAE, EI, and $R^2$ were 4.66 mm/day, 0.53 mm/day 0.86, and 0.89 for the calibration period and 3.98 mm/day, 0.51 mm/day, 0.83, and 0.84 for the validation period respectively. The statistical parameters indicated that the model provided a reasonable estimation of the runoff at the study watershed. This result was illustrated with a multi-objective optimization for the flow at an observation site within the Baran reservoir watershed.

A Simple Auto Calibration Method for CCD Camera With High Distortion Lens (왜곡율이 큰 렌즈가 부착된 CCD 카메라를 위한 간단한 자동 보정 방법)

  • 한기태;김회율
    • Journal of Broadcast Engineering
    • /
    • v.5 no.2
    • /
    • pp.260-272
    • /
    • 2000
  • In this paper, we propose a simple auto calibration method for a CCD camera with wide an91e lens that causes high degree of distortion. We formulate a cubic warping equation for the relationship between the cross points on the distorted calibration target and the corresponding points from the standard grid image, and calibrate distorted images using the computed parameters. The experiment has been performed with the distorted images resulted from wide angle CCD camera. The experimental results show that the proposed method, in terms of the average and maximum distorted error, has higher accuracy than the existing methods because of maintaining the calibration ratio more than 95 percent. The proposed method is applicable to wide variety of images regardless a type of lens or distortion.

  • PDF

Precise Indoor Localization System for a Mobile Robot Using Auto Calibration Algorithm (Auto Calibration Algorithm을 이용한 이동 로봇의 정밀 위치추정 시스템)

  • Kim, Sung-Bu;Lee, Jang-Myung
    • The Journal of Korea Robotics Society
    • /
    • v.2 no.1
    • /
    • pp.40-47
    • /
    • 2007
  • Recently, with the development of service robots and with the new concept of ubiquitous world, the position estimation of mobile objects has been raised to an important problem. As pre-liminary research results, some of the localization schemes are introduced, which provide the absolute location of the moving objects subjected to large errors. To implement a precise and convenient localization system, a new absolute position estimation method for a mobile robot in indoor environment is proposed in this paper. Design and implementation of the localization system comes from the usage of active beacon systems (based upon RFID technology). The active beacon system is composed of an RFID receiver and an ultra-sonic transmitter: 1. The RFID receiver gets the synchronization signal from the mobile robot and 2. The ultra-sonic transmitter sends out the traveling signal to be used for measuring the distance. Position of a mobile robot in a three dimensional space can be calculated basically from the distance information from three beacons and the absolute position information of the beacons themselves. Since it is not easy to install the beacons at a specific position precisely, there exists a large localization error and the installation time takes long. To overcome these problems, and provide a precise and convenient localization system, a new auto calibration algorithm is developed in this paper. Also the extended Kalman filter has been adopted for improving the localization accuracy during the mobile robot navigation. The localization accuracy improvement through the proposed auto calibration algorithm and the extended Kalman filter has been demonstrated by the real experiments.

  • PDF