Comparison of removal torques of SLActive® implant and blasted, laser-treated titanium implant in rabbit tibia bone healed with concentrated growth factor application

  • Park, Sang-Hun;Park, Kyung-Soon;Cho, Sung-Am
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권2호
    • /
    • pp.110-115
    • /
    • 2016
  • PURPOSE. The purpose of this study was to compare the removal torques of a chemically modified SLActive implant and a blasted, laser-treated (BLT) implant, which were soaked in saline for 2 weeks after their surface modifications. The removal torques of the two implants were measured 4 weeks after their implantation into the bone defect area in rabbit tibias with concentrated growth factor (CGF) application. MATERIALS AND METHODS. To make artificial bone defects in the cortical layers of both tibias, an 8-mm diameter trephine bur was used. Then, prepared CGF was applied to the bony defect of the left tibia, and the bony defect of the right tibia was left unfilled. Four weeks later, the surgical sites of 16 rabbits were re-exposed. For 8 rabbits, the SLActive implants (Straumann, Switzerland) were inserted in the left tibia, and the BLT implants (CSM implant, Daegu, Korea) were inserted in the right tibia. For other rabbits, the BLT implants were inserted in the left tibia, and the SLActive implants were inserted in the right. Four weeks afger the insertion, torque removal was measured from 4 rabbits exterminated via $CO_2$ inhalation. RESULTS. No significant difference was observed between removal torques of the BLT implant and the SLActive implant (P>.05). CONCLUSION. It was found that BLT surface modification exhibited excellent osseointegration. In addition, CGF application did not affect the insertion and removal torque of the implants.

Effects of recycling on the biomechanical characteristics of retrieved orthodontic miniscrews

  • Yun, Soon-Dong;Choi, Sung-Hwan;Cha, Jung-Yul;Yu, Hyung-Seog;Kim, Kwang-Mahn;Kim, Jin;Hwang, Chung-Ju
    • 대한치과교정학회지
    • /
    • 제47권4호
    • /
    • pp.238-247
    • /
    • 2017
  • Objective: The aim of this study was to compare recycled and unused orthodontic miniscrews to determine the feasibility of reuse. The comparisons included both miniscrews with machined surfaces (MS), and those with etched surfaces (ES). Methods: Retrieved MS and ES were further divided into three subgroups according to the assigned recycling procedure: group A, air-water spray; group B, mechanical cleaning; and group C, mechanical and chemical cleaning. Unused screws were used as controls. Scanning electron microscopy, energy-dispersive X-ray spectrometry, insertion time and maximum insertion torque measurements in artificial bone, and biological responses in the form of periotest values (PTV), bone-implant contact ratio (BIC), and bone volume ratio (BV) were assessed. Results: Morphological changes after recycling mainly occurred at the screw tip, and the cortical bone penetration success rate of recycled screws was lower than that of unused screws. Retrieved ES needed more thorough cleaning than retrieved MS to produce a surface composition similar to that of unused screws. There were no significant differences in PTV or BIC between recycled and unused screws, while the BV of the former was significantly lower than that of the latter (p < 0.05). Conclusions: These results indicate that reuse of recycled orthodontic miniscrews may not be feasible from the biomechanical aspect.

실험적 골파괴와 골형성에 대한 방사선학적 연구 (RADIOLOGIC STUDY OF THE EXPERIMENTALLY PRODUCED BONE DESTRUCTION AND BONE FORMATION)

