• 제목/요약/키워드: artificial teeth

검색결과 234건 처리시간 0.034초

Detection of laser doppler blood flow signal from human teeth

  • Ikawa, M.;Iiyama, M.;Shimauchi, H.
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.546.1-546
    • /
    • 2003
  • Laser doppler flowmeter (LDF) has been applied to the measurement of pulpal blood flow (PBF) in human teeth. As far as we searched, the detection area of the pulp in the blood flow measurement has not been clarified, yet. Therefore, the purpose of this study was to obtain information of the detection area in PBF measurement using LDF. The experiments were performed on the artificial blood circulation in extracted human upper central incisors. The apical portions of examined teeth (n=6) were severed and root canals were enlarged from the apical end to the 2mm incisal to the level of enamel-cement junction. An individual resin cap of each tooth was prepared and a hole was drilled 2mm incisal to enamel-cement junction of the labial side of the cap. The measurement probe of LDF (MBF3D, Moor Instrument, UK) was plugged into the hole of the cap. Heparinized human peripheral blood, which was in advance collected and diluted 3 times with physiological saline, was pumped through the apical foramen of the teeth via a silicone tube and a disposable needle (o.d. 0.7mm) and blood flow signals were monitored. The flux signal significantly increased with the enlargement of the root canal to incisal direction (p<0.01, Friedman analysis). The result indicates that the performance of LDF in PBF with human teeth is limited.

  • PDF

수종의 인공 레진 치아의 마모저항성과 경도에 관한 비교 연구 (Comparative Study on Wear Resistance and Hardness of Several Artificial Resin Teeth)

  • 최유성;이준석;조인호
    • 구강회복응용과학지
    • /
    • 제24권2호
    • /
    • pp.129-146
    • /
    • 2008
  • 본 연구에서는 다양한 치과 수복재료에 대합되는 의치용 레진치의 마모저항성을 알아보기 위해 통상의 아크릴 릭 레진치인 $Trubyte^{(R)}$ $Biotone^{(R)}$ (Dentsply, U.S.A.)과 고강도 레진치인 Endura $Posterio^{(R)}$ (Shofu, Japan), Physio $Duracross^{(R)}$ (Nissin, Japan)를 수복재료인 금합금, 도재, 충전용 레진에 대합시켜 마모저항성을 비교 분석하였다. 또한 앞의 세 종류의 레진 인공치와 5종류의 의치세정제인 유한락스, 폴리덴트, 싸이덱스, 헥사메딘, 증류수를 사용하여 의치세정제 및 소독제가 경도에 미치는 영향을 비교 분석하여 다음과 같은 결과를 얻었다. 1. 대합되는 수복재료로 충전용 레진, 도재를 사용한 경우 $Trubyte^{(R)}$ $Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ 순으로 교두정 높이감소가 컸으며 세 재료간의 유의한 차이를 보였다 (p<0.05). 2. 대합되는 수복재료로 금합금을 사용한 경우 $Trubyte^{(R)}$ $Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ 순으로 교두정 높이 감소가 컸으며, 특히 $Trubyte^{(R)}$ $Biotone^{(R)}$ 이 다른 두 종류의 인공치보다 유의성 있게 높은 교두정 높이 감소를 보였다 (p<0.05). 3. 대합되는 수복재료로 충전용 레진, 금합금, 도재를 사용한 경우 모두 $Trubyte^{(R)}$ $Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ 순으로 무게 감소가 컸으며, 세 재료간의 유의한 차이를 보였다 (p<0.05). 4. 의치세정제에 따른 경도 감소는 실험 전과 후의 측정치를 비교했을 때 모든 레진 인공치에서 유의성 있는 차이 를 나타내었다 (p<0.05). 5. 유한락스, 싸이덱스, 헥사메딘에 담구었던 레진 인공치에 의한 경도감소는 $Trubyte^{(R)}$ $Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ 순으로 높은 감소를 보였고, 특히 $Trubyte^{(R)}$ $Biotone^{(R)}$이 다른 두 종류의 인공치보다 유의성 있게 높은 경도 감소를 보였다 (p<0.05). 이상의 실험 결과 마모저항성 실험에서는 최근에 개발된 Physio $Duracross^{(R)}$가 다른 두 종류의 레진 인공치에 비해 세 종류의 대합되는 수복재료 모두에서 높은 마모저항성을 보였고 특히 $Trubyte^{(R)}$ $Biotone^{(R)}$에 비해 유의성 있게 높은 마모저항성을 보였다. 경도 실험에서는 Physio $Duracross^{(R)}$와 Endura $Posterio^{(R)}$$Trubyte^{(R)}$ $Biotone^{(R)}$에 비해 유의성 있게 낮은 경도감소를 보였고 (p<0.05), 폴리덴트, 증류수에서는 유의한 차이를 보이지 않았다. 따라서, Physio $Duracross^{(R)}$가 세 종류의 레진 인공치에 비해 우수한 마모저항성을 보인다고 볼 수 있고, Endura $Posterio^{(R)}$와 함께 $Trubyte^{(R)}$ $Biotone^{(R)}$에 비해서 우수한 경도를 보인다고 볼 수 있지만, 단편적인 실험 결과이므로, 아직은 신중하게 고려되어야 하고, 더 많은 연구가 필요하다고 사료된다.

