• Title/Summary/Keyword: asphalt mixtures

Search Result 230, Processing Time 0.017 seconds

Evaluation of Moisture Susceptibility of Asphalt Mixtures Using Boiling Water Test (보일링 시험을 통한 아스팔트 혼합물의 수분민감성 평가)

  • Kim, Jun;Park, Dae-Wook;Vo, Viet Hai;Kim, Hyeok-Jung;Park, Jun-Sang
    • International Journal of Highway Engineering
    • /
    • v.17 no.1
    • /
    • pp.77-82
    • /
    • 2015
  • PURPOSES : The purpose of this paper is to evaluate the moisture susceptibility of asphalt mixtures containing developed liquid anti-stripping agents using the boiling water test as a screening test. METHODS : The boiling water test was used to evaluate the moisture susceptibility of asphalt mixtures containing different anti-stripping agents. The tensile strength ratio was calculated to compare the moisture susceptibility of the asphalt mixtures after indirect strength tests were performed. Additionally, image analysis techniques were used to calculate and analyze the quantity of stripped area in the asphalt mixtures. RESULTS : In general, the asphalt mixtures containing anti-stripping agents showed a higher resistance of anti-stripping based on the boiling water test and tensile strength ratio. CONCLUSIONS : The boiling water test can be used to differentiate the resistance of moisture susceptibility of asphalt mixtures, except for asphalt mixtures containing hydrated lime. The boiling water test can be used as a screening test for asphalt mixtures before conducting time consuming and expensive indirect tensile strength tests.

Evaluation of Reflection Cracking Resistance of Grid-Reinforced Asphalt Pavement Using Overlay Tester (Overlay Tester를 이용한 그리드 보강 아스팔트 포장의 반사균열 저항성 평가)

  • Yoo, Byung Soo;Seo, Woo Jin;Kim, Jo Soon;Park, Dae Wook
    • International Journal of Highway Engineering
    • /
    • v.18 no.1
    • /
    • pp.57-62
    • /
    • 2016
  • PURPOSES : Reflection cracking has been one of the major causes of distress when asphalt pavement is laid on top of concrete pavement. This study evaluated the reflection cracking resistance of asphalt mixtures reinforced with asphalt embedded glass fiber and carbon fiber using a Texas Transportation Institute (TTI) overlay tester. METHODS : Different asphalt mixtures such as polymer-modified mastic asphalt (PSMA) and a dense graded asphalt mixture were reinforced with asphalt-embedded carbon fiber and glass fiber. For comparison purposes, two PSMA asphalt mixtures and one dense graded asphalt mixture were evaluated without fiber reinforcement. Two different overlay test modes, the repeated overlay test (R-OT) and monotonic overlay test (M-OT), were used to evaluate the reflection cracking resistance of asphalt mixtures at $0^{\circ}C$. In the R-OT test, the number of repeated load when the specimen failed was obtained. In the M-OT test, the tensile strength at the peak load and tensile strain were obtained. RESULTS : As expected, the fiber-reinforced asphalt mixture showed a higher reflection cracking resistance than the conventional nonreinforced asphalt mixtures based on the R-OT test and M-OT test. The dense graded asphalt mixture showed the least reflection cracking resistance and less resistance than the PSMA. CONCLUSIONS : The TTI overlay tester could be used to differentiate the reflection cracking resistance values of asphalt mixtures. Based on the R-OT and M-OT results, the carbon-fiber-reinforced asphalt mixture showed the highest reflection cracking resistance among the nonreinforced asphalt mixtures and glass-fiber-reinforced asphalt mixture.