  • 최순철;안형규
    • 치과방사선
    • /
    • 제18권1호
    • /
    • pp.13-25
    • /
    • 1988
  • Bone destruction was induced experimentally by the insertion of a bit of the arsenic compound into the pulp chambers of the right premolars and the artificial bone defects were produced in the periapical regions of the left premolars in 7 dogs. The serial standardized periapical radiographs using aluminum stepwedge attached to the XCP instruments, and resin bite blocks were taken following insertion of arsenic compound and at 2, 4, 7, 10, 14, 17, 21, 24 and 28 days in case of bone destruction and following bone injury and weekly thereafter for a total of 14 weeks in case of bone formation. The errors of the method were determined with error estimators described by the Duinkerke. All radiographs were evaluated by the visual examination after joint evaluation by three dental radiologists and analysed with densitometer. The following results were obtained; 1. Analysis of the bone destruction process 1) The error of the method in estimating two distances proved to be small (S.D. for the measuring error; 0.04㎜, S.D. for the over-all error; 0.06㎜, S.D. for the positioning error; 0.05㎜) 2) The radiographic changes were observed after 7 days in 6 cases, 4 days in 1 case and 10 days in 1 case by the visual examination. 3) Aluminum equivalent values were diminished after 2 days and the diminution of 0.58±0.19㎜ was demanded to be detected by the visual examination. 2. Analysis of the bone formation process 1) The error of the method in estimating two distances proved to be small (S.D. for the measuring error; 0.03㎜, S.D. for the over-all error; 0.04㎜ S.D. for the positioning error; 0.04㎜) 2) The radiographic changes were observed after 2 weeks in 5 cases and 3 weeks in 2 cases by the visual examination. 3) Aluminum equivalent values were increased after 1 week and the increase of 0.45±0.15㎜ was demanded to be detected by the visual examination. 4) Aluminum equivalent values were increased continuously for 7 or 9 weeks but there as only extremely small change after 10 weeks.

  • PDF

The reliability of Anycheck device related to healing abutment diameter

  • Lee, Dong-Hoon;Shin, Yo-Han;Park, Jin-Hong;Shim, Ji-Suk;Shin, Sang-Wan;Lee, Jeong-Yol
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권2호
    • /
    • pp.83-88
    • /
    • 2020
  • PURPOSE. The purpose of this in vitro study was to examine the reliability of the Anycheck device and the effect of the healing abutment diameter on the Anycheck values (implant stability test, IST). MATERIALS AND METHODS. Thirty implants were placed into three artificial bone blocks with 10 Ncm, 15 Ncm, and 35 Ncm insertion torque value (ITV), respectively (n = 10). (1) The implant stability was measured with three different kinds of devices (Periotest M, Osstell ISQ Mentor, and Anycheck). (2) Five different diameters (4.0, 4.5, 4.8, 5.5, and 6.0 mm) of healing abutments of the same height were connected to the implants and the implant stability was measured four times in different directions with Anycheck. The measured mean values were statistically analyzed. RESULTS. The correlation coefficient between the mean implant stability quotient (ISQ) and IST value was 0.981 (P<.01) and the correlation coefficient between the meant periotest value (PTV) and IST value was -0.931 (P<.01). There were no statistically significant differences among the IST values with different healing abutment diameters. CONCLUSION. There was a strong correlation between the Periotest M and Anycheck values and between the ISQ and IST. The diameter of the healing abutment had no effect on the Anycheck values.

우수 한우의 수정란 생산 및 이식 (Embryo Production in Superior Hanwoo Donors and Embryo Transfer)