An esthetic appliance for the management of crown-root fracture: a case report

  • Jeon, Sang-Min;Lee, Kang-Hee;Jung, Bock-Young
    • Restorative Dentistry and Endodontics
    • /
    • 제39권3호
    • /
    • pp.226-229
    • /
    • 2014
  • Orthodontic extrusion is usually performed by means of a fixed orthodontic appliance that utilizes arch wire attached to adjacent teeth and transfers the desired force by elastic from the wire to the root. However, clinicians often encounter cases where the bonding required for tooth traction is not possible because the adjacent teeth have been restored with ceramic or veneer. The purpose of this case report is to describe a modified orthodontic extrusion appliance that is useful when conventional orthodontic treatment is not possible. The modified appliance was fabricated using an artificial tooth, clear plastic sheeting, and a braided fiber-reinforced composite strip that covered adjacent teeth without bonding. It satisfied the esthetic and functional needs of the patient and established the optimal biologic width.

의치주위조직(義齒周圍組織)의 기능인상(機能印象) 채득법에 의한 0$^{\circ}$ 구치(臼齒)의 Full Denture 제작법(製作法) ("A Study of Farbricating Full Denture, Which is Used Functional Imp and Zero-degree Artificial Poster Teeth")

  • 김의남
    • 대한치과기공학회지
    • /
    • 제7권1호
    • /
    • pp.33-40
    • /
    • 1985
  • When full denture is being fabricated, pronounciation, recovery of aesthetics of function and mastificatory function should be satisfies for patients. To satisfy for the function of denture, following is the difference between this new way of fabricating and formerly one of it. 1. The size of fabricating tooth which is harmony of original oral structure for patients is deaded by manufacturing labial index and artificial tongue. 2. By the use of artificial tongue and labial index, the arranges of artificial tooth is to become harmony of oral structure. 3. Formation of gingival decided functional impression which is used by impression paste, is harmony of oral structure. Therefore, this full denture can be satisfied with pronouncing oral function of recovery of aesthetics as well as mastificatory through physiological movement of oral tissue not disturbed with anything but cooperated drastically. In manufacturing of this full denture, both dentist and dental technician under cooperation need to proceed the work on the base of importance of communication.

