아크고장 및 CT포화가 거리계전 알고리즘에 미치는 영향분석 (Analysis on the Effect of Arcing Fault and CT Saturation on Distance Algorithms)

  • 손천명;강상희;강용철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.50-52
    • /
    • 2002
  • Distance relays need accurate current and voltage for determining the trip ignition. Therefore we must analyze nonlinear phenomena which cause distortion in signals first of all. This paper presents the effect of some distortion(arcing fault and current transformer saturation) in power system. The saturation of a current transformer distorts input current of a distance relay and arcing faults make current and voltage to be changed. This paper describes modeling methods of a current transformer and arcing faults, and describes the simulation result of two distance relay algorithms (discrete fourier transform and modified differential equation methods)

  • PDF

765 kV 조립식점퍼장치의 점퍼혼 설계기법 및 적용방안 (Design method and application on the jumper-horn of the 765 kV prefabricated jumper device)

  • 조성배;강연욱;윤상훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2086-2088
    • /
    • 1999
  • 765kv Transmission lines of the contaminated areas need many insulators due to the contamination. So the length of the arcing hem is very long. Because it is very difficult to install the arcing hem on insulator string sets due to its length, we must install the arcing horn on the jumping devices, and studied about the jumper horn. This paper described the investigation and analysis of the installation status of the arcing horn, and the design of the jumper horn for 765 kV transmission lines.

  • PDF

병렬아크의 고속 차단에 관한 연구 (A Study on the High Speed Breaking of Parallel Arcing)

  • 김일권;지홍근;김성욱;박대원;길경석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.327-331
    • /
    • 2008
  • This paper dealt with high speed breaking method to parallel arcing in low-voltage systems. The proposed high speed breaking circuit consists of a Rogowski coil and an integrator, and operates with an earth leakage circuit breaker (ELCB). A parallel arcing state was simulated by a short circuit using stripped wires. In this test, we analyzed tripping characteristics of the circuit breaker by the length of wires from 5m to 30m. From the experimental results, we confirmed that the proposed method can break the parallel arcing within a few millisecond.

  • PDF

아크시간이 초고압 가스차단기의 차단성능에 미치는 영향 (Effect of arcing time on the interruption Performance of EHV class GCB)

  • 박경엽;신영준;송기동;정진교;송원표;권기영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.161-163
    • /
    • 1998
  • The interruption performance of EHV class gas circuit breakers critically depends on the flow conditions inside interrupter and the external circuit conditions. In case of puffer type gas circuit breakers the flow conditons are significantly influenced by arcing time. In this paper the calculated results of RRRV and pressure rise at current zero with varying arcing time are presented and the effect of arcing time on the thermal interruption performance of EHV class gas circuit breakers is analyzed.

  • PDF

해수로 오염된 처점의 개간이-크의 발생과 소멸 (Arcing and Quenching of the Contacts Contaminated with Sea Water)

  • 조광현;박상길;박정후
    • 대한전기학회논문지
    • /
    • 제34권4호
    • /
    • pp.135-143
    • /
    • 1985
  • The failure and erosion of relay contacts mainly depend on the presence of particles deposited on the contact surface in various contaminated atmospheres. In this paper, the effects of sea water and circuit parameters on the arcing and quenching of magnet relay contacts are studied. The sea water pollutants of relay contact surface have led to increase the arcing numbers on making contact, and the mean arc durations on breaking contacts. Moreover, the maximum surge voltage and mean arc duration between relay contacts are also varied significantly by the circuit parameters. The effects of the spark quenching circuits using condenser of diode on the arcing of contacts are also discussed.

  • PDF

팬터그래프-전차선간 아크 검측 장치의 신뢰성 분석 (Reliability Analysis of Arcing Measurement System Between Pantograph and Contact Wire)

  • 박영;권삼영;김재문
    • 전기학회논문지
    • /
    • 제61권8호
    • /
    • pp.1216-1220
    • /
    • 2012
  • The current collection between pantograph and contact wire is a more critical component for need to train speed up in electric railway. The basic purpose of this paper is to establish a measure of determining arc by developing an arc detector assessment system. The system was designed under conditions of EN 50317 and simulations were conducted using the developed device. According to the results, it was possible to conduct certification tests following regulations of international standards. To check the validity of our approach for the intended application, we analysis contact loss of catenary system using developed arcing measurement system in Korea. The proposed arcing measurement system is expected to enhance precision of current collection quality performance assessment methods at high-speed lines and conventional lines.