  • 손동수;한만희;최창용;최선호;조상래;김현종;류일선;최성복;이승수;김영근;김삼기;김상희;신권희
    • 한국수정란이식학회지
    • /
    • 제21권2호
    • /
    • pp.147-156
    • /
    • 2006
  • 본 연구는 MOET 기법에 의해 우수한 한우로부터 다수의 수정란을 회수하여 농가의 소에 이식하므로서 우수한 유전 자원을 확산시키고자 실시하였다. 80두의 우수 한우 공란우를 선발하여, 발정 확인 후 황체기에 성선 자극 호르몬($Folltropin^(R)-V$)을 투여하는 기존의 과배란 처리법과 임의의 발정주기에 CIDR를 삽입하고 성선 자극 호르몬을 투여하는 새로운 과배란 처리법에 의한 수정란 생산 비교와 CIDR 삽입한 한우 공란우에서 성선 자극 호르몬 ($Antorin^(R)R10$)의 투여 용량의 차이 (36 mg vs 28 mg) 에 따른 수정란 생산 성적을 비교하였다. 한편, 우수 공란우로부터 채란된 신선 수정란 또는 동결-융해 수정란을 농가 수란우 226두에 이식하였으며, 이식 결과 수태율에 대한 수정란 상태(신선 vs 동결-융해), 년도, 이식 시술자, 계절, 농가에 대한 영향을 조사하였다. 한우 공란우에서 기존의 과배란 처리 방법에 비해서 발정의 확인없이 CIDR를 삽입 후 과배란 처리 방법이 보다 많은 총회수 난자(6.5 vs. 5.8)와 이식 가능 수정란(3.9 vs.3.2)을 회수하였다(p<0.01). CIDR 처리 한우 공란우에서 성선 자극 호르몬($Antorin^(R)R10$) 용량을 36 mg으로 처리시가 28 mg 처리시 보다 많은 이식 가능 수정란(8.3 vs. 5.4)을 회수하였다(p<0.05). 수정란 이식후 수태율은 수정란의 상태(신선 43.9% vs 동결-융해 23.1%) 및 이식 시술자 (53.9 vs. $0{\sim}16.7%$)가 특히 중요한 영향을 미치는 것으로 나타났다(p<0.01). 본 연구의 결과는 CIDR를 이용한 과배란 처리 방법은 우수한 한우 수정란의 생산에 효과적으로 이용될 수 있음을 보여 주었으며, 수정란의 농가 수란우에 대한 이식은 동결-융해 수정란의 수태율 증진 및 이식 시술자의 기술이 향상될 때보다 효과적으로 이루어질 수 있을 것으로 보인다.

일측성 구순열비변형에서 다공성 폴리에틸렌 판을 이용한 상악골이상구증대술 (Augmentation of Pyriform Margin Using Porous High-Density Polyethylene Sheet In Unilateral Cleft Lip Nasal Deformity)

  • 한기환;김진한;최태현;김준형;손대구
    • Archives of Plastic Surgery
    • /
    • 제35권4호
    • /
    • pp.431-438
    • /
    • 2008
  • Purpose: The common deformity after the correction of unilateral cleft lip nasal deformity is nasal asymmetry, and it is caused by the hypoplasia of the pyriform aperture. To correct this, many procedures have been applied, but still many problems are present. Authors performed the inlay and onlay insertion of porous high density polyethylene sheet(1 mm thickness $Medpor{(R)}$ sheet) in the hypoplastic pyriform margin of cleft side and obtained satisfactory results. Methods: 11 cases were performed and the mean follow up period was 15.1 months. Their mean age was 23.6 years. Under general anesthesia, bilateral pyriform margin was exposed. $Medpor{(R)}$ sheets in "match stick" like shaped were inlay inserted, and kidney shaped were onlay inserted fixating with two 6 mm titanium screws. After the surgery, the results was evaluated by photogrammetric analysis. On the basal view, the distance from the subalare and labiale superius' to the transverse baseline connecting the both cheilions was measured from the cleft side and the non-cleft side. Then, the postoperative symmetry was assessed by obtaining the cleft side against the non-cleft side as proportion index, defined as lateral and medial upper lip contour index. Results: There were 2 infections. The cause was because the inserted implant was too long and thus protruded to the base of nasal cavity. The lateral upper lip contour index was from 95.49 to 103.27, and medial upper lip contour index was from 90.92 to 100.49, it was statistically increased, and thus the symmetry was improved. However clinically mild depression remained at nostril floor. Conclusion: Authors performed porous high density polyethylene sheet inlay and onlay insertion for the hypoplasia of the pyriform margin in unilateral cleft lip nasal deformity. It was found that depressed pyriform margin and upper lip were corrected effectively except for the nostril floor, for which an additional soft tissue augmentation would be necessary. The inlay insertion has risk of protrusion, thus the guideline of the use of artificial prosthesis should be observed strictly.