  • PDF

의료용 폴리머 소재를 활용한 3D 프린팅 인공치아용 사면체 비정질 카본 코팅 기술 연구 (A Study on the Tetrahedral Amorphous Carbon (ta-C) Coating on Medical Polymer Materials for 3D Printing Artificial Teeth)

  • 장영준;김종국;신창희;유성미
    • Tribology and Lubricants
    • /
    • 제38권6호
    • /
    • pp.255-260
    • /
    • 2022
  • This research presents tetrahedral amorphous (ta-C) coating on the artificial tooth for improving the durability and functionality (esthtics, foreign body of tooth) by filtered cathodic vacuum arc (FCVA). A differentiated coating method is required for a ta-C coating on polymer owing to the low melting point of the polymer, inter-facial adhesion, low friction, and non-conductivity. Herein, ta-C coating is applied below 50℃, and the potential difference of the carbon plasma drawn to the substrate was controlled by applying a positive duct bias voltage without using a substrate bias voltage. Consequently, the ta-C coating with a thickness of 70nm using the duct bias condition of 20V with the highest plasma intensity satisfies the esthetics of the artificial tooth and had a 5B level of inter-facial adhesion. In addition, the composite hardness of ta-C/polymer is 380 MPa, and correlations with esthetics, sp3 bonding, and mechanical properties. The friction coefficient (CoF) of the ta-C coating in a water-lubricated environment is 0.07, showing a six-fold reduction in CoF compared with that of a polymer.

Automatic detection of periodontal compromised teeth in digital panoramic radiographs using faster regional convolutional neural networks

  • Thanathornwong, Bhornsawan;Suebnukarn, Siriwan
    • Imaging Science in Dentistry
    • /
    • 제50권2호
    • /
    • pp.169-174
    • /
    • 2020
  • Purpose: Periodontal disease causes tooth loss and is associated with cardiovascular diseases, diabetes, and rheumatoid arthritis. The present study proposes using a deep learning-based object detection method to identify periodontally compromised teeth on digital panoramic radiographs. A faster regional convolutional neural network (faster R-CNN) which is a state-of-the-art deep detection network, was adapted from the natural image domain using a small annotated clinical data- set. Materials and Methods: In total, 100 digital panoramic radiographs of periodontally compromised patients were retrospectively collected from our hospital's information system and augmented. The periodontally compromised teeth found in each image were annotated by experts in periodontology to obtain the ground truth. The Keras library, which is written in Python, was used to train and test the model on a single NVidia 1080Ti GPU. The faster R-CNN model used a pretrained ResNet architecture. Results: The average precision rate of 0.81 demonstrated that there was a significant region of overlap between the predicted regions and the ground truth. The average recall rate of 0.80 showed that the periodontally compromised teeth regions generated by the detection method excluded healthiest teeth areas. In addition, the model achieved a sensitivity of 0.84, a specificity of 0.88 and an F-measure of 0.81. Conclusion: The faster R-CNN trained on a limited amount of labeled imaging data performed satisfactorily in detecting periodontally compromised teeth. The application of a faster R-CNN to assist in the detection of periodontally compromised teeth may reduce diagnostic effort by saving assessment time and allowing automated screening documentation.

레진 인공치아의 재부착 방법에 따른 전단결합강도에 관한 연구 (A Study on the Shear Bond Strength of Resin Artificial Tooth Depending on Repair Techniques)

  • 김익중;이종혁;조인호
    • 구강회복응용과학지
    • /
    • 제21권2호
    • /
    • pp.143-151
    • /
    • 2005
  • The purpose of this study was to evaluate the most effective method for repairing the exfoliated resin teeth. The specimens were divided into five groups according to repair method and presence of retention holes. The groups were as follows Group1 : Control group Group2 : Sprinkle method with no retention holes Group3 : Sprinkle method with retention holes Group4 : Flask method with no retention holes Group5 : Flask method with retention holes The results were as follows. 1. According to shear bond strength, the value decreased in the order of group1, group5, group3, group2, group4 and there were significant difference between, each group except between group1 and groups5, group2 and group3, group2 and group4(p < 0.05). 2. According to observations of the exfoliation surface, group2 and 4 showed more failure in the denture base resin and repair resin interface, but in group1, 3 and 5 there were more mixed failures. From the results above, there were no significant difference between repair methods without retention holes. But when comparing groups with retention holes, the flask method showed significantly improved results compared to the sprinkle method. Especially, group5 showed similar results as the control group.