차단기 아크접점의 마모저감을 위한 차단시점제어 (Control of the Breaking Instant for Mitigating Contact Wear of Circuit Breaker)

  • 이우영;박경엽;오연호;정진교;김희진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1106-1108
    • /
    • 2004
  • The arcing contact wear of circuit breakers can be the major cause for the maintenance requirement. The control of arcing times as short as possible but larger than the given minimum arcing time may be the effective way to mitigate the contact wear and to lessen the expenditure of a maintenance. In this paper the method for minimizing the arcing time is described. The basic concept used in the proposed method is the estimation of the current interruption instant from the informations such as the phase angle at the instant of trip commands and the magnitude of interrupted currents.

  • PDF

전기저항용접의 파형제어에 관한 기초연구 (Preliminery study of waveform control in ERW process)

  • 조민현;김동철;강문진;은성수
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2009년 추계학술발표대회
    • /
    • pp.32-32
    • /
    • 2009
  • Electric Resistance Welding (ERW) process is the most efficient process to manufacture the linepipe. To develop the high performance ERW linepipe using the high strength and the high alloy steels, the modulation of input power waveform such as sinusoidal waveform is introduced because the conventional ERW technology is not sufficient enough to produce the high quality linepipe due to its strength and high alloy contents (high Ceq). In this article, the material used for the experiment was API X60 with 8.2mm thickness, and ERW simulator at POSCO was used to develop a waveform control system for the power modulation. The frequency of power modulation was varied from 50Hz to 150Hz with the fixed amplitude of ${\pm}2%$ power. The non-modulated power input and the modulated power input cases are conducted to demonstrate the variation of the narrow gap length and the arcing frequency due to power modulation. From results of the non-modulated power input case, the excessive power causes the longer narrow gap length and the low arcing frequency due to the large heat input and the strong electro magnetic force that increase the weld defect. On the contrary, the small narrow gap length and the high arcing frequency reduce the weld defect. After modulating the power input with 50Hz and 100Hz at the fixed power, the arcing frequency increases, but the narrow gap length does not change much. The high arcing frequency prevents the formation of weld defect because the sweeping frequently cleans the oxides on the narrow gap edges. As a result, the manufacturing window can be expanded by the power modulation that provides the stable ERW process for the quality improvement of the linepipe made from the high strength/high alloy steels.

  • PDF

팬터그래프와 전차선간 최소 이선아크 지속시간에 따른 이선율 변화량 분석 (Analysis of Percentage of Arcing between Pantograph and Overhead Contact Line as a Function of Duration of Arc)

  • 박영;이기원;권삼영;박철민;김재광;최원석
    • 전기학회논문지
    • /
    • 제63권6호
    • /
    • pp.855-859
    • /
    • 2014
  • Quality criteria for interaction between a pantograph and overhead contact wire is a most important requirement to assess of the performance for the current collection system. Interaction performance between pantograph and catenary system is subject to approval by the infrastructure manager when a new design and contraction of overhead contact line and pantograph are installed. Among the various performance, percentage of arcing at maximum line speed is a simple test method compared with contact force of pantograph due to direct sensing of pantagraph, calibrations, installations of train, and etc. On the other hand, percentage of arcing is need to reliable arcing detector and general requirements with accordance with EN 50317. In this paper, percentage of arcing are investigated on the function of duration of arc and proposed which is satiable of percentage of arcing. As a results, we proposed which duration of arcs are unsuitable from infrastructures point of view as performance testing for quality of current collection.

마이크로파조사를 위한 개질화 활성탄의 톨루엔 탈착 (Toluene Desorption of Modified Activated Carbon for Microwave Irradiation)

  • 최성우;추헌직
    • 한국환경과학회지
    • /
    • 제20권2호
    • /
    • pp.223-229
    • /
    • 2011
  • Toluene desorption of modified activated carbon for microwave irradiation was evaluated. As a virgin GAC reacted from microwave energy, it created an "arcing" between GAC particles in desorption process. The arcing became more and more vigorous and achieved a red flame of GAC. The silica coated GAC(Si/GAC) was developed to prevent arcing phenomenon and temperature control problem. The result shows virgin GAC with 5wt%, 10wt% and 20wt% silica had no arcing and could control temperature very well. However, the adsorption rate of Si/GAC was decreased by coated silica amount due to decreasing surface area of GAC. The 5wt% Si/GAC adsorption rate was quite similar to virgin GAC adsorption rate. After adsorption, the toluene-loaded GAC and Si/GAC was reactivated by 2450MHz MW irradiation with 300W for 5 min. Quantitative desorption of the toluene was achieved at MW irradiation at 300W with desorption efficiencies as high as 98.59% to 84.65%% after four cycles.