여성에서 남성으로의 성전환증에서 음낭성형술의 필요성과 방법 (The necessary & method of scrotoplasty in female to male transgender)

  • 김석권;문인선;권용석;이근철
    • Archives of Plastic Surgery
    • /
    • 제36권4호
    • /
    • pp.437-444
    • /
    • 2009
  • Purpose: Transgender is a disorder of gender identity, who have appropriate chromosomal, hormonal and anatomical characteristics corresponding to their sexual phenotype but feel strongly with respect to their sexual identity, that they belong to the opposite sex. There is a persistence discomfort and sense of inappropriateness about one's assigned sex in a person who has reached puberty. Transgender is a psychiatric problem, but surgical method provides more satisfactory adjustment for patients. In gender reassignment surgery for female to male transgender, mastectomy, nipple reduction, hysterectomy, oophorectomy and phalloplasty are included. And as the final operation, recommended for scrotoplasty and artificial testes insertion. So we investigated the necessity and method of scrotoplasty in the final operation of female to male transgender. Method: The authors have long term follow-up of 75 cases female to male transgender during January, 1991 to February, 2008. Among them, 13 cases were evaluated in this study. During phalloplasty, the labium major skin preserved. And this labium majoral skin flap was made for the neoscrotum. At least six months later, artificial testes were inserted in neoscrotum with local anesthesia. Middle sized (3 cm diameter) artificial testes(silicon gel or carving soft silicone implant) were used because of the limitation of the neoscrotum. We evaluated the questionnaire and interview about the postoperative satisfaction in configuration of reconstructed scrotum, and the necessity of operation, the postoperative psychosocioeconomic improvement and limitation of body exposure activities such as swimming, public bathing. Results: Based on this study, satisfaction of reconstructed scrotum after scrotoplasty was improved(92%). The necessity of scrotoplasty was in 92.3% and the postoperative psychosocioeconomic well - being improvement was 77% in answers. Less limitation of activities requiring body exposure was 54% in answers. Most of the patients were satisfied with the results of surgical operation inspite of the operative procedure had some postoperative complications. Conclusion: This study was reported that the scrotoplasty in female to male transgender is not only a conversion of external genitalia but also an improvement of psychosocial state. Most patients sincerely hope to this operation, so we improve our surgical method for more good results.

고밀도 인공물 환자에서 반복적 재구성 사용 유무에 따른 3차원 입체조형 방사선 치료 계획 인자의 정량분석 (Quantitative Analysis of 3D-CRT Radiotherapy Planning Factors with or without IR in Patients with High Density Artifacts)

  • 이규욱;최우형;정예현;이주희;윤인하;허영철
    • 한국방사선학회논문지
    • /
    • 제14권1호
    • /
    • pp.7-14
    • /
    • 2020
  • 본 연구의 목적은 3차원 입체조형 방사선 치료 계획에 고밀도 인공 물체를 삽입하는 불확실성을 보정하기 위해 반복적 재구성(IR)의 유용성을 평가하는 것이다. 쇠구슬 팬텀과 티타늄이 삽입된 대상자의 CT Simulation 영상에서 IR을 적용한 영상과 IR을 적용하지 않은 영상을 얻었으며 선량 평가 인자인 HI, MU와 체적 평가 인자인 Volume과 PCI를 비교하였다. 쇠구슬과 티타늄 팬텀 실험 결과 IR을 적용할 때 고밀도 인공물질의 부피가 각각 4.850%, 11.456% 줄었으며 MU는 0.924%, 1.181% 감소하였다. HI는 0.106%, 0.272% 감소하였고 PCI는 0.358%, 0.867% 감소하였다. IR을 척추 성형술, 대퇴부 정렬핀, 손목 정렬핀 등 대상자의 CT 영상에 적용했을 때 인공물의 부피는 47.76%, 23.841%, 49.339% 감소하였다. MU도 0.924%, 0.294%, 1.675%, HI는 1.232%, 0.412%, 1.695% 감소하였으며 PCI는 4.022%, 0.512%, 13.472% 감소하였다. 결론적으로 3차원 입체조형 방사선 치료 계획시 IR을 적용했을 때 고밀도 인공물이 삽입된 팬텀과 대상자 케이스에서 선량과 체적이 모두 감소되었다는 것을 확인할 수 있었다.