Evaluation of Physical and Mechanical Characteristics of Korean Epoxy Asphalt Mixtures (국산 에폭시 아스팔트 혼합물의 물리.역학적 특성 평가)

  • Kim, Byung-Hun;Baek, Jong-Eun;Lee, Hyun-Jong;Park, Hee-Mun
    • International Journal of Highway Engineering
    • /
    • v.14 no.1
    • /
    • pp.17-24
    • /
    • 2012
  • This study evaluated the performance of Korean epoxy asphalt mixtures using several laboratory tests. Four types of epoxy asphalt mixtures were manufactured based on 13mm dense graded asphalt mixtures: three Korean and one Japanese epoxy asphalt mixtures where 20% or 40% of asphalt binder was replaced by epoxy resins. Curing time was determined as 3 and 6 hours for the mixtures containing 40% and 20% of epoxy resins, respectively. From the laboratory tests including wheel tracking, indirect tension fatigue, bending beam, and moisture susceptibility tests, it was concluded that the epoxy asphalt mixtures had superior performance than conventional asphalt mixtures except moisture susceptibility. Also, the performance of the Korean epoxy asphalt mixtures was comparable to the Japanese mixtures. Thermal coefficient, bond strength, and indirect tension tests were conducted to examine the applicability of the Korean epoxy asphalt mixtures to concrete repair. Its adhesion was strong enough to be bonded to surrounding concrete materials and its tensile strength was comparable to the concrete, but thermal expansion coefficient was 5 times greater than the surrounding concrete.

A Study on Laboratory Performance Characteristics of Modified Asphalt Cements and Mixtures (다양한 개질 아스팔트 시멘트와 혼합물의 실험적 공용 특성 평가에 관한 연구)

  • Kim, Nak-seok;Im, Jung-Soon;Park, Hyun-SIk;Lee, Jong-Man
    • Journal of the Society of Disaster Information
    • /
    • v.3 no.1
    • /
    • pp.21-35
    • /
    • 2007
  • The principal objective of this research is to evaluate the laboratory mechanical characteristics of color asphalt binders and mixtures. The dynamic shear rheometer (DSR) tests were performed to analyze the viscous and elastic behavior of asphalt binders. Various tests were also conducted to investigate the laboratory performance characteristics of color asphalt mixtures. The test results revealed that the values of $G^*$ and ${\delta}$ of modified color binders were higher than those of the conventional binders at low temperatures. These results are expected to increase the thermal cracking resistance of asphalt mixtures at low temperatures. It should be noted that the color asphalt mixtures with modified asphalt binder can be widely used as a common pavement material with a proper mix design.

  • PDF

Evaluating Rutting Performance of High-Durability Asphalt Concrete Mixtures and Epoxy Used for Installation of High-Speed Weigh-In-Motion System (고속축중기 시스템의 도입을 위한 고기능 아스팔트 혼합물 및 에폭시의 내구성 평가)

  • Kwon, Hong Jun;Lee, Jong Sub;Kwon, Oh Sun;Kwon, Soon Min
    • International Journal of Highway Engineering
    • /
    • v.20 no.4
    • /
    • pp.7-13
    • /
    • 2018
  • PURPOSES : In order to apply high-speed weigh-in-motion (HS WIM) systems to asphalt pavement, three high-durability asphalt concrete mixtures installed with a WIM epoxy are evaluated. METHODS : In this study, dynamic stability, number of loading repetitions to reach the rut depth of 1 mm, and rut depth measurements of three asphalt mixtures at $60^{\circ}C$ were compared using an Asphalt Pavement Analyzer (APA). Laboratory-fabricated material and field core samples were prepared and tested according to KS F2374. RESULTS : Through the laboratory tests, it was found that all three modified asphalt mixtures (stone-mastic, porous, and semi-rigid) with WIM epoxy showed favorable permanent deformation results and passed the dynamic stability criterion of 3000 loading repetitions per 1 mm. In addition, it was confirmed that the modified SMA mixtures cored from the field construction yields satisfactory rutting testing results using the APA. Finally, the epoxy used for the HS WIM installation shows good adhesion with the three asphalt mixtures and permanent deformation resistance.