Shear bond strength between CAD/CAM denture base resin and denture artificial teeth when bonded with resin cement

  • Han, Sang Yeon;Moon, Yun-Hee;Lee, Jonghyuk
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권5호
    • /
    • pp.251-258
    • /
    • 2020
  • PURPOSE. The bond strengths between resin denture teeth with various compositions and denture base resins including conventional and CAD/CAM purposed materials were evaluated to find influence of each material. MATERIALS AND METHODS. Cylindrical rods (6.0 mm diameter × 8.0 mm length) prepared from pre-polymerized CAD/CAM denture base resin blocks (PMMA Block-pink; Huge Dental Material, Vipi Block-Pink; Vipi Industria) were bonded to the basal surface of resin teeth from three different companies (VITA MFT®; VITA Zahnfabrik, Endura Posterio®; SHOFU Dental, Duracross Physio®; Nissin Dental Products Inc.) using resin cement (Super-Bond C&B; SUN MEDICAL). As a control group, rods from a conventional heat-polymerizing denture base resin (Vertex™ Rapid Simplified; Vertex-Dental B.V. Co.) were attached to the resin teeth using the conventional flasking and curing method. Furthermore, the effect of air abrasion was studied with the highly cross-linked resin teeth (VITA MFT®) groups. The shear bond strengths were measured, and then the fractured surfaces were examined to analyze the mode of failure. RESULTS. The shear bond strengths of the conventional heat-polymerizing PMMA denture resin group and the CAD/CAM denture base resin groups were similar. Air abrasion to VITA MFT® did not improve shear bond strengths. Interfacial failure was the dominant cause of failure for all specimens. CONCLUSION. Shear bond strengths of CAD/CAM denture base materials and resin denture teeth using resin cement are comparable to those of conventional methods.

3차원 적층 출력과 밀링에 의해 제작된 일체형 의치의 인공치 변위 평가 (Artificial teeth displacement of monolithic complete denture manufactured by 3D printer and milling machine)

  • 곽영훈;이세한;이경제;김희중
    • 대한치과보철학회지
    • /
    • 제55권4호
    • /
    • pp.394-402
    • /
    • 2017
  • 목적: 의치상과 인공치가 밀링과 3차원 프린팅 방식에 의해 일체형으로 제작될 때 각기 인공치의 변위를 평가하고자 한다. 재료 및 방법: 밀링과 3차원 프린팅 방식으로 상하악 각기 12개의 의치를 제작하였다. 프린팅에 의해 제작된 상악의치 군은 Group Up이고, 하악의치군은 Group Lp이다. 밀링에 의해 제작된 상악의치 군은 Group Um이고, 하악의치 군은 Group Lm이다. 대조군 상악의치는 소프트웨어상에서 최종적으로 디자인된 것으로 상악은 Group Uc이고 하악은 Group Lc이다. 상하악 의치의 양중절치 사이(AB, ab), 양견치 사이(CD, cd), 양제1대구치 사이(EF, ef), 중절치와 제1대구치사이(AE, ae) 및 중절치와 설측점사이(AG, ag) 의 거리를 측정하였다. 결과: AG와 ag는 상하악 의치 모두에서 프린트된 의치군과 컨트롤 의치군 사이에서 뿐 만 아니라 밀링 의치군과 컨트롤 의치군 사이에서도 통계학적 유의성을 나타내었다(One-way ANOVA, P < .05). 하악 일체형의치에서는 Group Lp와 Group Lm 사이에 ab, cd, ef 모두 통계학적 유의성을 나타내었다. 결론: 밀링과 3차원 프린팅에 의해 제작된 의치의 인공치 변위는 통계학적 유의성이 나타났으나, 임상적으로 매우 양호한 변위량을 보여주었다.