젖소에서 CIDR 투여에 의한 발정 유도 후 수태율과 다른 인자와의 관계 (Relationship between the Conception Rate after Estrus Induction using CIDR and Other Parameters in Dairy Cows)

  • 박철호;손창호
    • 한국수정란이식학회지
    • /
    • 제26권1호
    • /
    • pp.1-7
    • /
    • 2011
  • The purpose of this study was to determine the relationship between conception rate and other parameters (body condition score; BCS, progesterone concentrations and follicle size) before estrus induction with CIDR(intravaginal progesterone-releasing controlled internal drug release). The conception rate in cows with < 2.75, 2.75 to 3.25, and 3.25 <, BCS regardless of AI (artificial insemination) time was 46.6%, 63.3%, and 46.6% at CIDR insertion, respectively. The conception rate regardless of BCS was 54.9% in cows inseminated based on detected estrus, and 48.7% in cows inseminated at 72 to 80 hours (timed artificial insemination, TAI) after removal of CIDR. The conception rate regardless of AI time was 40.0% in cows with low progesterone concentrations (less than 1.0 ng/ml), and 56.6% in cows with high progesterone concentrations (more than 1.0 ng/ml) at CIDR injection. The conception rate regardless of progesterone concentrations was 53.8% in cows inseminated based on detected estrus, and 38.0% in cows of TAI after removal of CIDR. The conception rate regardless of AI time was 43.3% in cows with small follicle (less than 5 mm), 53.3% in cows between 5 mm to 10 mm of follicle, and 63.3% in cows with large folliclc (more than 10 mm) at CIDR injection, respectively. The conception rate regardless of follicle size was 58.4% in cows inseminated based on detected estrus, and 45.9% in cows of TAI after removal of CIDR. These results indicated that if the cows with BCS 2.75 to 3.25, active corpus luteum, and/or large dominant follicle (more than 10 mm) are used for estrus induction, the conception rate will be greater.

호흡신호 무선 통신 시스템 개발 (The Wireless Monitoring System of Respiration Signal)

  • 손병희;장종찬;양효식;차은종
    • 융합신호처리학회논문지
    • /
    • 제12권3호
    • /
    • pp.157-162
    • /
    • 2011
  • 본 연구는 심폐소생술 (CPR) 중 인공호흡의 무선 전송 시스템 구현에 관한 것으로, 병원 전 단계에서의 CPR 성과를 높임으로써 응급환자의 생존율을 높이기 위한 환자-병원간 무선 통신 시스템이다. 기도삽관 기반 호흡기류센서를 적용하여 호흡량을 측정하였는데, 기도삽관을 통한 인공호흡은 기류량의 손실을 최소화하여 보다 정확한 흡기-호기량 계측이 가능하고, 기도-식도 구분을 통해 식도팽창을 방지하여 다른 인공호흡 방법에 비해 장점을 입증하였다. 또, 인공호흡 주요지표인 분당 평균호흡량 (V), 호기말 이산화탄소 농도 ($EtCO_2$), 기도압력 (Ptr)을 디지털화하여 정의하였으며 정의된 데이터를 무선 통신 시스템을 이용하여 전송망의 대역폭 및 지연시간을 확인하였다. 호흡신호를 전송하기 위해 필요한 최대대역폭 (815 Kbps) 에 비해 Wireless LAN의 대역폭 (54 Mbps) 이 충분하여 네트워크 부하는 1.5 % 미만이었으며, 전송지연시간은 0.3 초 이내로 측정되었다.