Evaluation of Warm Mix Asphalt Mixtures with Foaming Technology and Additives Using New Simple Performance Testing Equipment (새로운 Simple Performance Testing 장비를 이용한 중온형 폼드 아스팔트 혼합물의 공용성 평가)

  • Kim, Yong-Joo;Im, Soo-Hyok;Lee, David;Hwang, Sung-Do
    • International Journal of Highway Engineering
    • /
    • v.10 no.4
    • /
    • pp.19-29
    • /
    • 2008
  • To produce asphalt mixtures at temperature significantly below $135^{\circ}C$, called "Warm Mix Asphalt (WMA)", new technologies are currently being developed worldwide. To produce WMA mixtures in this research, foaming technology is adopted to effectively disperse asphalt binder at lower temperature than hot mix asphalt (HMA) in the field. The main objectives of this study are to develop WMA process using foaming technology (WMA-foam) and evaluate its performance characteristics under various temperatures and loading conditions. WMA-foam mixtures were produced by injecting PO 64-22 foamed asphalt into warm aggregates whereas WMA mixtures were produced by adding PO 64-22 asphalt (without foaming) in the warm aggregates. Both dynamic modulus and flow number of WMA-foam mixtures were higher than those of WMA mixtures. Based on the limited dynamic modulus and repeated load test results, it is concluded that the WMA-foam mixtures using warm aggregates at $100^{\circ}C$ are more resistant to fatigue cracking and rutting than WMA mixtures.

  • PDF

Performance Evaluation of High-RAP Asphalt Mixtures using Rapid-Setting Polymer-Modified Asphalt Emulsion (긴급보수용 개질 유화아스팔트 고비율 순환골재를 사용한 상온 아스팔트 혼합물의 성능 평가)

  • Kwon, Bong Ju;Heo, Jae Min;Han, Yong Jin;Rhee, Suk Keun
    • International Journal of Highway Engineering
    • /
    • v.17 no.2
    • /
    • pp.21-30
    • /
    • 2015
  • PURPOSES : The purpose of this study was to evaluate the performance of rapid-setting polymer-modified asphalt mixtures with a high reclaimed asphalt pavement (RAP) content. METHODS: A literature review revealed that emulsified asphalt is actively used for cold-recycled pavement. First, two types of rapid-setting polymer-modified asphalt emulsion were prepared for application to high-RAP material with no virgin material content. The quick-setting polymer-modified asphalt mixtures using two types of rapid-setting polymer-modified asphalt emulsion were subjected to the following tests: 1) Marshall stability test, 2) water immersion stability test and 3) indirect tensile strength ratio test. RESULTS AND CONCLUSIONS : Additional re-calibration of the RAP was needed for laboratory verification because the results of analyzing RAP aggregates, which were collected from different job sites, did not deviate from the normal range. The Marshall stability of each type of binder under dry conditions was good. However, the Type B mixtures with bio-additives performed better in the water immersion stability test. Moreover, the overall results of the indirect tensile strength test of RAP mixtures with Type B emulsions exceeded 0.7. Further research, consisting of lab testing and on-site application, will be performed to verify the possibility of using RAP for minimizing the closing of roadways.

Estimation of Air Voids in Asphalt Mixtures Using Ground-Penetrating Radar (지표투과레이더를 이용한 아스팔트 혼합물의 공극률 예측에 관한 연구)

  • Kim, Je Won;Kim, Yeon Tae;Kim, Booil;Park, Hee Mun
    • International Journal of Highway Engineering
    • /
    • v.18 no.4
    • /
    • pp.55-61
    • /
    • 2016
  • PURPOSES : The objective of this study was to determine the relationship between the dielectric characteristics of asphalt mixtures and the air voids present in them using ground penetrating radar (GPR) testing. METHODS : To measure the dielectric properties of the asphalt mixtures, the reflection coefficient method and the approach based on the actual thickness of the asphalt layer were used. An air-couple-type GPR antenna with a center frequency of 1 GHz was used to measure the time for reflection from the asphalt/base layer interface. A piece of aluminum foil was placed at the interface to be able to determine the reflection time of the GPR signal with accuracy. An asphalt pavement testbed was constructed, and asphalt mixtures with different compaction numbers were tested. After the GPR tests, the asphalt samples were cored and their thicknesses and number of air voids were measured in the laboratory. RESULTS : It was found the dielectric constant of asphalt mixtures tends to decrease with an increase in the number of air voids. The dielectric constant values estimated from the reflection coefficient method exhibited a slight correlation to the number of air voids. However, the dielectric constant values measured using the approach based on the actual asphalt layer thickness were closely related to the asphalt mixture density. Based on these results, a regression equation to determine the number of air voids in asphalt mixtures using the GPR test method was proposed. CONCLUSIONS : It was concluded that the number of air voids in an asphalt mixture can be calculated based on the dielectric constant of the mixture as determined by GPR testing. It was also found that the number of air voids was exponentially related to the dielectric constant, with the coefficient of determination, $R^2$, being 0.74. These results suggest that the dielectric constant as determined by GPR testing can be used to improve the construction quality and maintenance of asphalt pavements.

