DOI QR코드

DOI QR Code

Artificial teeth displacement of monolithic complete denture manufactured by 3D printer and milling machine

3차원 적층 출력과 밀링에 의해 제작된 일체형 의치의 인공치 변위 평가

  • Kwak, Young-Hun (Department of Prosthodontics, College of Dentistry, Chosun University) ;
  • Lee, Sea-Han (Department of Prosthodontics, College of Dentistry, Chosun University) ;
  • Lee, Gyeong-Je (Department of Prosthodontics, College of Dentistry, Chosun University) ;
  • Kim, Hee-Jung (Department of Prosthodontics, College of Dentistry, Chosun University)
  • 곽영훈 (조선대학교 치과대학 치과보철학교실) ;
  • 이세한 (조선대학교 치과대학 치과보철학교실) ;
  • 이경제 (조선대학교 치과대학 치과보철학교실) ;
  • 김희중 (조선대학교 치과대학 치과보철학교실)
  • Received : 2017.07.17
  • Accepted : 2017.10.13
  • Published : 2017.10.31

Abstract

Purpose: The purpose of this study is to evaluate the displacement of artificial tooth of monolithic complete denture manufactured by milling and 3D printing method in which the denture base and the artificial teeth are simultaneously made. Materials and methods: Twelve upper and lower complete dentures for each were made by milling and 3D printing method. Group Up and Group Lp are a group of upper and lower dentures made by printing, and Group Um and Group Lm are denture groups made by milling. Group Uc and Group Lc are is a group of finally designed upper and lower dentures respectively. Measurements were performed between both central incisors (AB, ab), both canines (CD, cd), both first molars (EF, ef), between an incisor and a first molar (AE, ae), and between incisor and lingual point (AG, ag) for each upper and lower denture. Results: AG and ag value between printed dentures and original ones as well as between milled dentures and original ones showed a statistically significant difference (One-way ANOVA, P<.05) in both lower and upper monolithic dentures. In the lower monolithic ones, ab, cd and ef value revealed a significant difference between Group Lp and Group Lm (One-way ANOVA, P<.05). Conclusion: Dentures made using milling or 3D printers revealed statistically significant difference compared with those of original data. However, it showed clinically very accurate reproducibility.

목적: 의치상과 인공치가 밀링과 3차원 프린팅 방식에 의해 일체형으로 제작될 때 각기 인공치의 변위를 평가하고자 한다. 재료 및 방법: 밀링과 3차원 프린팅 방식으로 상하악 각기 12개의 의치를 제작하였다. 프린팅에 의해 제작된 상악의치 군은 Group Up이고, 하악의치군은 Group Lp이다. 밀링에 의해 제작된 상악의치 군은 Group Um이고, 하악의치 군은 Group Lm이다. 대조군 상악의치는 소프트웨어상에서 최종적으로 디자인된 것으로 상악은 Group Uc이고 하악은 Group Lc이다. 상하악 의치의 양중절치 사이(AB, ab), 양견치 사이(CD, cd), 양제1대구치 사이(EF, ef), 중절치와 제1대구치사이(AE, ae) 및 중절치와 설측점사이(AG, ag) 의 거리를 측정하였다. 결과: AG와 ag는 상하악 의치 모두에서 프린트된 의치군과 컨트롤 의치군 사이에서 뿐 만 아니라 밀링 의치군과 컨트롤 의치군 사이에서도 통계학적 유의성을 나타내었다(One-way ANOVA, P < .05). 하악 일체형의치에서는 Group Lp와 Group Lm 사이에 ab, cd, ef 모두 통계학적 유의성을 나타내었다. 결론: 밀링과 3차원 프린팅에 의해 제작된 의치의 인공치 변위는 통계학적 유의성이 나타났으나, 임상적으로 매우 양호한 변위량을 보여주었다.