Remarks on the use of Electric Arc Furnace (EAF) Steel Slag in Asphalt Mixtures for Flexible Pavements (Electric Arc Furnace (EAF) Steel Slag의 아스팔트 포장 혼합물 내 대체 골재로서 적용 가능성에 대한 고찰)

  • Falchetto, Augusto Cannone;Moon, Ki Hoon
    • International Journal of Highway Engineering
    • /
    • v.17 no.1
    • /
    • pp.25-33
    • /
    • 2015
  • PURPOSES : This paper, presents the results of a laboratory study aimed to verify the suitability of a particular type of Electric Arc Furnace (EAF) steel slag to be recycled in the lithic skeleton of both dense graded and porous asphalt mixtures for flexible pavements. METHODS : Cyclic creep and stiffness modulus tests were performed to evaluate the mechanical performance of three different asphalt mixtures (dense graded, porous asphalt, and stone mastic) prepared with two types of EAF steel slag. For comparison purposes, the same three mixtures were also designed with conventional aggregates (basalt and limestone). RESULTS : All the asphalt mixtures prepared with EAF steel slag satisfied the current requirements of the European standards, which support EAF steel slag as a suitable material for flexible pavement construction. CONCLUSIONS : Based on the experimental work, the use of waste material obtained from steel production (e.g. EAF steel slag) as an alternative in the lithic skeleton of asphalt mixtures can be a satisfactory and reasonable choice that fulfills the "Zero Waste" objective that many iron and steel industries have pursued in the past decades.

A Study on the Physical Properties of Recycled Asphalt Mixtures Using Glass Fiber Reinforcement (유리섬유 보강재를 이용한 재활용 아스팔트 혼합물의 물리적 특성에 관한 연구)

  • Park, Ki Soo;Yoo, Pyeong Jun
    • International Journal of Highway Engineering
    • /
    • v.20 no.4
    • /
    • pp.27-34
    • /
    • 2018
  • PURPOSES : The objective of this study is to evaluate the physical properties of recycled asphalt mixtures reinforced with glass fiber. METHODS : Firstly, mixing design was conducted on recycled asphalt mixture for use of 50% recycled aggregate. Various laboratory tests were performed on four types of recycled asphalt mixtures with different glass fiber content to evaluate the physical properties. The laboratory tests include indirect tensile strength test, dynamic modulus test, Hamburg wheel tracking test and tensile-strength ratio to evaluate cracks, rutting and moisture resistance of mixtures. RESULTS : The indirect tensile strength of fiber reinforced glass increased about 139.4%. As a result of comparing the master curves obtained by the dynamic modulus test, the elasticity was low in the low temperature region and high in the high temperature region when the glass fiber was reinforced. The glass fiber contents of PEGS 0.3%, Micro PPGF 0.1% and Macro PPGF 0.3% showed the highest moisture resistance and rutting resistance. CONCLUSIONS : The test results show that use of glass fiber reinforcement can increase the resistance to cracking, rutting, and moisture damage of asphalt mixtures. It is also necessary to validate the long-term performance of recycled asphalt mixtures with glass fiber using full scale pavement testing and field trial construction.