Keywords

References

  1. Dubojska AM, White GE, Pasiek S. The importance of occlusal balance in the control of complete dentures. Quintessence Int 1998;29:389-94.
  2. Wong DM, Cheng LY, Chow TW, Clark RK. Effect of processing method on the dimensional accuracy and water sorption of acrylic resin dentures. J Prosthet Dent 1999;81:300-4. https://doi.org/10.1016/S0022-3913(99)70273-8
  3. Teraoka F, Takahashi J. Controlled polymerization system for fabricating precise dentures. J Prosthet Dent 2000;83:514-20. https://doi.org/10.1016/S0022-3913(00)70007-2
  4. Peyton FA. History of resins in dentistry. Dent Clin North Am 1975;19:211-22.
  5. Murray MD, Darvell BW. The evolution of the complete denture base. Theories of complete denture retention-a review. Part 1. Aust Dent J 1993;38:216-9. https://doi.org/10.1111/j.1834-7819.1993.tb03067.x
  6. Kimoto S, Kobayashi N, Kobayashi K, Kawara M. Effect of bench cooling on the dimensional accuracy of heat-cured acrylic denture base material. J Dent 2005;33:57-63. https://doi.org/10.1016/j.jdent.2004.08.002
  7. Consani RL, Mesquita MF, Sobrinho LC, Sinhoreti MA. Dimensional accuracy of upper complete denture bases: the effect of metallic flask closure methods. Gerodontology 2009;26:58-64. https://doi.org/10.1111/j.1741-2358.2008.00234.x
  8. Skinner EW, Cooper EN. Physical properties of denture resins: part I: curing shrinkage and water sorption. J Am Dent Assoc 1943;30:1845-52. https://doi.org/10.14219/jada.archive.1943.0394
  9. Elahi JM, Abdullah MA. Effect of different polymerization techniques on dimensional stability of record bases. J Prosthet Dent 1994;71:150-3. https://doi.org/10.1016/0022-3913(94)90023-X
  10. Negreiros WA, Consani RL, Mesquita MF, Sinhoreti MA, Faria IR. Effect of flask closure method and post-pressing time on the displacement of maxillary denture teeth. Open Dent J 2009;3:21-5. https://doi.org/10.2174/1874210600903010021
  11. Rizzatti-Barbosa CM, Machado C, Joia FA, dos Santos Sousa RL. A method to reduce tooth movement of complete dentures during microwave irradiation processing. J Prosthet Dent 2005;94:301-2. https://doi.org/10.1016/j.prosdent.2005.05.008
  12. Badel T, Panduric J, Kraljevic S, Dulcic N. Checking the occlusal relationships of complete dentures via a remount procedure. Int J Periodontics Restorative Dent 2007;27:181-92.
  13. Bidra AS, Taylor TD, Agar JR. Computer-aided technology for fabricating complete dentures: systematic review of historical background, current status, and future perspectives. J Prosthet Dent 2013;109:361-6. https://doi.org/10.1016/S0022-3913(13)60318-2
  14. Goodacre CJ, Garbacea A, Naylor WP, Daher T, Marchack CB, Lowry J. CAD/CAM fabricated complete dentures: concepts and clinical methods of obtaining required morphological data. J Prosthet Dent 2012;107:34-46. https://doi.org/10.1016/S0022-3913(12)60015-8
  15. Infante L, Yilmaz B, McGlumphy E, Finger I. Fabricating complete dentures with CAD/CAM technology. J Prosthet Dent 2014;111:351-5. https://doi.org/10.1016/j.prosdent.2013.10.014
  16. Kattadiyil MT, Goodacre CJ, Baba NZ. CAD/CAM complete dentures: a review of two commercial fabrication systems. J Calif Dent Assoc 2013;41:407-16.
  17. Kanazawa M, Inokoshi M, Minakuchi S, Ohbayashi N. Trial of a CAD/CAM system for fabricating complete dentures. Dent Mater J 2011;30:93-6. https://doi.org/10.4012/dmj.2010-112
  18. Inokoshi M, Kanazawa M, Minakuchi S. Evaluation of a complete denture trial method applying rapid prototyping. Dent Mater J 2012;31:40-6. https://doi.org/10.4012/dmj.2011-113
  19. Baba NZ, AlRumaih HS, Goodacre BJ, Goodacre CJ. Current techniques in CAD/CAM denture fabrication. Gen Dent 2016;64:23-8.
  20. Wimmer T, Gallus K, Eichberger M, Stawarczyk B. Complete denture fabrication supported by CAD/CAM. J Prosthet Dent 2016;115:541-6. https://doi.org/10.1016/j.prosdent.2015.10.016
  21. Yamamoto S, Kanazawa M, Iwaki M, Jokanovic A, Minakuchi S. Effects of offset values for artificial teeth positions in CAD/CAM complete denture. Comput Biol Med 2014;52:1-7.
  22. Yamamoto S, Kanazawa M, Hirayama D, Nakamura T, Arakida T, Minakuchi S. In vitro evaluation of basal shapes and offset values of artificial teeth for CAD/CAM complete dentures. Comput Biol Med 2016;68:84-9. https://doi.org/10.1016/j.compbiomed.2015.11.004
  23. Sayed ME, Swaid SM, Porwal A. Effect of cast modification on linear dimensional change of acrylic tooth position following maxillary complete denture processing. J Prosthodont 2016 Feb 16.
  24. Shibayama R, Gennari Filho H, Mazaro JV, Vedovatto E, Assuncao WG. Effect of flasking and polymerization techniques on tooth movement in complete denture processing. J Prosthodont 2009;18:259-64. https://doi.org/10.1111/j.1532-849X.2008.00421.x
  25. Salloum AM. Effect of three investing materials on tooth movement during flasking procedure for complete denture construction. Saudi Dent J 2016;28:56-61. https://doi.org/10.1016/j.sdentj.2015.08.003
  26. Kishi M. Experimental studies on the relation between area and displacement of loading surfaces in connection with displaceability in the mucosa of edentulous alveolar ridge under pressure. Shikwa Gakuho 1972;72:17-45.
  27. Park C, Kim MH, Hong SM, Go JS, Shin BS. A study on the comparison mechanical properties of 3D printing prototypes with laminating direction. J Korean Soc Manufactur Technol Eng 2015;24:334-41. https://doi.org/10.7735/ksmte.2015.24.3.334
  28. Objet Eden 260VS. Stratasys Ltd., Available at: http://www.stratasys.com